RESIDUAL GAS ANALYSISMass Spectrometersfor Residual Gas AnalysisApplications (RGA)

MASS SPECTROMETERSfor Residual Gas Analysis Applications (RGA)Residual gas analysers (RGA) provide a unique window intothe vacuum environment for contamination monitoring, leakdetection and analysis of the species of interest within thevacuum chamber, water vapour for example. The Hidenresidual gas analysers are quadrupole mass spectrometersconfigured in a broad range of products to addressapplications in vacuum processing, science and technology.Hiden residual gas analysers are equipped with software that isintuitive and multi-level offering simple fail-safe* operation fora novice user whilst incorporating a broad range of useful andadvanced features for the vacuum expert.THE VACUUM RESIDUALS ROUTINELYANALYSED INCLUDE:Hydrogen, measured at mass 2, and of specific interest inUHV where outgassing can be the limiting factor for achievingultimate vacuum.Volatile Organic Compounds, measured at species specificmasses including mass 78 for benzene, 91 for toluene, 31 forethanol, and 45 for isopropyl alcohol.Hiden’s residual gas analysers analyse the above species with areal-time data display to give the vacuum user immediateand updated information about the health and trends of thepartial pressure of the key vacuum residuals. Data is used forroutine vacuum chamber monitoring, leak detection, for analysisof vacuum processes, and for advanced research studies.WHAT OUR CUSTOMERS SAY:“ . I strongly feel (based on experience) that, products supplied byHiden can be fully relied upon for their quality and reliabilityand equally well for the support from the Hiden family, right fromthe point of planning to the point of implementation.”Helium, measured at mass 4, and used as a search gas for leakdetection. Hiden residual gas analysers include a dedicated leakdetect mode, for fast response analysis of helium.Water Vapour, measured at mass 18, is the most difficultresidual to pump to UHV level without baking or pumping thevacuum chamber for extended periods.Nitrogen and Oxygen, measured at mass numbers 28 and32, with additional peaks measured for confirmation at massnumbers 14 and 16. The measurement of significant signal forthe ‘air peaks’ is often the first indication of a chamber leak.Hydrocarbons are analysed at several masses across amass scan and typically can be identified at mass numbers69 and 71, 55 and 57, 41 and 43, and 15 for alkanes andalkenes. The residual gas analyser broad mass scan with highsensitivity allows the user to get detailed information regardingthe contamination level of the chamber.B Mass Spectrometers for Residual Gas Analysis (RGA)* On board safety features include overpressure protection for both filamentand detector by internal measurement as well as connection for an externaloverpressure protection device.

ContentsRGA SERIES - IntroductionHALO - for Residual Gas AnalysisHAL/3F - Triple Filter Mass Spectrometer for Analytical ApplicationsHAL/3F PIC - Triple Filter Mass Spectrometer with Pulse Ion Counting Detectionfor Fast Event StudiesRGA ANALYSER DIMENSIONSION SOURCE OPTIONSHMT - High Pressure Residual Gas AnalyserHAL/3F PICHAL 201 RC - for Demanding UHV ApplicationsqRGA - for Fusion ResearchHALO 201 MBE - for Molecular Beam Epitaxy ApplicationsXBS - Deposition Rate Monitor for Molecular Beam Analysis & Deposition Control3F PIC - for UHV TPDEPIC & IDP - for UHV Analysis of Neutrals, Radicals & Ions3F SERIES 1000 - for High Precision Scientific & Process ApplicationsRGA CONTROL SOFTWARE - MASsoft, netMASsoft, Advanced Software FeaturesHMTGold plated ion source.Mass Spectrometers for Residual Gas Analysis (RGA) 1

