Hot Water Maker: Hot Water Maker Brochure, Commercial

Transcription

Boiler Mate SeriesCommercialHot WaterMaker Indirect-FiredWater HeatersModels WH-7Cand WH-10C1

INNOVATIVE DESIGN FOR REAL WORLD APPLICATIONSThe Boiler Mate Series commercial Hot Water Maker design combines rapid, highlyefficient recovery with a unique thermal storage system. Meets today's commercialand institutional hot water demands with miminum energy requirements.Sized and applied to meet "real world " building demands, rather than traditional“fixture unit” theoretical demands, the Hot Water Maker system dramatically slashesthe cost of providing hot water to the commercial, institutional or industrial building.Business & Industry2RetrofitApartment HousesMedical Facilities

UNIQUE FEATURESPROVIDE GREATERFLEXIBILITY INAPPLICATION ANDSYSTEM DESIGNHigh Capacity Heat Exchangers Superior AMTROL heat transfertechnology since 1946. Advanced integrated recovery andstorage design for uniform temperatures. Multiple parallel circuits improve heattransfer. Minimal scale formation. Rapid recovery. Available in single- or double-wallconstruction.Flexible & Efficient Modular Design Easily matched and banked with multiple,low-mass, compact boilers with stagedfiring controls. Fuel use proportional to hot waterdemand cycles. Modular design allows exemption fromcostly ASME code requirements.Designed to Meet “Real World”ConditionsFitness Centers Sizing based on actual, monitored hotwater usage. High overall operating efficiencies andreduced operating costs. Peak usage demands with balancedstorage to provide cost effective capacityduring low use periods. Lower maintenance and replacementcosts. Elilminates need for bulky storage tanks.3

AMTROL WH-7C SERIES SPECIFICATIONSSpecifications and terinchesShippingWeight (lbs.)WH-7C414822140WH-7C-DW414822150DW denotes double wall heat exchanger.System ConnectionsCold WaterInlet3/4”Hot ” NPTM1” NPTMDrain3/4”NPTAMTROL WH-7CCommercial Hot Water MakerR Q8.25 TWhere T Differencebetween water inlet and hotwater supply temperaturesR Recovery - GPHQ Boiler Output - BTUH(1) Gallons per hour of domestic water flowthat absorbs boiler heat output atcontinuous flow. (High limit set aboveboiler water temperature).(2) The approximate temperature the boilerwater will reach when the units deliverthe recovery capacity. It is not arecommended high-limit setting, butrather a measurement of the boilerwater temperature when the heater hasreached its steady-state condition atcontinuous flow.Based on 7 GPM Boiler Flow.Temperatures in Degrees F,Boiler Outputs in MBH,Recovery Capacities in Gal./Hr.4STEADY STATE RECOVERY(1)40 F Water Inlet TemperatureHot Water Supply Temperature120 RecoveryBoilerGPH (R) Output (Q)282186 MBH130 RecoveryBoilerGPH (R) Output (Q)235174 MBH140 Recovery BoilerGPH (R) Output (Q)197163 MBHBoilerWaterTemp.(2)180 312206 MBH268199 MBH226187 MBH190 348230 MBH294218 MBH251207 MBH200 50 F Water Inlet TemperatureHot Water Supply Temperature120 RecoveryBoilerGPH (R) Output (Q)314181MBH130 RecoveryBoilerGPH (R) Output (Q)256169 MBH140 Recovery BoilerGPH (R) Output (Q)211157 MBHBoilerWaterTemp.(2)180 347200 MBH290191 MBH240178 MBH190 385222 MBH320211 MBH270200 MBH200 60 F Water Inlet TemperatureHot Water Supply Temperature120 RecoveryBoilerGPH (R) Output (Q)360178 MBH130 RecoveryBoilerGPH (R) Output (Q)288166 MBH140 Recovery BoilerGPH (R) Output (Q)234154 MBHBoilerWaterTemp.(2)180 396196 MBH324187 MBH264174 MBH190 438217 MBH360208 MBH300198 MBH200

AMTROL WH-7C SERIES DESIGN FEATURES41 Gallon High Performance Water HeaterThree Shell Designfor Durability1. Inner polyethylene water reservoir - not alining or sprayed-on coating. Non-metallicand corrosion-proof for long operating life.2. High performance, molded insulation rigid urethane shell. Durable material thatcan not tear or mat. Provides less than11/4 F/hr. standby loss.3. Deep drawn outer steel shell. Pressuretested to 300 psi and rated at 150 lbs.working pressure. Appliance-like finish oftwo step urethane coating.High-capacity, replaceable heat exchangerprovides rapid recovery.Closed Well AquastatQuick action aquastatprovides precise control of temperaturedelivery. Positioned toprovide continuousdraw at peak demandperiods. Closed wellassembly enablesaquastat replacementwithout draining thewater from the tank.Heat Exchanger Pressure Drop6 GPM7 GPM8 GPM10 GPM.81.151.552.65psipsipsipsi5

