BUDWOOD BUILDING

Transcription

874 Dixon BoulevardCocoa, FL 32922SYMBOLSINGLE POLE SWITCH(SUBSCRIPT INDICATES ITEM CONTROLLED)S3THREE-WAY SWITCHS4FOUR-WAY SWITCHSPSINGLE POLE SWITCHWITH PILOT LIGHTS WPSINGLE POLE SWITCHWITH WEATHERPROOF LOCKING COVERSKSINGLE POLE KEY SWITCHS 4KS LVLOW VOLTAGE SWITCHSFFAN SWITCHSMMANUAL MOTOR STARTER WITH OVERLOAD HEATERSPROVIDE AUXILIARY CONTACTS AS REQUIRED BY EQUIPMENT INSTALLED.S MPMANUAL MOTOR STARTER WITH OVERLOAD HEATERSAND PILOT LIGHTSDDIMMER SWITCH(1500 WATTS UNLESS OTHERWISE INDICATED)S OSVFDVARIABLE FREQUENCY DRIVEDDCDIRECT DIGITAL CONTROL PANELT30ARNFNON-FUSED DISCONNECT SWITCH, SIZE AS NOTEDNF DENOTES NON-FUSED30AR20AFFUSED DISCONNECTAR DENOTES AMP RATING OF SWITCHAF DENOTES AMP FUSE SIZEMCPSIZEWSBRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS,SURFACE MOUNTEDBRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS,FLUSH MOUNTEDOCCUPANCY SENSOR (DUAL TECHNOLOGY)BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS,SURFACE MOUNTEDWALL STATION FOR LIGHTING CONTROLSE ELEVATOR WITH RECALL CONTACTSI IONIZATIONDUCT SMOKE DETECTORR RETURNS SUPPLYBRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS,FLUSH MOUNTEDOCCUPANCY SENSOR - CEILING MOUNTED (DUAL TECHNOLOGY)(S DENOTES SECURITY OCCUPANCY SENSOR)SUPERVISED CONTROL RELAYRTIREMOTE INDICATING LAMP FIRE ALARM WITH TEST SWITCHWALL MOUNTED 72" AFFFCOMBINATION HORN/VISUALNOTIFICATION DEVICECD CANDELA RATING (75CD MINIMUM)XXCDSSXXCDENCLOSURE NEMA RATING.TIME SWITCHSTCEILING SMOKE DETECTOR, PHOTO-ELECTRICTYPE UNLESS OTHERWISE NOTEDFIRE ALARM HORN - CEILING MOUNTEDCD CANDELA RATINGXXCDWALL MOUNTED HORN WITH STROBECD CANDELA RATINGXXCDFIRE ALARM HORN - WALL MOUNTEDCD CANDELA RATINGCOMBINATION MAGNETIC MOTOR STARTER, SIZE & # OF POLES3 POLE UNLESS OTHERWISE NOTEDNEMA STARTER SIZEMSTWIST LOCK RECEPTACLETBRANCH CIRCUIT CONDUIT CONCEALED IN SLAB,UNDERGROUND OR UNDER FLOOR.SURGE PROTECTION TYPE (TVSS)DUPLEX RECEPTACLESPBRANCH CIRCUIT CONDUIT EXPOSEDPEDESTAL MOUNTED RECEPTACLEFLOOR OUTLET BOX AND DUPLEX RECEPTACLEWITH APPROPRIATE FLANGE.EMFLOOR OUTLET BOX WITH DUPLEX RECEPTACLEAND ONE COMBINATION W/ VOICE/DATA OUTLETFLOOR OUTLET BOX WITH TWO DUPLEX RECEPTACLESAND ONE COMBINATION W/ VOICE/DATA OUTLETPPP5.COORDINATE OUTLET BOX LOCATIONS WITH MASONRY TO MINIMIZE CUTTING OF BRICK OR BLOCK.6.ALL MOUNTING HEIGHTS TO CENTERLINE OF ITEM UNLESS OTHERWISE NOTED. VERIFY ALL OUTLETLOCATIONS ON THE JOB PRIOR TO ROUGH-IN.VISUAL SIGNALING UNIT, WALL MOUNTED(NO AUDIO DEVICE) (75CD MINIMUM)8.WHEN INCREASED CONDUCTOR SIZES ARE SHOWN ON THE PLANS, THE LARGER CONDUCTOR SIZESHALL BE USED THROUGHOUT THE LENGTH OF THE CIRCUIT, INCLUDING NEUTRAL AND GROUND.TSSPRINKLER TAMPER9.FSSPRINKLER WATERFLOWEACH DATA, TELEPHONE, VIDEO OR OTHER SYSTEMS OUTLET REQUIRES 1" C. WITH PULL STRINGSTUBBED TO TTB UNLESS OTHERWISE NOTED ON PLANS. PROVIDE INSULATED BUSHINGS ON ALLCONDUITS. LABEL CONDUIT TO IDENTIFY ITS INTENDED USE (IE: TELEPHONE, DATA, ETC.).FPFIRE ALARM SYSTEM PRINTERZAMZONE ADDRESSABLE MODULEELECTROMAGNETIC DOOR HOLD OPEN DEVICE(CONNECT TO BLDG FIRE ALARM SYSTEM)HELECTROMAGNETIC DOOR HOLD OPEN DEVICECONNECTION TO CLOSURE/ HOLDERHELECTROMAGNETIC DOOR HOLD OPEN DEVICECONNECTION TO CLOSURE/ HOLDER INCLUDES DETECTORHCEILING HEAT DETECTOR 135 F UNLESS OTHERWISEINDICATED.TBEAM DETECTOR - TRANSMITTERRFAAP11.BEAM DETECTOR - RECEIVERFIRE ALARM CONTROL PANEL13.FIRE ALARM TERMINAL CABINET14.FIRE ALARM SYSTEM CONDUIT AND WIRINGCONDUIT CONTINUEDPOWER POLEFLEXIBLE CONDUITDUPLEX RECEPTACLE WITHEACH HALF ON SEPARATE CIRCUIT.