THE RIGHT CONSUMABLESFOR YOURGC APPLICATIONSClarus 590/690 Gas ChromatographyConsumables and Supplies Reference Guide

INTRODUCTIONAND OVERVIEWFor laboratories looking for a single gaschromatograph that’s flexible enough to handleall types of critical samples, the Clarus platform,590 and 690 GC systems are the ideal choice;a proven high-performance GC platform thatdelivers the stringent sensitivity and characterizationyou need. And they’re designed to meet yourvaried analytical requirements – and the experiencelevels of the people who run them.The new Clarus platform is a remarkable stepforward, delivering a host of features thatenable top performance and increased stability:A wide-range flame ionization detector (FID);Glass Inlet Liners3O-Rings for Glass Inlet Liners5Ferrules5Autosampler Syringes6Injector Septa6Capillary Injector Parts7Packed Injector Parts8Programmed TemperatureProgrammed Temperaturedecreased reactivity; and autosampler technologySplit/Splitless (PSS) Partsheadspace, and solid phase microextraction (SPME)on one system.10On-Column (POC) Partsa new high-performance capillary injector withthat delivers multiple options for liquid injection,2Table of Contents11Flame Ionisation Detector (FID) Parts12Other Detectors, FPD, ECD, NPD, PID, TCD14Vials, Caps and Septa19Crimpers23GC Columns24Gas Purification28Regulators34Flow Meters35Leak Detectors35Ordering Information36Clarus 590/690 GC Consumables and Supplies Reference Guide

Glass Inlet LinersFor the capillary injector on the Clarus 590 or 690 GC system, the liners are required to be 78.5 mm long.Splitless Injector LinersProductDescriptionID (mm)OD (mm)Length (mm)Pkg.Part No.Ultra Deactivated Glass Liner Single Taper for Splitless Injection26.378.55N6502030Ultra Deactivated Single Taper Splitless Liner46.378.55N6502031Ultra Deactivated Single Taper Inlet Liner with Woolfor Splitless Inlets46.378.55N6502035ID (mm)OD (mm)Length (mm)Pkg.Part No.Ultra Deactivated Straight Splitless Liner with Wool26.378.55N6502033Ultra-deactivated Split Precision Liner With Wool46.378.55N6502034Ultra Deactivated Straight Inlet Liner, no Wool16.378.55N6502037Quartz Glass Liner, no Wool, Straight Through withDimple at the Bottom46.378.51N6502038Straight Through Glass Liner, no Wool26.378.51N6502039Glass Liner, Straight Through with Dimple at Bottom, no Wool46.378.51N6502040Capillary Split Deactivated Glass Liners with Deactivated Wool.Quartz Wool is used to Fully Vaporize the Sample46.378.55N65020430.756.378.55N6502044Split Injector LinersProductDescriptionUltra-Deactivated 0.75 mm ID Straight/SPME Inlet LinerSplit/Splitless Injector LinersProductDescriptionID (mm)OD (mm)Length (mm)Pkg.Part No.Ultra Deactivated Single Low Pressure Drop Precision Linerwith Wool46.378.55N6502032Ultra Deactivated Straight Inlet Liner with Woolfor Split/Splitless Inlets46.378.55N6502036Capillary Split/Splitless Deactivated Glass Liners withDeactivated Wool46.378.55N6502041Capillary Split/Splitless Deactivated Glass Liners withDeactivated Wool and Tapered ies3

