FLEXIM - Flexible Industrial MeasurementPRODUCT CATALOGUEClamp-on ultrasonic flow measurementand process analyticsNon-intrusive flowmeasurement withFLUXUS Liquids Gases Thermal energyNon-intrusive processanalytics with PIOX S Concentration Density Mass flow ratePIOX Rprocess refractometer Concentration Density Brix etc.

ContentsNon-intrusive flow measurement with clamp-on ultrasonic technology4TransmittersPortable flowmeters – for non-explosive areas6Portable flowmeters – for potentially explosive areas8Stationary measuring transmitters - for non-explosive areas10Stationary measuring transmitters - for potentially explosive areas12TransducersFor liquid flow measurement14For gas flow measurement15Portable and permanent transducer mounting fixtures16Real-time process analytics219PIOX S ultrasonic process analyser20PIOX R inline process refractometer22

FLEXIMFlexible Industrial Measurement TechnologyMeasurement technology made in Berlin – used worldwideFLEXIM develops, manufactures, and sells advanced process measuring devices for industrial applications.For more than 25 years, non-intrusive ultrasonic flow measurement has its name: FLUXUS . The name PIOX stands for process analytics – non-intrusive with the PIOX S ultrasonic analyser, wetted with the PIOX Rtransmitted light refractometer.If it flows, FLUXUS will measure it.Progressive process analytics with PIOX FLEXIM’s FLUXUS ultrasonic flowmeters are usedwherever something flows. Non-intrusive clamp-onultrasonic technology opens up an unrivalled widerange of applications. FLUXUS reliably measureson very small tubes (e.g. DN 6 tubes in paint finishing systems) and very large pipes (e.g. DN 6500downpipes in hydropower plants).Clamp-on ultrasonic technology can also be usedfor process analytics through non-intrusive determination of the acoustic velocity in the medium.PIOX S ultrasonic systems really stand the test inapplications where wetted measuring equipment issubject to considerable wear and tear, for exampleduring concentration and mass flow measurementsof acids.The field of application is not only limited to liquids.FLEXIM is also particularly proud of its pioneeringwork carried out in transferring ultrasonic technology to the non-intrusive flow measurement ofgases. Clamp-on measuring technology also coversan extraordinary range of applications in this area– from the recording of quantities drawn off by individual pneumatic consumers in a compressed airnetwork, to the non-intrusive measurement of gasquantities conveyed in a gas transmission pipeline.Measurement of light refraction is a proven methodfor determining concentrations. Laboratory accuracy is ensured in the process with the patentedPIOX R transmitted light refractometer.If both measuring methods are combined, multicomponent mixtures can also be analysed accurately and reliably.3

FLUXUS Non-intrusive flow measurement withclamp-on ultrasonic technologyFLUXUS measures flow rates non-intrusively with ultrasound. Clamp-on ultrasonic transducers are simplymounted on the outside of the pipe. The practical advantages are obvious: no wear and tear by the medium flowinginside the pipe, no risk of liquid leakage or fugitive gas emissions, no pressure loss and, above all, unlimited plantavailability.FLUXUS measures the differenceVersatile clamp-on solutionFLUXUS clamp-on ultrasonic systems determine thevolume flow according to the transit-time differencemethod: since the ultrasonic signal that is injectedinto the pipe is carried by the medium flowing inside,a time delay occurs between the acoustic transit timeboth with and against the flow direction. This timedelay can be measured very accurately. The measuringtransmitter calculates the volume flow rate basedon the parameters input for the pipe geometry andthe physical properties of the medium stored in theinternal database.The non-intrusive acoustic measuring method is inertia-free and is characterised by very high measuring dynamics in both flow directions. When combinedwith density measurement, the transit-time difference measurement is suitable for determining thevolume flow rate and mass flow rate of liquids. Whencombined with pressure measurement, it is suitablefor determining the standard volume flow of gases.A particularly practical use for the non-intrusivemeasuring technique is the fact that the currentpower of liquid-based thermal consumers, e.g. heating or cooling systems, can be easily recorded.FLUXUS clamp-on ultrasonic systems allow for theflow measurement of almost all liquid and gaseousmedia – even those with increased inputs of solids andgas ( 10%) or even wet gas (LVF 5%).4As a technology leader in clamp-on ultrasonic systems, FLEXIM has developed two sensor technologies for non-intrusive flow measurement: shearwave transducers for the flow measurement ofliquids and Lamb wave transducers for the flowmeasurement of gases. By means of these two technologies and the internal, automatic compensationof varying ambient temperatures, FLEXIM ensuresmaximum measuring accuracy and reliability, evenunder difficult conditions.

