DMP & INTERLOGIX Product Comparison Guide

Transcription

DMP & INTERLOGIXProduct Comparison GuideDMP products offer solutions to multiple access control, burglary, and fire security applications. The DMP family compares well with manyexisting products from competitor companies. This document identifies the features and capabilities of DMP products and compares them tocompetitor products.Note: The comparison information included in this guide is from competitor distributors, equipment manufacturers, and their publisheddocumentation. DMP is not responsible for errors, changes, or out-of-date information.DMP XTL SeriesSYSTEM CONTROL PANELZONE INFORMATIONDMP XTL SERIESULTRASYNC SELF CONTAINED HUBUTC SIMON XTIWireless Zones996440Hardwire Zones042Wireless Zone Frequency Range900 MHz Spread Spectrum319.5 MHz319.5 MHzNominal Wireless Range for Transmitters toReceiver (Feet)1200500500742Attrition DetectionYesNoYesUser check InYesNoYesProgrammable Inactivity Monitor to watchfor on-site activityYesYesNo activity reportUser Codes992561 duress 8 user codesSchedulesOpening/CIosing Schedules96-On-premise App with Wi-Fi ConnectivityNoYes-Event Memory200102440Areas or Partitions6 (Areas)4 (Partitions)2 (Partitions)Smash & GrabNot requiredYesYesRemote Sounders8--Remote Update for Firmware via Cell orNetworkYesYes-Arming SystemsAll-Perim, Home-Sleep-Away, AreaSleep/Away/NightStay/AwayLTELTELTEChime alertsOn/OffYesYesSiren or Sounder110 dB85 dB internal80 dB internalWi-Fi in PackageYesYesNoCommunication Path to Main ControllerTwo-way wirelessWi-FiTwo-way wirelessWi-Fi Built-InYesYesNoAll-in-one console design or DistributedWirelessDistributedConsoleConsoleZ-Wave Built-inYesYesNoZ-Wave Interface in PackageYesYesNoANSI/UL 1023 Household BurglarYesYesYesANSI/UL 1610 Central Station BurglarYesYes-ANSI/UL 1635 Digital BurglarYesYesYesANSI/SIA CP-01-2010 False Alarm Reduction YesYes-ANSI/UL 985 Household FireYesYesYesCalifornia State Fire NoYesKEYPAD/ACCESS INFORMATIONRemote KeypadsDMP FEATURESUSER INFORMATIONSYSTEM INFORMATIONCOMMUNICATIONCellular Communicator ModuleAUDIBLE DEVICESWIFI COMMUNICATIONADDITIONAL FEATURESCOMPLIANCE LISTINGSMANUFACTURED IN U.S.A.WITH U.S. AND GLOBAL COMPONENTSLT-2084 19434 2019 Digital Monitoring Products, Inc.YesNoNo

DMP XT30SYSTEM CONTROL PANELZONE INFORMATIONDMP XT30NX4Zones428Control Panel Zones104Control Panel Fire Zones1-Hardwired Expansion Zones324Wireless Expansion Zones288Powered Smoke Zones1-Supervised Keypads8 hard-wired or wireless8Unsupervised KeypadsUnlimited (hard-wired only)UnlimitedDoors of Access80Wiegand Input KeypadsYes0Keypad ProgrammableYesYesKeypad Compatible with all ProductsYesYesAuxiliary Power600 mA1 AmpBell Power1.5 A1 AmpAuxiliary Output4 fully programmable4User Codes/Access Cards308Event Memory100185User Check InYes-Individual Zone MonitorYesYesControl by an AppYes (Virtual Keypad)Yes (Alarm.con, addition fee-based service)Attrition DetectionYes-Programmable Inactivity MonitorYes-Areas or Partitions6 (Areas)1 (Partition)Arming /NIghtRemote Access CompatibleYesYesDigital DialerSDLC, CIDSIANetwork CommunicationsYes, built-in-Cellular SupportLTE (Verizon or AT&T)Alarm.comWireless Arm/DisarmYes-Wireless Types SupportedDMP 1100 Series-Ademco - Inovonics - ITI-California State Fire MarshalYesYesANSI/UL 985 Household Fire WarningYesYesANSI/UL 1023 Household BurglarYesYesANSI/UL 1610 Central Station BurglarYesYesANSI/UL 1635 Digital BurglarYes-SIA-CP-01-2010 False Alarm ReductionYesYesKEYPAD/ACCESS INFORMATIONPOWER & OUTPUT INFORMATIONUSER INFORMATIONDMP EXCLUSIVE FEATURESSYSTEM INFORMATIONCOMMUNICATIONWIRELESS INFORMATIONCOMPLIANCEMANUFACTURED IN U.S.A.WITH U.S. AND GLOBAL COMPONENTSLT-2084 19434 2019 Digital Monitoring Products, Inc.YesNo

