Liebert EXM 11122017 - OPTOINST

Transcription

Liebert eXMTM80kW - 200kWEfficient, Flexible Power OptimizedFor Medium Size UPS Applications

Enabling Tomorrow’sCRITICAL EDGEINFRASTRUCTUREWe helped some of the largest namesin the industry bring new capacity onlinefaster and at a lower cost when searchand social media increased demand forstorage and computing.We were the first to introduce anintegrated enclosure system todistributed networks.Our portfolio spans power, thermal andinfrastructure management products,software and solutions.2Protecting your critical technologies takesmore than just great software and equipment.It takes a level of experience that only comesfrom years of finding solutions when the industryneeded them most. We were the first to protectmainframes with precision cooling systems.And now as challenges and demandsgrow, we continue to find better waysto help you strengthen your most vitalapplications. Formerly the NetworkPower business of Vertiv, we’ve broughttogether the most trustedand experienced names in criticalinfrastructure.Complemented by a network of nearly250 service centers worldwide. It’s acombination of experience andresources that allow us to better adaptto what’s needed, anticipate what’s nextand continue to find solutions in waysother companies simply can’t.

Liebert eXMTM80kW - 200kWFEATURES Online mode Efficiencyexceeding 96% at partial load ECO mode availability forparallel configurations Unity output PF (kVA kW) Powerful battery chargingcapabilityEfficient, Flexible Power OptimizedFor Medium Size UPS ApplicationsMedium Size UPS as dynamic as your businessSmall and medium sized businesses need UPS solutions that deliver lower firstcosts and ongoing operational savings, high reliability, and enable speed andflexibility in a dynamic IT environment.Vertiv’s commitment is to deliver the most technologically advance product forour customer’s mission critical applications, is once again reiterated by our nextgeneration UPS series Liebert eXMTM Flexible air flow management;from back and top Top or bottom cable entry Integrated transformer option Full frontal access for installationand service LIFETM remote diagnostic andpreventive monitoring service Robust internal architecturemakes it suitable for lightindustrial application3

Liebert eXMTM80kW - 200kWHighly Efficient, most flexible andreliable transformer free UPS forsmall and mid-tier applications.Efficient power protection that canmeet your capital requirements. Ourlatest ECO Mode option delivers over99% efficiency, while the DoubleConversion Mode has been optimizedto exceed 96%.Flexible configurations provides anideal mix of both row-based androom-based benefits, optimized todeliver excellent performance at lowtotal cost of ownership and alloworganizations to meet stringent ServiceLevel Agreements.Reliability is the epicenter ofLiebert eXMTM. Its Internal andexternal architecture is rugged enoughto handle input faults, load faults,temporary overloads, input powerdisturbances and even light %40%50%60%70%80%90%100%On-line modeLiebert eXMTM efficiency curve in double-conversion mode: Liebert eXMTM UPS savesover USD1,000/year for every percentage point gain in efficiency.**USD 0.1/kWhFIE88%TI92%TUVRheinland RTypicalLoadRange94%90%4FICERTI96%CESystem Efficiency96.4%

Liebert eXMTM80kW - 200kWMostly, UPS efficiency is judged at fullload calculations –but your systemrarely runs at full load. Compare doubleconversion efficiencies in the 30-70percent load ranges to get a truepicture of operating costs.This is where Liebert eXMTMdraw out the critical differenceby consistently exceedingunmatched over 96% efficiencylevel.Similarly, under ECO mode LieberteXM constantly delivers over 99%efficiency across the typical load rangeand It is able to do so even in paralleloperation without the need for anexternal accessories thus saving oninitial cost and also, while ensuring highlevel of availability by transferring theload to inverter and vice versa in lessthan 2ms, in case of utility voltageanomaly of failure.TCOeXM savesover65 kUSDBrand Aη @94OpexSince the need for improving energyefficiency has become more ubiquitous, many manufacturers haveintroduced energy efficient UPSsystem to meet the customers' needson energy conservation. But they fail tocommunicate the true picture ofefficiency with respect to load at thetypical operating condition.TCO performance at typical 40-60% load leveleXM savesover65 kUSDCapexEfficient SystemLiebert eXMη @96.401234When two or more UPS are paralleledto reach the required capacity, anintegrated Intelligent Parallelingalgorithm can be established. Intelligent Paralleling evenly distributes theoperating hours across the connectedUPS units by rotating the active onesthus maximizing the total systemefficiency.5678910YearWith its advanced efficiencytechniques, Liebert eXMTM contribute to minimizing the carbon footprintof mission critical applications, helpingdata centers to meet the industry’senvironmental and efficiency compliance standards.5

