Halo LT Selectable Dimming Guide - Cooper Lighting

Transcription

LT SeleCCTable Retrofit LED Downlight SeriesHALO Dimming Guide and Step-down Transformer Application NoteThe LT SeleCCTable LED Series provides continuous dimming withreverse or forward phase cut dimmers.LT4 3CCTLT56 HRLTSS56069FS231EWHR3000K 4000K 5000K2700K/3000K/3500K3000K/4000K/5000KPhase Control DimmingLT56 SeleCCTable recessedhousing installation.120V AC dimmedpower to HaloLED Downlights120V AC Power(2 wire Gnd typical)HALO Home In-wall Smart DimmerHIWMA1BLE40AWHControls standard lighting fixtures with dimmeror HALO Home mobile app.Features include: ON/OFF Dim Group Scene ScheduleTD518406EN page 1March 1, 2021 3:45 PM

LT4 / LT56 SeleCCTableCompatible DimmersDimmerMakeCooperLightingSolutionsDimmer SeriesHalo Home3000K 4000K 5000KDimmerModel #HIWMA1BLE40AWHMinimumLuminaires(per circuit)MaximumLuminaires(per circuit)MinimumMeasured LightOutputMaximumMeaured LightOutputLow End StartTime1353%99% 1sTD518406EN page 2March 1, 2021 3:45 PM

LT4 / LT56 SeleCCTableFor Reference OnlyDimmer MakeDimmerModel #Dimmer SeriesMinimumLuminaires(per circuit)MaximumLuminaires(per circuit)MinimumMeasured LightOutputMaximumMeasured LightOutput3000K 4000K 5000KLow EndStart TimeLevitonSureSlide66741174%97% techIPL061175%97% 1s (2)LevitonSureSlide6633-P1700%99%NA (1)LutronTogglerTG-600P1702%96% 1sLutronNova TNTFTU-6A17014%99% 1sEatonRF SmartRF9540-N1353%99% 1sLutronLumeaLG600P1700%97% 1sEWDUniversalTUL06P-C21355%97% 1sEWDUniversalSUL06P1355%96% 1sLutronSkylarkSCL-153P-WH1175%95% 1sLutronDivaDV603P1701%97% 1sLutronDivaDVCL-153P1175%94% 1sLutronMaestroMACL-153-M1175%85% 1sLevitonViziaVPE061704%100% 1sLevitonLegrandH703PTU1355%100% 1sLevitonViziaVZE041475%99% 1sLevitonAcentiATX1011174%98% 1sLutronMaestroMAELV6001706%99% 1sLutronFaedraFAELV5001586%99% 1sLutronDivaDVELV303P1353%96% 1sLutronSkylarkSELV300P1353%98% 1sEWDSmartAAL061355%98% 1sLightolierSunriseZP260QEW1305%98% 1sEatonAspire9530AW1700%100% 1s 1sEatonSkyeSF8AP11128%99%EatonDevineDE06P1702%83% 1sEatonReactRI0611700%99%NA (1)EatonDevineTAL06P1355%99% 1sEatonToggleDAL06P1355%99% 1sEatonSkyeSAL06P1355%100% 1sEatonSkyeSLC03P1355%99% 1sEatonDevineDLC03P1355%99% 1sEatonToggleTI0611700%79%NA (1)Lutron(PANEL)LCP128 (TRIAC)LP-RPM-4U-12012250%99%NA (1)Lutron(PANEL)LCP128 (ELV)LP-RPM-4A-12011410%98%NA 00%NA (1)LutronAriadniAY-600P1703%98% 1sLutronContourCT-103P11170%97% 1sLutronContourCT-600P1700%97% 1sLutronRotaryD-600P1700%94%NA (1)LutronDivaDV-600P1700%97% 1sLutronGlyderGL-600P1700%97%NA (1)LutronLumiaLG-600PH1700%97% 1sLutronNovaN-6001700%99% 1sLutronSkylarkS-600P1700%97%NA (1)LutronCenturionC-600P1700%99% 1sLutronAriadniAYLV-600P1523%99% 1sLutronGlyderGLV-6001520%99% 1sLutronDivaDVLV-600P1522%97% 1sLutronLuminaLG-103P11172%98% 1sLutronSkylarkSLV-600P1520%98% 1sEWDUniversalDUL06P-C71354%97% 1sLutronNovaNTLV-6001353%99% 1sLutronNovaNT-6001521%99% 1s1. Dims to Off2. Flash at StartupTD518406EN page 3March 1, 2021 3:45 PM

