EXMTM UPS 80kW - 200kW Efficient, Flexible Power Optimized For Medium .

Transcription

eXMTM UPS80kW - 200kWEfficient, Flexible Power OptimizedFor Medium Size UPS Applications

Medium Size UPS As Dynamic As Your BusinessHighlightsSmall and medium sized businesses need UPS solutions that deliver lowerfirst costs and ongoing operational savings, high reliability, and enablespeed and flexibility in a dynamic IT environmentOnline mode Efficiencyexceeding 96% at partial loadECO mode availability forparallel configurationsVertiv commitment is to deliver the most technologically advanceproduct for our customer’s mission critical applications, is once againTMreiterated by our next generation UPS series Liebert eXMUnity output PF ( kVA kW)Powerful battery chargingcapabilityHighly Efficient, most flexible and reliable transformer free UPS forsmall and mid-tier applications.Flexible air flow management;from back and topTop or bottom cable entryEfficient power protection that can meet your capital requirements. Ourlatest ECO Mode option delivers over 99% efficiency, while the DoubleConversion Mode has been optimized to exceed 96%.Flexible configurations provides an ideal mix of both row-based and roombased benefits, optimized to deliver excellent performance at low total costof ownership and allow organizations to meet stringent Service LevelAgreements.Integrated transformer optionFull frontal access forinstallation and serviceLIFETM remote diagnostic andpreventive monitoring serviceRobust internal architecturemakes it suitable for lightindustrial applicationReliability is the epicenter of Liebert eXMTM. Its Internal and externalarchitecture is rugged enough to handle input faults, load faults, temporaryoverloads, input power disturbances and even light industrial o-modeTM40%50%60%70%80%90%On-line modeLiebert eXM efficiency curve in double-conversion mode: Liebert eXMTM UPS savesover USD1,000/year for every percentage point gain in efficiency.**USD 0.1/kWh100%IF90%T92%TUVRheinland RTypicalLoadRange94%CESystem Efficiency96.4%

Efficient SystemMostly, UPS efficiency is judged atfull load calculations –but yoursystem rarely runs at full load.Compare double conversionefficiencies in the 30-70 percentload ranges to get a true picture ofoperating costs.TMThis is where Liebert eXMdraw out the criticaldifference by consistentlyexceeding unmatched over96% efficiency level.Similarly, under ECO mode LieberteXM constantly delivers over 99%efficiency across the typical loadrange and It is able to do so evenin parallel operation without theneed for an external accessoriesthus saving on initial cost and also,while ensuring high level ofavailability by transferring the loadto inverter and vice versa in lessthan 2ms, in case of utility voltageanomaly of failure.TCO performance at typical 40-60% load levelTCOeXM savesover65 kUSDOpexBrand Aη @94CapexSince the need for improvingenergy efficiency has becomemore ubiquitous, manymanufacturers have introducedenergy efficient UPS system tomeet the customers' needs onenergy conservation. But they failto communicate the true picture ofefficiency with respect to load atthe typical operating conditionLiebert eXMη @96.4012345678910YearWhen two or more UPS are paralleled to reach the required capacity, anintegrated Intelligent Paralleling algorithm can be established. IntelligentParalleling evenly distributes the operating hours across the connected UPSunits by rotating the active ones thus maximizing the total system efficiency.With its advanced efficiency techniques, Liebert eXMTM contribute tominimizing the carbon footprint of mission critical applications, helping datacenters to meet the industry’s environmental and efficiency compliancestandards.

Flexible Configuration and Design OptionsLiebert eXMTM provides a powerprotection solution of proven qualityfor customer’s IT services. Attributeslike flexible air flow management; fromfront and top cable entry optimizedthe total cost of ownership of theelectrical infrastructure and easilyadapts to different installationrequirement. From a row of racks in adata center to the corner of aequipment room (fed from cablesrunning above the units or beneaththe raised floor)For installations that require fullgalvanic isolation. Some ratings ofLiebert eXMTM can come equippedwith an integrated transformer,offering a certified proven solutionwith a zero footprint impact.Liebert eXM (160-200 kVA)with switch sidecarCustomized to fit specific needsLiebert eXMTM is designed to takecare of your dynamic distributionneeds, Liebert eXMTM; 80-120kVA canhouse complete distribution assembly;including input, output, bypass andmaintenance switch.Liebert eXM detached from the wallInbuilt distribution assembly reducesthe capital and commissioningexpenses to be incurred to set upswitch distribution infrastructure.For higher ratings, an optional switchside car can be ordered to felicitatethe full arrangement of switchassembly. This side car arrangementgreatly optimized the overall spaceand initial cost by also enabling topcable entry.Liebert eXM with inbuilt isolation transformerLiebert eXM adjacent to the wall