DMP XT50SYSTEM CONTROL PANELZONE INFORMATIONDMP XT50NX6Zones5816Control Panel Zones106Control Panel Fire Zones1-Hardwired Expansion Zones326Wireless Expansion Zones4816Powered Smoke Zones1-Supervised Keypads8 hard-wired or wireless (See LT-0980)16Unsupervised KeypadsUnlimited (hard-wired only)UnlimitedDoors of Access82Wiegand Input KeypadsYes0Keypad ProgrammableYesYesKeypad Compatible with all ProductsYesYesAuxiliary Power600 mA1 AmpBell Power1.5A1 AmpAuxiliary Output4 fully programmable4User Codes/Access Cards9916Event Memory200512User Check InFirst/Last/Scroll-Keypad-Individual Zone MonitorYesYesControl by an AppYes (Virtual Keypad)Yes (Alarm.com, addition fee-based service)Attrition DetectionYes-Programmable Inactivity MonitorYesYesAreas or Partitions6 (Areas)2 (Partitions)Arming /NightRemote Access CompatibleYesYesPhone Cable MonitorYesYesDigital DialerSDLC, CID-Network CommunicationYes, built-in-Cellular SupportLTEAlarm.comWireless Arm/DisarmYes-Wireless Types SupportedDMP 1100 Series - Ademco - Inovonics - ITI-California State Fire Marshal (CSFM)Yes-ANSI/UL 985 Household Fire WarningYesYesANSI/UL 1023 Household BurglarYesYesANSI/UL 1610 Central Station BurglarYesYesANSI/UL 1635 Digital BurglarYes-SIA-CP-01-2010 False Alarm ReductionYesYesKEYPAD/ACCESS INFORMATIONPOWER & OUTPUT INFORMATIONUSER INFORMATIONDMP EXCLUSIVE FEATURESSYSTEM INFORMATIONCOMMUNICATIONWIRELESS INFORMATIONCOMPLIANCEMANUFACTURED IN U.S.A.WITH U.S. AND GLOBAL COMPONENTSLT-2084 19434 2019 Digital Monitoring Products, Inc.YesNo

DMP XR150SYSTEM CONTROL PANELZONE INFORMATIONDMP XR150NX8CONCORD 4Zones1424896Control Panel Zones10896Control Panel Fire Zones2--Hardwired Expansion Zones1324896Wireless Expansion ZonesDMP 1100 Series (100 Zones)4896Zone Expansion Bus(es)Keypad (32 zones) 1 onboard LX-Bus (100zones per bus) up to 15,000 foot bus using710 bus splitter repeater module and remotepower supplies. No more than a 2 Vdc dropover entire data bus at this distance. Usestandard 18 AWG 4 conductor non-shieldednon-twisted wire.40-Powered Smoke Zones2 onboard, expandable to 102--Maximum 2-Wire Smoke Detectors10 (2W-B, 2WT-B) per zone, maximum 130zones-2- and 4-WireSupervised Keypads864-Unsupervised KeypadsUnlimitedUnlimited-Doors of Access88-Wiegand Input KeypadsYes--Keypad ProgrammableYesYes-Keypad Compatible with all productsYesYes-Auxiliary Power1.5A1 Amp1 AmpBell Power1.5AShared with Aux Power-Maximum Ah of Batteries supported byControl Panel67 amp hours of batteries supported--Auxiliary Output2 Form C, 4 open collector outputs onboardexpandable to 100 outputs off board-1 AmpUser Codes/Access Cards10,00099230Event Memory12,000 events, 10,000 access events, and2000 system events512-Event SortView opening/closings, zone events, usercode and schedule changes, door access, andsupervisory events. Sort by user, door, anddate range via keypad or remote PC Access.Attach up to 8 schedules to up to 15events.Two-way Voice Listen-inEagle Products-Alarm.comZone MonitorYesYes-ReportingCID, Serial 3SIA & CID-Reporting Paths83 Built-In-Areas or Partitions8 (Areas)8 (Partitions)6 (Partitions)Arming SystemsArea/All-Perimeter,Home-Sleep-Away, also Area Arming featurescommon area and Armed Area FirstLevel 1 (off), Level 2 (stay), and Level3 (away)Remote Access CompatibleRemote Link and System LinkDL-900 SoftwareYesPhone Cable MonitorYesYes-Digital DialerYesYes-Network CommunicationsYes, built-inAdd on-Cellular CommunicationsLTEAdd on-Wireless Arm/DisarmYes up to 4 wireless keypads and 50 wirelesskey fobsYes (1 a zone)-Wireless Types SupportedDMP 1100 Series Wireless —up to 100 zones319.50 up to 48-Processor32 bit processor with built in 10/100Base Ton network version8 bit-KEYPAD/ACCESS INFORMATIONPOWER & OUTPUT INFORMATIONUSER INFORMATIONSYSTEM INFORMATIONCOMMUNICATIONWIRELESS INFORMATIONLT-2084 19434 2019 Digital Monitoring Products, Inc.