RGA SERIESAll Hiden residual gas analysers are application tested and calibrated to provide thehighest quality performance, and they are backed by a 3 year warranty and lifetimeservice support.vacuum diagnosticsmolecular beam studiesreactive sputtering closed loop controlsemiconductor productionleak detectionUHV/XHV surface sciencevacuum furnace monitoringvacuum process analysiscontamination analysisUHV TPDTHE HIDEN RGA SERIES INCLUDES THREE SPECIFICATION LEVELS:HALO 100 RCHALO - for residual gas analysis.HAL/3F - triple filter mass spectrometers for analytical applications. HAL/3F PIC - pulse ion counting detection for fast event studies.HAL/3FCORE FEATURES/OPTIONS:mass range options: 50, 100, 200, 300, 510 amuultra fast data acquisition - up to 650 measurementsper secondtwin burnout-resistant oxide coated iridium filamentsreal-time background subtractembedded web server with netMASsoft Java applet enables simplified RGA operation from a web browserrange of ion source and shroud optionsintegral mass libraryadvanced analysis capability for complex gas interpretationhigh sensitivity helium leak detection, mass selectable foralternative search gases2 Mass Spectrometers for Residual Gas Analysis (RGA)HAL/3F PIC

HALOfor Residual Gas Analysisvacuum fingerprint: histogram & peak profile scantrend analysis: monitor multiple species 80 partialpressure values in real-timeleak detectionzero blast baseline drift is eliminated: compare andanalyse vacuum chamber residual gas/vapour speciesDetector options:- Faraday-only, Faraday/Electron MultiplierSensitivity with:- Faraday - detection to 1x10-11 mbar- Electron Multiplier - detection to 2x10-13 mbarMaximum Operating Pressure:- 1x10-4 mbarHelium in Air at 5 ppm - high sensitivity with stablebackground - even at high pressure1086HALO 201 RC4201FEATURES:23456Hiden’s RGA sensitivity for helium is 5 times* that of a typical analyser providingexcellent leak detection performance.mass range options: 100, 200 and 300 amudetector options: Faraday or Faraday and Electron MultiplierPC Windows controlledAutomated Electronic Beam Shutter EBS optimises noise suppressionAutomatic DeSat mode for high speed scanningeven in the presence of saturating signals*Based on reference to published relative sensitivity data.Mass Spectrometers for Residual Gas Analysis (RGA) 3

HAL/3FTriple Filter Mass Spectrometerfor Analytical ApplicationsPre-filterMass SelectivePrimary FilterPost FilterTriple Filter Assembly.3F Performance includes enhanced sensitivity for high mass species andincreased resolution capabilitiestriple mass filter technology for high sensitivity withenhanced contamination resistance and abundancesensitivityapplication-specific ionisation sources for gas analysis,molecular beam measurement and UHV/XHV studiesMass range options:- 50, 200, 300 and 510 amu- Series 1000 for mass range options up to 1000 amu-S ensitivity with Faraday and Single Channel Electron MultiplierDetectors – 2x10-14 mbarFEATURES:mass range options: 50, 200, 300 and 510 amudetector: Faraday and Single Channel Electron Multiplierfull control of field axis potential: ion source emission,electron energy, ion energyAutomated Electronic Beam Shutter EBS optimises noise suppressionAutomatic DeSat mode for high speed scanningeven in the presence of saturating signals4 Mass Spectrometers for Residual Gas Analysis (RGA)Maximum operation pressure:- 1x10-4 mbar

HAL/3F PICTriple Filter Mass Spectrometer with Pulse IonCounting Detection for Fast Event StudiesPulse ion counting detection for fast event studiesincluding UHV TPD and for transient gas analysis7 decade continuous measurement from 1 c/s to 107 c/sMulti-channel scaler detector option with timeresolution to 50 nanosecondsMass range options:- 50, 300 and 510 amu- Series 1000 for mass range options up to 1000 amu- Sensitivity with pulse ion counting detector 5x10-15 mbarMaximum operation pressure:- 5x10-6 mbar- 1x10-4 mbar with Faraday optionHAL/3F PICHigh quality transient data acquisition at PPM/PPB levels. Ideal for UHV TPD.FEATURES:7 decade dynamic range 650 measurements per seconddetection to 5x10-15 mbarsignal gating for pulsed studiesmulti-channel scaler option with 50 nanoseconds timeresolutionPCA mode - Predictive count accumulation mode.Significantly extends electron multiplier life.Mass Spectrometers for Residual Gas Analysis (RGA) 5

