PRODUCT SPECIFICATIONST– SERIES REVERSE OSMOSIS SYSTEMSAXEON AT– Series Reverse Osmosis Systems set theindustry standard with a compact, space saving designwith high quality components. These systems are availablein capacities of 500 and 1,000 gallons per day and feature4.5" diameter sediment and carbon block pre-filters, lowenergy membranes, a high pressure pump and a solenoidvalve all mounted onto a corrosion-resistant, powdercoated aluminum frame.AXEON AT– Series Reverse Osmosis Systems can alsobe upgraded for higher recovery rates by adding theconcentrate recycle option.AT –1000Reverse Osmosis SystemBENEFITS Fully Equipped and Customizable Lightweight Design Compact Space Saving Design Components Easily Accessible Pre-Plumbed, Wired and Assembled Factory Tested and Preserved Low Operation and Maintenance Costs Easy Maintenance and Servicing 1-Year Limited WarrantyAT –1000 (Front)Reverse Osmosis System

FEATURESOPTIONS Manual On and Off Control Switch AXEON HF4 – Series Extra LowEnergy Membrane Elements White Powder Coated Aluminum Frame AXEON HF5 – Series Ultra LowEnergy Membrane Elements AXEON 5-Micron Sediment Pre-Filter AXEON 10-Micron Carbon Block Pre-Filter AXEON by Pentek Single O-RingFilter Housings Fluid-O-Tech Low Lead Brass RotaryVane High Pressure Pump AXEON NF3 – Series NanofiltrationMembrane Elements AXEON NF4 – Series NanofiltrationMembrane Elements AXEON SS – Series Membrane Housings ODP High Efficiency Carbonator Motor AXEON FRP– Series Membrane Housings AXEON HF1– Series Low EnergyMembrane Elements Concentrate Recycle Valve with Flow Meter AXEON PVC –Series Membrane Housings HM Digital PSC –150 TDS/Conductivity Controller Fluid-O-Tech Stainless Steel RotaryVane Pump AXEON Permeate Flow Meter AXEON Concentrate Flow Meter Minitrol Computer Controller Feed Low Pressure Switch 15 - 30 psi AXEON Composite Feed Solenoid Valve AXEON 316L SS – Series Concentrate Valve Minitrol IF Computer Controller withFeed Flush AXEON 0 - 300 psi Pump Pressure Gauge S –150 Computer Controller withFeed Flush AXEON 0 -100 psi Pre-Filter Pressure Gauges High Pressure Tank Switch Push/Pull Fittings with Locking Safety Clips Chemical Pump Outlet Blending Valve Permeate Flush with Pressure Tank Permeate Flush with Atmospheric Tank Permeate Flush with Mechanical Float Permeate Sample Ports Wooden Shipping CrateAT–1000 (Back)Reverse Osmosis System