FLEXIMFlexible Industrial MeasurementFundamentally flexibleProven accuracyNon-intrusive clamp-on technology offers maximumflexibility and the sophisticated electronics of FLUXUS ensure the highest degree of reliability. The measuringsystem, which consists of a transmitter and VARIOFIXtransducer system, can be adapted optimally to specific requirements.The reliability and accuracy of measuring systemsdepend on the quality of their manufacturing and calibration. Consistent quality management according toDIN ISO 9001 is absolutely essential for FLEXIM. Fromthe moment the goods arrive at the warehouse to themoment the finished measuring system is shipped,operational checks are carried out at every single production stage and everything is documented. Pairedtransducers ensure high measuring accuracy of themeasuring systems.The product range of the FLUXUS series covers awide spectrum of various measuring transmittersand transducers, from basic devices for standard applications to measuring systems for usage offshore.It goes without saying; this also includes transmittersand transducers which can be used in potentiallyexplosive areas as well as in applications where a SIL2qualification is needed.Calibration is carried out on individual calibrationequipment according to national standards. FLEXIMcalibrates pairs of transducers and measuring transmitters independently of one another so that thenarrowly defined measurement uncertainties arealways observed, regardless of which transducers areused with which measuring transmitters.5

Portable Flow Meters FLUXUS F401 and F601Liquids & Thermal EnergyFLUXUS he portable FLUXUS F401 is a single channel meter for the flow measurementof water and wastewater streams ( 6 % of solid / gas content by volume). It isequipped with IP68 transducers and housed in an IP67 enclosure for long termremote measurements outdoor.Measurement uncertainty 2 % of reading 0.01 m/s(volumetric flow rate):Transmitter:Explosion protection:–Power supply:Power supply unit 100 . 230 V AC / 50 . 60 Hz, 12 V DC (socket at transmitter)integrated battery Li-Ion, up to 60 days operating time (minimum nightflow mode)Outputs:4 - 20 mA passive, pulse / frequency / binaryInputs:–Digital communication: –Available transducers:Explosion protection:–Pipe size range(inner diameter):40 mm . 4700 mmTemperature range(pipe wall):-40 C . 100 CThe portable FLUXUS F601 Energy is the ideal metering solution for flexibleFLUXUS F601(Liquids)operation during temporary control and service tasks on all liquid filled pipesindependent of the flowing medium.Measurement uncertainty(volumetric flow rate): 1 % of reading 0.005 m/sTransmitter:Explosion protection:–Power supply:Power supply unit 100 . 230 V AC / 50 . 60 Hz, 12 V DC (socket at transmitter)integrated battery Li-Ion, 25 h operating timeOutputs:4 - 20 mA active / passive, pulse / frequency / binaryInputs:–Digital communication: Modbus RTUAvailable transducers:Explosion protection:–Pipe size range(inner diameter):6 mm . 6500 mmTemperature range(pipe wall):-40 C . 200 C / WI: -200 C . 600 CFLUXUS F601 Energy The portable FLUXUS F601 Energy is the ideal solution for flexible(Liquids &operation during thermal energy as well as liquid flow metering and associatedThermal Energy)service tasks.Measurement uncertainty(volumetric flow rate): 1 % of reading 0.005 m/sTransmitter:Explosion protection:–Power supply:Power supply unit 100 . 230 V AC / 50 . 60 Hz, 12 V DC (socket at transmitter)integrated battery Li-Ion, 25 h operating timeOutputs:4 - 20 mA active / passive, pulse / frequency / binaryInputs:Pt100 / Pt1000, 4 - 20 mA passiveDigital communication: Modbus RTUAvailable transducers:Explosion protection:–Pipe size range(inner diameter):6 mm . 6500 mmTemperature range(pipe wall):-40 C . 200 C / WI: -200 C . 600 C

