Ameren Service AreaProduct CatalogMilbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com

2MILBANKOVERVIEWMilbank OverviewEnergy At Work since 1927Milbank designs and manufactures electrical solutions that move and manage power for the residential,commercial, industrial, utility and transportation sectors. With more than 90 years of expertise in electricalengineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures andenclosed controls. Founded in 1927, Milbank is a family-owned, American manufacturer headquartered in KansasCity, Mo. For more information, please visit milbankworks.com.METERINGAs a market leader in electrical metering equipment, Milbankhas set the standard for quality since 1927. Hundreds ofconfigurations are available, including many sizes, knockoutconfigurations, Terminals configurations, bypass options,hubs, locks and connectors. Milbank has the socket youneed with thousands of active products to meet your utility’srequirements.ENCLOSURESMilbank’s line of enclosures include commercial junction boxes,panel mount enclosures, transformer cabinets, wireway andtroughs. Built with high-quality craftsmanship and materialswhich meet or exceed industry standards, Milbank enclosuresare made to protect controls and equipment from dust,dirt and other harmful elements found in a wide variety ofenvironments based on various NEMA ratings Milbank offers.ENCLOSED CONTROLSMilbank doesn’t just build empty enclosures. We can deliverthe entire package, complete with custom control equipmentbuilt to your exact specifications by our engineers. Milbankenclosed controls are an attractive, secure, easy-to-install andcost-effective solution when underground remote site powerdistribution and control equipment is required, replacingunsightly and inefficient strut and backboard structures.Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specificationsand features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com

Table of Contents3TABLE OFCONTENTSAir Conditioner Disconnects30-60 Amps AC disconnects. 660 Amps AC disconnect with 20 Amps GFCI receptacle . 7Hot tub disconnects . 8Single Position Sockets125-200 Amps, 5 & 7 terminal, heavy duty lever bypass, ringless. 9320 Amps, 5 & 7 terminals, heavy duty lever bypass, ringless. 10Unmetered Load Center100-200 Amps, load center with main breaker. 11Meter Mains100-200 Amps, 5 terminals, heavy duty lever bypass, ringless. 12100-200 Amps, 5 terminals, heavy duty lever bypass, with load center, ringless. 13Manual transfer switch, 200 Amps, 5 terminals, heavy duty lever bypass, with aux provision, ringless. 14200 Amps, 7 terminals, heavy duty lever bypass, ringless. 15320 Amps, 5 terminals, heavy duty lever bypass, ringless. 16400 Amps, 5 & 7 terminals.17Multi-Position200 Amps, 5 terminals, heavy duty lever bypass, ringless. 18200 Amps, 7 terminals, heavy duty lever bypass, ringless. 19Multi-Position Meter Mains200 Amps, 5 terminals, heavy duty lever bypass, with breaker provisions, ringless. 20200 Amps, 5 terminals, heavy duty lever bypass, with breaker provisions, horizontal, ringless . 21-22Transformer Rated20 Amps, 8 & 13 terminals, heavy duty lever bypass, prewired, ringless . 23400-800 Amps transformer cabinets, PT cabinets . 24CT mounting racks, CT cabinets . 25-26Bussed CT. 27-32Termination boxes. 33-35Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specificationsand features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com

4Table of ContentsTABLE OFCONTENTSPedestals100-200 Amps, 5 terminals, heavy duty lever bypass, with meter main and load center. 36Temporary Power Units125 Amps, 4 terminals, ringless . 37Surface & Pedestal Mount Power Outlets125 Amps, surface mount . 38125 Amps, pedestal mount . 39Power outlet accessories. 40-45MiscellaneousPad-mounted panelboard. 46Terminal boxes. 47Tap box.48Enclosed controls . 49-57Circuit breakers . 58-59Accessories. 60-62NEMA commercial enclosures . 63Reference information. 64-69Index . 70-72Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specificationsand features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com

