Liebert - Ups-power

Transcription

Liebert eXM UPS10-250 kVA/kWEfficient, Scalable, Intelligent PowerOptimized for Midsize IT

LIEBERT EXM UPSA Midsize UPS As Dynamic As Your Data CenterLiebert eXM 3-Phase AC UPSEfficient and Economical So You Can Control Costsyy 10-250kVA, 208 & 480Volt NativeThe Liebert eXM UPS was purposefully designed to provide efficient power protectionthat can meet your operating and capital requirements.yyUnity Power Factor ensures more power is provided in a smaller footprint, thusincreasing system capacity while minimizing cabling and installation costsyyDelivers high efficiency levels throughout the capacity rangeyy Unity Power Factoryy Up to 99% Efficientyy Optimized Ancillaries provideFlexible Deploymentyy UL 924 Listedyy208 or 480 volt systemsyyVertiv 's transformer-free design saves space, capital, weight and shipping costsyy Next GenerationScalable FunctionalityyySuperior operating efficiencies are realized through both the Eco-Mode option, whichperforms at 99% and the Double Conversion Mode, which delivers 97% (480Vmodels)yy Next Generation TouchscreenControl PanelyyENERGY STAR qualifiedyy Small to midsize IT applicationsLiebert eXM UPS (40kVA/kW, 208V) in Double Conversion Modeyy Edge of the network operations99%yy Midsize/regionalcolocation facilities98%97%EfficiencyThe Liebert eXM UPS is ideal for:96%Liebert eXM UPSDouble ConversionLiebert eXM UPSEcoModeBrand EBrand A95%94%93%92%yy Testing, medical andtelecom systemsyy Emergency lightingUL 924 EmergencyLighting UPS91%90%30%40%50%60%70%80%90%100%LoadIntuitive, Intelligent OperationTouch-Screen Control Panel OffersIntelligent ControlyyVerify the health of the entire batterysystemyyIntuitive, easy to use to reducechances of human erroryyIntegrated into the battery cabinetyyImproves productivity by providinginformation you needyyPower performance parametersvisualizedyyService and maintenance support atyour fingertipsyyCompatible with The Trellis Platform2Optional Integrated Albér BatteryMonitoring SystemsyyAdvance warning of pending UPSbattery failuresyyReal-time system and componentlevel visibilityAlbér BDSUi Battery Monitor

CRITICAL SERVICESAND SUPPORTFlexible Configurations and Deployment OptionsScale With EaseLIFE Services forThe flexible, scalable, redundant design of the Liebert eXM UPS is available in manysystem configurations to ensure optimal power protection.yy24x7 continuous remote monitoringyyExpert analysis and diagnosisyyQuick, safe and accurate responseyyJust one of the professional service &support options available to improveuptime, cost control and resourceallocationLiebert Servicesyy24x7 critical maintenance responseUp to 100kW 208VUp to 200kW 208VUp to 250kW 480V(200kVA shown)On-line, double conversion design delivers reliable power and highest levels of uptime.yyProactive service, extendssystem lifeyyImproved MTBF and MTTRyyLocal factory trained engineers readyto respondyyMulti-module configurations enhance availabilityyyInternally redundant design reduces switches to bypassyyParts, expertise, satisfactionyyStandard 65kA short circuit withstand rating (certain conditions may apply)MonitoringyyEasy access to key componentsyyHigh Mean Time Between Failure (MTBF) performanceAnalysis &DiagnosticsResponseCapacity, Redundancy, FlexibilityThe Liebert eXM UPS providesfuture-proof scalability along with matchingancillary cabinets to address your powersystem demands.GROWFROMFlexible Scalability PathsMeet Your Capacity/Redundancy PlansInternal Batteriesyy Maintenance bypass cabinetyy Rapid deploymentyy Bypass and distribution cabinetyy Reduce the pains ofpredicting capacityyy Battery cabinet (many run time options)yy Transformer cabinetyy Paralleling cabinet (parallel for highercapacity or redundancy).yy Configure forN 1 redundancy10kW 208VTO40kW 208VInternal Batteries20kW 208V100kW 208V20kW 208V200kW 208V50kW 480V200kW 480V50kW 480V250kW 480V3