RGA ANALYSER DIMENSIONSHALO Analyser and RF HeadHAL/3F Analyser and RF HeadHAL/3F PIC Analyser and RF6 Mass Spectrometers for Residual Gas Analysis (RGA)

ION SOURCE OPTIONSHiden Analytical produces a wide variety of ion source types which can be fitted toour full range of RGAs. Ion source types are crucial to the performance of RGAs andhaving the ability to specify which source you require ensures our RGAs are customconfigured for specific applications.ION SOURCE OPTIONSStandard RGA - A radially symmetric configuration for general applications.Standard and UHV low profile sources.UHV Low Profile - Optimised for UHV TPD studies enabling closer proximity of theion source to the evolution surface.Closed Sources - For high pressure studies with direct gas input used in conjunctionwith a differential pumping stage for the analyser.XBS Cross Beam - The XBS Cross Beam is configured specifically for MBEdeposition rate monitoring and control.Standard and UHV low profile gold sources.Basic Cross Beam - The Basic Cross Beam source is used for analysis of molecularbeams, where the beam may be liable to condense on ioniser surfaces. The sourcefeatures an unobstructed pathway through the ionising region of the source. Externalshrouds are available to protect the quadrupole mass filter from condensing species.Laser Cross Beam Source - The Laser Cross Beam source includes two orthogonalunobstructed pathways for laser photon ionisation within the source cage region,providing an alternative to electron impact and electron attachment ionisation.4 Lens Ion Optics with Integral Ioniser - Additionally enables analysis of lowenergy positive and negative ions generated externally to the analyser. For electron,photon and laser stimulated desorption studies.Laser cross beam source.Platinum Ion Source - This source is configured for improved operation in reactivegases. Radially symmetric, UHV compatible.Gold Plated Ion Source - This source is configured to minimise the effects ofsource outgassing. Radially symmetric, UHV compatible. Available as Standard orLow Profile options.FEATURES:standard filament material is oxide coated iridiumother materials available on requestion source options are interchangeableopen and closed sources availablerange of cross beam sources availablestandard and low profile options availableMass Spectrometers for Residual Gas Analysis (RGA) 7

HMTHigh Pressure Residual Gas AnalyserThe Hiden HMT quadrupole mass spectrometer is a uniquedual mode RGA system capable of operating at pressures upto 5x10-3 mbar without the need for differential pumping.Operation at this pressure is achieved using a specially designedion source/quadrupole filter combination and softwarewhich corrects for abundance non-linearity. The unique highpressure specification makes the HMT ideal for processmonitoring applications.The HMT can also operate in RGA mode in the same wayas a traditional quadrupole RGA. Dual Faraday and electronmultiplier detectors provide partial pressure sensitivities downto the 10-13 mbar range.Profile mass scanning in RGA high sensitivity mode.HMTMulti-component trend analysis.FEATURES:HMT mode for high pressure operation to 5x10-3 mbarRGA mode for high sensitivity operation to 10-13 mbar100 amu mass rangestability better than /- 1% over 24 hoursfast access mixed mode scanningreal-time background subtraction8 Mass Spectrometers for Residual Gas Analysis (RGA)Profile mass scanning in high pressure HMT mode.

