Vrf Heat Recovery Systems And Heat Pump Systems

Transcription

WITH LGRED VRF HEAT RECOVERY SYSTEMSAND HEAT PUMP SYSTEMSLG Air Conditioning Technologies

ABOUT LG VRFWHAT IS VRF?A Variable Refrigerant Flow (VRF) system uses a closed refrigerant circuit, connecting oneoutdoor unit to many indoor units, providing individual zone temperature control. VRF is anefficient way to condition any space, providing improved humidity control, individual setpoints per indoor unit and a very quiet experience for the occupants.In the heat recovery configuration, VRF also allows for heating and cooling simultaneouslyin different zones by using heat energy from one space to condition another, reducing theamount of 'created' energy further enhancing energy savings and increasingoccupant comfort.ADVANTAGESWHY MULTI V S?The LG Multi V S and Multi V S with LGRED is a compact yet powerful VRF solution for residential and lightcommercial applications. LG Multi V S utilizes single-phase power so it can be used residentially as well asin a wide range of commercial applications, offering overall increased flexibility and efficiency for propertyowners. To meet the needs of multiple applications and loads, Multi V S systems are capable of heat pumpor heat recovery and several models include LGRED heat technology. Multi V S systems require little to noductwork, resulting in smaller space requirements which allow for higher interior ceilings, less structuralimpact and more usable square footage.MAXIMIZEDEFFICIENCYOPTIMIZEDCOMFORTSmart Load ControlIndividual Zone ControlAutomatically adjusts operationrequirements by sensing both indoorand outdoor conditionsAllows the user to control the space tothe precise temperature desiredInverter CompressorAllows the system to closely matchcompressor speed with outputdemand, which translates to ahigher energy efficiencyAbout LG Electronics USA IncLG Electronics USA, Inc., based in Englewood Cliffs, New Jersey, is the North American subsidiary ofLG Electronics, Inc., a 54 billion global force and technology leader in consumer electronics, homeappliances and mobile communications. LG Electronics, a proud ENERGY STAR Partner of the Yearfor the past 5 consecutive years, sells a range of stylish and innovative home entertainmentproducts, mobile phones, home appliances, commercial displays, air conditioning systems and solarenergy solutions in the United States, all under LG’s “Life’s Good” marketing theme. For more newsand information on LG Electronics, please visit www.LG.com.About LG Electronics Air Conditioning TechnologiesThe LG Electronics USA Air Conditioning Technologies business is based in Alpharetta, Georgia. LG isa leading player in the global air conditioning market, manufacturing both commercial and residentialair conditioners and providing total sustainability and building management solutions. Fromconsumer and individual units to industrial and specialized air conditioning systems, LG providesa wide range of products for heating, ventilating and air conditioning. Visit www.lghvac.com formore information.Quiet OperationLG Multi V Indoor units operatequietly in the interior space, withrated sound levels as low as 23 dB(A)VERSATILESOLUTIONSSUPERIORPERFORMANCECompact and LightweightPowerful HeatingConnect up to 12 indoor units to oneoutdoor unit to heat and cool more zoneswhile using less outdoor space(less than 3.4 ft2)Continuous heating down to -13 FLGRED models feature100% heating capacity at 5 FDesign FlexibilityHeat RecoveryChoose from a wide variety of indoorunit styles, both ducted and non-ducted,including the award-winningLG Art Cool GalleryHeat and cool different areassimultaneously by taking heat removedfrom one space in cooling mode and3