Glass Inlet LinersProgrammed Temperature Split/Splitless (PSS) Injector LinersProductDescriptionID (mm)OD (mm)Length (mm)Pkg.Part No.Quartz Liner for Splitless Operation– Excellent Liner for Low Volume Analyses1486.21N6121006Quartz Liner for Split Operation (Ships with Instrument)– Approved PerkinElmer Standard Injector Liner2486.21N6121004Siltek Deactivated Glass Liner for Split Operation (with Wool)– Maximum Inertness and Packed with Wool Gives OptimumSample Dispersion. Surface provides inertness over wide samplepH range. Wool can be adsorptive if fibers are broken2486.25N6502001Siltek Deactivated Glass Liner for Split Operation– Max Inertness Gives Optimum Sample Dispersion.Deactivated surface provides minimal bleed and inertnessover a wide sample pH range2486.25N65020024831N10114472731N1011446Zero Dilution Outer Liner – Use in conjunction with N10114462.8Zero Dilution Inner Liner – Use in conjunction with N1011447On-Column Glass Liner2.4486.21N6101539Liner/Hour Glass for POC Injector2.4419.051N6101703Quartz Split Liner with Silanized Glass Wool2486.21N6121008Quartz Split Liner with Silanized Glass Wool2486.25N6121009PSS Deactivated Glass Liners with Deactivated Wool. NarrowBore and Quartz Wool Increase Volatilization and S Splitless Deactivated Glass LinersDirect Injection LinersProduct4DescriptionID (mm)OD (mm)Length (mm)Pkg.Part No.Open Top Uniliner (with Wool) – Packed with fused silica wool,highly recommended for high molecular weight active samples.The fused silica wool traps dirt and sample residue46.292.15N6502016Wide-Bore Column Glass Liner6492.11N6101375Wide-Bore Column On/Off Quartz Liner6492.11N6121003Clarus 590/690 GC Consumables and Supplies Reference Guide

O-Rings for Capillary Injector LinersDescriptionPart No.O-Ring Viton for Glass Liner (Pkg. 10). Maximum Injector Temperature 300 C, recommended for use with Mass Spec.09200714O-Ring, KALREZ for Glass Liner (Pkg. 1). Maximum Injector Temperature 450 C09200725FerrulesSilTite Metal FerrulesFerrules For Use With DetectorsProvide a continuous leak-free connection and are perfectfor connecting your column to a GC/MS.SizeThe SilTite metal ferrule and nut are manufactured from thesame material and therefore expand and contract at the samerate, eliminating the need to re-tighten – even after temperaturecycling. The base of the SilTite ferrule forms a perfect seal withthe MS interface, ensuring a leak-free connection. SilTite metalferrules have a temperature limit well above the temperaturecapacity of the injector, MS interface or GC oven.Description*Hole Size (mm)Part No.SilTite Ferrules Starter Kit*0.4N9306090SilTite Ferrules Starter Kit*0.5N9306091SilTite Ferrules Starter Kit*0.8N9306092SilTite Ferrules (Pkg. 10)0.4N9306093SilTite Ferrules (Pkg. 10)0.5N9306094SilTite Ferrules (Pkg. 10)0.8N9306095SilTite Nuts (Pkg. 5)N/AN9306096For use withColumn ID(mm)Ferrule ID(mm)1 16 in.0.250.41 16 in.0.320.509903700099201051 16 in.0.530.809920141099201071 8 in.0.531.0099033941 16 in.0.32(Two holeferrule)0.5N93060011 8 in.0.32(Two holeferrule)0.509903395Kits include 2 nuts and 10 ferrulesGraphitePart No.Graphite/VespelPart No.09920104N9306000Capillary Column FerrulesGraphiteFerrule of choice for high-temperature applications up to450 C. Graphite seals easily and does not stick to glasscolumns. Suitable for use with FID, TCD and ECD detectors.1/16 in. Short Ferrules For Use WithThe Capillary InjectorGraphite/Vespel 15% graphite/85% polyimide ferrules are recommendedfor use with GC/MS systems. The upper temperature limitis 350 C.**www.perkinelmer.com/chromsuppliesFor use withColumn ID (mm)Ferrule ID (mm)GraphitePart No.Graphite/VespelPart .530.809200787092006870.32(Two hole ferrule)0.5–09200788**Same graphite Part No. for 0.4 and 0.5 mm opening5

