EXMTM UPS - Vertiv

Transcription

EXMTM UPS80kW - 200kWEfficient and Flexible Power-OptimizedFor Medium-Size UPS Applications

Liebert EXM T M UPSMedium-Size UPS as dynamic as your BusinessHighlightsSmall- and medium- sized businesses need UPS solutions that deliver lowerfirst costs and ongoing operational savings, high reliability, and enablespeed and flexibility in a dynamic IT environment.Online mode efficiencyexceeding 96% at partial loadECO-mode availability forparallel configurationsVertiv’s commitment to deliver the most technologically-advanced productfor your mission-critical applications is reiterated by our next generationTMUPS series, Liebert EXM .Highly efficient, most flexible, & reliable transformer-free UPS for smalland mid-tier applicationsEfficient power protection can help you meet your capital requirements.Our latest ECO-mode feature delivers over 99% efficiency, while the DoubleConversion mode has been optimized to exceed 96% efficiency.Flexible configurations provide an ideal mix of both row-based and roombased benefits, optimized to deliver excellent performance at a significantlylow total cost of ownership, and allow organizations to meet stringentService Level Agreements.Unity output PF ( kVA kW)Powerful battery chargingcapabilityFlexible air flow management;From front to back orfront to topTop or bottom cable entryIntegrated transformer optionFull front access forinstallation & serviceTMLIFE remote diagnostic &preventive monitoring serviceRobust internal architecturemakes it suitable for lightindustrial applicationsTMReliability is the epicenter of Liebert EXM . Its internal and externalarchitecture is rugged enough to handle input faults, load faults, temporaryoverloads, input power disturbances, and even light industrial environment.With improved touch -modeTM40%50%60%70%80%90%Online modeLiebert EXM efficiency curve in double-conversion mode: Liebert EXMTM UPS savesover USD 1,000/year for every percentage point gain in efficiency.**USD 0.1/kWh100%FIE90%TI92%TUVRheinland RTypicalLoadRange94%CESystem Efficiency96.4%Liebert EXMTMs Efficiencycredentials and performance iscertified by TUV-Rheinlandin accordance withIEC/EN 62040-1, IEC/EN 62040-3

Efficient SystemUsually, UPS efficiency is judged atfull load calculations –but yoursystem rarely runs at full load.Compare double conversionefficiencies in the 30-70% loadrange to get a true picture of theoperating costs.This is where Liebert EXMTMdraws out the criticaldifference by consistentlyexceeding unmatched 96%efficiency levels.Similarly, under the ECO-modeTMLiebert EXM constantly deliversover 99% efficiency across thetypical load range & it is able to doso even in a parallel operation,without the need for externalaccessories, thus saving on initialcosts, while ensuring a high levelof availability by transferring theload to inverter and vice-versa inless than 2ms, in case of a utilityvoltage anomaly of failure.TCO performance at typical 40-60% load levelTCOEXM savesover65 kUSDOpexBrand Aη @94CapexSince the need for improvingenergy efficiency has becomeubiquitous, many manufacturershave introduced energy efficientUPS systems to meet customerrequirements on energyconservation. However, they fail toconvey the true picture ofefficiency with respect to load attypical operating conditions.Liebert eXMη @96.4012345678910YearWhen two or more UPS are paralleled to reach the required capacity, anintegrated Intelligent Paralleling algorithm comes into the picture. IntelligentParalleling evenly distributes the operating hours across the connected UPSunits by rotating the active ones, thus maximizing the total systemefficiency.With its advanced efficiency techniques, Liebert EXMTM contributes tominimizing the carbon footprint of applications, thereby helping data centersto meet the industry’s environmental and efficiency compliance standards.

Liebert EXM T M UPSFlexible Configuration & Design OptionsLiebert EXMTM provides a powerprotection solution of proven qualityfor your IT services. With versatilefeatures such as flexible air flowmanagement with the facility of frontand top cable entry, it significantlyreduces the total cost of ownership ofthe electrical infrastructure and easilyadapts to different installationrequirements- from a row of racks ina data center to the corner of anequipment room (fed from cablesrunning above the units or beneaththe raised floor).For installations that require fullgalvanic isolationLiebert EXM (160-200 kVA) with switch sidecarTMSome ratings of Liebert EXM can beequipped with an integratedtransformer, offering a certified provensolution with a zero footprint impact.Customized to fit specific needsLiebert EXM is designed to takecare of your dynamic distributionTMneeds. Liebert EXM 80-120kVA canhouse a complete distributionassembly including an input, output,bypass, and maintenance switch.TMBuilt-in distribution assembly reducesthe capital and commissioningexpenses that occur while setting up aswitch distribution infrastructure.For higher ratings, an optional switchside car can be ordered to facilitatethe full arrangement of the switchassembly. This side car arrangementgreatly optimizes the overall space &saves initial costs by also enabling topcable entry.Liebert EXM detached from the wallLiebert EXM adjacent to the wall