(BREAKER SHALL BE TWO POLE WITH COMMON TRIP)NEWEFIREMAN'S ELEVATOR WARNING LIGHTBWEATHERPROOF FIRE ALARM SPRINKLERBELLPROVIDE 120V CIRCUIT.CEILING MOUNTED STROBE/HORN, 75 CDMIN.FCODUPLEX RECEPTACLE MOUNTED ABOVE COUNTER.REFER TO LIGHT FIXTURE SCHEDULE FOR SPECIFIC INFORMATION ON LIGHT FIXTURE TYPES INDICATED ON PLANDRAWINGS.27.RECEPTACLES FOR ELECTRIC WATER COOLERS TO BE LOCATED DIRECTLY BEHIND ELECTRIC WATER COOLER,OUT OF SIGHT.28.PROVIDE ENERGY SAVING HIGH BALLAST FACTOR 0.88 OR HIGHER ELECTRONIC BALLASTS FOR ALLFLUORESCENT LIGHT FIXTURES.29.PROVIDE DIMMABLE BALLASTS FOR ALL DIMMABLE LIGHT FIXTURES, AND A DIMMER SWITCH RATED NOT LESSTHAN 2000 WATTS.30.CONTRACTOR SHALL UPSIZE FEEDER AND BRANCH CIRCUIT WIRE SIZE AS REQUIRED TO COMPENSATE VOLTAGEDROP FROM LENGTHENING OF CIRCUITS DUE TO FIELD ROUTING. FINALINSTALLATION SHALL MEET FLORIDA BUILDING CODE REQUIREMENT OF: MAXIMUM BRANCH CIRCUIT VOLTAGEDROP OF:EB #15TLC NO:2* MAXIMUM FEEDER VOLTAGE DROP OF 2%* MAXIMUM BRANCH CIRCUIT VOLTAGE DROP OF 3%15.2015-07-10 PRE-BID CLARIFICATIONSUGGESTED MIN. CONDUCTORCIRCUIT LENGTHCIRCUIT AMPS (I)UP SIZE FOR VOLTAGE DROP0 - 80'I 8A#12 AWG0 - 80'8 I 12A#10 AWG0 - 80'I 12A#8 AWG81' - 150'I 8A#10 AWG81' - 150'8 I 12A#8 AWG81' - 150'I 12A#6 AWG151' - 200'I 8A#8 AWG151' - 200'8 I 12A#6 AWG151' - 200'I 12A#4 AWG0' - 300'0' - 300'301' - 450'301' - 450'PROVIDE 18" LONG (MIN). CONDUIT SLEEVES THRU ALL WALLS WHERE CABLES ARE INDICATED ORREQUIRED TO PASS THRU WALLS. PROVIDE BUSHINGS ON BOTH ENDS. SIZE CONDUIT FOR CABLESINSTALLED. AT CABLE TRAYS, PROVIDE ONE 4" CONDUIT SLEEVE FOR EACH 4" WIDTH OF CABLE TRAY.MAXIMUMS SHALL BE.2"C 10 CABLES2 1/2"C 20 CABLES3"C 30 CABLES4"C 50 CABLESI 10AI 10AI 10AI 10A#12 AWG#10 AWG#10 AWG#8 AWG450' AND ABOVE TO BE DETERMINED BY EC AND APPROVED BY ENGINEER.31.EMERGENCY BALLAST BATTERY PACKS AND EMERGENCY EXIT SIGNS, WHERE USED, SHALL BE CONNECTEDAHEAD OF LOCAL SWITCHING.32.PROVIDE HACR RATED CIRCUIT BREAKERS FOR ALL HVAC EQUIPMENT.33.ELECTRICAL CONTRACTOR SHALL PROVIDE COORDINATION SHOP DRAWINGS WITH PLUMBING, FIREPROTECTION, AND MECHANICAL DEMONSTRATING COMPLIANCE WITH DEDICATED SPACE AND WORKINGCLEARANCE PER NEC.34.CONTRACTOR SHALL PROVIDE WITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE RECORD DRAWINGSOF THE ACTUAL INSTALLATION INCLUDING: SINGLE LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTIONSYSTEM AND FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION.35.CONTRACTOR SHALL PROVIDE AN OPERATING MANUAL AND MAINTENANCE MANUAL TO OWNER. THE MANUALSHALL INCLUDE AT A MINIMUM: (1) SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOREACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. (2) OPERATION AND MAINTENANCE MANUALS FOR EACHPIECE OF EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BECLEARLY IDENTIFIED. (3) NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY.36.TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE 2010FLORIDA BUILDING CODE WITH 2010 REVISIONS AND THE FLORIDA FIRE PREVENTION CODE (2010) AND ALL LOCALCODES AND ORDNANCES,37.CONTRACTOR SHALL PROVIDE A COMPLETE ROOF MOUNTED UL LISTED LIGHTNING PROTECTION SYSTEM FORTHE ENTIRE FACILITY PER THE REQUIREMENTS OF THE DIVISION "16" SPECIFICATIONS AND NFPA 780.38.CONTRACTOR SHALL PROVIDE TEMPORARY ELECTRICAL SERVICE FOR USE BY ALL TRADESDURING CONSTRUCTION. REMOVE TEMPORARY POWER AT THE COMPLETION OF THE PROJECT.CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS TO OBTAIN TEMPORARYELECTRICAL SERVICE.39.THE ELECTRICAL CONTRACTOR SHALL INSTALL ALL CONDUITS RACEWAYS, FOR THE SECURITY ELECTRONICSSYSTEMS THE SECURITY ELECTRONICS CONTRACTOR (SEC) SHALL PROVIDE AND INSTALL THE WIRE AND CABLEFOR THE SECURITY ELECTRONICS SYSTEMS AND ALL SECURITY ELECTRONICS EQUIPMENT. THE SEC SHALLSUPERVISE THE CONDUIT INSTALLATION AND VERIFY EXACT BACK BOX LOCATIONS AND CONDUIT STUB-UPLOCATIONS IN THE EQUIPMENT ROOMS.40.THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUITS, BACK