Portable Flow Meters FLUXUS G601Gases, Compressed Air, Liquids & Thermal EnergyFLUXUS G601(Gases & Liquids)Measurement uncertainty(volumetric flow rate):LiquidsGasesTransmitter:Explosion protection:Power supply:5921322659213226Outputs:Inputs:Digital communication:Available transducers:Explosion protection:Pipe size range(inner diameter):LiquidsGasesTemperature range(pipe wall):LiquidsGasesThe portable FLUXUS G601 is the ideal metering solution for flexible operationduring temporary control and service tasks on gas filled pipes. It also allows themeasurememt at liquid filled pipes. 1% of reading 0.005 m/s 1.3 % of reading 0.005 m/s, depending on applicationStandardMultifunctional–Power supply unit 100 . 230 V AC / 50 . 60 Hz, 12 V DC (socket at transmitter)integrated battery Li-Ion, 25 h operating time4 - 20 mA active / passive, pulse / frequency / binary–Pt100 / Pt1000, 4 - 20 mA passiveModbus RTU–6 mm . 6500 mm7 mm . 1600 mm-40 C . 200 C / WI: -200 C . 600 C-40 C . 200 CThe portable FLUXUS G601 CA Energy is the ideal metering solution for flexibleFLUXUS G601 CAoperation during temporary control and service tasks. It allows the measurementEnergyof liquids, gases (incl. compressed air) and thermal energy quantities combined(Gases, Compressed Air,Liquids & Thermal Energy) in one device.Measurement uncertainty(volumetric flow rate):Liquids 1% of reading 0.005 m/sGases 1.3 % of reading 0.005 m/s, depending on applicationTransmitter:Explosion protection:–Power supply:Power supply unit 100 . 230 V AC / 50 . 60 Hz, 12 V DC (socket at transmitter)integrated battery Li-Ion, 25 h operating timeOutputs:4 - 20 mA active / passive, pulse / frequency /binaryInputs:Pt100 / Pt1000, 4 - 20 mA passiveDigital communication: Modbus RTUAvailable transducers:Explosion protection:–Pipe size range(inner diameter):Liquids6 mm . 6500 mmGases7 mm . 1600 mmTemperature range(pipe wall):Liquids-40 C . 200 C / WI: -200 C . 600 CGases-40 C . 200 C7

Portable Flow Meter FLUXUS F608Liquids & Thermal EnergyATEX (IECEx) Zone 2, FM Class I, Div. 2 certified(Transducers certified for ATEX (IECEx) Zones 1 and 2, FM Class I, Div. 2)FLUXUS F608(Liquids)59213226The portable FLUXUS F608 is the ideal metering solution for flow measurements on liquid filled pipes located in hazardous areas being ATEX (IECEx) Zone 2and FM Class I, Div. 2 certified.Measurement uncertainty(volumetric flow rate): 1 % of reading 0.005 m/sTransmitter:Explosion protection:ATEX/IECEx zone 2, FM Class I, Div. 2Power supply:Power supply unit 100 . 230 V AC / 50 . 60 Hz, only for use in non-ex areas12 V DC (socket at transmitter) integrated battery Li-Ion, 25 h operating timeOutputs:4 - 20 mA active / passive, pulse / frequency / binaryInputs:–Digital communication: –Available transducers:Explosion protection:ATEX/IECEx zone 1 / zone 2, FM Class I, Div. 2Pipe size range(inner diameter):6 mm . 6500 mmTemperature range(pipe wall):-40 C . 200 C / WI: -200 C . 600 CFLUXUS F608 EnergyThe portable FLUXUS F608 Energy is the ideal liquid flow as well as thermal(Liquids & Thermal Energy) energy metering solution for applications located in hazardous areas being ATEX(IECEx) Zone 2 and FM Class I, Div. 2 certified.592132268Measurement uncertainty(volumetric flow rate): 1 % of reading 0.005 m/sTransmitter:Explosion protection:ATEX/IECEx zone 2, FM Class I, Div. 2Power supply:Power supply unit 100 . 230 V AC / 50 . 60 Hz, only for use in non-ex areas12 V DC (socket at transmitter) integrated battery Li-Ion, 25 h operating timeOutputs:4 - 20 mA active / passive, pulse / frequency / binaryInputs:Pt100 / Pt1000Digital communication: –Available transducers:Explosion protection:Pipe size range(inner diameter):Temperature range(pipe wall):ATEX/IECEx zone 1 / zone 2, FM Class I, Div. 26 mm . 6500 mm-40 C . 200 C / WI: -200 C . 600 C

