Designs For All Toric Marking Techniques. Innovation For Best . - ASICO

Transcription

Toric Marking DevicesDesigns for All Toric Marking Techniques. Innovation for Best Toric Outcomes.World’s Widest Selection of Toric Marker for:One Step TechniqueTwo Hand Axis Marking0 -180 Pre-Op Reference MarkingOne Hand Axis Marking

TABLE OF CONTENTSIIIIIIIVVOne Step Toric MarkingTwo Step Toric MarkingIPre-Op Reference MarkersPG.4AE-2930AXsys One Step Electronic Toric MarkingDeviceIIAE-2799TPG.4Neuhann-Nuijts One Step Toric MarkerIIIAE-2929PG.5AXsys 0 -180 Pre-Op Reference ElectronicToric Marking DeviceIVAE-2791TBLPG.5Nuijts-Lane Pre-Op Toric MarkerAE-2793DASICO Pre-Op Toric Reference MarkerAE-2793SASICO Pre-Op Toric Reference Marker,Single SideVIVIIIntra-Op Axis MarkersTwo Hand TechniqueVPG.6Toric Degree GaugeAE-2765NMendez Degree GaugeAE-1595*Ron Yeoh Toric GaugeAE-1590TASICO Beveled Degree Gauge w/ TeethVIAxis MarkerAE-2740NPG.7Nuijts-Solomon Intra-Op Axis Marker“PATIENTS are paying extra for thesepremium Intraocular lenses, andDESERVE NOTHING BUT THE BEST.”Charles Ahn, MDChicago, ILAE-2740HNuijts-Solomon Intra-Op Axis Marker w/Centering PegOne Hand TechniqueVIIAE-2794NPG.7ASICO Intra-Op Axis Markerwww.asico.comAE-2848N*Modi Toric Marker*Specially suggested for small eyes

A NOTE ABOUT TORICTECHNIQUESONE STEP TORIC MARKINGOne step Toric marking makes your steep meridian axis marks pre-operatively. A levelingguide will serve as your 0-180 reference; while the marker/ gauge combo head marks the axisfrom your Toric calculator directly. No marking inside the OR is required.See page 4 for more product details1. Ink the Marking Points2. Align Dial to the Steep Meridian3. Make your Mark(from Toric Calculator)M a rkin gDi rectio nTWO STEP TORIC MARKINGTwo step Toric marking consists of a Pre-Op Reference mark to take intoaccount any cyclotorsional movement, and a steep meridian axis markinside the OR from your Toric calculator.Step 1: Pre– Op Reference MarkingThese marks are done outside of the OR before the surgery. Then identify the 0 , 90 , and 180 on the eyewhile the patient is sitting upright, looking straight ahead. These marks help account for any cyclotorsionalrotation of the eye.See page 5 for more product detailsStep 2: Intra-Op Axis MarkingThese marks are done inside the OR; using the pre-op marks as a reference to proper gauge alignment tomake the steep meridian axis marks to align your toric lens.See pages 6-7 for more product detailsONE HAND AXIS MARKINGTWO HAND AXIS MARKINGA marker and gauge areA marker and gaugebuilt into a single instrumentcombo is used to markto mark the steep merdianthe steep meridian axis.axis.Innovation for Better Outcomes3

AXsys One Step Electronic Toric Marking Device:AE-2930 “AXsysTM is the only device that uses mysense of SIGHT and HEARING to help meeasily and accurately pinpoint the horizontalaxis and stay focused on my patients eye.”ourU n c o v e rTyRUETakayuki Akahoshi, MDJapanTo r i c IOL p o te n t i a lDr. Takayuki Akahoshi is the inventor of AXsysTMCompared to both manual and digital microscope mounted toric marking devicesAXsys has proven to be the most accurate and reliable device available.Toric Marking SystemManual MarkingMethodsBubble LevelMarkerDigital Toric MarkingSystemsDeviation from Intended Axis 5.0 4.1 1.8 *Nuijts R.1Kakulidis C.2H. Burkhard Dick3AXsysTM ToricMarker1.25 Kakulidis C.2The AXsysTM toric marking device is the only device that offers both audio and visual confirmation ofthe correct position to make an accurate toric mark, so you never have to divert focus from thepatients eye.GREEN & No BeepingPerfect Horizontal AxisORANGE & Moderate BeepingSlight Tilt (Right/Left Reading)Neuhann– Nuijts One Step Toric Marker:AE-2799TRED & Fast BeepingExtreme Tilt (Right/Left Reading)EXCLUSIVEDESIGN Designed for simple and accurate one step Toric marking, eliminating the need for any marks inside the OR Bubble level is sensitive to 0.5 to confirm correct axis while marking, and is easily removable for steralization 12.5mm outer diameter sutible for all eyes; including those with small orbits Clinical study of 50 patients shows no alignment errors over 5 , meaning AN ACCURATE AND CONSISTENT TORIC MARK4www.asico.com

