Introduction And Overview 1

Transcription

3WL/3VL circuit breakers with1Introduction and overviewcommunication capability - PROFIBUS 2General informationSENTRONProtection devices3WL/3VL circuit breakers withcommunication capability PROFIBUSSystem Manual33WL air circuit breakers3VL molded-case circuit4breaker5Zone Selective Interlocking6PROFIBUS data transfer7Data transfer to the PLC8Data libraryAList of abbreviations03/2011A5E01051353-02

Legal informationLegal informationWarning notice systemThis manual contains notices you have to observe in order to ensure your personal safety, as well as to preventdamage to property. The notices referring to your personal safety are highlighted in the manual by a safety alertsymbol, notices referring only to property damage have no safety alert symbol. These notices shown below aregraded according to the degree of danger.DANGERindicates that death or severe personal injury will result if proper precautions are not taken.WARNINGindicates that death or severe personal injury may result if proper precautions are not taken.CAUTIONwith a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.CAUTIONwithout a safety alert symbol, indicates that property damage can result if proper precautions are not taken.NOTICEindicates that an unintended result or situation can occur if the corresponding information is not taken intoaccount.If more than one degree of danger is present, the warning notice representing the highest degree of danger willbe used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating toproperty damage.Qualified PersonnelThe product/system described in this documentation may be operated only by personnel qualified for the specifictask in accordance with the relevant documentation for the specific task, in particular its warning notices andsafety instructions. Qualified personnel are those who, based on their training and experience, are capable ofidentifying risks and avoiding potential hazards when working with these products/systems.Proper use of Siemens productsNote the following:WARNINGSiemens products may only be used for the applications described in the catalog and in the relevant technicaldocumentation. If products and components from other manufacturers are used, these must be recommendedor approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation andmaintenance are required to ensure that the products operate safely and without any problems. The permissibleambient conditions must be adhered to. The information in the relevant documentation must be observed.TrademarksAll names identified by are registered trademarks of the Siemens AG. The remaining trademarks in thispublication may be trademarks whose use by third parties for their own purposes could violate the rights of theowner.Disclaimer of LiabilityWe have reviewed the contents of this publication to ensure consistency with the hardware and softwaredescribed. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, theinformation in this publication is reviewed regularly and any necessary corrections are included in subsequenteditions.Siemens AGIndustry SectorPostfach 48 4890026 NÜRNBERGGERMANYorder number: A5E01051353-02 05/2011Copyright Siemens AG 2008.Technical data subject to change

Table of contents123Introduction and overview . 91.11.1.11.1.21.1.3General information .9Structure of the manual.9Introduction .9SENTRON circuit breakers .91.21.2.11.2.21.2.31.2.4Bus systems.11PROFIBUS DP.11Ethernet.14Modbus RTU .15Communication structure of the SENTRON circuit breakers.16General information . 192.1Other system manuals and literature.192.2Approvals .192.3Standards and approvals .202.4Orientation aids .202.5Up-to-the-minute information at all times.202.6Scope .203WL air circuit breakers . 233.13.1.13.1.23.1.33.1.4Introduction and overview .23The CubicleBUS .26Communications capability of electronic trip units (ETU) .27Function overview of the overcurrent tripping system .29Availability of the data on the CubicleBUS .313.23.2.13.2.23.2.33.2.43.2.53.2.6COM15 module and BSS module.33PROFIBUS DP COM15 module .33Connection of the COM15 module .34PROFIBUS installation guideline .37PROFIBUS write protection (DPWriteEnable) .38Data exchange via the COM15.38Breaker Status Sensor (BSS) .413.33.3.13.3.23.3.3Metering functions.42Metering function PLUS .42Voltage transformer .48Delay of the threshold warning .533WL/3VL circuit breakers with communication capability - PROFIBUSSystem Manual, 03/2011, A5E01051353-023

Table of ctions and parameters . 53Important functions and parameters for communication. 53Load management . 54Extended protection function. 55Threshold values. 56Lower limit of power transmission. 56Direction of incoming supply . 56Events and tripping operations . ernal CubicleBUS modules . 58General information. 58Rotary coding switch . 59Installing the CubicleBUS modules. 59Connection of the power supply. 59Maximum configuration of the CubicleBUS . 60Installation guidelines for the CubicleBUS . 61Connection of external CubicleBUS modules . 61LED indicator. 64Test of the digital input and output modules . 65Digital input module. 67Parameter set changeover. 68Technical data. 69Digital output module with rotary coding switch . 69Technical data. 71Configuration of the digital output module . 72LED indicator. 73Technical data. 76Analog output module . 76Selecting the measured values. 77Test function. 81Technical data. 81ZSI module . 813.63.6.1Measuring accuracy . 823WL breaker measuring accuracy . 823.73.7.13.7.2External current consumption with CubicleBUS . 83Power required by a SENTRON WL with CubicleBUS. 83Selecting the power supply . 843VL molded-case circuit breaker . 874.14.1.14.1.24.1.34.1.44.1.54.1.6Brief description . 87Brief description of SENTRON VL . 87Overview of the accessories . 88Properties of the trip units . 90Electronic overcurrent tripping systems . 90Protection functions. 90Data transfer via PROFIBUS DP . 933WL/3VL circuit breakers with communication capability - PROFIBUS4System Manual, 03/2011, A5E01051353-02