HAL 201 RCfor Demanding UHV ApplicationsThe Hiden RGA for UHV are designed and configured forresidual gas analysis in demanding UHV applications wherecritical measurements at UHV are required.The HAL analyser includes, as standard, gold plated versionsof all ion source types. The gold plated ion source is providedto minimise source outgassing, suited for applications wheretotal pressure is 5x10-10 mbar.EPICS is the standard instrument control software used inmany light sources around the world and the Hiden HALsystem is fully compatible with EPICS software drivers.beam linesGold plated ion source.Radiation Resistant as standard. Radiation Hard option available.Tokamaks/Torus facilitiesparticle acceleratorssynchrotronsUHV chambersRemote RF and 15m cable. Radiation ‘Hard’ version.Typical profile spectrum for HAL system.FEATURES/OPTIONS:gold plated ion sources to minimise source outgassingelectron impact ioniser with twin oxide coated iridiumfilamentdual Faraday/Channeltron electron multiplier detectorminimum detectable partial pressure of 5x10-14 mbarmaximum operating pressure of 1x10-4 mbarradiation hard with remote RF versionMass Spectrometers for Residual Gas Analysis (RGA) 9

qRGAfor Fusion ResearchAt nuclear fusion research facilities, spectral analysis of thevacuum conditions within Tokamaks is challenging due tocomplex interactions of hydrogen isotopes within the Tokamak.Typically, gas purity is assessed by using RGAs and obtaininga conventional mass spectrum. Validation of fusion fuel purityis complicated due to D2 and 4He occupying the sameatomic mass, 4 amu (mass separation 0.0254 amu), renderingfuel validation purity problematic using conventional massspectrometry RGA techniques.The qRGA provides a solution to this problem as it can alsooperate in a mode allowing complete control of the energy ofthe electrons emitted within the ionisation source, resulting ineach species having a unique fingerprint that can be determinedby qRGA. This mode of operation is known as ThresholdIonisation Mass Spectrometry (TIMS).qRGA, real-time TIMS data taken at JET, UK. D2 and 4He (with thresholdionisation energies at 15.4 eV and 24.5 eV respectively) are easily separatedand quantifiable.Radiation Resistant as standard.Radiation Hard option available.Remote RF and15m cable. Radiation‘Hard’ versionqRGAFEATURES:real-time quantitative gas analysis in a mass range qRGA1-200 amusub PPM detection levelsqRGA operates in both conventional mass analysis andTIMS modes0.5 eV electron energy resolution over the range 0-150 eVlow cost multi-unit solution with radiation and magneticshielding solutions10 Mass Spectrometers for Residual Gas Analysis (RGA)qRGA, real-time TIMS data taken at JET, UK. Spectra show scans at 3 amu,separating 3He from HD. Mass separation of 3He and HD: 0.0058 amu (difficult forany mass spectrometer to resolve in conventional mass mode), is a routinemeasurement for qRGA.

HALO 201 MBEfor Molecular Beam Epitaxy ApplicationsThe Hiden HALO systems are designed for RGA, gas analysisand process monitoring applications including leak detection,trend analysis and vacuum survey.The MBE specific analyser is constructed from compatiblematerials and designed for prolonged use in MBE environmentsand includes, as standard, molybdenum wiring in place ofcopper and a contamination resistant ion source shroud.semiconductoroxidesnitridesHALO 201 MBE analyserHALO 201 MBE with thermal extender optionsolar cellsHALO 201 MBE analyser and RF headFEATURES/OPTIONS:molybdenum wiring in place of copper wiring to improveRGA system lifetime in MBE environmentscontamination resistant ion source shrouddual Faraday/Channelplate electron multiplierminimum detectable partial pressure of 1x10-11 mbar(Faraday) and 2x10-13 mbar (Channelplate)thermal extender option for RGA operation during bakeoutMass Spectrometers for Residual Gas Analysis (RGA) 11