Portable Flow Meters FLUXUS G608Gases, Compressed Air, Liquids & Thermal EnergyATEX (IECEx) Zone 2, FM Class I, Div. 2 certified(Transducers certified for ATEX (IECEx) Zones 1 and 2, FM Class I, Div. 2)FLUXUS G608(Gases & Liquids)Measurement uncertainty(volumetric flow rate):LiquidsGasesTransmitter:Explosion protection:Power supply:Outputs:5921322659213226Inputs:Digital communication:Available transducers:Explosion protection:Pipe size range(inner diameter):LiquidsGasesTemperature range(pipe wall):LiquidsGasesThe portable FLUXUS G608 is the ideal metering solution for flow measurements on gas pipes located in hazardous areas being ATEX (IECEx) Zone 2 and FMClass I, Div. 2 certified. It also allows the measurememt at liquid filled pipes. 1% of reading 0.005 m/s 1.3 % of reading 0.005 m/s, depending on applicationATEX/IECEx zone 2, FM Class I, Div. 2Power supply unit 100 . 230 V AC / 50 . 60 Hz, only for use in non-ex areas12 V DC (socket at transmitter) integrated battery Li-Ion, 25 h operating time4 - 20 mA active / passive, pulse / frequency / binary (only available forATEX/IECEx Zone 2 approved version)––ATEX/IECEx zone 1 / zone 2, FM Class I, Div. 26 mm . 6500 mm7 mm . 1600 mm-40 C . 200 C / WI: -200 C . 600 C-40 C . 200 CThe portable FLUXUS G608 CA Energy is a meter that can measure liquid andFLUXUS G608gas (incl. compressed air) flow rates as well as quantify thermal energy flows. ItCA Energyis specifically designed for use in hazardous areas and thus ATEX (IECEx) Zone 2(Gases, Compressed Air,Liquids & Thermal Energy) and FM Class I, Div. 2 certified.Measurement uncertainty(volumetric flow rate):Liquids 1% of reading 0.005 m/sGases 1.3 % of reading 0.005 m/s, depending on applicationTransmitter:Explosion protection:ATEX/IECEx zone 2, FM Class I, Div. 2Power supply:Power supply unit 100 . 230 V AC / 50 . 60 Hz, only for use in non-ex areas12 V DC (socket at transmitter) integrated battery Li-Ion, 25 h operating timeOutputs:4 - 20 mA active / passive, pulse / frequency / binaryInputs:Pt100 / Pt1000Digital communication: –Available transducers:Explosion protection:ATEX/IECEx zone 1 / zone 2, FM Class I, Div. 2Pipe size range(inner diameter):Liquids6 mm . 6500 mmGases7 mm . 1600 mmTemperature range(pipe wall):Liquids-40 C . 200 C / WI: -200 C . 600 CGases-40 C . 200 C9

