The Switch To More Energy-efficient Lighting

Transcription

The switch to more energy-efficient lighting

EuP DirectiveWe are readyPhase-out of inefficient productsPhilips is prepared for this changeover and can offer customers a range of energy savingThe EuP directive defines requirements for the environmentally-sustainable design ofand environmentally friendly alternatives within all key segments. Use the tables on theenergy using products. Products falling outside of the framework require correctivenext few pages to identify the energy saving solutions that are most suitable for you!action. Household lighting and tertiary lighting (street, office, industrial) have beenidentified as requiring action; any inefficient lighting products within these segments willbe phased out and replaced with energy saving alternatives clearly labeled with theirenergy efficiency rating.Consequences of EuP for domestic lighting, part 1Minimum efficiency requirement, energy efficiency ratingFrom September each year20092010201120122013201420152016Standard CCCCCCCCCCCBBBBBStandard lampfrostedAAAAAAAALow volthalogen lampsclearG4 / gh volthalogen lampsclear12Vol t 60W75W100WG9 / R7S150W200W300W500W 750WFrosted halogen lamps230High and low voltVoltReflector lampsHigh and low volt80% lightin 120 angleEnergy-saving lampsfrostedColours: see energy efficiency label212 2009EuP DirectiveVol t23012VoltVol tNA not applicableStatus 17.03.2009In future all lamps which do not meet thespecified minimum efficiency requirementsfor energy efficiency ratings will be replaced.

Standard lamps100W60WPhase-out of inefficient incandescent lampsSwitch to energy saving alternativesThe phase-out of incandescent lamps commences from theStandardlamp1st September with the 100W lamp and all frosted derivatives.30%ENERGYTimetable for discontinuation of inefficient lampsFrom September each 14SAVING2015Discontinuation of all clear lampsIncandescentfrosted Replace frosted lamps with energy-saving lampswith energy efficiency rating APermittedNote: all wattages are indicative. The deciding factor is the light output (lumen).Discontinued Lamps may no longer be offered for sale. All existing stocks may be used 105W140WLengthmm107107107107107107Incandescent mm979797979797123.5145.5EcoClassic- Same style and shape as atraditional incandescent- Twice the life of a standardincandescent- Crisp, sparkling white lightMASTER NGStandardlamp40W60WStandardlamp25W40W60 W16W20W23WLengthmm109109- Long life for reducedmaintenance costs- Ideal retrofit to incandescentor a good alternative to CFLi- Plugs into standard light 7.1151.6162.3Softone ESaver- Long life for reducedmaintenance costs- Flicker free, immediate start- Excellent cost of ownershipMASTER Ambiance- 12 times longer lifetime thanstandard incandescent- Soft diffused light forgreater ambiance- Ideal for emergency currentoperationThis is only a selection of our products. For further information please refer to our current catalogue or the Internet.EuP Directive 20093

Standard lamps40WSwitch to energy saving alternativesPhilips MASTER LED lamps offer simple retrofit solutions to incandescentStandardlampand halogen lamps so you can substantially reduce your energy bills andmaintenance costs – without compromising on light quality and ambiance.These good-looking lamps also emit no heat, UV or infrared in the light beam80%and are mercury free. And with the EU phase-out of old GLS lamps alreadySAVINGENERGYunderway, this is a great time to future-proof your lighting installation byswitching to LED. Attractive design Up to 80% energy savings compared with standard incandescent lamps Extremely long life (45,000 hrs) Great for hard to reach areas where maintenance costs are high Simple retrofit, plugs into most standard light fittings Excellent for light sensitive objects (no UV or infra red)Incandescent 23W27W33WLengthmmAnticipatedavailability fromSept 152.2174.2196.2Genie- Long life for improvedmaintenance- Flicker free, immediate start- Compact designAlso suitable as a candle replacementMASTER PL-Electronic- Long life (15,000 hours) up to15 times more than an incandescent- Great for hard to reach areaswhere maintenance costs are high- Switching enduranceAlso suitable as a candle replacement Choice of beam angle for greater design flexibility Dimmable80%ENERGYStandardlampMASTER LED A55 7WMASTER LED- Extremely good cost of ownership50W7W (dimmable)40W7W (dimmable)SAVING- Long average rated life (45,000 hrs)- Excellent for light sensitive objectsThis is only a selection of our products. For further information please refer to our current catalogue or the Internet.Green products Best-in-class lamps that help protect the environment4EuP Directive 2009