SPECIFICATIONSMODELSAT– 500AT –1000DesignConfigurationSingle PassSingle PassFeedwater Source (ppm)ATDS 2000TDS 2000Standard Recovery Rate %Recovery with Concentrate Recycle %2641Up to 75Up to 75Rejection and Flow RatesBNominal Salt Rejection %Permeate Flow (gpm / lpm)99990.35 / 1.320.69 / 2.61Minimum Feed Flow (gpm / lpm)1.35 / 5.111.69 / 6.40Maximum Feed Flow (gpm / lpm)3.00 / 11.364.00 / 15.14Minimum Concentrate Flow (gpm / lpm)1.00 / 3.781.00 / 3.78Feed Connection (in)1 FNPT1 FNPTPermeate Connection (in)3/8 QC3/8 QCConcentrate Connection (in)3/8 QC3/8 QCConnectionsMembranesMembranes Per Vessel11Membrane Quantity23252125211:11:1:123Rotary Vane 401 BrassRotary Vane 601 BrassMembrane SizeVesselsVessel ArrayVessel QuantityPumpsPump TypeMotor HP1/31/21725 (1465)1725 (1465)Standard Voltage Amp Draw110V, 60Hz, 1PH, 6.6AC110V, 60Hz, 1PH, 8.2ACHigh Voltage Service Amp Draw220V, 60Hz, 1PH, 3.2AC220V, 50Hz, 1PH, 3.7AC220V, 60Hz, 1PH, 3.9AC220V, 50Hz, 1PH, 4.1AC14 x 20 x 27 / 36 x 51 x 6914 x 20 x 27 / 36 x 51 x 6965 / 29.570 / 31.75RPM @ 60Hz (50 Hz)System ElectricalSystem DimensionsApproximate Dimensions D L x W x H (in / cm)Approximate Weight (lbs / kg)Test Parameters: 550 TDS Filtered (5–Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 150 psi / 10.34 bar Operating Pressure, 77 F / 25 C, Recovery as stated, 7.0 pH.Data taken after 60 minutes of operation.Note: All 50Hz systems come standard with AXEON HF4 –Series Extra Low Energy Membrane Elements.A. Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individualapplications which do not meet or exceed minimum and maximum operating limits for such conditions.B. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow.C. Varies with motor manufacturer.D. Does not include operating space requirements.OPERATING LIMITS EMaximum Feed Temperature ( F / C)Minimum Feed Temperature ( F / C)85 / 2940 / 4Maximum Ambient Temperature ( F / C)120 / 49Minimum Ambient Temperature ( F / C)40 / 4Maximum Feed Pressure (psi / bar)Minimum Feed Pressure (psi / bar)Maximum Turbidity (NTU)Maximum Free Chlorine (ppm)Maximum TDS (ppm)102000Maximum Hardness (gpg)085 / 6Maximum pH (Continuous)1145 / 3Minimum pH (Continuous)2Maximum Operating Pressure (psi / bar)150 / 10Maximum pH (cleaning 30 minutes)13Maximum Feed Silt Density Index (SDI) 3Minimum pH (cleaning 30 minutes)1E. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature.

AXEON BT–Series Reverse Osmosis Systems furtherexpand the AXEON commercial reverse osmosis lineup withthree models designed for 1,500, 1,800 and 2,000 gallonsper day. Featuring 4.0" diameter sediment and carbon blockpre-filters, low energy membranes and a high pressurepump, the BT–Series sets the industry standard for highperformance reverse osmosis systems. These models canalso be upgraded with options for higher recovery rates byadding the concentrate recycle option.BT – 2000 (Back)Reverse Osmosis SystemBT – 2000Reverse Osmosis SystemBENEFITS Fully Equipped and Customizable Expandable and Lightweight Design Compact Space Saving Design Components Easily Accessible Pre-Plumbed, Wired and Assembled Factory Tested and Preserved Low Operation and Maintenance Costs Easy Maintenance and Servicing 1-Year Limited Warranty

FEATURESOPTIONS Manual On and Off Control Switch AXEON HF4 – Series ExtraLow Energy Membrane Elements White Powder Coated Aluminum Frame AXEON 5-Micron Sediment Pre-Filter AXEON 10-Micron Carbon Block Pre-Filter AXEON by Pentek Single O-RingFilter Housings Fluid-O-Tech Low Lead Brass RotaryVane High Pressure Pump AXEON HF5 – Series UltraLow Energy Membrane Elements AXEON NF3 – Series NanofiltrationMembrane Elements AXEON NF4 – Series NanofiltrationMembrane Elements AXEON SS – Series Membrane Housings ODP High Efficiency Carbonator Motor AXEON FRP– Series Membrane Housings AXEON HF1– Series Low EnergyMembrane Elements Concentrate Recycle Valve with Flow Meter AXEON PVC –Series Membrane Housings AXEON Permeate Flow Meter AXEON Concentrate Flow Meter Feed Low Pressure Switch 15 - 30 psi AXEON Composite Feed Solenoid Valve AXEON 316L Stainless Steel Concentrate Valve HM Digital PSC –150 TDS/Conductivity Controller Fluid-O-Tech Stainless Steel RotaryVane Pump Minitrol Computer Controller Minitrol IF Computer Controller withFeed Flush AXEON 0 - 300 psi Pump Pressure Gauge S –150 Computer Controller withFeed Flush AXEON 0 -100 psi Pre-Filter Pressure Gauges High Pressure Tank Switch John Guest Push/Pull Fittingswith Locking Safety Clips Chemical Pump Outlet Blending Valve Permeate Flush with Pressure Tank Permeate Flush with Atmospheric Tank Permeate Flush with Mechanical Float Permeate Sample Ports Wooden Shipping CrateBT – 2000 (Front)Reverse Osmosis System