BOXES, RACEWAYS, SLEEVES, SITECONDUIT DUCT BANKS AND MANHOLES FOR THE TELECOMMUNICATIONS SYSTEM. THE STRUCTURED CABLINGCONTRACTOR (SCC) SHALL PROVIDE AND INSTALL THE WIRE AND CABLE FOR THE SYSTEMS THEY AREINSTALLING. THE SCC SUPERVISE THE CONDUIT INSTALLATION AND VERIFY EXACT BACK BOX LOCATIONS ANDCONDUIT STUB-UP LOCATIONS IN THE EQUIPMENT ROOMS.LIGHT SWITCHES SHALL BE MOUNTED 48 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF DEVICE,UNLESS OTHERWISE NOTED.RECEPTACLES SHALL BE LOCATED 18 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF DEVICE,UNLESS OTHERWISE NOTED. ABOVE-COUNTER RECEPTACLES SHALL BE MOUNTED 6" ABOVE BACKSPLASH TO CENTERLINE OF DEVICE.EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICHTHEY ARE TO BE INSTALLED, WITH APPROPRIATE NEMA ENCLOSURE RATING.A. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITHNEC 110.B. THE EXCLUSIVELY-DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURALCEILING WITH A WIDTH AND DEPTH OF THE PANELBOARD OR SWITCHBOARD MUST BECLEAR OF ALL PIPING, DUCTS OR EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENTOR ARCHITECTURAL APPURTENANCES IN ACCORDANCE WITH NEC 408.CARBON MONOXIDE SENSOR, 24V DC16.DUPLEX SAFETY RECEPTACLE MOUNTCOVERPLATES WITH SPANNER HEAD SCREWSWHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE-RESISTIVE ASSEMBLIES, (CLASSIFIED ASFIRE/SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED WITHOUT AFFECTING THE FIRECLASSIFICATION. ALL OF THE FOLLOWING CONDITIONS SHALL BE MET:B. BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE.SIMPLEX RECEPTACLE (EWC DENOTESELECTRIC WATER COOLER. COORDINATE WITH EWCINSTALLER FOR MOUNTING HEIGHT).C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES.SOUND SYSTEMLIGHTINGWPD. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE COMPLETELYFILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL).E. PROVIDE A WALL AROUND OUTLETS LARGER THAT 16 SQUARE INCHES. THE INTEGRITYOF THE WALL RATING SHALL BE MAINTAINED.GFI RECEPTACLE MOUNTED ABOVE COUNTER.TWO DUPLEX RECEPTACLES WITH COMMON COVER.ISOLATED GROUND DUPLEX RECEPTACLE,(ORANGE DEVICE).IGACIRCUITNUMBER 2FIXTUREDESIGNATIONSCEILING MOUNTED SPEAKER 3/4" C. TO SOUNDSYSTEM.JUNCTION BOX MOUNTED @ 48" AFF TO SOUNDSYSTEMSPEAKER FOR ROOM VOLUME CONTROL.S VCaC:\Users\stephen.cotton\Desktop\local revit projects\2014 projects\512050 budwood\512050-Budwood-R14-local.rvt7/10/2015 3:13:49 PMCCLOCK RECEPTACLESPECIAL PURPOSE RECEPTACLE, RATING AS NOTEDGND17.FLUORESCENT WALL MOUNTED FIXTURE WITH WALL OUTLET BOXCHID, FLUORESCENT, OR INCANDESCENT FIXTURETELCOM OUTLET IN SINGLE GANG RECESSEDJUNCTION BOX MOUNTED @ 18"AFF UNO,3/4"C, CAT 6 TO IDF. C CEILING MOUNTED. CH MOUNTED ABOVECOUNTER HEIGHT.ALL RECEPTACLES SHALL BE MOUNTED SUCH THAT THE GROUND PIN IS MOUNTED UP.18.19.LIGHTING NOTES:1. ALL FLUORESCENT FIXTURES SHALL USE T8 LAMPS AND PROGRAMMED START ELECTRONIC BALLASTS, UNLESSOTHERWISE NOTED. ALL BALLASTS SHALL BE HIGH EFFICIENCY TYPE BF 0.88 MINIMUM. PROVIDE UNIVERSAL VOLTAGEBALLAST ON ALL NON-DIMMABLE FLUORESCENT LIGHTFIXTURES. ALL FLUORESCENT FIXTURES INSTALLED INAREAS WHERE EMI AND/OR RFI ARE A CONCERN SHALL BE EQUIPPED WITH LOW FREQUENCYELECTRONIC BALLAST.2. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHT FIXTURES. COORDINATETYPE OF CEILING FOR EACHFIXTURE WITH ARCHITECTURAL REFLECTED CEILING PLANS AND PROVIDE FIXTURETRIM AS REQUIRED.ALL BRANCH CIRCUIT CONDUITS SHALL CONTAIN A MINIMUM OF (2) #12AWG WIRES, PLUS A MINIMUM OF#12AWG GROUND WIRE UNLESS OTHERWISE NOTED. ALL BRANCH AND FEEDERS CIRCUITS SHALL HAVEINDIVIDUAL NEUTRAL CONDUCTORS.3. ALL MAGNETIC BALLASTED FIXTURES SHALL BE FUSED.COORDINATE THE LOCATION OF ALL DEVICES AND BOXES WITH WINDOWS, BUILT-INS, AND CABINETSPRIOR TO INSTALLATION OF CONDUITS OR