Data sheet5SV3344-3Residual current operated circuit breaker, 4-pole, type F, short-timedelayed, In: 40 A, 30 mA, Un AC: 400 VModelProduct brand nameSENTRONProduct designationRCCBDesign of the productShort-time delayedGeneral technical dataNumber of poles4Size of installation devices / acc. to DIN 438801Protection against electrical shockFinger and back-of-hand safeShort-circuit current / of series fuse / maximumpermissible100 AShort-circuit current rating10 kAcircuit-breaker / Design5SV3Mechanical service life (switching cycles) / typical10 000Switching function / short-term delayedYesOvervoltage categoryIIISupply voltageOperating current / at AC / rated value40 ASupply voltage5SV3344-3Page 1/705/18/2020Subject to change without notice Copyright Siemens

at AC / rated value400 V for testing equipment / minimum195 VSupply voltage frequency rated value50 HzProtection classProtection class IPIP20, if the distribution board is installed, with connectedconductorsSwitching capacitySwitching capacity current / according to IEC 610081 / rated value0.8 kADissipationPower loss [W] / for rated value of the current / at AC/ in hot operating state / per pole1.8 WCurrentTripping residual current / rated value30 mATripping residual / rated value / derated current at 40 Cel40 A at 45 Cel40 A at 50 Cel40 A at 55 Cel40 A at 60 Cel40 A at 65 Cel40 A at 70 Cel40 AType of fault currentFI2t-value / permissible58 000 A²·sSurge current resistance / rated value3 kAProduct detailsProduct feature / silicon-freeYesProduct extension / can be installed / supplementarydevicesYesConnectionsConnectable conductor cross-section / solid minimum0.75 mm² maximum35 mm²Connectable conductor cross-section / stranded minimum0.75 mm² maximum35 mm²Tightening torque / with screw-type terminals minimum2.5 N·m maximum3 N·m5SV3344-3Page 2/705/18/2020Subject to change without notice Copyright Siemens

Position / of power supply cordtop or bottomMechanical DesignHeight90 mmWidth72 mmDepth70 mmInstallation depth70 mmNumber of width units4Mounting typeDIN rail (REG)Mounting positionanyNet weight350 gEnvironmental conditionsAmbient temperature minimum-25 C maximum45 CAmbient temperature / during storage minimum permissible-40 C maximum permissible75 CCertificatesReference code acc. to DIN EN 61346-2F acc. to DIN EN 81346-2FGeneral Product ApprovalDeclaration Vibration and ShockConfirmationFurther informationInformation- and Downloadcenter (Catalogs, Brochures, y Mall (Online ordering n/Catalog/product?mlfb 5SV3344-3Service&Support (Manuals, Certificates, Characteristics, en/ps/5SV3344-3Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, .)http://www.automation.siemens.com/bilddb/cax en.aspx?mlfb m/caxTender s5SV3344-3Page 3/705/18/2020Subject to change without notice Copyright Siemens

716443.92089.845.1571.86.25SV3344-3Page 4/705/18/2020Subject to change without notice Copyright Siemens

135N246N-QIΔ5SV3344-3Page 5/705/18/2020Subject to change without notice Copyright Siemens

ΔI-CB15SV3344-3Page 6/723456NN05/18/2020Subject to change without notice Copyright Siemens

5SV3344-3Page 7/705/18/2020Subject to change without notice Copyright Siemens

Residual current operated circuit breaker, 4-pole, type F, short-time delayed, In: 40 A, 30 mA, Un AC: 400 V Model Product brand name SENTRON Product designation RCCB Design of the product Short-time delayed . Short-circuit current / of series fuse / maximum permissible 100 A Short-circuit current rating 10 kA circuit-breaker / Design 5SV3 .