5Catalog Number LogicCATALOGNUMBERLOGICHow our product catalog numbers are derivedMilbankdrawingnumberTG: Triplex groundQG: Quadplex groundLugs (1Ø or 3Ø,350 or 600 kcmilSingle: K1, K3, K5, K7Twin: K2, K4, K6, ARE5th terminal designation5T6: installed at 6:005T9: installed at 9:00U: UL ListedS: Non-UL ListedUAP: UL, aluminum,paintedBLG: Barrel lock /guard provisionHub Openings & Closing Plates-O-RL-R-XL-XT-XTL-X-RXLU: UL ListedS: Non-UL ListedUAP: UL, aluminum,paintedBlank topSmall hub openingLarge hub openingSmall closing plate(2) Large Closking plates(2) Small closking platesLarge closing plateLarge hub openingadapted to smallclosing plate-RRL Large hub openingadapted to small hubopening-PXL Closing platepacked inside-WL 1” hub-YL 1¼” hub-ZL 1½” hub-DL 2” hub-EL 2½” hub-F3” hub-G3½” hub-H4” hubKK: Horn bypassBL: Barrel G: Triplex groundQG: Quadplex ground5th terminal designation5T6: installed at 6:005T9: installed at 9:00Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specificationsand features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.comUtilityspecificdesignation

6Air Conditioner DisconnectsACDISCONNECTS30-60 AmpsU3802U3812U3832Milbank’s air conditioner disconnect has a removable hinged cover that makes wiring a breeze. Our compact design meetsNEC wiring space requirements and also complies with NEC article 440-14. For safe working conditions, our disconnectpullers may be removed and reinstalled in the OFF position. Additionally, padlock provisions are included on the front cover.As with other Milbank products, our enclosure is constructed of G90U galvanized steel and electrostatically finished with anattractive, light gray, baked powder coating. Our epoxy/polyester resin blend offers a finish that is both durable and faderesistant.30-60 Amps Air Conditioner Disconnects 1Ø 240 VACCatalogNumberAmpsU3802Line/Load WireRangeGround WireRange CU/ALDimensionsWire RatingTypeMaxH.P.Weight(lbs.)CUALD"W"H"CU CAL C60Non-Fusible103.25#14-#2#12-#2#14-421 2571 260 /75 60 /75 U381260Non-Auto103.25#14-#2#12-#2#14-421 2571 260 /75 60 /75 U383230Fusible32.5#14-#3#14-#3#14-312 85760 /75 60 U386260Fusible103.3#14-#3#14-#3#14-32 85960 /75 60 /75 1Notes UL listed as Enclosed Pullout Switch NEMA 3R Weather resistant 1-inch concentric knockoutsPlease consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications andfeatures shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com

7Air Conditioner DisconnectsACDISCONNECTS60 Amps With 20 Amps GFCI ReceptacleU3822-20GWRSpecifications 1-inch concentric knockouts 1Ø, 240 VAC 60 Amps, non-fused 20 Amps GFCI receptacle Reset/test button Weather resistant Meets NEC #406.8 requirements Meets NEC #210.63 requirements UL listed as Power Outlet NEMA 3R In-use cover* Duplex ground connector60 Amps Air Conditioner Disconnect with 20 Amps GFCI Receptacle 1Ø, 240 VACCatalog )106Line/Load WireRangeCUAL#14-#2#12-#2Ground WireRange CU/AL#14-4DimensionsWire RatingD"W"H"CU CAL C44 551 472 560 /75 60 /75 Notes Disconnect Pullers: To ensure the safest conditions, Milbank disconnect pullers are reversible so they may bereinstalled in the OFF position. Padlock Provision: All units are designed with a padlock provision on the cover for security.*Rated as an in-use cover (cover may be closed with cords plugged into receptacle).Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specificationsand features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com