High AvailabilityLiebert eXMTM has been designed to maximize the availability of securepower, leveraging Vertiv's experience and expertise in developing highMTBF UPS solutions and Low MTTR through a Design for- Serviceability/Maintainability construction.There are numerous factor contributes to the reliability ofLiebert eXMTM. But, one of then is the rugged internal topology whereinthe internal air channel is designed in such a way that internal hot air drivesdirectly towards heat sink without distressing the PCB’s and other internalsensitive circuits consequently the improver service life of componentprevent premature failure and ensue utmost reliabilityLiebert eXMTM provides enhanced fault tolerance at partial load versus atraditional fixed capacity monolithic UPS. It can tolerate internal powermodule failures and still support a partial load without going to bypass.TMLiebert eXM battery charger can deliver 15% of the nominal UPS powerfor battery recharge. so being able to provide adequate current to chargeeven batteries with a long backup time, thus making it ideal for prolongbattery powered application.ServiceabilityMany Services organizations can perform basic repair activities andmaintain equipment at the some level of competency, but VERTIV servicescan take your critical maintenance to the next level-proactive maintenancethat can significantly extend the life of you power systems.ONLY VERTIVPROACTIVE**Extend the Lifeof Your SystemSystem WidePerspectiveDecrease mentLevelRepair NormalOperational StressMANYREACTIVE*EmergencyResponseRepair OnceFault HasOccurredIncreaseEquipmentReliabilityLIFE TM Remote Diagnosticand Preventive MonitoringServiceThe LIFETM remote diagnostic andpreventive monitoring serviceprovides early warning of UPSconditions and out of toleranceslegs. This allows effective proactivemaintenance, fast incidentresponse and remote troubleshooting, giving customerscomplete security and peace ofmind.With LIFETM services you willbenefit from:ŸUptime AssuranceŸFirst Time Fix RateŸProactive AnalysisŸMinimized total cost ofownership of your equipmentŸFast incident ResponseŸReporting

Customer Monitoring InterfacesHuman-Machine InterfaceIntelligent and intuitive,A comprehensive, easy to use LCD interface provides robust monitoringand control, as well as a user-friendly graphical display, reducing thelikelihood of human error.A Single-line mimic diagram shows system status at a glance.interface, systemmonitoring and DCIMsolutions combine tomake your infrastructureready to enhanceperformance today andtomorrow.Hardware ConnectivityLiebert eXMTM allows for the monitoring and control of networked UPSthrough different protocol options:The integration of UPS with Building Monitoring and AutomationSystems via MODBUS RTU, MODBUS/TCP protocolsThe integration with synoptic panels via a dry contact boardSoftware ConnectivityTMTMLiebert Nform will monitor the Liebert eXM via SNMP protocol.Authenticated alarm management, trend analysis and event notificationdelivers a comprehensive monitoring solution.Liebert SiteScanTM Web allows users to virtually monitor and control anypiece of critical support equipment. Its features include real-timemonitoring and control, data analysis, trend reporting, and eventmanagement.TrellisTM Platform Vertiv’sTrellisTM platform is a real-timeinfrastructure optimizationplatform that enables theunfired management of datacenter IT and facilitiesinfrastructure.The TrellisTM platform softwarecan manage capacity, trackinventory, plan changes,visualize configurations, analyzeand calculate energy usage, andoptimize cooling and powerequipment.The TrellisTM platform monitorsthe data center, providing athorough understanding ofsystem dependencies to help ITand facilities organizations keepthe data center running at peakperformance. This unified andcomplete solution, delivers thepower to see the real situation inyour data center, make the rightdecision and take action withconfidence.

SpecificationsNominal 200kVA/kWInputNominal input voltage(V)380/400/415Input voltage range without battery discharge (V)229 478Nominal input frequency(Hz)50/60Input frequency range(Hz)40-70Upper limit: 10%, 15%, or 20% default: 15%;Lower limit: -10%, -20%, -30% or -40% default: -20% /- 10% or /- 20%, default: /-10%Bypass voltage tolerance(%)Bypass frequency tolerance(%)Input power factor(kW/kVA) 0.99Current THD at full linear load(THDi%) 3%BatteryNumber 12V battery per string(Min-Max)30-44Temperature compensation (mV/ C/cl)-3.0 (selectable from 0 to -5.0 around 25 C or 30 C, or inhibit)Battery Charger max. (A)2024.5304049OutputNominal output voltage (V)380/400/415Nominal output frequency (Hz)50/60Nominal active power (kW)PF 1THDv with 100% linear load (%) 1%Inverter overload capacity110% for 60 min; 125% 10min; 150% for 1 minOnline mode efficiencyUp to 96.4%ECO mode efficiencyUp to 99.1%Dimensions and weight600 x 1000 x 2000Dimensions (W x D x H) mmWeight(Net weight)3854304304755205759596164GeneralNosie at 1 m dB(A)AltitudeVentilationProtection level IEC (60529)General and safetyrequirements for UPS 1500; derate power by 1% per 100m between 1500m and 300mFront to back standard/ Front to top (optional)IP 20 StandardEN62040-1 / IEC62040-1 /AS62040-1EMC requirements for UPSEN62040-2 / IEC62040-2 / AS62040-2 (Class C2*)Method of specifying the performance and testrequirements of UPSEN62040-3 / IEC62040-3 / AS62040-3 (VFI-SS-111)*Class C3 is standard whereas class C2 is optionalSpecifications are subject to change without any prior notification

2017 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners.While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions.Specifications are subject to change without notice.ACP-EN-AP-9-1-0-17-3

Liebert eXM efficiency curve in double-conversion mode: LiebertTM eXM UPS saves TM over USD1,000/year for every percentage point gain in efficiency.**USD 0.1/kWh Highlights Online mode Efficiency exceeding 96% at partial load ECO mode availability for parallel configurations Unity output PF ( kVA kW) Powerful battery charging capability