DMP XR150 (continued)SYSTEM CONTROL PANELADDITIONAL FEATURESDMP XR150NX8CONCORD 4Door Lock, Unlock, & Lock Down FeatureBy Keypad Menu orSystem Link Remote Link--Z-Wave Control140 Z-Wave device support using 738ZplusmoduleYes, thru Z-Wave enabled cellmodules-Schedules for Areas, Doors, Outputs,Z-Wave, & ProfilesStart/End Date & Time with up to 99 scheduletimes assignable. Schedule time may be usedfor multiple functions such as auto arming, doorschedules, user schedules, relay schedules etc.--Ethernet Support on Network Panels10/100baseT--User Code AuditYes--Dedicated XBUS (Wireless)Separate from LX BusYes--Temporary CodeEnd Date & Time--SchedulesStart/End Date & Time with up to 99 scheduletimes assignable. Schedule time may be usedfor multiple functions such as auto arming, doorschedules, user schedules, relay schedules etc.-Time with Light control, Outputs,Arming, Opening & closing,Latchkey paging, and Notify byexception.CSFM California State Fire MarshalYes--FDNY New York CityYes--ANSI/UL 294 Access Control System UnitsYesYes-ANSI/UL 365 Police Connected BurgYesYes-ANSI/UL 609 Local BurglarYesYes-ANSI/UL 864 Fire Protective Signaling 9thEditionYes--ANSI/UL 985 Household Fire WarningYesYes-ANSI/UL 1023 Household BurglarYesYes-ANSI/UL 1076 Proprietary BurglarYes--ANSI/UL 1610 Central Station BurgYesYes-ANSI/UL 1635 Digital BurglarYesYes-SIA-CP-01-2010 False Alarm ReductionYes--NIST CertificationYes (XR550E)--ULC-S304 Standard for Central andMonitoring Station Burglar Alarm Units.Yes--ULC-S545 Standard for Residential FireWarning System Control UnitsYes--ULC-S559 Fire Signal Receiving CentresSystemsYes--ULC Subject-C1023 Household Burglar Alarm YesSystem Units--ULC/ORD-C1076 Standard for ProprietaryBurglar Alarm Units and Systems--COMPLIANCEMANUFACTURED IN U.S.A.WITH U.S. AND GLOBAL COMPONENTSLT-2084 19434 2019 Digital Monitoring Products, Inc.YesYes--