BOXES. CONTRACTOR SHALL CONSULT ALL CONTRACTDRAWINGS TO VERIFY CONFLICTS PRIOR TO BIDDING.5. PROVIDE ALL REQUIRED HARDWARE TO MOUNT FIXTURES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS.4. PROVIDE APPROVED FIRE RATED ENCLOSURES FOR ALL LIGHT FIXTURES LOCATED IN FIRE RATED CEILINGS.WALL MOUNTED FIXTURE20.FLUORESCENT, OR INCANDESCENT WALL WASHER.21.COORDINATE HEIGHTS OF WALL MOUNTED LIGHTING FIXTURES TO CLEAR MIRRORS, CABINETS ANDBUILT-INS.EXIT LIGHT FIXTUREDIRECTION ARROWS AS SHOWN(SHADED QUADRANT INDICATES FACE(S) OF FIXTURE)22.PROVIDE A PERMANENT SIGN ON THE MAIN ELECTRICAL ROOM DOOR TO THE BUILDING STATING THATTHE MAIN SERVICE DISCONNECT(S) ARE LOCATED INSIDE.23.COORDINATE INSTALLATION OF ANY DEVICE LOCATED IN MILLWORK WITH ARCHITECTURAL DRAWINGSAND DETAILS PRIOR TO ROUGHING IN BOXES AND ROUTING CONDUIT.24.LOCATION OF EQUIPMENT SPECIFIED BY OTHER TRADES OR PROVIDED BY OWNER ARE APPROXIMATECOORDINATE EXACT LOCATIONS IN FIELD PRIOR TO ROUGHING IN AND ROUTING CONDUIT.GROUND BAR. CONNECT TO BUILDING GROUND SYSTEM USING #3/0ACCENT FLOOD LIGHTING - AIMING AS INDICATEDPLUG-IN STRIP WITH RECEPTACLES, 18" O.C. UNLESSOTHERWISE INDICATED. WIREMOLD SERIES 4000 AL.PUSH BUTTONJJUNCTION BOXWALL MOUNTED EXIT LIGHT FIXTUREJJUNCTION BOX- WALL MOUNTEDEXTERIOR LIGHT FIXTURE WITH ARMS AS SHOWNON DRAWINGSJJUNCTION BOX- FURNITURE SYSTEM FEEDSURGE SUPPRESSOR1 SERVICE ENTRANCE DEVICE2 PANELBOARD DEVICEALL DEVICES SHALL BE MOUNTED VERTICAL, UNLESS OTHERWISE NOTED.FLOORBOX, TELCOM OUTLET , 3/4"C, CAT 6 TO IDF.PBSPD 1I. THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED1/8 INCH BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE OPENING.FLUORESCENT FIXTUREDIAGONAL SHADING DENOTES EMERGENCY LIGHT FIXTURE.LIGHTING CONTROL TIME CLOCKPHOTOCELL, MOUNTED ON ROOF FACING NORTHH. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS.TELCOMQUAD RECEPTACLE.NOTE:TICK MARKS SHOWN ON ANY DEVICE REPRESENTSRECEPTACLE CONNECTED TO THE EMERGENCY CIRCUIT(RED DEVICE) TYPICAL FOR ANY DEVICE IN LEGENDG. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE-RESISTIVE ASSEMBLIES SHALL BESEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES.FLUORESCENT FIXTURELOWER CASE LETTER INDICATES CONTROL CIRCUIT SWITCH LEGDUPLEX RECEPTACLE.F. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUAREINCHES PER 100 SQUARE FEET.TRACK WITH TRACK LIGHT FIXTURE (TRIANGLESINDICATE QUANTITY OF LIGHT FIXTURES)6. PROVIDE ZERO DEGREE BALLASTS FOR ALL OUTDOOR LIGHTING FIXTURES.7. ALL ACRYLIC LENSED FIXTURES SHALL HAVE A LENS THICKNESS OF .125 INCHES MINIMUM.8. IF THERE IS A DISCREPANCY BETWEEN A FIXTURE DESCRIPTION, AND THE CATALOG NUMBER LISTED, THEFIXTURE DESCRIPTION SHALL DICTATE.project no.14229. COORDINATE DIMMING BALLAST AND DIMMING CONTROL PRODUCTS (PANEL, SWITCH, ETC.) FORCOMPATIBLE OPERATION.by10. ALL EXIT SIGNS AND FIXTURES WITH INTEGRAL BATTERY SHALL HAVE INTEGRAL TEST SWITCH AND LEDINDICATOR LIGHT.11. LOW-MERCURY LAMPS: COMPLY WITH EPA'S TOXICITY CHARACTERISTIC LEACHING PROCEDURE TEST;SHALL YIELD LESS THAN 0.2 MG OFMERCURY PER LITER WHEN TESTED ACCORDING TO NEMA LL 1.04.24.15sheet no.E00112. PROVIDE LAMP AND BALLAST INFORMATION DATA CUT SHEETS THAT INCLUDE ALL TECHNICALINFORMATION AS PART OF SHOP DRAWINGS.BATTERY PACK WITH TWIN HEADSNOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT.dateNORTHTWO DUPLEX RECEPTACLES WITH COMMON COVERMOUNTED ABOVE COUNTER.FLUORESCENT STRIP FIXTUREcopyright C 2014GFI RECEPTACLE. WP DENOTES WEATHERPROOF COVER.A NEW PROJECT FOR:A. ALL ELECTRICAL BOXES SHALL BE METALLIC.DUPLEX RECEPTACLE WITH TOP HALF SWITCHED.EWC512050REFER TO VOLTAGE DROP CHART BELOW FOR SUGGESTED CONDUCTOR SIZES FOR BRANCH CIRCUITSEACH BRANCH CIRCUIT RACEWAY SHALL HAVE A FULL LENGTH EQUIPMENT GROUND CONDUCTOR. FORISOLATED