Stationary TransmittersLiquids (F) and Thermal Energy (F-TE)Non-ex and ATEX (IECEx) Zone 2, FM Class I, Div. 2 certifiedFLUXUS F50XThe FLUXUS F50X is a basic meter available in dedicated solution packages(Water & Thermal Energy) for water, thermal energy and flexible tubing applications. The basic meterFLUXUS F501 is designed for water / glycol applications, in connection with IP68rated transducers allowing for measurements at buried water supply lines.103140Ø 4.5Ø 8.41651071180Measurement uncertainty(volumetric flow rate): 1.5% of reading 0.01 m/sTransmitter:F501F502 TE – ThermalEnergy (Water only)Explosion protection:–Power supply:100 . 230 V AC / 50 . 60 Hz, 12 / 24 V DCOutputs:4 - 20 mA active, pulse / binaryInputs:–Pt100 / Pt1000Digital communication: Modbus RTU, BACnet , MS/TP, M-BusAvailable transducers:Explosion protection:–Pipe size range(inner diameter):10 mm . 2400 mm25 mm . 500 mmTemperature range(pipe wall):-40 C . 100 C-40 C . 100 CFLUXUS F721F501 Semiconductor(for liquids in tubes)–OD ⅜'', ½'', ¾'', 1'', 1¼'',1½''-20 C . 100 CThe non-invasive FLUXUS F721 ultrasonic liquid flow meter is settingstandards in terms of measurement performance. In conjunction with theF704 TE for thermal energy metering, they are the state-of-the art meters inFLUXUS F704 TE(Liquids & Thermal Energy) terms of accuracy and reliability. (Liquids)Measurement uncertainty(volumetric flow rate): 1% of reading 0.005 m/sTransmitter:F721Explosion protection:Power supply:Outputs:Inputs:Digital communication:Available transducers:Explosion protection:108,5261B329106,212,2Pipe size range(inner diameter):Temperature range(pipe wall):FLUXUS F706(Liquids)Measurement uncertainty(volumetric flow rate):Transmitter:Explosion protection:Power supply:Outputs:287265163200Ø 4.5701010Inputs:Digital communication:Available transducers:Explosion protection:Pipe size range(inner diameter):Temperature range(pipe wall):F704 TE – Thermal EnergyATEX/IECEx Zone 2, FM Class I /Div 2100 . 230 V AC / 50 . 60 Hz, 12 / 24 V DC4 - 20 mA active / passive, pulse / frequency / binaryPt100 / Pt1000, 4 - 20 mA active /Pt100 / Pt1000passive, binaryModbus RTU/TCP, BACnet MSTP/IP,Modbus RTU, HART, BACnet MS/TP,M-Bus, Profibus PA, Foundation Fieldbus M-BusATEX/IECEx Zone 1 /Zone 2 FM Class I / Div2–6 mm . 6500 mm25 mm . 1000 mm-40 C . 240 C / WI: -200 C . 600 C -40 C . 200 CThe non-invasive 4-channel ultrasonic liquid flow meter FLUXUS F706 offershighest precision and is used for control and redundancy measurements ofcustody transfer meters or for usage in protective systems for leak detection. 1% of reading 0.005 m/sATEX/IECEx zone 2, FM Class I /Div 2100 . 230 V AC / 50 . 60 Hz, 12 / 24 V DC4-20 mA active /passive, 4-20 mA HART active/passive,pulse / frequency / binaryPt100 /Pt1000, 4-20 mA active /passive binaryModbus RTU, Foundation FieldbusATEX/IECEx zone 1 / zone 2 FM Class I / Div26 mm . 6500 mm-40 C . 240 C / WI: -200 C . 600 C** SIL2 approved products are available