Standard lamps40WE14E27Switch to energy saving lability:from Sept 09from Sept 09from Sept 09from Sept 09from Sept 09from Sept 09EcoClassic- Compact style for greaterdesign freedom- Twice the life of a standardincandescent- Crisp, sparkling white lightIncandescent lampsStandardlampStandardlampLengthmm15 w25 w40 w60 w25 w40 w60 w78– E1478– E1478– E1478– E1473 – E2773 – E2773 – E2780%ENERGYSAVING25W40W25W40WSoftone Mini5W8W5W8WLengthmm85858080Softone Mini- Extremely compact shape- Soft, non-glare light- Long lifetime for improvedmaintenancePhilips EcoClassic lamps look exactly the same as the old incandescent lamps– the only difference is they will save you 30% on your energy bills and lasttwice as long.*With the new EU legislation phasing out the old incandescent lamps,80%StandardlampLED LampAnticipatedavailabilitySAVING 15W2W – E14(dimmable)from Sept 09ENERGYLED Lampthere’s never been a better time to uplamp to Philips EcoClassic.- Excellent cost of ownershipHere’s how you benefit:- Long lifetime- Warm white colourtemperature for improvedambiance Keep the shapes you know 30% energy saving for reduced electricity costs At 2,000 hrs, twice the life of a standard incandescentThis is only a selection of our products. For further information please refer to our current catalogue or the Internet. Lower maintenance Crisp white halogen light Plugs into standard light fittings Dimmable for extra flexibility Instant light Meets new EU legislation requirements* Based upon 4,000 hrs burned per year, 8p per unit for electricity and 2 labour cost.EuP Directive 20095

Candle lamps40WSwitch to energy saving alternativesStandard light bulbs are also affected by the implementation measure forStandardlampdomestic lighting. MASTERClassic and EcoClassic are ideal alternativespriorities: e.g. lighting in hotels, restaurants, churches and living areas (e.g. in30%chandeliers or designer lighting). With other alternatives, e.g. Softone candlesSAVINGfor applications where optimum light quality and energy savings are jointEcoClassicCandle25W18WAnticipatedavailability fromSept 0940W28W99.560W42WAnticipatedavailability fromSept 09StandardlampMASTERClassic CandleLengthmm25W13WAnticipatedavailability fromSept 200940W20W103StandardlampSoftone ESaverCandleLengthmmENERGYor LED lamps, it is possible to save up to 80% energy.LengthmmEcoClassic Candle- Same style and shape as atraditional incandescent- Twice the life of a standardincandescent- Crisp, sparkling white lightStandard candle lampsStandardlampLengthmm15W25W40W60W25W40W60W100 – E14100 – E14100 – E14100 – E1496.5 – E2796.5 – E2796.5 – W135.225W5W9940W8W11460W12W120SAVINGMASTERClassic Candle- Long life for reducedmaintenance costs- Ideal retrofit to incandescentor a good alternative to CFLi- Plugs into standard light fittingSoftone ESaver Candle- Long life for reducedmaintenance costs- Flicker free, immediate start- Excellent cost of ownershipLED Candle Lamp80%StandardlampLED candlelampAnticipatedavailability- Suitable for chandeliers withits simple, compact designSAVING 15 w2.5 w(dimmable)from Sept 09- Long lifetime for improvedmaintenanceENERGY- Excellent cost of ownershipThis is only a selection of our products. For further information please refer to our current catalogue or the Internet.6EuP Directive 2009