GROUND CIRCUITS, PROVIDE AN ISOLATED GROUND CONDUCTOR THROUGHOUT THE LENGTHOF THE CIRCUIT IN ADDITION TO THE PHASE, NEUTRAL AND EQUIPMENT GROUND CONDUCTORS.CONDUIT STUBPOKE THRU26. Copyright 2012 TLC Engineering for Architecture, Inc.ALL BRANCH CIRCUIT HOMERUNS SHALL BE ROUTED IN 3/4"C. MINIMUM.12.FIRE ALARM ANNUNCIATOR PLAN - FLUSH MOUNTEDFSEE ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF LIGHT FIXTURESIN LAY-IN OR DRYWALL CEILINGS, AND ON INTERIOR AND EXTERIOR WALLS.201' AND ABOVE TO BE DETERMINED BY EC AND APPROVED BY ENGINEER.10.FATCCONDUIT TURNING DOWNE.C. SHALL REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR THE REQUIREMENTSASSOCIATED WITH WIRING AND CONNECTION OF INTERLOCKING AND CONTROLS OF MECHANICAL UNITSAND THERMOSTAT LOCATIONS.SSEMERGENCY BRANCH CONDUITDN4.CONDUIT RUN WITH CONDUCTORS AS INDICATED & GROUND WIRE SIZED PER N.E.C 250-122. CONDUITSIZE AS REQUIRED.FACPCONDUIT TURNING UPREFER TO THE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.7.GROUND OR GROUND ROD AS NOTEDUP3.225.REFER TO RELATED ARCHITECTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION, CIVIL, LANDSCAPE,INTERIOR DESIGN, TECHNOLOGY AND STRUCTURAL DRAWINGS FOR RELATED INFORMATION ANDADDITIONAL INSTALLATION REQUIREMENTS.FIRE ALARM HORN WITH STROBE - CEILING MOUNTEDCD CANDELA RATINGBRANCH CIRCUIT CONDUIT CONCEALED ABOVECEILING OR IN WALL. CONDUIT SHALL INCLUDEPHASE, NEUTRAL AND GROUND CONDUCTORSAS REQUIRED FOR CIRCUITS (UNLESS OTHERWISE NOTED).DUPLEX RECEPTACLE2.FSPUSHBUTTON FOR AUTOMATIC DOORSWEATHERPROOF MOTION SENSORLEVITON MODEL# PS200-10 OR EQUAL1. STATE OF FLORIDA.2. LIFE SAFETY CODE - NFPA 101.3. UNDERWRITERS LABORATORIES, INC. PUBLICATIONS4. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA).5. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI).6. NATIONAL ELECTRICAL CODE - NFPA 70.7. INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS (IEEE).8. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA).9. REQUIREMENTS OF LOCAL POWER COMPANY.10. "FLORIDA BUILDING CODE 2010."11. THE AMERICANS WITH DISABILITIES ACT (ADA)12. "FLORIDA ACCESSIBILITY CODE"TP TAMPERPROOF COVER# OF POLES30/30 3RDESCRIPTIONMANUAL PULL STATIONRTRANSFORMERAUTOMATIC TRANSFER SWITCHFOUR-WAY KEY SWITCHSINGLE POLE SWITCH WITH SECURITY LOCKING KEYFMOTOR CONNECTION, NUMBER DENOTES HORSEPOWER5THREE-WAY KEY SWITCHSLSHUNT-TRIP BUTTONSYMBOLMAGNETIC MOTOR STARTER OR CONTACTORSIZE AS NOTEDSINGLE POLE SWITCHWITH WEATHERPROOF COVERS WPLS 3KSTDESCRIPTIONALL WORK AND EQUIPMENT UNDER THIS DIVISION SHALL BE IN STRICT COMPLIANCE WITH THE CODES,STANDARDS AND PRACTICES LISTED HEREIN, AND THEIR RESPECTIVE DATES ARE FURNISHED AS THEMINIMUM LATEST REQUIREMENTS.CITRUS REPOSITORY AT LA CROSSE, ALACHUA, FLORIDAFL DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICESSaDESCRIPTION1.BUDWOOD BUILDINGSYMBOLFIRE ALARM/DETECTION SYSTEMALL RIGHTS RESERVED, THESEPLANS ARE PROTECTED BYCOPYRIGHT LAWS.UNAUTHORIZED USE MAYRESULTIN LEGAL ACTION.BASIC MATERIALS CONT.BASIC MATERIALSPhone: 321-636-0274Fax: 321-639-8986www.tlc-engineers.comGENERAL NOTES:1823 east fort king street, suite 102 ocala, florida 34471p: (352) 620-0944 f: (352) 620-0996 www.sosarchitect.comflorida license: aa26002579 sosa@sosarchitect.comELECTRICAL SYMBOLSBID DOCUMENTS