Stationary TransmittersWater (WD) and Gases (G & CA)Non-ex and ATEX (IECEx) Zone 2, FM Class I, Div. 2 certifiedFLUXUS F721WD(Water)Measurement uncertainty(volumetric flow rate):Transmitter:Explosion protection:Power supply:Outputs:Inputs:Digital communication:108,5261B329106,212,2Available transducers:Explosion protection:Pipe size range(inner diameter):Temperature range(pipe wall):FLUXUS G721 (Gases)FLUXUS G704CA(Compressed Air)The FLUXUS F721WD is the ideal flow metering solution for water suppliers.With their IP68 rated transducers the meters can easily be buried underground andwork on even the most difficult pipes. 1% of reading 0.005 m/s–100 . 230 V AC / 50 . 60 Hz, 12 / 24 V DC4 - 20 mA active / passive, 4 - 20 mA HART active /passive, pulse / frequency / binary–Modbus RTU/TCP, BACnet MSTP/IP, M-Bus, Profibus PA, Foundation Fieldbus–50 mm . 6500 mm-40 C . 130 CThe non-invasive FLUXUS G721 ultrasonic gas flow meter is FLEXIM‘s mostadvanced gas flow meter. Engineered for highly precise measurements under allcircumstances, it is the state-of-the-art flow meter for any gaseous medium.Measurement uncertainty(volumetric flow rate): 1.3 % of reading 0.005 m/s, depending on applicationTransmitter:G721G704CACompressed Air and Industrial GasesExplosion protection:ATEX/IECEx zone 2, FM Class I /Div 2–Power supply:100 . 230 V AC / 50 . 60 Hz, 12 / 24 V DCOutputs:4 - 20 mA active, 4- 20 mA HART active / passive, pulse / frequency / binary108,5261B329106,212,2Inputs:Pt100 / Pt1000, 4 - 20 mA active / passive, binaryDigital communication:Modbus RTU/TCP, BACnet MSTP/IP,Modbus RTU, BACnet MS/TP, M-BusM-Bus, Profibus PA, Foundation FieldbusAvailable transducers:Explosion protection:Pipe size range (innerdiameter):Temperature range(pipe wall):FLUXUS G706(Gases)Measurement uncertainty(volumetric flow rate):Transmitter:Explosion protection:Power supply:Outputs:287265163200Ø 4.57010Inputs:Digital communication:Available transducers:Explosion protection:Pipe size range(inner diameter):Temperature range(pipe wall):ATEX/IECEx Zone 2, FM Class I /Div 2–7 mm . 1600 mm7 mm . 250 mm-40 C . 240 C-40 C . 150 CThe non-invasive 4-Channel ultrasonic gas flow meter FLUXUS G706 offershighest precision and is used for control and redundancy measurements ofcustody transfer meters or for usage in protective systems for leak detection. 1.3 % of reading 0.005 m/s, depending on applicationATEX/IECEx zone 2, FM Class I, Div. 2100 . 230 V AC / 50 . 60 Hz, 12 / 24 V DC4 - 20 mA active / passive, 4 - 20 mA HART active / passive,pulse / frequency / binaryPt100 / Pt1000, 4 - 20 mA active / passive, binaryModbus RTU, Foundation FieldbusATEX/IECEx zone 1 / zone 2, FM Class I, Div. 27 mm . 1600 mm-40 C . 240 C11

Stationary TransmittersLiquids (F)ATEX (IECEx) Zone 1, FM Class I, Div. 1 certifiedFLUXUS F809(Liquids)Measurement uncertainty(volumetric flow rate):Transmitter:Explosion protection:Power igital communication:Available transducers:Explosion protection:Pipe size range(inner diameter):Temperature range(pipe wall):FLUXUS F801(Liquids)Measurement uncertainty(volumetric flow rate):Transmitter:Explosion protection:Power supply:Outputs:189178Ø 132195Inputs:Digital communication:Available transducers:Explosion protection:Pipe size range(inner diameter):Temperature range(pipe wall):FLUXUS F808 (Liquids)FLUXUS F808LF(Liquids, low flow productvariant)The FLUXUS F809 is an ATEX (IECEx) zone1 and FM Class I, div. 1 approved dualchannel liquid flow meter for any industrial environment. It can even be employedat extreme temperatures ranging from -190 C up to 600 C. 1% of reading 0.005 m/sATEX/IECEx zone 1, FM Class I /Div 1100 . 230 V AC / 50 . 60 Hz, 24 V DC4-20 mA active /passive, 4-20 mA HART active / passive,4 - 20 mA HART passive intrinsic safety, pulse / frequency / binary–Modbus RTUATEX/IECEx zone 1 / FM Class I / Div 16 mm . 6500 mm-40 C . 240 C / WI: -200 C . 600 CThe clamp-on ultrasonic liquid flow meters FLUXUS F801 are, with their highlycorrosion resistant stainless steel enclosures, the ideal meters for usage offshore(ATEX/IECEx Zone 1 certified). 1% of reading 0.005 m/sATEX/IECEx zone 1100 . 230 V AC / 50 . 60 Hz, 24 V DC4-20 mA active /passive, 4-20 mA HART active / passive,4 - 20 mA passive intrinsic safety, pulse / frequency / binary–Modbus RTUATEX/IECEx zone 16 mm . 6500 mm-40 C . 240 C / WI: -200 C . 600 CThe FLUXUS F808 is an ATEX (IECEx) zone1 and FM Class I, div. 1 approvedsingle channel liquid flow meter. As special product variant „FLUXUS F808LF“,it is engineered to measure extremely low flows.Product variant:FLUXUS F808Measurement uncertainty 1% of reading 0.005 m/s(volumetric flow rate):9.575.3512Transmitter:Explosion protection:Power supply:Outputs:Inputs:Digital communication:Available transducers:Explosion protection:Pipe size range(inner diameter):Temperature range(pipe wall):FLUXUS 808LF 1,2 % of reading 0,08/(N*ID) with N number of sound paths(e.g. 1,2 % of reading 0,001 m/swith ID 10 mm, N 8)ATEX/IECEx zone 1100 . 230 V AC / 50 . 60 Hz, 24 V DC4-20 mA active / passive, 4-20 mA HART active / passive, pulse / frequency / binary–Modbus RTUATEX/IECEx zone 16 mm . 6500 mm-40 C . 240 C / WI: -200 C . 600 C10 mm . 50 mm