SPECIFICATIONSMODELSBT–1500BT –1800BT – 2000DesignConfigurationSingle PassSingle PassSingle PassFeedwater Source (ppm)ATDS 2000TDS 2000TDS 2000Standard Recovery Rate %Recovery with Concentrate Recycle %413063Up to 75Up to 75Up to 75Rejection and Flow RatesBNominal Salt Rejection %Permeate Flow (gpm / lpm)9999991.04 / 3.931.25 / 4.731.38 / 5.22Minimum Feed Flow (gpm / lpm)2.04 / 7.724.25 / 16.102.35 / 8.89Maximum Feed Flow (gpm / lpm)3.00 / 22.706.00 / 22.716.00 / 22.701.00 / 3.783.00 / 11.361.00 / 3.781 FNPTMinimum Concentrate Flow (gpm / lpm)ConnectionsFeed Connection (in)1 FNPT1 FNPTPermeate Connection (in)3/8 QC3/8 QC3/8 QCConcentrate Connection (in)3/8 QC3/8 QC3/8 QCMembranesMembranes Per Vessel111Membrane Quantity2132540404025401:111:1:1213Rotary Vane 601 BrassRotary Vane 1001 BrassRotary Vane 1001 Brass3/43/43/41725 (1465)1725 (1465)1725 (1465)Membrane SizeVesselsVessel ArrayVessel QuantityPumpsPump TypeMotor HPRPM @ 60Hz (50 Hz)System ElectricalStandard Voltage Amp Draw110V, 60Hz, 1PH, 11.0AC110V, 60Hz, 1PH, 11.0AC110V, 60Hz, 1PH, 11.0ACHigh Voltage Service Amp Draw220V, 60Hz, 1PH, 5.6A220V, 50Hz, 1PH, 5.6AC220V, 60Hz, 1PH, 5.6A220V, 50Hz, 1PH, 6.6AC220V, 60Hz, 1PH, 5.6AC220V, 50Hz, 1PH, 6.6AC19 x 23 x 46 / 48 x 58 x 11619 x 23 x 46 / 48 x 58 x 11619 x 23 x 46 / 48 x 58 x 116105 / 47.63105 / 47.63115 / 52.16CCSystem DimensionsApproximate Dimensions D L x W x H (in / cm)Approximate Weight (lbs / kg)Test Parameters: 550 TDS Filtered (5–Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 150 psi / 10.34 bar Operating Pressure, 77 F / 25 C, Recovery as stated, 7.0 pH.Data taken after 60 minutes of operation.Note: All 50Hz systems come standard with AXEON HF4 –Series Extra Low Energy Membrane Elements.Note 2: BT–1800 Reverse Osmosis Systems come standard with the Concentrate Recycle Valve and Flow Meter options in order to achieve a higher recovery rate.A. Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individualapplications which do not meet or exceed minimum and maximum operating limits for such conditions.B. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow.C. Varies with motor manufacturer.D. Does not include operating space requirements.OPERATING LIMITS EMaximum Feed Temperature ( F / C)Minimum Feed Temperature ( F / C)85 / 2940 / 4Maximum Ambient Temperature ( F / C)120 / 49Minimum Ambient Temperature ( F / C)40 / 4Maximum Feed Pressure (psi / bar)Minimum Feed Pressure (psi / bar)Maximum Turbidity (NTU)Maximum Free Chlorine (ppm)Maximum TDS (ppm)102000Maximum Hardness (gpg)085 / 6Maximum pH (Continuous)1145 / 3Minimum pH (Continuous)2Maximum Operating Pressure (psi / bar)150 / 10Maximum pH (cleaning 30 minutes)13Maximum Feed Silt Density Index (SDI) 3Minimum pH (cleaning 30 minutes)1E. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature.

