RAILROAD & DIESEL STARTER - Rolls Battery

Transcription

RAILROAD & DIESEL STARTER

R A I L ROA D & D I E S E L STA RT E R S E R I E SDesigned to meet and exceed the performance requirements of the Railroad Industry,Rolls heavy-duty models deliver heavy-duty plate construction, 180 day liquid reservesand superior cycle life in durable high-temperature retardant & moisture-tight cases.

8 N S 33P16 C H 3 5 P8 NS 23PC O N T E N T S02Flooded Railroad & Diesel Starter Series08Distilled Water048 Volt Models09Model Cross Reference0632 Volt Models10Contacts

F L O O D E D RA I L R OA D &D I E S E L STA RT E R BATT E R I E SRolls Railroad & Diesel Starter 4-volt & 6-volt flooded battery models offerheavy-duty plate construction in dual container design. Each modular 2-voltcell is securely bolted and fully protected in the high temperature-retardantand moisture-tight outer container.SERIESMODEL8 HRRATE20 HR RATECCA @-17 C (0 F)CCA @ 0 C(32 F)LENGTHIN CMWIDTHIN CMHEIGHTIN CMWEIGHTLBS KG8.25in 21.0cm18.25cm 46.4cm128lbs 58kg124.5lbs 56.5kgRO LL S B AT TE RY 4 0 0 0 S E R I E S: 4 VO LT40004 CH 23P5416291893236714.38in 36.5cmRO LL S B AT TE RY 4 0 0 0 S E R I E S: 6 VO LT40006 HHG 31P2963441337167120.75in 52.7cm8.00in 20.3cm11.88in 30.2cm40006 EHG 31P3534101549193620.75in 52.7cm8.00in 20.3cm12.75in 32.4cmSpecial orders and discontinued models available upon request.All capacities based on specific gravities of 1.280. Reduce capacity 5% for 1.256 specific gravity and 10% for 1.250 specific gravity.02 Railroad & Diesel Starter132.5lbs 60kg

6 H H G 31PF E AT U R E S Non-breakable dual-container construction4 CH 23P Modular, bolted 2 volt cells Computer-controlled formation Environmentally friendly; moisture-tightouter cover Load and capacity tested prior to shipping 5 year warrantyRailroad & Diesel Starter 03

8 V O LT M O D E L SSERIESMODEL8 HRRATE20 HR RATECCA @-17 C (0 F)CCA @ 0 C(32 F)LENGTHIN CMWIDTHIN CMHEIGHTIN CMWEIGHTLBS KGRO LL S B AT TE RY 4 0 0 0 & 50 0 0 S E R I E S: 8 VO LT40008 HHG 31P2963441337167127.00in 68.6cm8.00in 20.3cm11.88in 30.2cm166.5lbs 75.5kg40008 EHG 31P3534101549193627.00in 68.6cm8.00in 20.3cm12.75in 32.4cm177.5lbs 80.5kg50008 CH 17SP3784401377172120.75in 52.7cm8.25in 21cm17.5in 44.5cm216lbs 147kg50008 NS 23P4024681559194928.25in 109.2cm8.25in 21cm18.25in 46.4cm241.5lbs 109.5kg50008 CH 23P5416291893236728.25in 109.2cm8.25in 21cm18.25in 46.4cm255.5lbs 116kg50008 CH 23P-QR5416291893236728.25in 109.2cm8.25in 21cm16.63in 42.2cm255.5lbs 116kg50008 NS 33P5866812268283528.25in 109.2cm11.25in 28.6cm18.25in 46.4cm351.5lbs 159.5kg50008 CH 33P7889162754344328.25in 109.2cm11.25in 28.6cm18.25in 46.4cm413.5lbs 187.5kgSpecial orders and discontinued models available upon request.All capacities based on specific gravities of 1.280. Reduce capacity 5% for 1.256 specific gravity and 10% for 1.250 specific gravity.04 Railroad & Diesel Starter

CC AT 32ºF (0ºC)350 03000250 020000C O M P E T I TO R ’ SC O M PA R A B L EB AT T E RY8 CH 33PM U LT I - P L AT EF E AT U R E S8 CH 33P 33% higher cranking capacity at 0 C (32 F)Railroad & Diesel Starter 05

3 2 V O LT M O D E L SSERIESMODEL8 HRRATE20 HR RATECCA @-17 C (0 F)CCA @ 0 C(32 F)LENGTHIN CMWIDTHIN CMHEIGHTIN CMWEIGHTLBS KGRO LL S B AT TE RY 50 0 0 S E R I E S: 32 VO LT500016 CS 15P4284971219152426.95in 68.5cm27in 68.6cm20.50in 52.1cm1040lbs 471.50kg500016 CH 25P5906862066258233.67in 85.5cm27in 68.6cm20.50in 52.1cm1238lbs 561.50kg500016 CH 33P7889162754344343in 109.2cm27in 68.6cm20in 50.8cm1608lbs 729.50kg500016 CH 35P8059362926365843in 109.2cm27in 68.6cm20in 50.8cm1672lbs 758.50kgSpecial orders and discontinued models available upon request.All capacities based on specific gravities of 1.280. Reduce capacity 5% for 1.256 specific gravity and 10% for 1.250 specific gravity.OPTIONALCELL CONNECTIONIf a cell replacement is necessary, Rolls Railroad & Diesel Starter modelsoffer a quick solution. As an option, individual modular 2 volt cells canbe bolted together, allowing straight-forward replacement or assemblyto be done on location.06 Railroad & Diesel Starter