Stationary TransmittersGases (G)ATEX (IECEx) Zone 1, FM Class I, Div. 1 certifiedFLUXUS G809(Gases)Measurement uncertainty(volumetric flow rate):Transmitter:Explosion protection:Power igital communication:Available transducers:Explosion protection:Pipe size range(inner diameter):Temperature range(pipe wall):FLUXUS G801(Gases)Measurement uncertainty(volumetric flow rate):Transmitter:Explosion protection:Power supply:Outputs:195Ø 132178189Inputs:Digital communication:Available transducers:Explosion protection:Pipe size range(inner diameter):Temperature range(pipe wall):The FLUXUS G809 is an ATEX (IECEx) zone1 and FM Class I, div. 1 approved dualchannel gas flow meter for any industrial environment. It accurately and reliablymeasures any gaseous medium. 1.3 % of reading 0.005 m/s, depending on applicationATEX/IECEx zone 1, FM Class I /Div 1100 . 230 V AC / 50 . 60 Hz, 24 V DC4 - 20 mA active / passive, 4 - 20 mA HART active / passive,4 - 20 mA HART passive intrinsic safety, pulse / frequency / binary–Modbus RTUATEX/IECEx zone 1 / FM Class I / Div 17 mm . 1600 mm-40 C . 240 CThe clamp-on ultrasonic gas flow meters FLUXUS G801 are, with their highlycorrosion resistant stainless steel enclosures, the ideal meters for usage offshore(ATEX/IECEx Zone 1 certified). 1.3 % of reading 0.005 m/s, depending on applicationATEX/IECEx zone 1100 . 230 V AC / 50 . 60 Hz, 24 V DC4 - 20 mA active / passive, 4 - 20 mA HART active / passive,4 - 20 mA passive intrinsic safety, pulse / frequency / binary–Modbus RTUATEX/IECEx zone 17 mm . 1600 mm-40 C . 240 C13

Clamp-On Ultrasonic TransducersFor the flow measurement of liquidsFLEXIM has developed two transducer technologies in orderto ensure the highest possible measuring accuracy even inchallenging environments: shear wave transducers with a focused signal insertion for measuring liquids and Lamb wavetransducers with a wide signal insertion into the medium formeasuring the flow of gases.In order to guarantee measurements with long-term stabilityin harsh industrial environments, the transducers and cableconnections are made of stainless steel and are available inexplosion-proof designs.Shear wave 0Inner pipe diameter in mm(no limitations by pipe wall thickness or pipe wall material)Shear wavetransducersfor liquids:FSSFSQFSP / FSMFSKFSGDimensions of standardtransducersin mm (l x w x h):25 x 13 x 1739 x 22 x 25.562.5 x 32 x 40.5126.5 x 51 x 67.5129.5 x 51 x 67Operating temp.:(ext. temp. area):-30 C . 130 C-40 C . 130 C(-30 C . 200 C)-40 C . 130 C(-30 C . 200 C)-40 C . 130 C-40 C . 130 CProtection degree:IP65IP65, IP67 optionalIP65, IP68 optionalIP65, IP68 optionalIP65, IP68 optionalHazardous areaapproval:FM Class I, Div. 2ATEX (IECEx)Zone 1 and 2FM Class I,Div. 1 / 2ATEX (IECEx)Zone 1 and 2FM Class I,Div. 1 / 2ATEX (IECEx)Zone 1 and 2FM Class I, Div. 1/ 2ATEX (IECEx)Zone 1 and 2FM Class I, Div. 1 / 2(also availableas metal-freeproduct variant)Techn. drawing:14