8Hot Tub DisconnectHOT TUBDISCONNECTNEMA 3R EnclosuresU4881-O-50GBU4881-O-60GBSpecifications 240 VAC ground fault protection UL listed NEMA 3R Weather resistant 2-pole, 50 Amps GFCI breaker protection Compact size Three or four wire installation 1Ø, 120/240 VAC Standard package of 12 Two extra 1-pole breaker spaces 100 Amps overall rating Easy to installHot Tub Disconnect or Sub Panel Breaker Enclosure NEMA 3RCatalog NumberAmpsTypeWeight(lbs.)Line/Load WireRangeCUALGround WireRange CU/ALDimensionsD"W"H"31U4881-O—Breaker Provision7#14-1/0#14-1/0#14-1/03 47 281 2U4881-O-50GB50Breaker8#14-1/0#14-1/0#14-1/033 471 281 2U4881-O-60GB60Breaker8#14-1/0#14-1/0#14-1/03 47 281 231Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications andfeatures shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com

9Single Position Heavy Duty Lever Bypass125-200 AMPSSINGLEPOSITIONLEVER BYPASS125-200 Amps 5 & 7 Terminals Ringless 600 19701U9551-RXL-QG-AMSU9701-RXL-QG-AMSNOTEAmeren requires these units at 240 VAC and below.125 Amps 5 Terminals Single Position Heavy Duty Lever Bypass Ringless 1Ø3W OH OnlyCatalog Connectors CU/ALLineLoadH.O.#6-350#6-35011 r74 81018 2Lever47 810181 2134312 23 41 4,1 2321 23 41 4,1 2200 Amps 5 Terminals Single Position Heavy Duty Lever Bypass Ringless 1Ø3W or 3Ø3WCatalog Connectors SP* "W"H"12Lever74 81018 2#6-350Lever47 810#6-350#6-350Lever47 6-3503312 23181 2321 231319321 214 81319312 21Lever74 81319312 21Lever47 81319321 2114 41 4,1 2 41 4,1 2 4,1 21 41 4, 21 41 4, 21 4 4,1 21 4200 Amps 7 Terminals Single Position Heavy Duty Lever Bypass Ringless 3Ø4WConnectors CU/ALBypassDimensionsKnockoutsCatalog H.O.#6-350#6-350Lever47 810181 2321 2U9701-RXL-QG-AMSOH/UGC.P.#6-350#6-350Lever47 81319321 23 431 4,1 241 4,1 21 4Notes Hubs: For proper hub selection, see the hub suffix chart on the accessories page. Connectors: Extruded aluminum connectors are tin plated. U9550, U9551 and U6193 units include removable bondingstrap for isolated neutral. For U9701, add K1047 isolated neutral kit. Bypass: Lever supplies clamping action and also operates bypass device.*UL listed, painted aluminumPlease consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specificationsand features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com

10320 AMPSSINGLE POSITIONLEVER BYPASSSingle Position Heavy Duty Lever Bypass320 Amps 5 & 7 Terminals Ringless 600 VAC1111311436321 1 14 6-AMS12131574011211149113 6-AMSU4911-X-QG-BL-AMSNOTEAmeren requires these units at 240 VAC and below.320 Amps 5 Terminals Single Position Heavy Duty Lever Bypass Ringless 1Ø3WCatalog X-QG-K3-K2-5T6-AMS*U5740-X-K3L-K2L-5T6-AMS* OH/UGU5786-X-K3-K2-5T6-BL-AMS OH/UGC.P.C.P.C.P.C.P.Connectors CU/ALLineLoad#4-600 or(2) #1/0-250#4-600 or(2) #1/0-250#4-600 or(2) #1/0-250#4-600 or(2) #1/0-250Twin #350Twin #350BypassDimensionsKnockoutsD"W"H"1Lever74 81328 43Lever47 813383 43Twin #350Lever74 81531 43Twin #350Lever61 2173 4383 431321 4, 2121 2 4, 211 4134 4—11 4,1 2 411 4———320 Amps 7 Terminals Single Position Heavy Duty Lever Bypass Ringless 3Ø4WCatalog NumberConnectors CU/ALService HubU4911-X-QG-BL-AMS†OH/UGC.P.LineLoad 8" x 16 Studs 3 8” x 16 Studs3BypassLeverDimensionsKnockoutsD"W"H"123461 2173 4383 44311 4Notes* For 3Ø3W, remove bonding strap on U1079. For the U5740, use K5979 isolated neutral kit.† Studs will need lug kit on line/load. See page 61 for connector kits.Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications andfeatures shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com