APPLICATIONSMULTI V S WITH LGRED RESIDENTIALHEAT PUMP AND HEAT RECOVERYContinuous heating down to -13 F.100% heating capacity at 5 F.ModelCapacityLIGHT COMMERCIALPowerOperating RangeDimensionsWeightSpecificationsHeat Pump / Heat RecoveryTonsNominal Cooling Capacity1Nominal Heating Capacity1Rated Cooling Capacity2Rated Heating Capacity2VoltagePower/Communication Wiring5Cooling Operation Range6Heating Operation RangeDimensions (WxHxD)NetShippingSound Pressure4FanCompressorCooling/HeatingAir Flow RateTypeOil TypeRefrigerantQuantityCoatingRows/Fins per inchLiquid Line (OD)HP/Vapor Line (OD)LP/Vapor Line (OD)TypeChargeNumber of Indoor Units3ControlMinimum / MaximumHeat ExchangePipingUnitARUM036GSS5Heat Pump and Heat Recovery3ARUM048GSS5Heat Pump and Heat 00036,00048,00042,00054,000V / Hz / ØNo. x AWG F FinlbslbsdB(A)208-230/60/1208-230/60/1CFM2 x 182 x 1823 - 12223 - 122-13 - 61-13 - 6137-13/32 x 54-11/32 x 1337-3/32 x 54-11/32 x 1326326329429450/5352/54Axial Flow Fan x2Axial Flow Fan x242384238Hermetically Sealed ScrollHermetically Sealed ScrollFVC68DFVC68D11Aluminum Fin & Black Fin / Copper TubeAluminum Fin & Black Fin / Copper Tube3 / 143 / 14ininin3/83/8lbs5/85/83/43/4R410AR410A7.7 lbs.7.7 lbs.EEVEEV2/62/81. Nominal capacity applied with non-ducted indoor units, and is rated 0 ft. above sea level with 25 ft. of refrigerant line per indoor unit and a 0 ft. level difference between outdoor and indoor units. Allcapacities are net with a Combination Ratio between 95–105%.Nominal cooling capacity rating obtained with air entering the indoor unit at 80 F dry bulb (DB) and 67 F wet bulb (WB) and outdoor ambient conditions of 95 F dry bulb (DB) and 75 F wet bulb (WB).Nominal heating capacity rating obtained with air entering the indoor unit at 70 F dry bulb (DB) and 59 F wet bulb (WB) and outdoor ambient conditions of 47 F dry bulb (DB) and 43 F wet bulb (WB).2. Rated capacity is certified under AHRI Standard 1230. See www.ahrinet.org for information.3. The System Combination Ratio must be between 50–130%.4. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.5. Power wiring is field provided, solid or stranded, and must comply with all local and national codes. Refer to the engineering manual for detailed electrical data.6. Cooling range with the Low Ambient Baffle Kit (sold separately) is down to -9.9 F.7. Multi V S units with LGRED ship from the factory configured for heat recovery operation. For heat pump operation, the DIP switch settings must be set accordingly. See the product installation manual for details.Due to our commitment to continued innovation, some specifications may be changed without notification.4LG Air Conditioning Technologies5