Autosampler SyringesGC Inlet SeptaSyringes from PerkinElmer are individually inspected for accuracyand performance.Recommended autosampler syringes are available in 0.5, 5 and50 µL capacities. For routine analyses, the metal plunger in barrelwith PTFE-tipped seal is the standard syringe as shipped witheach Clarus GC instrument. Alternative syringes to use are themetal plunger in barrel or the 0.53 mm on-column injection.DescriptionPart No.50 µL Syringe, Metal Plunger 0.63 mm OD NeedleN61017605 µL Syringe, Metal Plunger PTFE-tipped Seal0.63 mm OD Needle (ships with instrument)N61013905 μL Syringe, Metal Plunger PTFE-tipped Seal0.63 mm OD Needle BLUE Barrel (Pkg. 5 syringes)N6103240Features and Benefits Select from a range of GC septa with varying properties limits Non-stick coating ensures no adhesion of the septa to the GC inlet Pre-conditioned septa, ready to use The CenterGuide design facilitates needle penetration to the samepoint with every injection, for easy and rugged operation Pre-pierced BTO septa provide long autosampler injection life Stay clean surface does not attract dust Compatible with all GC instrumentsDescriptionPkg.Part No.BTO Orange Injection Port Septa50N9302972BTO Orange Injection Port Septa10N93068725 μL Syringe, Metal Plunger PTFE-tipped Seal0.63 mm OD Needle BLUE Barrel (Pkg. 10 syringes)N6103241Green Injection Port Septa50N93062195 µL Syringe, Metal Plunger 0.63 mm OD NeedleN6101251Green Injection Port Septa10N93062185 µL On-column Syringe Metal Plunger 0.47 mm OD NeedleN6101380Blue Injection Port Septa50N93068745 µL, Syringe, PTFE-tipped Metal Plunger 0.47 mm OD NeedleN9308975Blue Injection Port Septa10N93068730.5 µL Low Injection Volume Syringe, Metal Plunger0.63 mm OD NeedleN61012520.5 μL Low Injection Volume Syringe Metal Plunger0.63 mm OD Needle BLUE Barrel (Pkg. 5 syringes)N61032420.5 μL Low Injection Volume Syringe Metal Plunger0.63 mm OD Needle BLUE Barrel (Pkg. 10 syringes)N61032430.5 µL Low Injection Volume Syringe, Metal Plunger0.47 mm OD NeedleN61012530.5 µL Low Injection Volume Syringe, Metal Plunger0.63 mm OD NeedleN61012520.5 μL Low Injection Volume Syringe Metal Plunger0.63 mm OD Needle BLUE Barrel (Pkg. 5 syringes)N61032420.5 μL Low Injection Volume Syringe Metal Plunger0.63 mm OD Needle BLUE Barrel (Pkg. 10 syringes)N61032430.5 µL Low Injection Volume Syringe, Metal Plunger0.47 mm OD NeedleN6101253BTO (Orange)Septa rated to 400 C. The precision molded silicone rubber septaBTO (Bleed Temperature Optimized) are premium ultra-lowbleed injector septa for today’s most demanding applications.The BTO septa are uniquely formulated to extend ultra-low bleedcharacteristics and outstanding mechanical properties. It retainsremarkable softness, even at high temperatures, and has beenoptimized to reduce injection port adhesion, with the addition ofa non-stick coating. The pre-pierced BTO septa also benefit fromthe CenterGuide design. They have a recess on the injection side tohelp guide the syringe needle to the same point for every injection.The BTO septa are recommended for GC/MS applications.GreenSepta rated to 350 C. The advanced green septa were createdto combine significantly longer injection life, low bleed and lowinjection port adhesion. These septa also benefit from also withthe non-stick coating and the CenterGuide design. The result is amid-range general purpose septum made of uniquely formulatedsilicone rubber you can use for all your daily analyses.BlueSepta rated to 275 C. The blue septa are designed for routineapplications. Employing a soft silicone rubber material and stayclean surface, they are easy to penetrate without a recess. As theblue septa used at lower operating temperatures the non-stickcoating is not required to prevent inlet adhesion. They offer alow level of inertness and for routine GC applications providingoptimum performance at lower operating temperatures.6Clarus 590/690 GC Consumables and Supplies Reference Guide