High AvailabilityTMLiebert EXM has been designed to maximize the availability of securepower, leveraging Vertiv's experience and expertise in developing highMTBF UPS solutions and Low MTTR through a design for serviceability/maintainability construction.There are numerous factors that contributes to the reliability ofLiebert EXMTM. Especially, one of them is the rugged internal topologywherein the internal air channel is designed in such a way that internal hotair drives directly towards the heat sink, without distressing the PCBs andother internal sensitive circuits, consequently improving the service life ofthe component significantly, thereby preventing failure and ensuring utmostreliability.TMLiebert EXM provides enhanced fault tolerance at partial loads versus atraditional fixed capacity monolithic UPS. It can tolerate internal powermodule failures and still support a partial load without going to bypassmode.TMThe battery charger of Liebert EXM can deliver 15% of the nominal UPSpower for battery recharge. Therefore, it is able to provide adequate currentto charge even batteries with a long backup time, thus making it ideal forprolonged battery-powered applications.ServiceabilityMany service organizations can perform basic repair activities and maintainequipment at some level of competency, but Vertiv services can take yourcritical maintenance to the next level-proactive maintenance that cansignificantly extend the life of your power systems.TMLIFE Remote Diagnostic &Preventive MonitoringServiceTMThe LIFE remote diagnostic &preventive monitoring serviceprovides early warning of UPSconditions and out of tolerancelogs. This allows effective proactivemaintenance, fast incidentresponse and remote troubleshooting, subsequently giving youcomplete security and peace ofmind.ONLY VERTIVPROACTIVE**Extend the Lifeof Your SystemSystem ntLevelRepair NormalOperational StressMANYREACTIVE*EmergencyResponseTMDecrease CapitalInvestmentRepair OnceFault HasOccurredIncreaseEquipmentReliabilityWith LIFE services you will benefitfrom:ŸUptime assuranceŸFirst time fix rateŸProactive analysisŸMinimized total cost ofequipment ownershipŸFast incident responseŸEffective reporting

Liebert EXM T M UPSIntuitive, Intelligent Operations at Every LevelSOFTWARETouch Screen Control Panel offers Intelligent ControlSoftware to Match Your NeedsŸŸŸŸŸIntuitive, easy to use and reduces chances of human errorImproves productivity by providing relevant and crucial informationPower performance parameters visualizedService and maintenance support at your fingertipsTMCompatible with the Trellis PlatformThe Trellis TM PlatformNewOptional Integrated Alber Battery Monitoring SystemsAdvance warning of pending UPS battery failuresReal-time system and component level visibilityŸ Verify the health of the entire battery systemŸ Integrated into the battery cabinetŸŸAlber BDSUi Battery MonitorCommunications & Environmental Monitoring:Leverage the capabilities of Unity Communications card and sensors toeasily daisy chain together data inputs to monitor the MoreLiebert SiteScan Liebert Nform TM

Technical SpecificationsNominal 200kVA/kWInputNominal input voltage (V)380/400/415Input voltage range without battery discharge (V)*229 478Nominal input frequency (Hz)50/60Input frequency range (Hz)40-70Upper limit: 10%, 15%, or 20% default: 15%;Lower limit: -10%, -20%, -30% or -40% default: -20% /- 10% or /- 20%, default: /-10%Bypass voltage tolerance (%)Bypass frequency tolerance (%)Input power factor (kW/kVA) 0.99Current THD at full linear load (THDi%)* 3%BatteryNumber 12V battery per string (Min-Max)30-44Temperature compensation (mV/ C/cl)Battery charger max. (A)-3.0 (selectable from 0 to -5.0 around 25 C or 30 C, or inhibit)2024.5304049OutputNominal output voltage (V)380/400/415Nominal output frequency (Hz)50/60Nominal active power (kW)PF 1THDv with 100% linear load (%) 1%Inverter overload capacity110% for 60 min; 125% 10min; 150% for 1 minOnline mode efficiencyUp to 96.4%ECO-Mode efficiencyUp to 99.1%Dimensions and weight600 x 1000 x 2000Dimensions (W x D x H) mmWeight(Net weight)3854304304755205759596164GeneralNoise at 1 m dB(A)AltitudeVentilationProtection level IEC (60529)General and safetyrequirements for UPS 1500; derate power by 1% per 100m between 1500m and 300mFront to back standard/ Front to top (optional)IP 20 StandardEN62040-1 / IEC62040-1 /AS62040-1EMC requirements for UPSEN62040-2 / IEC62040-2 / AS62040-2 (Class C2*)Method of specifying the performance and testrequirements of UPSEN62040-3 / IEC62040-3 / AS62040-3 (VFI-SS-111)* Conditions applyNote: Class C3 is standard whereas class C2 is optional;Specifications are subject to change without any prior notification.

2017 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners.While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions.Specifications are subject to change without notice.ACP-EN-AP-9-1-0-17-3

Liebert EXMTM provides enhanced fault tolerance at partial loads versus a traditional fixed capacity monolithic UPS. It can tolerate internal power module failures and still support a partial load without going to bypass mode. The battery charger of Liebert EXMTM can deliver 15% of the nominal UPS power for battery recharge.