MULTI V SH E A TModelCapacityPowerOperating RangeDimensionsWeightMULTI V SP U M PSpecificationsHeat Pump / Heat RecoveryTonsNominal Cooling Capacity1Nominal Heating Capacity1Rated Cooling Capacity2Rated Heating Capacity2VoltagePower/Communication Wiring5Cooling Operation Range6Heating Operation RangeDimensions (WxHxD)NetShippingSound Pressure4FanCompressorTypeAir Flow RateTypeOil TypeRefrigerantQuantityCoatingRows/Fins per inchLiquid Line (OD)LP/Vapor Line (OD)TypeChargeNumber of Indoor Units3ControlMinimum / MaximumHeat ExchangerPipingH E AT R ECO V E R YUnitARUN024GSS4Heat Pump2ARUN038GSS4Heat Pump3ARUN048GSS4Heat Pump4ARUN060GSS4Heat 00042,00054,00064,000V / Hz / ØNo. x AWG F 208-230/60/1CFMininlbs2 x 182 x 182 x 182 x 1823 to 12223 to 12223 to 12223 to 122-4 to 61-4 to 61-4 to 6137-13/32 x 32-27/32 x 13 37-13/32 x 54-11/32 x 13 37-13/32 x 54-11/32 x 13-13 to 6137-13/32 x 54-11/32 x 1315920720726017621821829150505157Axial Flow FanAxial Flow FanAxial Flow FanAxial Flow Fan2,1193,8853,8853,885DC InverterPVE/FVC68DDC InverterPVE/FVC68DDC InverterPVE/FVC68DScroll InverterPVE/FVC68D1111Gold Fin / HydrophilicGold Fin / HydrophilicGold Fin / HydrophilicGold Fin / Hydrophilic2 / 142 / 142 / 143 / R410A7.7EEVEEVEEVEEV2/42/62/82 / 121. Nominal capacity applied with non-ducted indoor units, and is rated 0 ft. above sea level with 25 ft. of refrigerant line per indoor unit and a 0 ft. level difference between outdoor and indoor units. Allcapacities are net with a Combination Ratio between 95–105%.Nominal cooling capacity rating obtained with air entering the indoor unit at 80 F dry bulb (DB) and 67 F wet bulb (WB) and outdoor ambient conditions of 95 F dry bulb (DB) and 75 F wet bulb (WB).Nominal heating capacity rating obtained with air entering the indoor unit at 70 F dry bulb (DB) and 59 F wet bulb (WB) and outdoor ambient conditions of 47 F dry bulb (DB) and 43 F wet bulb (WB).2. Rated capacity is certified under AHRI Standard 1230. See www.ahrinet.org for information.3. The System Combination Ratio must be between 50–130%.4. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.5. Power wiring is field provided, solid or stranded, and must comply with all local and national codes. Refer to the engineering manual for detailed electrical data.6. Cooling range with the Low Ambient Baffle Kit (sold separately) is -9.9 F to 122 F.Due to our commitment to continued innovation, some specifications may be changed without notification.6LG Air Conditioning TechnologiesModelCapacityPowerOperating RangeDimensionsWeightSpecificationsHeat Pump / Heat RecoveryTonsNominal Cooling Capacity1Nominal Heating Capacity1Rated Cooling Capacity2Rated Heating Capacity2VoltagePower/Communication Wiring5Cooling Operation Range6Heating Operation RangeDimensions (WxHxD)NetShippingSound Pressure4FanCompressorTypeAir Flow RateTypeOil TypeRefrigerantQuantityCoatingRows/Fins per inchLiquid Line (OD)HP/Vapor Line (OD)LP/Vapor Line (OD)TypeChargeNumber of Indoor Units3ControlMinimum / MaximumHeat ExchangePipingUnitARUB060GSS4Heat Recovery5Btu/hBtu/hBtu/hBtu/h60,000V / Hz / ØNo. x AWG F FinlbslbsdB(A)208-230/60/160,00060,00060,0002 x 1823 to 122-13 to 6137-13/32x54-11/32x1326029157Axial Flow FanCFM3,885Scroll InverterPVE/FVC68D1Gold Fin / Hydrophilic3 / 14inininlbs3/85/83/4R410A7.7EEV2/121. Nominal capacity applied with non-ducted indoor units, and is rated 0 ft. above sea level with 25 ft. of refrigerant line per indoor unit and a 0 ft. level difference between outdoor and indoor units. Allcapacities are net with a Combination Ratio between 95–105%.Nominal cooling capacity rating obtained with air entering the indoor unit at 80 F dry bulb (DB) and 67 F wet bulb (WB) and outdoor ambient conditions of 95 F dry bulb (DB) and 75 F wet bulb (WB).Nominal heating capacity rating obtained with air entering the indoor unit at 70 F dry bulb (DB) and 59 F wet bulb (WB) and outdoor ambient conditions of 47 F dry bulb (DB) and 43 F wet bulb (WB).2. Rated capacity is certified under AHRI Standard 1230. See www.ahrinet.org for information.3. The System Combination Ratio must be between 50–130%.4. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.5. Power wiring is field provided, solid or stranded, and must comply with all local and national codes. Refer to the engineering manual for detailed electrical data.6. Cooling range with the Low Ambient Baffle Kit (sold separately) is down to -9.9 F.Due to our commitment to continued innovation, some specifications may be changed without notification.7

INDOOR UNIT LINE-UPTypekBtu/h57912151824283036424854Art Cool GalleryWallMountedUnitArt Cool MirrorStandard1-Way CassetteCeilingMountedCassette2-Way Cassette4-Way Cassette(2' x 2')4-Way Cassette(3' x 3')Ceiling SuspendedVertical Air Handler Unit (VAHU)Low StaticCeilingConcealedDuctedMid StaticHigh StaticWith CaseFloorStandingWithout CaseOutside Air Unit (OAU)HYDRO KIT MEDIUM TEMPERATURE (K2)ENGINEERING MANUALHydro KitVariable Refrigerant Flow Indoor Units42,000 Btu/h and 96,000 Btu/hLG Electronics USA IncAHRI Certified, Variable Refrigerant Flow (VRF) Multi-Split AC and HP AHRI Standard 1230Air Conditioning Technologies4300 North Point ParkwayAlpharetta, GA 30022www.lghvac.com 2021 LG Electronics. All rights reserved.Document Number: PO MultiV S 05 21

LG Multi V Indoor units operate quietly in the interior space, with rated sound levels as low as 23 dB(A) WHY MULTI V S? The LG Multi V S and Multi V S with LGRED is a compact yet powerful VRF solution for residential and light commercial applications. LG Multi V S utilizes single-phase power so it can be used residentially as well as