590/690 CapillaryInjector PartsProductDescription213Part No.Septum Cap1PerkinElmer Green Injection Septum (Pkg. 50)N66210282Injector Top NutN65502233Injector HeadN6550220092007144O-Ring, Viton for Glass Liner (Pkg. 1)Maximum Injector Temperature 250 C,Recommended for use with Mass Spec.O-Ring, KALREZ for Glass Liner (Pkg. 1)Maximum Injector Temperature 450 C09200725Ultra-deactivated Straight Inlet Liner With Wool,4.0 mm ID, for Split/Splitless Inlets,N6502036 456895 pack (ships with instrument)See page 3 for a full listing of linersUltra Deactivated Straight Splitless Liner With WoolN6502033Ultra-deactivated Split Precision Liner With Wool,4.0 mm ID, 5 packN6502034Ultra-deactivated Straight Inlet Liner No Wool,1.0 mm ID, 5 packN6502037Straight Through Glass Liner No Wool, 2.0 mm IDN65020396Injector BodyN65502217Brass Nut099031288Front Ferrule – 1/8 in. Brass099031299Back Ferrule – 1/8 in. Brass0990313010Gold Seal NutN655208011Gold SealN65510431/16 in. Short Graphite/Vespel Ferrule (Pkg. 10)09200685512For column ID 0.18 – 0.32 mm/0.4 mmSee page 5 for a full listing of short ferrulesNotshownTrap Installation Kit(same part for both split and splitless injection)N6550140NotshownTrap Replacement CartridgeN6550142Split Vent Trap Connecting Tube – 690, A PositionN6552091Split Vent Trap Connecting Tube – 690, B PositionN6552092Split Vent Trap Connecting Tube – 590, A PositionN6552093Split Vent Trap Connecting Tube – 590, B PositionN6552094Capillary Column lies711101213GC/MS 590/690 CapillaryInjector Consumable KitDescriptionPart No.N6550448GC/MS Capillary Injector Starter Kit for Clarus 690, 590ContentsPkg.Qty.Part No.5.0 µL Autosampler Syringe1N6101390Vial Locator (Dongle)2N6101182Viton O-Rings (300 C)10109200714Kelrez O-Rings(Maximum Injector temperature 450 C)1209200725Ultra Deactivated Split/Splitless Liner, 4 mm,with Wool5109200624Graphite/Vespel Ferrules,for 0.25 mm Columns10109200685PerkinElmer Green Septa (50 pieces)1N6621028Marathon Filament1N6470012Aluminum Oxide Powder (3 oz.)1041901977

Split/Splitless InjectorAdd-On KitsPacked Column InjectorAdd-On KitsAll capillary add on kits need the charcoal trap kit(Part No. N6550140) and the appropriate vent trapconnecting tube.Packed Column Injector Kit with Manual PneumaticsConfigurationPart No.Includes: complete injector assembly with heater and sensor,0 – 100 mL flow controller, and column head pressure gaugefor installation into the AutoSystem.Split Vent Trap Connecting Tube – 690, A PositionN6552091VoltagePart No.Split Vent Trap Connecting Tube – 690, B PositionN6552092120 V*N6120007Split Vent Trap Connecting Tube – 590, A PositionN6552093240 V*N6120023Split Vent Trap Connecting Tube – 590, B PositionN6552094Packed Column Injector Kit with PPCCapillary Injector with PPCKit includes split/splitless injector with programmable pneumaticcontrol for carrier gas, split vent, heater, sensor, and heaterblock. If not, a PPC upgrade kit (Part No. N6120146) is requiredand in addition, modules may also be required. Installation byPerkinElmer Service is required, but not included.VoltageN6550138240 VN6550139Split/Splitless Injector Starter KitIncludes: 2 mm ID quartz liner, 4 mm ID quartz liner, siliconeO-Rings, green septa (50), 0.4 mm, 0.5 mm and 0.8 mmGV ferrules, gold seal, gold seal nut, capillary injector nut andwafer scribes.Split/Splitless Injector Starter Kit for Manual Gas ControlVoltagePart No.120 V*N6120136240 V*N6120137Part No.120 VDescriptionThe kit includes complete injector assembly with programmablepneumatic control, heater, sensor, and heater block. The GC mustbe PPC ready. If not, a PPC upgrade kit (N6120146) is required.Packed Column Injector Kit with Screen Readoutand Manual PneumaticsIncludes: complete injector assembly with heater and sensor,0 – 100 mL flow controller and column head pressure gauge,and transducer for screen readout of column carrier flow.VoltagePart No.120 V* ClarusN6520010230 V* ClarusN6520011Part No.N6550101Packed Column Injector KitThe kit includes complete injector, heater, sensorand heater block. (Does not include pneumatics.)VoltagePart No.120 V*N6120071240 V*N6120072Packed Column Injector Starter KitIncludes glass liner, needle guide, green septa (50),untreated quartz wool, and packing rod.DescriptionPacked Column Injector Starter KitPart No.N6120100*Service installation suggested8Clarus 590/690 GC Consumables and Supplies Reference Guide