Clamp-On Ultrasonic TransducersFor the flow measurement of gasesLamb wave TransducersShear wave Transducers*TypTypup to 35 mmPipe wall thicknessGLF 11 mm Pipewall thicknessGSGGLGGSKGLHGLK 5 mm Pipe wall thicknessGSMGLM 2 mm Pipe wall thicknessGSPGLPGLQ 1 mm Pipe wall thicknessGSQ51050100500100052000Inner pipe diameter in mm 0,6 mm Pipe wall thickness105010050010002000Inner pipe diameter in mm*Applications with pipe wall thicknesses that are not within the rangeof Lamb wave transducersLamb wave transd.Shear wave transd.*for gases:GLQ-GLP / GLMGSP / GSMGLH / GLKGSKGLGGSGGLF-Dimensions of standard 42 x 22 x 25.5transducersin mm (l x w x h):74 x 32 x 40.5128.5 x 51 x 67.5128.5 x 51 x 67.5163 x 54 x 91.3Operating temp.:-40 C . 170 C-40 C . 170 C-40 C . 170 C-40 C . 170 C-40 C . 170 CProtection degree:IP65, IP68 optionalIP65, IP68 optionalIP65, IP68 optionalIP65, IP68 optionalIP65Hazardous areaapproval:ATEX (IECEx)ATEX (IECEx)ATEX (IECEx)ATEX (IECEx)ATEX (IECEx)Zone 1 and 2Zone 1 and 2Zone 1 and 2Zone 1 and 2Zone 1 and 2FM Class I, Div. 1 / 2 FM Class I, Div. 1 / 2 FM Class I, Div. 1 / 2 FM Class I, Div. 1 / 2 FM Class I, Div. 1 / 2Techn. drawing:* dimensions and design are varying to the Lamb wave transducers15

Transducer Mounting FixturesWhether for quick installations during temporarymeasurement or for permanent installations,whether for large pipes or small tubes: FLEXIMoffers the right transducer mounting fixture forevery application.VARIOFIX transducer systems offer the best stability:the sturdy mounting devices permanently ensurethe ultrasonic transducers are positioned precisely.Sophisticated, constructive details guarantee constantly high contact pressure even with high fluctuations intemperature thereby ensuring long-term stable highsignal quality.VARIOFIX L is the standard transducer mounting fixturefor permanent installation. VARIOFIX C provides optimum protection even under the harshest conditions:below the stainless steel cover, the measuring point ispermanently protected from external influences, fromwind and weather as well as from mechanical damage.When the going gets toughFLEXIM invented the WaveInjector for extreme temperatures. The patented device separates the ultrasonic transducers thermally from the pipe therebyextending the application range of non-intrusiveclamp-on ultrasonic technology to temperaturesfrom -190 C to 600 C.The WaveInjector is a transducer mounting device andso much heat is radiated or absorbed via its metalliccoupling plates that the temperature of the transducerclamping fixture lies within the working range of theultrasonic transducers.The WaveInjector is also mounted on the outside of the pipe without having to open the pipeline.Since it is a purely mechanical arrangement, theWaveInjector can also be used in hazardous areas.For temporarymeasurementsPortableMounting Fixtures:Portable VARIOFIX(Chains / Magnets)Fastening Shoes (FS)(Chains / Magnets)Tension BeltsDescription:The portable VARIOFIX is the stan- The fastening shoes (FS) ar

Clamp-on ultrasonic technology can also be used for process analytics through non-intrusive deter-mination of the acoustic velocity in the medium. PIOX S ultrasonic systems really stand the test in applications where wetted measuring equipment is subject to considerable wear and tear, for example during concentration and mass flow measurements