S A F E T Y, D U R A B I L I T Y A N DE N V I R O N M E N TA L LY- F R I E N D LY D E S I G NRolls non-breakable dual-container construction virtuallyeliminates breakage due to rough handling or high stressinstallations. Individual heat-sealed, modular 2-volt cells aresecurely connected and self-contained in a high temperatureretardant moisture-tight polypropylene outer case & cover,eliminating the potential for short circuits from water, dirtor falling objects. Should the outer container become puncturedor damaged, the protected cells would remain operable withno sulfuric acid spills.16 C H 3 3 PF E AT U R E S Widest range of specifications available Industry’s largest liquid reserve Higher crank Amps Non-breakable dual-container construction Computer-controlled formation E nvironmentally friendly; moisture-tightouter coverR U G G E D P L AT E C O N S T R U C T I O NRolls tough positive plates are the thickest in the industry andare double insulated for durability & protection. Each plateand its matting are sealed in a non-destructible micro-porouspolyethylene envelope, eliminating the possibility of misalignment,cracked separators, or shorting at the bottom or sides.Rolls superior heavy-duty Rezistox plate design uses fewer butheavier members in the grid structure, offering increased resistanceto positive grid corrosion and a higher percentage of oxide pastematerial and resulting capacity in each plate. Load and capacity tested prior to shipping 5 year warrantyRailroad & Diesel Starter 07

D I S T I L L E D WAT E RD E S I G N E D F O R 1 8 0 D AYWAT E R I N G I N T E RVA L SAll flooded lead acid batteries, in the course of normal operation, off-gashydrogen and oxygen from water in the electrolyte during routine charging.It is important to maintain adequate electrolyte levels in each cell as batteryplates must be completely submerged when charging to prevent cell damage.To prevent cell damage, electrolyte levels must be monitored regularly anddistilled water should be added as necessary. Each cell should be filled to1/2” – 1/4” below the vent tube to prevent overflow when the battery isplaced on charge.Cold temperatures and extended open circuit stands will cause electrolytelevels to drop. Under these conditions, where electrolyte levels are still abovethe plates, it is recommended that the batteries be placed on charge for3 – 6 hours before filling.Note: If routine specific gravity readings note a gradual decrease or consistentlyremain 0.10 to 0.020 points below a fully charged state, the programmedchargevoltage or time may be too low for the locomotive’s work scheduleand should be increased. Excessive water consumption indicates the chargevoltage may be too high. Charge adjustments should be made in 0.5 voltincrements, monitoring the state of charge and specific gravity after eachadjustment to determine if an additional changes are necessary.E L E C T R O LY T ER E S E RV E4.75”3.75”3 .15 ”C O M P E T I TO R ’ SC O M PAT I B L E M O D E L08Extended liquid reserves safeguard against cell damage.RO LL S16 C H 3 3 P Railroad & Diesel StarterROLL S8 N S 33P / 8 NS 33PRolls trusted heavy-duty models offer ample liquid reservesto safely meet a 180 day maintenance schedule. Dual-containerconstruction virtually eliminates breakage, cell damage oracid leaks typically caused by rough handling or high-stressinstallations. Each modular 2 volt cell is securely welded orfully protected in the high temperature-retardant and moisturetight outer container, preventing short circuits from water,dirt or falling objects.

M O D E L C RO S S R E F E R E N C ERO LL SR E PL AC E SMODELDESCRIPTIONGEEXIDEGNBCROWN8 HHG 21P8HHG21PR 8V BATTERYLP-8178 HHG 25P8HHG25PR 8V BATTERYLP-8198 HHG 29P8HHG29PR 8V BATTERYLP-8218 HHG 31P8HHG31PR 8V BATTERYLP-8258 CH 17SP8CH17SPR 8V BATTERY8 CH 17ER8CH17ER 8V BATTERY8 NS 23P8NS23PR 8V BATTERY8 CH 23P8CH23PR 8V BATTERY8 CH 23P-QR8CH23P-QR 8V BATTERY8 NS 33P8NS33PR 8V BATTERY8 CH 33P8CH33PR 8V BATTERY16 CS 15P16CS15R 32V BATTERY16 CH 25P16CH25R 32V BATTERY16 CH 33P16 CH 35P4-LMS-11JMAEAST PENNJMA-M4513DL-3000SEMDFIRSTNATIONAL4 DS 280DL-3000L4-LMS-3253X95404 LMS-4204 LMS-450KDZ-2701MD-517JMA-M4517DL-40004 DS CH33R 32V BATTERYLMUD-660KDZ65116CH35R 32V 525JMA-U525DL-U65040084033JMA-U531Verify dimensions of battery compartment.Railroad & Diesel Starter 09

C O N TAC T SSurrette Battery Company Ltd.PO Box 20201 Station Road, SpringhillNova Scotia, CanadaB0M 1X0Phone1-902-597-3767 1-800-681-9914Fax1-902-597-8447 1-800-681-9915Customer comSales1-902-597-3767 1-800-681-9914sales@rollsbattery.comTechnical Service1-902-597-3767 1-800-681-9914support@rollsbattery.comTechnical Support Ticketsupport.rollsbattery.com10 Railroad & Diesel Starter

N OT E SV1-7

ROLLSBATTERY.COM

model description ge exide gnb crown jma east penn emd first national 8 hhg 21p 8hhg21pr 8v battery lp-817 8 hhg 25p 8hhg25pr 8v battery lp-819 8 hhg 29p 8hhg29pr 8v battery lp-821 8 hhg 31p 8hhg31pr 8v battery lp-825 8 ch 17sp 8ch17spr 8v battery 4-lms-11 jma-m4513 dl-3000s 4 ds 280 8 ch 17er 8ch17er 8v battery dl-3000l