Packed InjectorReplacement PartsWide-Bore Adapter Kit0.53 Capillary Column Adapter KitDescriptionPart No.Septum CapN6100153PerkinElmer Green Injection Septum (Pkg. 50)N6621028PerkinElmer BTO Injection Septum (Pkg. 50)N9302972Needle GuideN6101050Glass LinerN6101048Quartz LinerN6121000Packed Injector AssemblyN610004812The Wide-Bore Adapter Kit allows conversion of the packed inletfor 0.53 mm capillary column operation. The kit includes 0 – 20mL flow control element, wide-bore adapter with 1/16 in. fitting,wide-bore glass liner, and column support hanger. Can be usedin both on-column and off-column modes of operation.DescriptionPart No.N61200010.53 Capillary Column Adapter KitGC/MS PSS InjectorConsumable KitDescription3Contents4Part No.N6100447GC/MS PSS Injector Starter KitPkg.Qty.Part No.5.0 µL Autosampler Syringe1N6101390Vial Locator (dongle)2N610118209926067PSS Injector Viton O-Rings (300 C)101PSS Injector Kelrez O-Rings (350 C)101099210042N6121004PSS Split/Splitless Liner, 2 mm, No Wool209920104PerkinElmer Green Septa (50 pieces)1N6621028Marathon Filament1N6470012Aluminum Oxide Powder (3 oz.)104190197Graphite/Vespel Ferrules, for 0.25 mm Columns105www.perkinelmer.com/chromsupplies9

POC Replacement PartsDescriptionPart No.Septum CapN6100153PerkinElmer Green Injection Septum (Pkg. 50)N6621028Needle GuideN6101702Liner/Hour GlassN6101703Body AssemblyN6100256Packed Injector AssemblyN61000481Programmed-TemperatureOn-Column Injector SystemProgrammed-Temperature On-Column (POC) Inlet is designedto be used with fused-silica capillary columns. The sampleis injected onto the column while the inlet is cool. After theinjection, the inlet begins to heat. This delay in heating avoidsthe flash vaporization associated with a normal injection. Thisexplosive vaporization can cause thermal breakdown and/ordiscrimination of certain analytes, which can be avoided byusing the POC.The POC Injector is best used to achieve recovery of compoundsof greater than C60 (e.g., polywaxes). The POC utilizes flowcontrol, producing the best recovery out to C100 or greater.234POC Injector with Manual Flow Controllerand Head Pressure GaugeKit includes all necessary hardware to install injectorinto AutoSystem Series or Clarus Series.VoltagePart No.120 V*N6120076240 V*N6120077POC Injector with Manual Flow Controller and HeadPressure Gauge with Flow Readout on Screen5Kit includes all necessary hardware to install injector intoAutoSystem Series or Clarus Series.VoltagePart No.120 V*N6120082240 V*N6120083POC Injector with PPC Add-On KitKit includes injector with programmable pneumatic control, heater,sensor, and heater block. The Clarus GC must be PPC ready. If not,a PPC upgrade kit (N6120146) is required. Installation by PerkinElmerService is required, but not included.VoltagePart No.120 V*N6120142240 V*N6120143POC Injector Starter KitIncludes: needle guides (5), universal connectors (5), 0.53 mm IDdeactivated fused silica (5 m), 1/16 in. stainless steel nuts (5), 0.8 mmgraphite ferrules (10), green septa (50), and wafer scribes (10).VoltagePOC Injector Starter KitPart No.N6120098* Service installation suggested10Clarus 590/690 GC Consumables and Supplies Reference Guide