LIEBERT EXM UPSSpecificationsPower Rating – kW/kVAInternal Battery SupportedInput AC Specifications208V NATIVE208V NATIVE480V NATIVE10, 15, 20, 30, 4060, 80, 100, 120, 140, 160, 180, 20050, 100, 150, 200, 250YNNPhase/Power Factor/Freq RangeInput VoltageGeneral SpecificationsUPS TechnologyBattery SpecificationsBattery Test Type/Battery TechnologyOutput AC SpecificationsVoltage3 / 0.99 lagging minimum at full load / 40-70 Hz208, 220, 4801, 6001 VAC, 60Hz, 3-phase, 4-wire plus groundOnline / Valve-regulated lead acid battery208/120, 220/127VAC, 60Hz 3-phase, 3- or 4-wire plus groundFrequency HzCommunications3 Liebert IntelliSlotsCard CompatibilityIS-UNITY-DP, IS-UNITY-LIFE, IS-485EXI, IS-RELAYProtocols AvailableMODBUS-IP, MODBUS-485, BACNET-IP, BACNET-MSTP, SNMP, HTTP, LIFETM Services, Relay ContactsLiebert SN SeriesPhysical Data UPSUPS RatingTemperature, Humidity, Temperature/Humidity Combination, Contact ClosureUnit Weightlb (kg)Dimensions, W X D X H in (mm)10kVA, 15kVA, 20kVA604 (274)23.6 x 39.5 x 78.7 (600 x 1000 x 2000)30kVA, 40kVA678 (307.5)23.6 x 39.5 x 78.7 (600 x 1000 x 2000)50kVAN/AN/A60kVA807 (366)23.6 x 39.5 x 78.7 (600 x 1000 x 2000)80kVA881 (399.6)23.6 x 39.5 x 78.7 (600 x 1000 x 2000)100kVA955 (433.1)23.6 x 39.5 x 78.7 (600 x 1000 x 2000)120kVA1221 (553.8)34.6 x 39.5 x 78.7 (880 x 1000 x 2000)140kVA1295 (587.4)34.6 x 39.5 x 78.7 (880 x 1000 x 2000)150kVADimensions, W X D X H in (mm)748 (339)23.6 x 39.5 x 78.7(600 x 1000 x 2000)842 (382)23.6 x 39.5 x 78.7(600 x 1000 x 2000)936 (425)23.6 x 39.5 x 78.7(600 x 1000 x 2000)1368 (620.5)34.6 x 39.5 x 78.7 (880 x 1000 x 2000)180kVA1442 (654)34.6 x 39.5 x 78.7 (880 x 1000 x 2000)200kVA1516 (687.6)34.6 x 39.5 x 78.7 (880 x 1000 x 2000)1030 (467)23.6 x 39.5 x 78.7(600 x 1000 x 2000)250kVAN/AN/A1244 (564)33.0 x 39.5 x 78.7(880 x 1000 x 2000)Weight lb (kg)600mm Bypass Distribution Cabinet550 (250)Dimensions, W X D X H in (mm)Weight lb (kg)23.6 x 39.5 x 78.7 (600 x 1000 x 2000)Dimensions, W X D X H in (mm)N/AN/A300mm Maintenance Bypass Cabinet288 (131)11.8 x 39.5 x 78.7 (300 x 1000 x 2000)288 (131)11.8 x 39.5 x 78.7(300 x 1000 x 2000)200mm Maintenance Bypass Cabinet198 (90)7.9 x 39.5 x 78.7 (200 x 1000 x 2000)198 (90)7.9 x 39.5 x 78.7(200 x 1000 x 2000)1200mm Battery Cabinet2N/AN/A4907 (2226) withHX540 batteries47.2 x 39.5 x 78.7(1200 x 1000 x 2000)880mm Battery Cabinet23649 (1656) withHX540 batteries34.7 x 39.5 x 78.7 (880 x 1000 x 2000)2962 (1344) withHX300 batteries34.7 x 39.5 x 78.7(880 x 1000 x 2000)600mm Battery Cabinet22454 (1114) withHX330 batteries23.6 x 39.5 x 78.7 (600 x 1000 x 2000)N/AN/A320mm Battery Cabinet31432 (650) withHX205 batteries12.6 x 39.5 x 78.7 (320 x 1000 x rmance4Unit Weight lb (kg)160kVAPhysical Data AncillariesWarranty Standard480VAC, 60Hz 3-phase, 3-wire plus ground60 HzaOptionsEnvironmental Sensors480, 600 VAC, 60Hz, 3-phase, 3-wire plus groundOn-Line Double ConversionOperating Temperature, F ( C): UPS: 32 to 104 F (0-40 C); Battery: 68 to 86 F (20-30 C). Relative Humidity: 0% to 95%,non-condensing. Operating Altitude: Up to 3,300 ft. (1,000m) without derating. Acoustical Noise, db, at 39 in.: Less than 59 dBA typical,3.3 ft. (1m) from the unitListed to UL 1778 and CSA certified. Meets current requirements for safe high performance UPS operation.ENERGY STAR qualified1 year

VertivCo.com Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA 2016 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has beentaken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.SL-26003 (06/16)

LIEBERT EXM UPS Specifications 208V NATIVE 208V NATIVE 480V NATIVE Power Rating - kW/kVA 10, 15, 20, 30, 40 60, 80, 100, 120, 140, 160, 180, 200 50, 100, 150, 200, 250 Internal Battery Supported Y N N Input AC Specifications Phase/Power Factor/ Freq Range