Dimmer Notes:1) Start time is measured at the lowest dimmer setting.2) Some LED dimmers have a "rapid start" design used to provide a momentary power boost to LED and CFL lamps during start-up. When a LEDluminaire is on a dimmer with "rapid start" the boost may cause a momentary flash of the LED lighting. This "flash" is generated by the dimmer,and may be more noticeable when the dimmer is at a low setting.Dimming Guide Disclaimer:1) Leviton is a registered trademark of Leviton Manufacturing Co. Inc.; Lutron is a registered trademark of Lutron Electronics Co.Inc.; Lightolier is a registered trademark of Philips Lighting; Hubbell is a registered trademark of Hubbell Incorporated; Legrand andPass & Seymour are registered trademarks of Legrand ; Eaton is a registered trademark of Eaton Corporation. These companies and theirtradenames, trademarks or brands, where noted, are associated with their respective company and are not associated with Cooper LightingSolutions.2) Testing conducted by Cooper Lighting Solutions is not a substitute for and does not imply certification by an independent laboratory or anyother standards certification. Refer to the manufacturer specifications for more detailed information on product certifications and standards.3) This is a representative list of typical dimmers as tested by Cooper Lighting Solutions for performance with the designated LED luminairesonly. Test data contained in this literature is based upon dimmers obtained in the marketplace. Information about these other manufacturersproducts is obtained from packaging and published information made available by the manufacturer and is deemed to be reliable, but hasnot been verified. Dimmer performance and perceived limitations of the dimmers are based on factors outside of Cooper Lighting Solutions'control. The specifications of these dimming controls and their conditions of use may change without notice to Cooper Lighting Solutions orany other user. Cooper Lighting Solutions makes no specific recommendation on product selection and there are no warranties of performanceor compatibility implied. Installer must ensure proper local and national electrical codes are followed; and that the dimmer application andcondition of use is per dimmer manufacturer instructions and guidelines.TD518406EN page 4March 1, 2021 3:45 PM

Application Note - H277, H347 and H347200 step-down transformers are qualified to drive multipleHalo LED on a single circuit in Non-IC construction. Installation of these transformers with individualLED fixtures on circuits with multiple LED loads is not recommended. This is not recommended dueto resulting multiple inductive currents pulled by each transformer; in this situation the majority of thepower would then be reactive (VARS) and not real (WATTS). If H277, H347 or H347200 transformersshould be used individually on each LED fixture in a single circuit, then that circuit should be sized forlowered power factor as well as increased apparent power on the circuit. H277, H347 and H347200 areUL/cUL listed for use with Halo recessed housings: H750T, H750TCP, H7T, H7TNB, H7RT.2-7/8H277277V Step Down Transformer,300VAStep Down TransformersH277 Steps 277 line voltage down to 120 volts. Attaches to knockout on first fixture’s junction box in acircuit and is 300VA rated. H277 is a UL recognized Component listed under the luminaire UL/cUL listingfor Halo Non-IC housings.H347 and H347200 Steps 347 line voltage down to 120 volts. Attaches to knockout on first fixture’sjunction box in a circuit. H347 is 75VA and H347200 is 200VA rated. H347 is a CSA/UL ListedComponent for use under the luminaire UL/cUL listing with Halo Non-IC housings.4-3/16”[106mm]2-7/8Transformer Load - H277 (300VA)1. H277 Transformer at full loading consumes a maximum of 16W of power.2. When a dimmer or switch is on the secondary (120V) side of the transformer, power is consumedby the transformer when the dimmer or switch is in “OFF” mode at 6.5W and in “ON” mode at 16Wmaximum under full loading.3. When a dimmer or switch is on the primary (277V) side ahead of the transformer, power is consumedonly in “ON” mode to a maximum of 16W under full loading.(Use of a dimmer ahead of the transformer is not recommended)Transformer Load - H347 (75VA)1. H347 Transformer at full loading consumes a maximum of 15W of power.2. When a dimmer or switch is on the secondary (120V) side of the transformer, power is consumedby the transformer when the dimmer or switch is in “OFF” mode at 2.5W and in “ON” mode at 15Wmaximum under full loading.3. When a switch is on the primary (347V) side ahead of the transformer, power is consumed only in “ON”mode to a maximum of 15W under full loading.(Use of a dimmer ahead of the transformer is not recommended)Transformer Load - H347200 (200VA)1. H347200 Transformer at full loading on 120V side consumes a maximum of 28W of power.2. When a dimmer or switch is on the secondary (120V) side of the transformer, power is consumedby the transformer when the dimmer or switch is in “OFF” mode at 9.2W and in “ON” mode at 28Wmaximum under full loading.3. When a switch is on the primary (347V) side ahead of the transformer, power is consumed only in “ON”mode to a maximum of 28W under full loading.When a switch is on the primary (277V) side ahead of the transformer, power is consumed only in “ON”mode to a maximum of 12W under full loading.(Use of a dimmer ahead of the transformer is not recommended)H2772-3/16”[56mm]H347347V Step Down Transformer, 7V Step Down Transformer,200VALT56069FS231EWHR Retrofit LED Downlight Series(LT56069FS231EWHR Maximum Units on Step Down Transformer Powered Circuits)TransformerVA RatingMax # of ��[56mm]4-3/4”[121mm]TD518406EN page 5March 1, 2021 3:45 PM

Transformer with Dimmer/Switch on 120V Secondary120V Dimmer or LEDNeutralGroundDimmer Neutral Connection typical with some DimmersTransformer with Switch on 277V EDLEDLEDLEDLEDNeutralGround*Use of a dimmer ahead of the transformer is not recommendedTransformer with Switch on 347V Primary347V nd*Use of a dimmer ahead of the transformer is not recommendedCooper Lighting Solutions1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.cooperlighting.com 2021 Cooper Lighting SolutionsAll Rights Reserved.Specifications and dimensionssubject to change without notice.TD518406EN page 6March 1, 2021 3:45 PM

2) Some LED dimmers have a "rapid start" design used to provide a momentary power boost to LED and CFL lamps during start-up. When a LED luminaire is on a dimmer with "rapid start" the boost may cause a momentary flash of the LED lighting. This "flash" is generated by the dimmer, and ma