Programmed-Temperature PSS Replacement PartsSplit/Splitless InjectorSystemPSS Injector Add-On Kits with Manual PneumaticsPSS with pneumatics and pressure readout on screen.Kit includes all necessary hardware to install injector into GC.Part No.120 V* ClarusN6520014230 V* ClarusN6520015PSS Injector with PPCKit includes injector with programmable pneumatic control,heater, sensor, and heater block. The GC must be PPC ready.If not, a PPC upgrade kit (N6120146) is required.VoltagePart No.120 V*N6120140240 V*N6120141Part No.Septum CapN6100153Injector CoverN6101482PerkinElmer Green Injection Septum (Pkg. 50)N6621028Trap, Charcoal – non PPC versionN6100275PPC version (not shown)The programmed-temperature split/splitless (PSS) inlet allowsaccurate sample delivery to a capillary column. The PSS allowsthe analysis of thermally labile compounds, while eliminatingthe discrimination of high-boiling compounds. One of the majoradvantages of the PSS is that any nonvolatile material will remainin the inlet liner and not on the front of the column.VoltageDescriptionNutN6101705Septum PurgeN6100260O-Ring Viton (Pkg. 10) max temp 300 C,recommended for use withmass spec. Shipped with instrumentN6101747O-Ring KALREZ (Pkg. 1)max temp. 450 C09921004O-Ring Graphite (Pkg. 5)max temp. 450 CN6101751Quartz Liner, 2 mm Split ModeShipped with instrumentN6121004Quartz Liner, 1 mm Splitless ModeN6121006On-column linerN6101539Body AssemblyN6100261Ferrule 1/8 in. x 1/16 in. (Pkg. 10)09920301Nut 1/8 in.09903128Split Vent LineN6100159Purge RestrictorN6101034Nut0990339213PSS Injector Starter KitIncludes: universal connectors (5), 0.53 mm ID deactivatedfused-silica (5 m), 2 mm ID quartz liner, 1 mm ID quartz liner,glass hourglass liner, 1/16 in. stainless steel nuts (5), 0.5 mm IDgraphite ferrules (10), 0.8 mm ID graphite ferrules (10),Viton O-Rings (6), graphite O-Rings (5), untreated quartz wool,wafer scribes (10), and green septa (50).VoltagePSS Injector Starter KitPart No.210411125N61201026Zero Dilution Liners Recommended for Headspace137Used together as set.VoltagePart No.Inner LinerN1011446Outer LinerN10114478* Service installation suggested9www.perkinelmer.com/chromsupplies1411

Wide RangeFID Add-On KitsAuto-Ignite Wide Range FID Add-On Kit (with PPC)Kit includes: detector assembly with heater and sensor,heater block, igniter, programmable pneumatics, amplifier andcontrols for detector combustion gases. GC must be PPC ready.If not, a PPC upgrade kit (N6120146) is required. Installation byPerkinElmer Service is required, but not included.VoltagePart No.Auto-Ignite Wide Range FID Replacement PartsDescriptionPart No.Collector Head Assembly which includesSilicone Rubber O-Ring** (not shown)N655007709902143FID Jet Contact/Spring (included in N6550072)N6001204Jet Assembly (0.28 mm jet, fitted as standard)N6550080Jet Assembly (0.71 mm jet)N6550083120 VN6550167FID BodyN6550082240 VN6550168Nozzle AssemblyN6550072Auto-Ignite Wide Range FID Add-On Kit(Manual Pneumatics), 590 onlyKit includes: detector assembly with heater and sensor, heater block,igniter, hydrogen pressure regulator, amplifier and needle valve.VoltagePart No.120 VN6550165230 VN65501661**52Wide Range FID AmplifierDescriptionWide Range FID AmplifierPart No.3N65592344Detector Series Operation KitTCD/FID Series Operation KitUsed to direct sample effluent from the TCD to the FID.DescriptionTCD/FID Series Operation KitPart No.N6120006PID/FID Series Operation KitUsed to direct sample effluent from the PID to the FID.DescriptionPID/FID Series Operation Kit12Part No.N6120059Clarus 590/690 GC Consumables and Supplies Reference Guide