Liebert eXMTM80kW - 200kWFlexible Configuration and DesignOptionsLiebert eXMTM provides a powerprotection solution of proven qualityfor customer’s IT services. Attributeslike flexible air flow management; fromfront and top cable entry optimized thetotal cost of ownership of the electricalinfrastructure and easily adapts todifferent installation requirement. Froma row of racks in a data center to thecorner of a equipment room (fed fromcables running above the units orbeneath the raised floor).For installations that require fullgalvanic isolation. Some ratingsof Liebert eXMTM can come equippedwith an integrated transformer, offeringa certified proven solution with a zerofootprint impact. Customized to fitspecific needs.Liebert eXMTM is designed to takecare of your dynamic distributionneeds, Liebert eXMTM; 80-120kVA canhouse complete distribution assembly;including input, output, bypass andmaintenance switch.Inbuilt distribution assembly reducesthe capital and commissioningexpenses to be incurred to set upswitch distribution infrastructure.Liebert eXM (160-200 kVA)with switch sidecarFor higher ratings, an optional switchside car can be ordered to felicitate thefull arrangement of switch assembly.This side car arrangement greatlyoptimized the overall space and initialcost by also enabling top cable entry.Liebert eXM detached from the wallLiebert eXM adjacent to the wallLiebert eXM with inbuilt isolation transformer6

Liebert eXMTM80kW - 200kWHigh AvailabilityLiebert eXMTM has been designed tomaximize the availability of securepower, leveraging Vertiv's experienceand expertise in developing high MTBFUPS solutions and Low MTTR througha Design for- Serviceability /Maintainability construction.There are numerous factor contributesto the reliability of Liebert eXMTM. But,one of then is the rugged internaltopology wherein the internal airchannel is designed in such a way thatinternal hot air drives directly towardsheat sink without distressing the PCB’sand other internal sensitive circuitsconsequently the improver service lifeof component prevent prematurefailure and ensue utmost reliabilityLiebert eXMTM provides enhancedfault tolerance at partial load versus atraditional fixed capacity monolithicUPS. It can tolerate internal powermodule failures and still support apartial load without going to bypass.Liebert eXMTM battery charger candeliver 15% of the nominal UPS powerfor battery recharge, so being able toprovide adequate current to chargeeven batteries with a long backup time,thus making it ideal for prolong batterypowered application.7

Liebert eXMTM80kW - 200kWServiceabilityMany Services organizations can perform basic repair activities and maintainequipment at the some level of competency, but VERTIV services can take yourcritical maintenance to the next level-proactive maintenance that can significantly extend the life of you power systems.ONLY VERTIVPROACTIVE**Extend the lifeof Your SystemSystem WideperspectiveEquipmentLevelDecreased r NormalOprational rgencyResponse8Repair OnceFault HasOccurredLIFETM Remote Diagnosticand Preventive MonitoringServiceThe LIFETM remote diagnostic andpreventive monitoring service providesearly warning of UPS conditions andout of tolerances legs. This allowseffective proactive maintenance, fastincident response and remote troubleshooting, giving customers completesecurity and peace of mind.With LIFETM services you will benefitfrom: Uptime Assurance First Time Fix Rate Proactive Analysis Minimized total cost ofownership of your equipment Fast incident Response Reporting