AMTROL WH-10C SPECIFICATIONSSpecifications and terinchesShippingWeight 823150WH-10C-DW-I80682315011/2”DW denotes double wall heat exchanger. -I denotes optionalinspection opening.WH-10C smooth copper coil with stano guard coated heat exchanger.WH-10C-DW finned copper coil with stano guard coated heat exchanger.System ConnectionsCold WaterInletHot WaterOutletBoilerSupplyBoilerReturn1” NPTM1” NPTM1” NPTM1" NPTMAMTROL WH-10CCommercial Hot Water MakerR Q8.25 TWhere T Differencebetween water inlet andhot water supplytemperaturesR Recovery - GPHQ Boiler Output - BTUH(1) Gallons per hour of domesticwater flow that absorbsboiler heat output atcontinuous flow. (High limitset above boiler water.)(2) The approximatetemperature the boiler waterwill reach when the unitsdeliver the recovery capacity.It is not a recommendedhigh-limit setting, but rather ameasurement of the boilerwater temperature when theheater has reached itssteady-state condition atcontinuous flow.STEADY STATE RECOVERY40 F Water Inlet Temperature120 6Hot Water Supply Temperature140 160 180 BoilerRecovery BoilerRecoveryBoilerRecovery BoilerRecoveryBoilerGPH (R) Output (Q) GPH (R) Output (Q) GPH (R) Output (Q) GPH (R) Output (Q)498329 MBH358295 MBH250248 MBH171198 MBHWaterTemp.(2)200 456301 MBH321265 MBH216214 MBH134155 MBH190 412272 MBH284234 MBH182180 MBH––180 50 F Water Inlet Temperature120 Hot Water Supply Temperature140 160 180 BoilerRecovery BoilerRecoveryBoilerRecovery BoilerRecoveryBoilerGPH (R) Output (Q) GPH (R) Output (Q) GPH (R) Output (Q) GPH (R) Output (Q)549317 MBH383284 MBH240238 MBH165190 MBHWaterTemp.(2)200 500289 MBH343254 MBH207205 MBH138148 MBH190 450260 MBH302224 MBH174172 MBH––180 60 F Water Inlet Temperature120 Based on 15 GPM Boiler Flow.Temperatures in Degrees F,Boiler Outputs in MBH,Recovery Capacities in Gal./Hr.(1)Hot Water Supply Temperature140 160 180 BoilerRecovery BoilerRecoveryBoilerRecovery BoilerRecoveryBoilerGPH (R) Output (Q) GPH (R) Output (Q) GPH (R) Output (Q) GPH (R) Output (Q)614304 MBH412272 MBH230228 MBH157181 MBHWaterTemp.(2)200 557276 MBH367243 MBH197196 MBH141140 MBH190 501248 MBH323213 MBH165163 MBH––180

AMTROL WH-10C SERIES DESIGN FEATURES80 Gallon High Capacity Water HeaterThree Layer Construction forSuperior PerformanceDurable, scratch resistant polyethylene outerjacket.Low density polyurethane insulation. 11/2” thickfor superior heat retention.Stainless steel 316L inner lining.Uniquely designed double wall heat exchangeroffered exclusively by AMTROL. Offers extraprotection to meet local codes.Immersion-type aquastat. No need to drain thetank when replacing aquastat.Single Wall ModelHigh output heatexchanger.Only 1/2 standbyheat loss/hr.Immersion-typeaquastat. No needto drain tank whenreplacing aquastat.Heat Exchanger Pressure DropDouble Wall Model8 GPM1.25 psi10 GPM1.85 psi12 GPM2.2 psi15 GPM2.5 psi7

AMTROL Has Been Producing Quality PlumbingAnd Heating Products For Your Home Since 1946.Other energy efficient, high quality components from your Total Source.AMTROL1 Reverse Osmosis Tank for purified water storage2 Hammertrol for water hammer(knocking pipes) control3 Pressuriser for boosting water pressure4 Therm-X-Trol for thermal expansion absorption5 Hot Water Maker Indirect Water Heater6 Circulator7 Quad Check ValveCorporate Headquarters1400 Division Road, West Warwick, RI 02893401-884-63008Hot Water Maker is a registered trademark of AMTROL Inc. 1998 AMTROL Inc.89101112131415Fast Fill ValveBackflow PreventerRelief ValveTankless CoilExtrol Expansion TankAmerican Air PurgerAmerican Air VentMini-Trol for water hammer controlAMTROL Canada, Ltd.275 Shoemaker Street, Kitchener, Ontario N2E 3B3519-748-1138World Wide Webhttp://www.amtrol.comE-Mail: info@amtrol.comMC#4140 (4/98)

between water inlet and hot water supply temperatures R Recovery - GPH Q Boiler Output - BTUH Q 8.25 T R System Connections Cold Water Hot Water Boiler Boiler Inlet Outlet Supply Return 1" NPTM 1" NPTM 1" NPTM 1" NPTM Specifications and Dimensions Model Capacity Height Diameter Shipping No. gallons inches inches Weight (lbs.) WH .