Wide Range FIDMiscellaneous AccessoriesDescriptionPart No.Auto-Ignite Nozzle Replacement Toolfor removing nozzle from auto-ignite FID bodyN6103188Auto-Ignite FID Catalytic Reactor Accessory*N6120161Capillary Column Adapter for capillary column usewith the FID 1/8 to 1/16 in. detector adapterN6120020Ceramic Column CutterN9301376Cotton ApplicatorsN9301272Detector Cover (Brown Color)N6103225Detector Cover (White Color)N6103151Eraser Brush-Pencil09923078Jet Assembly (0.28 mm jet, fitted as standard)Jet Assembly (0.71 mm jet)N6550080N6550083Jet Replacement Tool1/4 in. nut driver for removing jet from auto-ignite FID bodyN6101297Replacement Stainless Steel Glow Plug for Auto-ignite FIDN61030891/4 in. Packed Column Adapterfor use with 1/4 in. packed columns.1/8 to 1/4 in. adapter fits both injector and detector ends00080100Catalytic Reactor Replacement PartsDescriptionPart No.CatalystN9302698Jet Assembly (specific to methanizer/catalytic reactor)N6100194Quartz Wool (available in the US only)N6102354FID BaseCatalystMiscellaneous AccessoriesHydrogen Regulator Replacement Kit(Manual Pneumatics)Catalytic ReactorAccessoryDescriptionHydrogen Regulator Replacement KitAuto-Ignite Wide Range FID with PPC Add-On KitThe catalytic reactor converts CO and CO2 to methaneconveniently and efficiently. The lower detection limit isextended to well below 0.1 ppm.The catalytic reactor consists of a special catalytic reactor basewhich replaces the FID base. The reactor body contains aquantity of catalyst held in place by a quartz wool plug.Kits include base assembly, reactor tube, and instructions.Part No.N6100289Hydrogen/Air Replacement Needle Valve(Manual Pneumatics)DescriptionHydrogen/Air Replacement Needle ValvePart No.N6101412FID Flow Measurement AdapterDescriptionFID Flow Measurement AdapterPart No.N6101345External Igniter Wide Range FID CatalyticReactor Accessory*DescriptionExternal Igniter FID Catalytic Reactor AccessoryPart No.N6550180* Same part for Auto-Ignite catalytic reactor accessorywww.perkinelmer.com/chromsupplies13

FPD Add-On KitsFPD Replacement Parts for AutoSystem Series GCsDescriptionThe FPD is a highly sensitive and selective detector for bothsulfur and phosphorus compounds. It is especially suitable forenvironmental monitoring of H2S and sulfur gases in generaland for organophosphorus compounds present at trace levels inpesticide analysis. Alkyl tin compounds can also be analyzed bychanging the filter assembly. The sulfur filter is shipped standard.The FPD mounts in either the front or rear detector position.This allows many detector combinations, such as FPD/FPD,FPD/TCD, and FPD/ELCD.The AutoSystem also includes a linearizer function for the sulfurmode and convenient control of the photomultiplier tube fromthe keyboard.Part No.O-Ring09902247Seal Assembly and Window (heat shield)N9300096Liner (window)N6003057FPD Body (upper)N6100243Window HolderN6003066FPD JetN6100245Glass-lined Jet Tailpipe (for all-glass system)N6100264FPD Body (lower)N6100244Photomultiplier Tube09972321The FPD is capillary-column compatible. The detector will acceptcolumns of 0.530 mm ID or less. The standard jet shipped withthe FPD does not have a glass-lined tail pipe. If an all-glasssystem is required and glass packed columns will be used,then a glass-lined tail pipe should be ordered (N6100264).As a reminder, use of packed 1/4 in. columns requires a1/8 to 1/4 in. adapter.Filter Assembly1346FiltersDescriptionPart No.Phosphorus Lens (Yellow)N6000981Sulfur Lens* (Blue)N6000637Tin Lens (Orange)L413547225Air8* Shipped standard7HydrogenFPD Add-On Kit (Manual Pneumatics)Kit includes detector, heater, sensor, heater block, hydrogenneedle valve, air pressure regulator, and sulfur photomultiplierfilter. Requires but does not include FPD amplifier (N6120095).Firmware revision 1.6 or greater required. Firmware must bePerkinElmer Service installed.VoltagePart No.120 V ClarusN6520028230 V ClarusN6520029FPD AmplifierFirmware revision 1.6 or greater required. Firmware must bePerkinElmer Service installed.DescriptionPart No.FPD AmplifierN6120095FPD with PPC Add-On KitKit includes: detector, heater, sensor, heater block, pro grammable pneumatic control for detector combustion gases,and sulfur photomultiplier filter. Requires, but does not include,FPD amplifier (N6120095). GC must be PPC ready. If not, a PPCupgrade kit (N6120146) is required. Installation by PerkinElmerService is required, but not included.VoltagePart No.120 VN6120128230 VN6120129Packed Column Adapter1/8 to 1/4 in. adapter for use with 1/4 in. packed columns.DescriptionAdapter (set of 2)14Part No.00080100Clarus 590/690 GC Consumables and Supplies Reference Guide