11Unmetered Load CentersUNMETEREDLOAD CENTERS100-200 Amps 120/240 VAC221453 459713 4U5971-XL-200100-200 Amps Load Center with Main Breaker 120/240 VACCatalog NumberMain nockoutsD"W"H"123C.P.14 214 825 16312 211OH/UGC.P.41 2141 8251 16321 211OH/UGC.P.41 2141 8251 16321 21111453 2, 41 4,1 2 2,3 41 4,1 2 2,3 41 4,1 2Notes AIC Rating: 22K AIC rating. Line Terminals: As specified on circuit breaker (300 kcmil max). Load Terminals: As specified on circuit breakers (#1 AWG max). Breaker Interlock: Order K5815 for 200 Amps or 150 Amps to 100 Amps breakers (large frame to small frame). OrderK5820 for 200 Amps or 150 Amps to 200 Amps or 150 Amps breakers (large frame to large frame). Order K5830 for 100Amps to 100 Amps breakers (small frame to small frame).Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specificationsand features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com

12100-200AMPSMETER MAINSMeter Mains100-200 Amps 5 Terminals Lever Bypass Ringless20/240 VAC221142137913U3791N-RXL-200-5T9-AMS100-200 Amps 5 Terminals Meter Mains Heavy Duty Lever Bypass Ringless 1Ø3W OH OnlyCatalog 91N-RXL-200-5T9-AMS200OHConnectors CU/ALDimensionsKnockoutsLineLoadD"W" H"12C.P.#6-350C.B.274 321334C.P.#6-350C.B.427 321334345 21 4— 21 4—312 21321 21Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications andfeatures shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com

13Meter Mains With Load Center100-200 AMPSMETER MAINSW/ LOADCENTER100-200 Amps 5 Terminals Lever Bypass Ringless120/240 VACGenerator Interlock33544 5U6281-XL-100-5T6-AMS216536281K5815 - large QN with small frame QK5820 - large frame QN with large frame QNK5830 - small frame Q to small frame Q4 5100-200 Amps 5 Terminals Meter Mains Lever Bypass Ringless 1Ø3WCatalog 00-5T6-AMS200200OH/UGOH/UGC.P.C.P.Connectors 6-350C.B.C.B.41 241 2141 8 391 4141 8 391 43321 221 222113Notes Breakers: Units are factory supplied with Siemens 200 Amps plug-in type QN2200RH breaker. Other amperagesavailable. When applicable, replace suffix with desired amperage (-100, -125, -150). Branch Breakers: Single-pole branch circuits available with feed through lugs. Interlock Kit: For generator auxiliary circuit breaker interlock for large frame QN with small frame Q orderK5815; for large frame QN with large frame QN order K5820; for small frame Q order K5830. K5815 and K5820compatible only with Siemens circuit breakers (for use with 6281).Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specificationsand features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com 4 43

14Manual Transfer Switch200 AMPSMANUALTRANSFERSWITCH200 Amps 5 Terminals Ringless 120/240 VAC11 2 1114834U4834-XL-200-5T9-AMSShown with 200 Amps auxiliary breaker.Auxiliary breaker sold separately.200 Amps 5 Terminals Manual Transfer Switch Ringless 1Ø3WCatalog rs koutsD"W"H"15 21739312 4,1 21Notes Auxiliary Breakers: Must be ordered separately. Use UQFP- (Amps) style breaker. Breakers: Comes with factory-installed sliding interlock to allow only one breaker to be in the ON positionPlease consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications andfeatures shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com