Liebert eXMTM80kW - 200kWCustomer Monitoring InterfacesHuman-Machine InterfaceA comprehensive, easy to use TouchScreen LCD interface provides robustmonitoring and control, as well as auser-friendly graphical display,reducing the likelihood of human error.A Single-line mimic diagram showssystem status at a glance.Hardware ConnectivityLiebert eXMTM allows for the monitoring and control of networked UPSthrough different protocol options: The integration of UPS withBuilding Monitoring andAutomation Systems viaMODBUS RTU, MODBUS/TCPprotocols The integration with synopticpanels via a dry contact boardSoftware ConnectivityLiebert NformTM will monitor theLiebert eXMTM via SNMP protocol.Authenticated alarm management,trend analysis and event notificationdelivers a comprehensive monitoringsolution.Liebert SiteScanTM Web allows usersto virtually monitor and control anypiece of critical support equipment. Itsfeatures include real-time monitoringand control, data analysis, trendreporting, and event management.9

Liebert eXMTM80kW - 200kWIntelligent and intuitive, interface, system monitoring and DCIM solutionscombine to make your infrastructure ready to enhance performance todayand tomorrow.Vertiv’s TrellisTM platform is areal-time infrastructureoptimization platform thatenables the unfired managementof data center IT and facilitiesinfrastructure.The TrellisTM platform softwarecan manage capacity, trackinventory, plan changes,visualize configurations, analyzeand calculate energy usage,and optimize cooling and powerequipment.The TrellisTM platform monitorsthe data center, providing athorough understanding ofsystem dependencies to help ITand facilities organizations keepthe data center running at peakperformance. This unified andcomplete solution, delivers thepower to see the real situationin your data center, make theright decision and take actionwith confidence.10

Liebert eXMTM80kW - 200kWSpecificationsNominal 200kVA/kWInputNominal input voltage(V)380/400/415Input voltage range without battery discharge (V)229 478Nominal input frequency(Hz)50/60Input frequency range(Hz)40-70Upper limit: 10%, 15%, or 20% default: 15%;Lower limit: -10%, -20%, -30% or -40% default: -20%Bypass voltage tolerance(%)Bypass frequency tolerance(%) /- 10% or /- 20%, default: /-10%Input power factor(kW/kVA) 0.99Current THD at full linear load(THDi%) 3%BatteryNumber 12V battery per string(Min-Max)30-44Temperature compensation (mV/ C/cl)-3.0 (selectable from 0 to -5.0 around 25 C or 30 C, or inhibit)Battery Charger max. (A)2024.5304049OutputNominal output voltage (V)380/400/415Nominal output frequency (Hz)50/60Nominal active power (kW)PF 1THDv with 100% linear load (%) 1%Inverter overload capacity110% for 60 min; 125% 10min; 150% for 1 minOnline mode efficiencyUp to 96.4%ECO mode efficiencyUp to 99.1%Dimensions and weightDimensions (W x D x H) mm700 x 1000 x 1500900 x 1000 x 2000900 x 1000 x 20001200 x 1000 x 17001200 x 1000 x 17003504804805806255759596164Weight(Net weight)GeneralNosie at 1 m dB(A)AltitudeVentilationProtection level IEC (60529)General and safetyrequirements for UPSEMC requirements for UPSMethod of specifying the performance and testrequirements of UPS 1500; derate power by 1% per 100m between 1500m and 300mFront to back standard/ Front to top (optional)IP 20 StandardEN62040-1 / IEC62040-1 /AS62040-1EN62040-2 / IEC62040-2 / AS62040-2 (Class C2*)EN62040-3 / IEC62040-3 / AS62040-3 (VFI-SS-111)*Class C3 is standard whereas class C2 is optionalSpecifications are subject to change without any prior notification11

VertivCo.com I E-mail : marketing.india@vertivco.com I Toll free : 1-800-2096070Vertiv Energy Private Limited I Plot C-20, Rd No.19, Wagle Ind Estate, Thane (W), 400604. India 2017 Vertiv Co. All rights reserved.

Liebert eXM TM e iciency curve in double-conversion mode: Liebert eXM UPS saves over USD1,000/year for every percentage point gain in e iciency.**USD 0.1/kWh System E iciency 88% 92% 96% 100% 90% 94% 98% 20% 30% 40% 50% 60% 70% 80% 90% 100% Eco-mode On-line mode 96.4% Typical Load Range 99.1% TUVRheinland I E D I F T R E C C E R T I F I .