AXEON CT–Series Reverse Osmosis Systems aredesigned for high performance and are equipped withmany standard features in a cost-efficient, compact design.AXEON CT–Series Reverse Osmosis Systems have beenengineered for capacities ranging from 4,000 to 7,000gallons per day. These models include a microprocessorcontroller with low-pressure monitoring and alarm, pretreatment lockout, and tank level input. A TDS monitor,multi-stage booster pump, low energy membranes andthree pre-filters are all part of the standard features.Upgrades such as feed flush and a concentrate recycleloop to increase recovery rates are also available.CT – 7000 (Back)Reverse Osmosis SystemCT – 7000Reverse Osmosis SystemBENEFITS Fully Equipped and Customizable Compact Space Saving Design Components Easily Accessible Pre-Plumbed, Wired and Assembled Factory Tested and Preserved Low Operation and Maintenance Costs Easy Maintenance and Servicing 1-Year Limited Warranty

FEATURESOPTIONS Minitrol Computer Controller AXEON HF4 – Series Extra Low EnergyMembrane Elements Multi Color LED Indicator Status Light Pre–Treatment Lockout Tank Level Input Low Pressure Monitoring and Alarm White Powder Coated Aluminum Frame AXEON 5-Micron Sediment Pre-Filter AXEON 10-Micron Carbon Block Pre-Filter AXEON 1-Micron Sediment Pre-Filter AXEON by Pentek Single O-RingFilter Housings Goulds Multi–Stage Booster Pump AXEON HF1– Series Low EnergyMembrane Elements AXEON PVC –Series Membrane Housings AXEON Permeate Flow Meter HM Digital PSC –150 TDS/Conductivity Controller AXEON HF5 – Series Ultra Low EnergyMembrane Elements AXEON NF3 – Series NanofiltrationMembrane Elements AXEON NF4 – Series NanofiltrationMembrane Elements AXEON SS – Series Membrane Housings AXEON FRP– Series Membrane Housings Concentrate Recycle Valve with Flow Meter Goulds Multi-Stage Stainless SteelBooster Pump Minitrol IF Computer Controller withFeed Flush S –150 Computer Controller withFeed Flush and Dual TDS S –150 Computer ControllerExpander Board Pump Pressure Relief Valve AXEON Concentrate Flow Meter High Pressure Tank Switch Feed Low Pressure Switch 15 - 30 psi Chemical Pump Outlet AXEON Composite Feed Solenoid Valve Blending Valve AXEON 316L Stainless Steel Concentrate Valve Permeate Sample Ports AXEON 0 - 300 psi Pump Pressure Gauge Single Wooden Shipping Crate AXEON 0 - 300 psi Concentrate Pressure Gauge Double Wooden Shipping Crate AXEON 0 -100 psi Pre-Filter Pressure Gauges John Guest Push/Pull Fittings with LockingSafety ClipsCT – 7000 (Front)Reverse Osmosis System