ECD Add-On KitsECD Add-On Kit (PPC Pneumatics)The ECD is a versatile, nondestructive detector which respondsstrongly to halogen-containing compounds as well as to certainother electron-capturing substances. The ECD’s high sensitivityand selectivity make it an ideal choice for pesticide-residueanalysis and for detection of halogen-derivatized compounds.The ECD has an independent temperature range of 100-450 C.The detector contains thermal protection that prevents heatingthe Ni63 source to temperatures beyond safe operating limits.Two ECDs can be installed and operated simultaneously on theClarus GCs. Nitrogen or argon/methane is the required detectoroperating gas. The base of the detector terminates in a 1/8 in. fitting.Kit includes: detector, heater, sensor, heater block, and programmablepneumatic control for makeup gas. Requires, but does not include,ECD amplifier (N6120014). The Clarus GCs must be PPC ready. If not,a PPC upgrade kit (N6120146) is required. Installation by PerkinElmerService is required, but not included.VoltageN6120122230 VN6120123Vent Tube AssemblyFlexible tube to safely vent toxic sample effluent.DescriptionVent Tube AssemblyCollector AnodeTo AmplifierPart No.120 VPart No.N6100161Column AdaptersColumn Adapter/ReceiverAdapter converts 1/8 in. fitting to 1/16 in. for use with capillarycolumns. Note: Glass-lined tubing reduces background frompolyimide coating in high-temperature applications.Ni83 Foil (Source)DescriptionCapillary Column Adapter/ReceiverPart No.N6000968PID/ECD Series Operation KitKit for directing effluent from PID to ECD.DescriptionMakeup Gas InPID/ECD Series Operation KitPart No.N6120059Column Connection1/4 in. Packed Column AdapterFor use with 1/4 in. packed columns. 1/8 to 1/4 in. adaptersfit both injector and detector ends. (Pkg. 2).ECD Add-On Kit (Manual Pneumatics)Kit includes all parts necessary to install an ECD on the AutoSystemSeries or Clarus GCs. Includes: detector, heater, sensor, heaterblock, 1/16 in. makeup gas line, makeup gas needle valve, andvent tube assembly. Requires, but does not include, ECD amplifier(N6120014). Installation by PerkinElmer Service is recommended.VoltagePart No.120 V ClarusN6520020230 V ClarusN6520021ECD AmplifierRequired for use with ECD detector with add-on kit.DescriptionPart No.ECD Description1/4 in. Packed Column AdapterPart No.00080100ECD Wipe Test KitU.S. Federal law requires that all ECDs be wipe-tested periodically asdescribed in the instrument operator’s manual. In the U.S., possessionand use of ECD is regulated by N.R.C. and/or state regulatoryagencies. Licensing by regulatory agencies is required. Outside ofthe U.S., check with governing bodies for licensing and regulationscovering possession and use. This kit contains everything necessary todo a complete wipe test. For use on any model GC ECD.DescriptionECD Wipe Test KitPart No.0009166715

NPD Add-On KitsNPD Replacement PartsNPD Add-On Kit (Manual Pneumatics)DescriptionPart No.The NPD can be used for the analysis of organic compou

A wide-range flame ionization detector (FID); a new high-performance capillary injector with decreased reactivity; and autosampler technology that delivers multiple options for liquid injection, headspace, and solid phase microextraction (SPME) on one system. Table of Contents Glass Inlet Liners 3 5 Ferrules 5 Autosampler Syringes 6 Injector .