PRE-OP REFERENCE MARKERSTwo Step TechniqueAXsys 0 -180 Pre-op Reference Electronic Toric Marking Device:AE-2929 Make 0 -180 pre-op reference marks to make an accurate reference to the intra-op marks AXsys Electronic Toric Head has adjustable sensitivity levels that can be set to be as sensitive as 0.2 Same AXsys Electronic Head as the one step model (AE-2930), which has tested to be world’s most accurate Toric marking deviceNuijts– Solomon Pre– Op Toric Marker:AE-2791TBLM arking points on bothEXCLUSIVEDESIGNsides to work with rightand left eye Used temporally on to make 0 , 90 , and 180 reference marks on right and left eyes Bubble level is sensitive to 0.5 to confirm horizontal axis and ensure an accuratepre– op reference mark Bubble level easily removable for sterilizationM arking points on bothASICO Pre-op Toric Marker:AE-2793DC urvature of markingsides to work with rightand left eyepoints confirm to corneaN on marking surface minimizedto maximize visibility Used temporally on to make 0 , 90 , and 180 reference marks on right and left eyesASICO Pre-op Toric Marker, Single Side:AE-2793SN on marking surface minimizedto maximize visibilityC urvature of markingpoints confirm to cornea Used straight on to make 0 , 90 , and 180 reference marks on right and left eyesInnovation for Better Outcomes5

TORIC GAUGESTwo Step TechniqueFOR THE TWO HAND AXIS MARKING TECHNIQUERon Yeoh Toric Gauge:AE-1595C utouts at 0 , 90 ,180 , and 270 allow easyvisualization of horizontal or vertical referenceEXCLUSIVEDESIGN Inner diameter: 12mm, Outer Diameter: 14mm makes this gauge the thinnest gauge on the market Marking points every 5 YEOH GAUGEW itness theSTANDARD GAUGE12mm inner diameter12mm inner diameter14mm outer diameter16mm outer diameterDI F F E R E NC EIdeal for Small OrbitsASICO Beveled Degree Gauge w/ Teeth:AE-1590TB eveled design reducesmicroscope glareF ixation Teeth Inner diameter: 12mm Outer Diameter: 16mm Marking points every 5 Beveled design reduces microscope glare; also allows numbers to sit as close to the cornea as possibleMendez Degree Gauge:AE-2765NAlso available without fixation teeth(AE-1589)6 Inner diameter: 12mm, Outer Diameter: 16mm Marking points every 10 Note: All ASICO Toric Gauges Markers are compatiblewith any two hand intra op axis marker (AE-2740N andAE-2740H listed on p. 7), and can be used with anypre-op reference marker

hINTRA-OP AXIS MARKERSTwo Step TechniqueTWO HAND AXIS MARKING TECHNIQUENuijts-Solomon Toric Axis Marker:AE-2740NL aser lines on top of markingpoints allow to center marksEXCLUSIVEDESIGN5 mm non marking optic zone forvisibilityEXCLUSIVEDESIGNAlso available with centering peg to center tomyopic pupil (AE-2740H)Fits precisely within all Toric gauges listed on page 6 (AE-1595, AE-1590T, AE-1589, AE-2765N)ONE HAND INTRA-OP AXIS MARKERSAn alternative to using both a gauge and marker for axis marking in thetwo step techniqueASICO Intra-Op Toric Axis Marker II:AE-2794NYeoh Toric Manipulator:EXCLUSIVEDESIGNAE-2557 Marker and gauge combo allow Intra-Op Axis marking with one hand Marking points every 5 degrees OD: 13.5mmC utouts at 0 and 180 allowto align to pre-op referencemarksEXCLUSIVEDESIGNN otch on top to align to properToric reading5 mm non marking opticzone for better visibilityK nurled outer barrel to alignModi Low Profile Intra-Op Toric Axis Marker:marking points to Toric calculatorreadingAE-2848N Marker and gauge combo allow Intra-Op Axis marking with one hand. Marking points every 5 degrees 12.5MM OD Ideal for Small OrbitsEXCLUSIVEDESIGN5 mm non markingoptic zone for visibilityInnovation for Better Outcomes7

Toric Markers Reference GuideTwo Step TechniqueOne Step TechniqueIntra– Op Axis MarkingPre-Op ReferenceMarkingTwo Hand– GaugeTwo Hand– MarkerOne E-2793SAE-1589Available from your local distributorASICO LLC26 Plaza DriveWestmont, IL USA 60559Ph. 1 630-986-8032Fax. 1 630-986-0065email: info@asico.comwww.asico.comBR548-13

One step Toric marking makes your steep meridian axis marks pre-operatively. A leveling guide will serve as your 0-180 reference; while the marker/ gauge combo head marks the axis from your Toric calculator directly. No marking inside the OR is required. TWO STEP TORIC MARKING Two step Toric marking consists of a Pre-Op Reference mark to take into