874 Dixon BoulevardCocoa, FL 32922Phone: 321-636-0274Fax: 321-639-8986www.tlc-engineers.com Copyright 2012 TLC Engineering for Architecture, Inc.EB #15P1 - 47P1 - 34P1 - 73P1 - 62P1 - 59P2 - 16P2 - 16LP1 - 9LP1FLP1 - 11LP1 - 1325DHF-1EDH-2P2 - 11MECHANICAL ROOMP2 - 12114 P2 - 29,31RFFP2 - 11CLEAN ENTRY ROOM115P2 - 39,41P1WATER PURIFICATION116P1 - 20P1 - 31P1 - 16P1 - 29P1 - 27P1 - 14P1 - 25P1 - 23P1 - 12P1 - 67P1 - 17P1 - 21LP1 - 27 LP1 - 29P1 - 60P1 - 10P1 - 5LP1 - 10P1 - 52P1 - 65P1 - 52P1 - 65FFP2 - 11HALL126P2 - 26P2 - 11P1 - 64P2 - 11AC-1P1 - 73P1 - 56P2 - 26P1 - 56P1 - 71HEADHOUSE / WORKSHOP119P1 - 56P1 - 71JANITORIAL P2 - 19120EF-1 P2 - 47,49,51P2 - 1IDFP1 - 56P2 - 20P1 - 2P1 - 3COMP.121WPP2 - 9AHU-1P2 - 7P1 - 79,81,83SACPP2 - 5P2 - 3P2 - 5P2 - 8P2 - 2P1 - 73DHF-2MECHANICAL ROOM125P2 - 6FACPP2 - 4(2) #8; (1) #10 G;IN 2"C TO AC/CUEF-2P1 - 56COVERED ENTRY100FSFWOMENS RESTROOM123P1 - 4P2 - 8MENS RESTROOM124FFCFFFJLAB DIRECTOR OFFICE101SF-2EDH-1STORAGE ROOM118P1 - 54P1 - 5460/3EF-33 PERSON LAB OFFICE103P1 - 19P1 - 7P1 - 15P2 - 20P1 - 65P1 - 8P1 - 80,82,84FAAP-FLUSH MTD.P1 - 52P1 - 6104MEDIA PREP ROOM110P2 - 27P2P1 - 67LP1 - 25MULTIPURPOSE ROOM127FP2 - 7P1 - 58P1 - 48P2 - 48,50TO GENERATOR BATTERYCONNECTION AT GENERATORVERIFY WITH ELECTRICAL SITEPLAN.P1 - 69P1 - 58P2 - 43,45P2 - 44,46P1 - 69DHF-810 X 10 OHDP1 - 69P2 - 7CHFFP1 - 1P2 - 8P2 - 9C:\Users\stephen.cotton\Desktop\local revit projects\2014 projects\512050 budwood\512050-Budwood-R14-local.rvtNOTE:SEE DRAWING ES100 DATED 06/18/15FOR PROPOSED POWER FEEDS TO GREENHOUSES.VERIFY PANEL LOCATIONS WITH END-USER.7/10/2015 3:13:50 PMP2 - 81P2 - 22,24 CU-AC-1CU-2P2 - 33,35,3760/60N3RPOWER/SYSTEMS PLAN3/16" 1'-0"copyright C 2014P2 - 52,54P2 - 5project no.1422bydate04.24.15sheet no.E201NORTHTO GENERATOR HEATERCONNECTION AT GENERATORVERIFY WITH ELECTRICAL SITEPLAN.P2 - 53 GH STAFF OFFICE122A NEW PROJECT FOR:P2 - 9CITRUS REPOSITORY AT LA CROSSE, ALACHUA, FLORIDAFL DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICESP1 - 74,76,7860/3ATSW/ INTEGRALGEN. FDR.DISC.LP1 - 21 LP1 - 23LP1 - 15LP1 - 19LP1 - 17RECESSED. WALL TOBE 6"DEEP. COORDINATEWITH OTHER TRADES. EXTRACTION ROOMFFP1 - 18P2 - 27P1 - 63FP2 - 14 JP2 - 10JP1 - 63CLP1 - 9P2 - 17EXIT117CONFERENCE ROOM102P1 - 66FHALLWAY105J24P2 - 30THERMAL CYCLER ROOM106FP2 - 14P1 - 50P1 - 63P2 - 28LP1 - 9TESTINGGREENHOUSE & CONNECTIONBY GREENHOUSECONTRACTOR OPTION # 1P1 - 61STORAGE ROOM107P1 - 57P1 - 44P1 - 43CU-2P1 - 55P1 - 42P1 - 46P1 - 32P1 - 33P2 - 14 23CLEAN ENTRY HALL108BUDWOOD BUILDINGP1 - 22P2 - 13FP1 - 43P2 - 18PCR SET UP ROOM109CLEAN RESTROOM111P1 - 24P2 - 151823 east fort king street, suite 102 ocala, florida 34471p: (352) 620-0944 f: (352) 620-0996 www.sosarchitect.comflorida license: aa26002579 sosa@sosarchitect.comEF-4P1 - 75,77P1 - 35P1 - 75,77LP1 - 9GROW ROOM112P2 - 15P1 - 63FP2 - 10P2 - 21,23,25100/70N3RP1 - 63P1 - 61P1 - 45AC-2STG / TISSUE CULTURE ROOM113P1 - 53ALL RIGHTS RESERVED, THESEPLANS ARE PROTECTED BYCOPYRIGHT LAWS.UNAUTHORIZED USE MAYRESULTIN LEGAL ACTION.P1 - 45FCU-AC-2FFFP2 - 9WPP1 - 51P1 - 36 P1 - 495120501 2015-06-18 PRE-BID CLARIFICATIONP1 - 45P1 - 39 P1 - 28 P1 - 30 P1 - 41P1 - 26P1 - 40JP1 - 37P1 - 38P2 - 9WPTLC NO:BID DOCUMENTS

874 Dixon BoulevardCocoa, FL 32922Lighting Fixture ScheduleRequired LampsVoltage Type Lamp QuantityTypeDescriptionManufacturerModelA2TROFFER, FLUORESCENT, RECESSED, WITH .125 LENS, (2) F32T8 LAMPS, ELECTRONICBALLAST.TROFFER, FLUORESCENT, RECESSED, WITH .125 LENS, (2) F32T8 LAMPS, ELECTRONICBALLAST.BATTERY PACKEMERGENCY LIGHT, WITH BATTERY, TEST SWITCH.CEILING FAN.STRIP FLUORESCENT, SURFACE MOUNTED, 4' LONG, 2 LAMP, ELECTRONIC BALLAST.DOWNLIGHT, FLUORESCENT, RECESSED, 6"DIA, 1 LAMP, ELECTRONIC BALLAST.DOWNLIGHT, FLUORESCENT, RECESSED, 6"DIA, 1 LAMP, LENSED, ELECTRONIC BALLAST.DOWNLIGHT, FLUORESCENT, RECESSED, 6"DIA, 1 LAMP, LENSED, ELECTRONIC BALLAST,600 EMERGENCY BALLLAST.EXIT SIGN, CEILLING MOUNTED, RED LETTERS, CLEAR BACKGROUND AND SINGLE ORDOUBLE FACEEXIT SIGN, GREEN LETTERS, WALL MOUNTED, ALUMINUM HOUSING, AUTOTESTLightolierXP2GVA232120SO120 V32W T8264 VALightolierXP2GVA232120SO120 V32W T8264 ierVR26L24W12120 V12W 20120 V120 V120 V120 V32W T832W PL-T32W PL-T32W PL-T211124 VA30 VA64 VA36 VA36 VA36 