XBSDeposition Rate Monitor for MolecularBeam Analysis & Deposition ControlThe Hiden XBS system is a quadrupole mass spectrometerdesigned for monitoring multiple beam sources simultaneouslyand uniquely offers beam acceptance through a 70 cone.Species-specific analogue signals are used for beam intensityoutput to the users’ source control modules.Beam acceptance apertures are configured individually foreach specific process chamber source position, manufacturedas replaceable plug-in elements to enable retrospectivemodification in event of chamber alteration. Purpose-designedwith high contamination resistance for monitoring evaporatingcomponents and fragments in MBE processes. Manufacturedwith a triple stage mass filter and water-cooled fully-shroudedprobe to protect the probe from the radiant heat sources andto inhibit probe contamination.XBS probemonitor and control in MBE processesmolecular beam studiesmultiple beam source analysisphotoionisation studiesdesorption/outgassing studiesmonitoring and diagnostics of contaminants in theprocess chamberhigh performance RGA with 3F series triple-stagemass filterhigh-sensitivity helium leak check mode for vacuumquality verificationFEATURES:high sensitivity - minimum detectable partial pressure2.5x10-14 mbarmass range: 320 or 510 amucrossbeam ion source, beam acceptance through /- 35 to transverse axisbeam acceptance apertures configured for beam sourcepositionsgrowth rate determination typically 0.01 Å s-1 (speciesdependent)optional water-cooled shroud12 Mass Spectrometers for Residual Gas Analysis (RGA)XBS probe with water-cooled shroud and Z-drive

3F PICfor UHV TPDHiden’s 3F PIC Series quadrupoles are high precision triplefilter analysers with digital detectors for ultimate sensitivity andtime resolution in fast event studies such as UHV TPD. 3F PICSeries analysers are available with UHV compatible mass filtershrouds and low profile ion source for close positioning to thedesorption surface.Application specific software enables the user to controltemperature ramp profiles and collect data in the same program(TPDsoft) or to simply collect MS data and temperature in thesame program (EGAsoft).Both analogue and digital inputs are provided for synchronousacquisition start and sample temperature data display alongsidemass channel data.3D bar data view in TPDsoft.HAL 3F PIC and quartz shroudDisplay MS response vs. temperature.3F PIC with quartz shroudFEATURES:low profile ion sourcerange of shroudsfast data acquisition650 data points per secondwide dynamic rangeMCS mode option for time resolution to 50 ns7 decade continuous log scalegating input for pulsed gas studies down to 100 ns gatingresolutionMass Spectrometers for Residual Gas Analysis (RGA) 13

EPIC & IDPfor UHV Analysis of Neutrals, Radicals & IonsThe Hiden EPIC and IDP have all the features of highperformance RGAs - but with the addition of pole bias mid-axispotential and negative ion capability making them outstandingresearch grade mass spectrometers.The EPIC system is factory-upgradeable for inclusion of anenergy filter, either the Bessel box or Hiden 45 sector fieldtype, ensuring compatibility with the Hiden plasma/SIMS seriesincluding the EQP, EQS, PSM and SIM probes.O- ions formed by dissociative electron attachment e N2O N2 O-.The Hiden IDP is for the direct analysis of low energy ions andneutrals from UHV surface science techniques. Applicationsinclude electron stimulated desorption, photon stimulateddesorption and thermal desorption studies.UHV surface scienceelectron stimulated desorptionphoton stimulated desorptionthermal desorption studiesradical analysisenergy and biofuelstime resolved studiesMass spectrum of negative ions formed by low energy electron attachment.EPIC FEATURES:pole bias mid-axis potentialEPIC 1000 Seriespositive and negative ion detectionElectron Attachment Mass Spectrometry (EAMS)IDP FEATURES:pole bias mid-axis potentialpositive and negative ion detectionElectron Attachment Mass Spectrometry (EAMS)4 lens ion optics14 Mass Spectrometers for Residual Gas Analysis (RGA)Simulation showing the focussing properties ofIDP 4 lens ion optics.

2e-081.8e-083F SERIES 10001.6e-081.4e-08SEM : torrfor High Precision Scientific& Process Applications1.2e-081e-088e-096e-094e-092e-090The HAL 3F RC systems are mass : amudesigned for gas analysis in highprecision scientific and 94The triple filter

HALO - for Residual Gas Analysis . dual mode RGA system capable of operating at pressures up to 5x10-3 mbar without the need for differential pumping. Operation at this pressure is achieved using a specially desig