Table of 84.2.95COM20 connection .95Data exchange with the COM20 .95Setting the PROFIBUS address of the COM20 .96COM20 pin assignment .97PROFIBUS installation guidelines COM20.98PROFIBUS DP write protection with COM20 .98Communication connection to the ETU .99Connecting the optional motorized operating mechanism to COM20 .99LED indicators on the COM20 .102Measuring accuracy.103Zone Selective Interlocking. ZSI.105Introduction .105Selectivity .105Time selectivity.106ZSI function .107Operating principle.108Course over time.108Condition ZSI ON and presence of a short-circuit (S) .108Condition ZSI ON and presence of a ground fault (G) .55.2.2.65.2.2.7Examples .110Function example.110Tabular representation.111Short-circuit .111Ground fault .111Example of 3 grading levels without coupling switch.112Cancelation of the ZSI OUT signal .113Coupling switch .114Wiring example .115Circuit breakers without ZSI function .1175.35.3.15.3.25.3.35.3.45.3.55.3.6SENTRON 3WL .118Technical n .119Test function.119LED .1195.45.4.15.4.25.4.35.4.45.4.55.4.6SENTRON 3VL .120COM20/COM 21 .120Technical n .121LED .1213WL/3VL circuit breakers with communication capability - PROFIBUSSystem Manual, 03/2011, A5E01051353-025

Table of contents678PROFIBUS data transfer . 1236.1Integration of the circuit breakers into a communication system . 1236.2Communication . 1236.3Communication with a PROFIBUS DP class 1 master. 1246.4Communication with a PROFIBUS DP class 2 master. 1256.5Integration with the GSD file . 1256.6The three communication paths. 1296.7Setting and changing the PROFIBUS address of the COM15/COM20. 1316.8PROFIBUS profile for SENTRON circuit breakers. 1356.9Cyclic data traffic. 135Data transfer to the PLC . 1437.17.1.17.1.27.1.3Interface to S7-300 and control/diagnosis via PROFIBUS . 143Creating a new project . 143Hardware configuration in HW Config. 146Interface setting for initial configuration of a CPU via MPI. 1527.27.2.17.2.27.2.37.2.47.2.57.2.67.2.7Control program example. 154Control program example. 154Procedure for opening the programming tool . 154Using cyclic data . 155Read data sets . 157Write data sets . 159Reading out diagnostics. 160Sync/Unsync/Freeze/Unfreeze . 1617.37.3.17.3.27.3.3Functional sequences/description of functions . 164Diagnostic messages . 164SYNC and FREEZE . 171Time synchronization . 172Data library . 1758.1Chapter overview . 1758.2Scaling. 1768.3Abbreviations of the data sources. 1768.4Units . 1773WL/3VL circuit breakers with communication capability - PROFIBUS6System Manual, 03/2011, A5E01051353-02

Table of 88.5.98.5.108.5.118.5.128.5.13Function classes .177Function classes of the data points .177Data points for controlling the SENTRON circuit breakers.178Data points for detailed diagnostics of the SENTRON circuit breakers.179Data points for identifying the SENTRON circuit breakers .181Data points for measured values current.182Data points for measured values voltage .183Data points for measured values power .185Data points for other measured values.187Data points for the time stamp (TS) of the measured values .189Parameters of the SENTRON circuit breakers (primary protection function) .191Parameters of the SENTRON circuit breakers (extended protection function) .193Parameters of the SENTRON circuit breakers (parameters for threshold value alarms).195Parameters of the SENTRON circuit breakers (communication, measured valueadjustment, etc.) 8.6.188.6.198.6.208.6.238.6.248.6.25Data sets .199Data set DS 0 S7-V1 system diagnostics .199Data set DS 1 system diagnostics .200Data set DS 51 main overview.201Data set DS 52 main overview 1.203Data set DS 64 data of the harmonic analysis.206Data set DS 68 data of the CubicleBUS module .207Data set DS 69 status of the modules .208Data set DS 72 min. and max. measured values .210Data set DS 73 min. and max. measured values of the voltages.214Data set DS 74 min. and max. measured values of the powers.217Data set DS 76 min. and max. measured values of the frequency and the THD.219Data set DS 77 min. and max. measured values of the temperatures .221Data set DS 91 statistical information.222Data set DS 92 diagnostics data.224Data set DS 93 controlling the circuit breakers.226Data set DS 94 current measured values.227Data set DS 97 detailed identification.232Data set DS 100 identification overview .234Data set DS 128 parameters of the metering function and extended protection function.235Data set DS 129 Parameters of the protection function and settings for load shedding andload pick up .239Data set DS 130 Parameters for the threshold values .

3WL/3VL circuit breakers with communication capability - PROFIBUS SENTRON Protection devices 3WL/3VL circuit breakers with communication capability -