VALightolierES-7-R120 VLEDCOOPER LIGHTINGAPC7-R120 VLEDPROVIDED WITHFIXTUREPROVIDED WITHFIXTUREEMFANJ2N1N1LN1LEXXEMXEMLP1 - 2A2LP1 - 1A2LP1 - 1A2LP1 - 1A2J2LP1 - 2J2LP1 - 2A2A2EEB #15A2A2A2EA2ELP1 - 2A2OSOSLP1 - 2LP1 - 2LP1 - 2XEMLP1 - 1OSA2XLP1 - 2LP1LP1 - 2A2OS3A2EA2LP1 - 23OSLP1 - 2A2XLP1 - 1 LP1 - 2LP1 - 1LP1 - 2A2XOSXA2A2A2LP1 - 23A2LP1 - 3LP1 - 2OSA2LP1 - 1512050LP1 - 2LP1 - 3LP1 - 1TLC NO:10 VA NUMBER OF FACES AND CHEVRONS AS INDICATED ON PLANSOSLP1 - 1 Copyright 2012 TLC Engineering for Architecture, Inc.10 VAA2A2LP1 - 1Comments1823 east fort king street, suite 102 ocala, florida 34471p: (352) 620-0944 f: (352) 620-0996 www.sosarchitect.comflorida license: aa26002579 sosa@sosarchitect.comA2EVAPhone: 321-636-0274Fax: 321-639-8986www.tlc-engineers.comLP1 - 2A2LP1 - 2LP1 - 23a 3bLP1 - 3XLP1 - 2OSLP1 - 3LP1 - 3X33XLP1 - 13A2A2LP1 - 1LP1 - 1A2bLP1 - 3LP1 - 1A2bLP1 - 3A2bLP1 - 3A2A2LP1 - 3LP1 - 3A2LP1 - 3LP1 - 3OSLP1 - 1J2LP1 - 4J2LP1 - 4A2A2EA2A2LP1 - 1N1LP1 - 4LP1 - 1XEMA2A2A2aLP1 - 3LP1 - 3LP1 - 1A2A2aLP1 - 33a 3bA2LP1 - 3LP1 - 3XEMLP1 - 3XEMLP1 - 3OSOSA2aA2LP1 - 3LP1 - 3XEMLP1 - 33N1LLP1 - 7333XEMLP1 - 4LP1 - 4LP1 - 4OSOSXEMFANJ2LP1 - 5J2FANLP1a -5LP1 - 6bOSJ2XEMLP1 - 5aaFANLP1 - 5J2LP1 - 5N1LLP1 - 8LP1 - 8J2A2LP1 - 4N1LLP1 - 7J2J2LP1 - 8LP1 - 8A2EaFANA2J2A2aLP1 - 5OSEMLP1 - 8A2LP1 - 8LP1 - 8LP1 - 6bJ2A2LP1 - 4LP1 - 5LP1 - 6baJ2aLP1 - 5J2A2LP1 - 4OS3aJ2LP1 - 5N1LLP1 - 8LP1 - 6bLP1 - 53bJ2LP1 - 8LP1 - 4N1LELP1 - 7OSLP1 - 5LP1 - 4XLP1 - 4A2EaLP1 - 5XEMLP1 - 5EMLP1 - 8J2J2LP1 - 8LP1 - 8A2A2LP1 - 8LP1 - 4LP1 - 8J2J2LP1 - 8LP1 - 8LP1 - 4A2LP1 - 4LP1 - 4copyright C 2014LP1 - 4OSLP1 - 43a 3bC:\Users\stephen.cotton\Desktop\local revit projects\2014 projects\512050 budwood\512050-Budwood-R14-local.rvtA2OSOSLP1 - 47/10/2015 3:13:51 PMA2A2ECITRUS REPOSITORY AT LA CROSSE, ALACHUA, FLORIDAFL DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICESA2BUDWOOD BUILDINGA2LIGHTING PLAN3/16" 1'-0"ALL RIGHTS RESERVED, THESEPLANS ARE PROTECTED BYCOPYRIGHT LAWS.UNAUTHORIZED USE MAYRESULTIN LEGAL ACTION.A2A NEW PROJECT FOR:A2EOSproject no.1422bydate04.24.15sheet no.E202NORTHA2N1LELP1 - 7BID DOCUMENTS

Branch Panel: LP1Location:Supply From: P1Mounting: SurfaceEnclosure: Type 1GENERAL NOTES:874 Dixon BoulevardCocoa, FL 32922Branch Panel: P2Volts: 120/208 WyePhases: 3Wires: 4A.I.C. Rating:Mains Type: MCBMains Rating: 225 AMCB Rating: 100 ANeutral Rating:Location:Supply From: P1Mounting: SurfaceEnclosure: Type 1Notes:Volts: 120/208 WyePhases: 3Wires: 4Phone: 321-636-0274Fax: 321-639-8986www.tlc-engineers.comA.I.C. Rating: 22kMains Type: MCBMains Rating: 250 AMCB Rating:Neutral Rating: Copyright 2012 TLC Engineering for Architecture, Inc.EB #15Notes:TLC NO:5120501. PROVIDE 1"C / WIRING TO GENERATOR TO EACH ATS CONTROL INPUT.A0.9 kVABC1.0 kVA1.2 kVA1.1 kVA0.7 kVA0.1 kVA0.9 kVA0.8 kVA2.4 kVA0.2 kVA0.2 kVA0.0 kVA0.1 kVA0.0 kVA0.0 kVA0.3 kVA0.0 kVA0.3 kVA0.2 kVA0.0 kVA0.0 kVA0.1 kVA0.4 kVA0.2 kVA0.0 kVA0.0 kVA0.4 kVA0.0 kVAPole111111111111111NotTrip e20 A20 A20 A20 A20 A20 A20 A20 A20 A20 A20 A20 A20 A20 A20 ACircuit DescriptionLighting - 105, 106, 107, 108, 109Lighting- -114, 116, 126, 127Ceiling Fans - Headhouse/Workshop 119Lighting - 121, 122, 123, 124, 125Hood - Extraction Room are6.2 kVA53 A1.4 kVA 0.0 kVA2.9 kVA24 AConnected LoadDemand FactorEstimated DemandLighting5.9 kVA125.00%7.4 kVAOtherReceptacle0.0 kVA6.8 kVA0.00%100.00%0.0 kVA6.8 kVALighting - Dwelling Unit0.0 kVA100.00%0.0 kVATotal Conn. Current: 36 AEmergency Lighting0.1 kVA125.00%0.1 kVATotal Est. Demand Current: 40 ALoad Classification3.8 kVA32 1618202224262830Panel TotalsCircuit DescriptionReceptacle - Comp.Receptacle - Comp.Receptacle - Womens RR 123, Mens RR 124Receptacle - Multipurpose RoomReceptacle - ExteriorReceptacle - Hallway 126 , 115, 112Computer - PCR Set Up Room 109Receptacle - STG / Tissue Culture Room 113Receptacle - Media Prep Room 110RCP-1Notes:1. Provide type written directory stating specific load and location.Pole1111111111CU-135KMCB800 A800 A7/10/2015 3:13:53 PM1.3 kVA100 A 3Autoclave - Media Prep Room 110Minus 20 Freezer - Extraction Room 104Sliding Door Refrigerator - Extraction Room 104Autoclave - Media Prep Room 110Heated Stirplate - Media Prep Room 110Microwave Oven - Media Prep Room 110PH Meter - Media Prep Room110Top Loading Balance - Media Prep Room 110Water Purification System - Water Purification 116Large Hood - STG / Tissue Culture Room 113Incubators - STG / Tissue Culture Room 113Sliding Door refrigerator - STG / Tissue Culture.Incubator - STG / Tissue Culture Room 11320 A20 A20 A20 A20 A20 A20 A20 A20 A40 A20 A20 A20 A1111111111111Incubator - STG / Tissue Culture Room 113Receptacle - Grow Room 112Receptacle - Grow Room 112Vortexer - PCR Set Up Room 109Flow Hood - PCR Set Up Room 109Flow Hood - PCR Set Up Room 109UPS - PCR Set Up Room 109Thermocycler - Storage Room 107Computer/Monitor - Storage Room 107UPS - Storage Room 107Receptacle - Thermal Cycler Room 106Receptacle - Conference Room102Receptacle - Lab Director Office101Receptacle - 3 Person Lab Office103Receptacle - Headhouse/Workshop 119Receptacle - Janitor 120EF20 A20 A20 A20 A25 A25 A20 A20 A20 A20 A20 A20 A20 A20 A20 A20 A20 A11111111111111111AC2 - Grow Room 112 CU-2-235 A 20.0 kVA0.6 kVA3.6 kVA1.4 kVA1.4 kVA0.0 kVA0.0 kVA1.4 kVA0.7 kVA1.4 kVA0.7 kVA0.6 kVA0.3 kVA0.0 kVA2.4 kVA0.4 kVA2.4 kVA0.6 kVA0.3 kVA1.1 kVA1.0 kVA0.7 kVA0.4 kVA0.3 kVA0.6 kVA0.4 kVA1.0 kVA0.2 kVA0.6 kVA0.6 kVAThermocycler - Storage Room 107Computer/Monitor - Storage Room 107UPS - Storage Room 107Refrigerator - Multipurpose Room 127Receptacle - Thermal Cycler Room 106Receptacle - Lab Director Office 101Receptacle - 3 Person Lab Office 103Receptacle - Headhouse/Workshop, Chemical Roo.Receptacle - 3 GH Staff Office 122Hood - Extraction Room 104Computer - Thermal Cycler Room 106ReceptacleComputer - Thermal Cycler Room 1063 250 A27.4 kVA0.4 kVA27.8 kVA1.8 kVA5.0 kVA3 60 A5.0 kVA2.1 kVA61.8 kVA515 A3 60 A4.0 kVA67.9 kVA568 464850525456586062646668P2 707274EDH-2 767880EDH-1 82844.0 kVA35 A 3Total Amps:20 A20 A20 A20 A20 A20 A20 A20 A20 A25 A20 A20 A20 A5.0 kVA1.8 kVA2.1 kVA1.1 kVA 1110.3 kVA 1110.8 kVA 1112.4 kVA 1110.4 kVA 1NotTrip eCircuit Description20 ASliding Door Refrigerator - 3 GH Staff Office 12220 ARefrigerator - 3 GH Staff Office 12220 AMinus 20 Freezer - Extraction Room 10420 ASliding Door Refrigerator - Extraction Room 10420 AKlecoTissue Proc - Extraction Room 10420 AHeated Stirplate - Media Prep Room 11020 AOmnispence Liquid Dispencer - Media Prep Room.20 ATop Loading Balance - Media Prep Room 11020 ARefrigerator - Media Prep Room 11020 AWater Purification System - Water Purification 11620 ALarge Hood - STG / Tissue Culture Room 11320 AIncubators - STG / Tissue Culture Room 11320 ASliding Door Refrigerator - STG / Tissue Culture.20 AIncubator - STG / Tissue Culture Room 11320 AIncubator - STG / Tissue Culture Room 11320 AComputer/Monitor - PCR Set Up Room 10920 AVortexer - PCR Set Up Room 10920 AMini Centrifuge - PCR Set Up Room 10920 AMinus 20 Freezer - PCR Set Up Room 10920 AComputer/Monitor - PCR Set Up Room 10930.0 kVA0.6 kVA0.0 kVA0.0 kVA0.6 kVA1.4 kVA0.4 kVA1.4 kVA0.2 kVA3.6 kVA1.3 kVA0.2 kVA1.3 kVA0.1 kVA0.1 kVA0.3 kVA0.1 kVA1.8 kVA1.7 kVA1.4 kVA0.7 kVA1.8 kVA1.3 kVA0.6 kVA1.0 kVA6.2 kVA2.9 kVAAHU-20.3 kVA

fluorescent fixture a designation . or incandescent fixture fluorescent, or incandescent wall washer. exit light fixture direction arrows as shown (shaded quadrant indicates face(s) of fixture) . underwriters laboratories, inc. pub