SPECIFICATIONSMODELSCT– 4000CT– 5000CT– 7000DesignConfigurationSingle PassSingle PassSingle PassFeedwater Source (ppm)ATDS 2000TDS 2000TDS 2000Standard Recovery Rate %Recovery with Concentrate Recycle %485362Up to 75Up to 75Up to 75Rejection and Flow RatesBNominal Salt Rejection %Permeate Flow (gpm / lpm)9999992.78 / 10.523.47 / 13.144.86 / 18.40Minimum Feed Flow (gpm / lpm)5.78 / 21.006.47 / 24.507.86 / 29.80Maximum Feed Flow (gpm / lpm)14.00 / 53.0014.00 / 53.0014.00 / 53.003.00 / 11.363.00 / 11.363.00 / 11.36Minimum Concentrate Flow (gpm / lpm)ConnectionsFeed Connection (in)1 FNPT1 FNPT1 FNPTPermeate Connection (in)1 FNPT1 FNPT1 FNPTConcentrate Connection (in)1 FNPT1 FNPT1 FNPTMembranesMembranes Per Vessel111Membrane geMulti-StageMulti-Stage1.51.51.53450 (2900)3450 (2900)3450 (2900)Membrane SizeVesselsVessel ArrayVessel QuantityPumpsPump TypeMotor HPRPM @ 60Hz (50 Hz)System ElectricalStandard Voltage Amp Draw220V, 60Hz, 1PH, 8.3AC220V, 60Hz, 1PH, 8.3AC220V, 60Hz, 1PH, 8.3ACHigh Voltage Service Amp Draw220V, 50Hz, 1PH, 8.9A220V, 60Hz, 3PH, 5.1AC220V, 50Hz, 3PH, 6.1AC380V, 50Hz, 3PH, 4.5AC460V, 60Hz, 3PH, 3.5AC220V, 50Hz, 1PH, 8.9A220V, 60Hz, 3PH, 5.1AC220V, 50Hz, 3PH, 6.1AC380V, 50Hz, 3PH, 4.5AC460V, 60Hz, 3PH, 3.5AC220V, 50Hz, 1PH, 8.9AC220V, 60Hz, 3PH, 5.1AC220V, 50Hz, 3PH, 6.1AC380V, 50Hz, 3PH, 4.5AC460V, 60Hz, 3PH, 3.5AC30 x 38 x 47 / 76 x 96 x 11930 x 38 x 47 / 76 x 96 x 11930 x 38 x 47 / 76 x 96 x 119235 / 106.60250 / 113.40265 / 120.20CCSystem DimensionsApproximate Dimensions D L x W x H (in / cm)Approximate Weight (lbs / kg)Test Parameters: 550 TDS Filtered (5–Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 150 psi / 10.34 bar Operating Pressure, 77 F / 25 C, Recovery as stated, 7.0 pH.Data taken after 60 minutes of operation.Note: All 50Hz systems come standard with AXEON HF4 –Series Extra Low Energy Membrane Elements.A. Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individualapplications which do not meet or exceed minimum and maximum operating limits for such conditions.B. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow.C. Varies with motor manufacturer.D. Does not include operating space requirements.OPERATING LIMITS EMaximum Feed Temperature ( F / C)85 / 29Maximum Turbidity (NTU)1Minimum Feed Temperature ( F / C)40 / 4Maximum Free Chlorine (ppm)0Maximum Ambient Temperature ( F / C)120 / 49Minimum Ambient Temperature ( F / C)40 / 4Maximum Hardness (gpg)0Maximum Feed Pressure (psi / bar)85 / 6Maximum pH (Continuous)11Minimum Feed Pressure (psi / bar)45 / 3Maximum TDS (ppm)2000Minimum pH (Continuous)2Maximum Operating Pressure (psi / bar)150 / 10Maximum pH (cleaning 30 minutes)13Maximum Feed Silt Density Index (SDI) 3Minimum pH (cleaning 30 minutes)1E. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature.800-320-4074MKT – 672 – A07/21/21AXEONwater.com 2021 AXEON Water Technologies

AXEON BT-Series Reverse Osmosis Systems further expand the AXEON commercial reverse osmosis lineup with three models designed for 1,500, 1,800 and 2,000 gallons per day. Featuring 4.0" diameter sediment and carbon block pre-filters, low energy membranes and a high pressure pump, the BT-Series sets the industry standard for high-