DMP XR550SYSTEM CONTROL PANELZONE INFORMATIONDMP XR550VEREX MONITOR XLZones574256Control Panel Zones10-Control Panel Fire Zones2-Hardwired Expansion Zones564-Wireless Expansion ZonesDMP 1100 Series (500 Zones)-Zone Expansion Bus(es)Keypad (64 zones) 5 on-board LX bus (100 zones per bus) up to 15,000foot bus using 710 bus splitter repeater module and remote powersupplies. No more than a 2 Vdc drop over entire data bus at this distance.Use standard 18 AWG 4 conductor non-shielded non-twisted wire.-Zone expander /716-Powered Smoke Zones2 onboard, expandable to 502-2-Wire Smoke Detectors10 (2W-B, 2WT-B) per zone, Maximum 562 zones-Supervised Keypads1660Unsupervised KeypadsUnlimited-Doors of AccessMaximum of 96 doors (requires firmware version 111 or higher)Prime: 16KEYPAD/ACCESS INFORMATIONEnterprise & Enterprise Elite: 250 XLPanels with up to 32 doors each (8,000doors total)Wiegand Input KeypadsYesYesFully Keypad ProgrammableYesYesKeypad Compatible with all productsYesYesAuxiliary Power1.5 A-Bell Power1.5 A-Ah of Batteries supported by Control Panel67 Amp hours of batteries supported-Auxiliary Output2 Form C, 4 Open Collector outputs onboard expandable to 500 outputsoff board-10,000Base Prime Model: 1,000POWER & OUTPUT INFORMATIONUSER INFORMATIONUser Codes/Access CardsBase Enterprise Model: 4,000 (or up to64,000 w/additional memory)Event Memory12,000 events 10,000 access events and 2,000 system eventsEvent SortView opening/closings, zone events, user code and schedule changes,door access, and supervisory events. Sort by user, door, and date range viakeypad or remote PC Access.Phone ControlVia AppVia text messaging2 Way Voice Listen-inEagle Products-Zone MonitorYes-ReportingCID, Serial 3SIA, CID, SIP 1Reporting Paths8-Areas or Partitions32 (Areas)16 (Partitions)Arming SystemsArea/All-Perimeter, Home-Sleep-Away, also Area Arming featuresCommon Area and Armed Area FirstOn/Stay/OffRemote Access CompatibleYesRemote Link and System LinkYesPhone Cable MonitorYes-Digital DialerYesYesNetwork CommunicationsYes, built-in-Cellular CommunicationsLTE-Wireless Arm/DisarmYes up to 4 wireless keypads and 50 wireless key fobs-Wireless Types SupportedDMP 1100 Series Wireless — up to 500 zones-Processor32 bit processor with built in 10/100Base-T on network version-256SYSTEM INFORMATIONCOMMUNICATIONWIRELESS INFORMATIONLT-2084 19434 2019 Digital Monitoring Products, Inc.

DMP XR550 (continued)SYSTEM CONTROL PANELBANKING FEATURESDMP XR550DVEREX MONITOR XLEncryptionYes-Panic TestYes-Network OptionsYes-PassphraseYes-Card plus PIN by AreaYesYesEarly Morning AmbushYes-Bank Safe & VaultYesYesTwo Man RuleYesYesDoor Lock, Unlock, & Lock Down FeatureBy Keypad Menu orSystem Link Remote Link-140 Z-Wave device Support using 738ZModuleYes-Schedules for Areas, Doors, Outputs,Z-Wave, & ProfilesStart/End Date & Time with up to 99 schedule times assignable. Scheduletime may be used for multiple functions such as auto arming, doorschedules, user schedules, relay schedules etc.50-250Ethernet Support on Network Panels10/100 Base T-User Code AuditYes-Dedicated XBus (Wireless)Separate from LX BusYes-Temporary CodeEnd Date & TimeService Pin ModeADDITIONAL FEATURESEscort Required ModeHoliday DatesStart/End Date & Time with up to 99 schedule times assignable. Scheduletime may be used for multiple functions such as auto arming, doorschedules, user schedules, relay schedules etc.50 - Schedule in Schedule, 15 minutesprior to In Schedule, 15 minutes prior toOut of Schedule, or No AccessCSFM California State Fire MarshalYes-FDNY New York CityYes-ANSI/UL 294 Access Control System UnitsYes-ANSI/UL 365 Police Connected BurgYes-ANSI/UL 609 Local BurglarYes-ANSI/UL 864 Fire Protective Signaling 9thEditionYes-ANSI/UL 985 Household Fire WarningYes-ANSI/UL 1023 Household BurglarYes-ANSI/UL 1076 Proprietary BurglarYes-ANSI/UL 1610 Central Station BurgYes-ANSI/UL 1635 Digital BurglarYes-SIA-CP-01-2010 False Alarm ReductionYes-NIST CertificationYes-ULC-S304 Standard for Central andMonitoring Station Burglar Alarm UnitsYes-ULC-S545 Standard for Residential FireWarning System Control UnitsYes-ULC-S559 Fire Signal Receiving CentresSystemsYes-ULC Subject-C1023 Household Burglar AlarmSystem UnitsYes-ULC/ORD-C1076 Standard for ProprietaryBurglar Alarm Units and SystemsYes-COMPLIANCEMANUFACTURED IN U.S.A.WITH U.S. AND GLOBAL COMPONENTSLT-2084 19434 2019 Digital Monitoring Products, Inc.YesNo

Event Memory 100 185 User Check In Yes - Individual Zone Monitor Yes Yes Control by an App Yes (Virtual Keypad) Yes (Alarm.con, addition fee-based service) DMP EXCLUSIVE FEATURES Attrition Detection Yes - Programmable Inactivity Monitor Yes - SYSTE