Halogen lampsPhase-out of inefficient halogen lampsSwitch to energy saving alternativesSeptember also sees the start of the phase-out of inefficient halogen lamps.EcoHalogen capsuleAny frosted halogen lamp will be phased out along with any lamp with an30%energy efficiency rating of D, E or F. Use the table to identify alternative energysaving eAnticipatedavailability:40W28Wfrom Sept 0960W42Wfrom Sept 09230VoltExcellent energy saving withlonger lifetime- Capsule- Clear- G9 capTimetable for discontinuation of inefficient halogen lampsHigh volt G9 capsulefrom September each year20092010201120122013201420152016Halogen lampsclear12Vol 10W20W35W50W75W100WHalogen lampsclear230Volt25W40W60W75W100W150W200W300W500W 750W25W40W60W75W100W150W200W300W500W 750W25W40W60W75W100W150W200W300W500W 750W25W40W60W75W100W150W200W300W500W 750W25W40W60W75W100W150W200W300W500W 750W25W40W60W75W100W150W200W300W500W 750W25W40W60W75W100W150W200W300W500W 750W25W40W60W75W100W150W200W300W500W 750WPlusline compact20%ENERGYSAVINGR7s high volthalogen sticks20%ENERGYSAVINGHalogen lamps frostedDiscontinuation of all frosted halogen lamps230 12(high volt G9, E14, E27 cap – low volt G4, GY6.35 cap)VoltVol y:Excellent energy saving withlonger lifetime60W48Wfrom Sept 09- 78mm100W80Wfrom Sept 09150W120Wfrom Sept 09- Halogen from Sept 09200WStandardlamp230Volt- ClearPlusline small230VoltExcellent energy saving withlonger lifetime160Wfrom Sept 09- 117mm300W240Wfrom Sept 09- Halogen stick500W400Wfrom Sept 09- ClearPermittedNote: all wattages are indicative. The deciding factor is the light output (lumen).Discontinued Lamps may no longer be offered for sale. All existing stocks may be used up.40%ENERGYSAVINGStandard halogen capsuleGY6.35 low xcellent energy saving withlonger lifetime75W45W50W- Compact size30W35W20W- DimmableThis is only a selection of our products. For further information please refer to our current catalogue or the Internet.Green products Best-in-class lamps that help protect the environmentEuP Directive 20097

Sodium high pressure lampsPhase-out of inefficient high pressuresodium lampsSwitch for improved efficiencyThe implementation measure for office, industry and street lighting(tertiary) has set new requirements of minimum efficiency for highpressure sodium lamps. Inefficient high pressure sodium lamps will bephased out from April 2012.Timetable for discontinuation of inefficienthigh-pressure discharge lampsFrom April each year2010201220152017Sodium highDiscontinuation of all inefficientpressure lamps high pressure sodium lampsSodium high pressurereplacement lampsDiscontinuation of all inefficient highpressure sodium replacement lampsMercury vapourlampsDiscontinuation of all inefficient highpressure sodium replacement lampsStandard sodiumhigh pressure lampMetal halideDiscontinuation of all inefficient metal halide lampslampsDiscontinuationof other typesStandardlampMASTER SON PIA lampMASTER CityWhiteCDO-ET50W70W100W150W50W70W100W150W- Warm-white colour temperatureStandardlampMASTER SON-T PIA PlusMASTER SON-T PIA lampMASTER WMASTER SON PIA Plus- PIA Technnology- Service interval of 4 years- High light output stabilityMASTER CityWhiteCDO-ET- Good colour reproduction- RobustPermittedNote: all wattages are indicative. The deciding factor is the light output (lumen).Discontinued Lamps may no longer be offered for sale. All existing stocks may be used up.Standard sodiumhigh pressure lampin tube form- PIA Technnology- Service interval of 4 years- High light output stabilityMASTER CityWhiteCDO-TT- Warm-white colour temperature- Good colour reproduction- RobustThis is only a selection of our products. For further information please refer to our current catalogue or the Internet.8EuP Directive 2009

Mercury vapour lampsSwitch to energy saving 0W*125W*250W*400W*68W*110W*220W*350W*SON-H- Low operating costs- Change from white to yellow light- Up to 55% more lightMercury vapourlampThis time of financial and energy crisis is the time to look for newapproaches. Mercury vapour lamps are on the way out. They will lose theirCE-certification from 2015. Cities and boroughs need to think ahead ASTER CityWhiteBeneKitCDO-ET 70WCDO-ET 70WCDO-ET 150WMASTER CityWhiteBeneKit- Designed specifically forconverting antique lights- More light and bettercolour reproductionHistoric districtlightsintroduce new lighting solutions into their future housing designs. Modernlighting concepts will enhance the whole cityscape. Both residents andguests will benefit from the results.Philips supplies a broad spectrum of low-maintenance, high-quality outdoorlights to meet today‘s demands.* In 2015 these lamps will lose their CE-certification.This is only a selection of our products. For further information please refer to our current catalogue or the Internet.EuP Directive 20099

Fluorescent lampsPhase-out of inefficient fluorescent lampsSwitch to energy saving alternativesThe implementation measure for office, industry and street lighting(tertiary) defines new requirements for minimum efficiency and colour10%reproduction in fluorescent lamps.ENERGYIn April 2010 new EU legislation comes into force, meaning soon you won’tSAVINGbe able to buy the old fluorescent standard colour 29/33/35 halophosphateMASTER TLD EcoTL-D lamp33-64018W36W58WMASTERTL-D Eco16W32W51Wlamps. So if you’re currently using any of these lamps, now’s the time to thinkabout switching to alternatives.TL-D standard lampsLight colour 33-640Philips MASTER fluorescent triphosphor lamps offer a huge numberTL-D lamp33-640of benefits: better colour quality and at least double the lamp life of an18W30W36W58Woutdated fluorescent – making the Philips MASTER range an ideal choicefor all applications. Each Philips MASTER fluorescent has its own uniqueMASTERTL-D Super 8018W30W36W58W- Long life: lower maintenance, less hassle- Great in applications whentemperatures are 20 degrees C- Improved light output compared tohalophosphate and comparable toSuper 80MASTER TLD Super 80- Great alternative to halophosphatelamps with better quality light- Long life: lower maintenance, less hassle- Retains light output during almostentire operating lifeadvantages, so whether you want extra-long life, energy-saving or toincrease alertness in your workforce, we have the right lighting solution50%for you.ENERGYSAVINGTimetable for phase-out of inefficient fluorescent lampsFrom April each year20102012201518W36W58WMASTERTL-D Reflex18W36W58WMASTER TLD Reflex- 85% of the light is directed downwards- 1 Reflex lamp replaces 2 standardlamps in fixtures without reflectors- Better colour reproduction2017Fluorescent lamps- T8 and T5 Discontinuation of all inefficient fluorescent replacement lamps- TL-D U-shape minimum efficiency (Im/W) and RA 80- TL-D ring shape (light colours 33-640, 54-765)TL-D lamp33-640Discontinuation of all inefficient fluorescent replaceT12 minimum efficiency (Im/W) and RA 80(light colours 33-640, 54-765)Lamps withConventional/low-loss ballastTL-D lamp33-64018W36W58WMASTERTL-D Xtra18W36W58WMASTER TLD Xtra- Very long lifetime and few early failures- Low operating costs- Environmentally friendly;low mercury contentDiscontinuedof inefficient Lampswith conventional/low-loss ballastPermittedNote: all wattages are indicative. The deciding factor is the light output (lumen).Discontinued Lamps may no longer be offered for sale. All existing stocks may be used up.TL-D lamp33-64018W36W58WMASTER TL-DXtreme 84018W36W58WMASTER TLD Xtreme 840- Very long lifetime and few early failures- Low operating costs- Environmentally friendly;low mercury contentThis is only a selection of our products. For further information please refer to our current catalogue or the Internet.Green products Best-in-class lamps that help protect the environment10EuP Directive 2009

NotesEuP Directive 200911

For further information please contact us at:Philips LightingGuildford Business ParkGuildfordSurreyGU2 8XHUKTelephone: 0845 601 1283Telefax: 01483 575 534E-mail: rademarks owned by the Philips Group. Koninklijke Philips Electronics N.V. All Rights Reserved.

For further information please refer to our current catalogue or the Internet. 4 EuP Directive 2009 Standard lamps Incandescent lamps Switch to energy saving alternatives 40W Philips MASTER LED lamps offer simple retrofit solutions to incandescent and halogen lamps