15Lever Bypass Meter Mains200 AMPSLEVER BYPASSMETER MAINS200 Amps 7 Terminals Ringless 240 VAC214257502 3U5750-RXL-200-BL-AMS200 Amps 7 Terminals Meter Mains with Breaker Heavy Duty Lever Bypass Ringless 3Ø4WCatalog P.Connectors 0-3005 417 834431133Notes Hubs: For proper hub selection, see the hub suffix chart on the accessories page. Bypass: Lever supplies clamping action on meter spades and also operates bypass device. Breaker: Factory installed 200 Amps, 3-pole, 10K AIC.Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specificationsand features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com 4

16320 AMPSLEVER BYPASSMETER MAINSHeavy Duty Lever Bypass Meter Mains320 Amps 5 Terminals Ringless 120/240 U5891-X-2/200-K3L-5T6-MLK-AMS1222234433 4589158925NOTEAmeren allows these units at 240 VAC and below.320 Amps 5 Terminals Meter Mains Heavy Duty Lever Bypass RinglessDimensionsBranch Connectors CU/ALBypassCircuitsLineLoadD" W" H"Catalog NumberService HubU5059-X-2/200-K3L-5T6-AMSOH/UG C.P.—#4-6001/0-300Lever47 815U5890-X-2/200-K3L-5T6-AMSOH/UG C.P.—#4-6001/0-300Lever6241 235U5891-X-2/200-K3L-5T6-MLK-AMS OH/UG C.P.12#4-6001/0-300Lever629 2U5892-X-2/200-K3L-5T6-MLK-AMS OH/UG C.P.24#4-6001/0-300Lever6291 21Knockouts1421 2 3234 4— — 4,1 21421 2135412 21135421 2111 35— — 2,3 4 1 3 2,3 4 1 3Notes Neutral: Bonded neutral and ground factory installed. Short Circuit Current Withstand Rating: 22K AIC standard. Bypass: Lever supplies clamping action and operates bypass device. -MLK: Feed-through lug kit. For field-installable feed-through lug kit, use part number K3701.Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications andfeatures shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com

17Meter Mains400 AMPSMETER MAIN400 Amps 5 & 7 Terminals Single & Three OTEAmeren requires these units at 240 VAC and below.400 Amps 5 Terminals Meter Mains 1Ø3WCatalog nnectors CU/ALDimensionsKnockoutsLineD”W”H”123#4-600 kcmil or(2) #1/0-2506361 434421 214 21 4400 Amps 7 Terminals Meter Mains 3Ø4WCatalog tors CU/ALDimensionsKnockoutsLineD”W”H”12#4-600 kcmil or(2) #1/0-250636 43442 213114 2 41400 Amps 7 Terminals Meter Main with Breakers Ringless 3Ø4WCatalog nectors CU/ALDimensionsLineD”W”H”#4-600 kcmil or(2) #1/0-2507371 434Knockouts1 2, 3 41Specifications AIC Rating: 22K AIC at 240 VAC. 300 Amps breaker: Can be installed from the factory (upon request).*Comes with two 200 Amps 3Ø breakersPlease consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary byutility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and mustcomply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specificationsand features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com21 2, 3 431 2, 3 441 2, 3 4

18200 AMPSLEVER BYPASSMULTIPOSITIONHD Lever Bypass Multi-Position Sockets200 Amps 5 Terminals Ringless 600 VAC221212287223U2873-XT-QG-AMS222222111 31 2222876200 Amps per Position 5 Terminals Multi-Position Heavy Duty Lever Bypass Ringless OH/UGConnectors CU/ALCatalog NumberPositionsMain BusRatingHubU2872-XT-QG-AMS2200 Amps(2) C.P.3U2873-XT-QG-AMS3270 Amps(2) C.P.3U2874-XT-QG-AMS4360 Amps(2) C.P.3U2875-XT-QG-AMS5450 Amps(2) C.P.3U2876-XT-QG-AMS6528 Amps(2) C.P.3DimensionsKnockoutsLineLoadD"W"H"12 8" x 16 Studs#6-350632 825 4 8" x 16 Studs#6-3506423 16 8" x 16 Studs#6-3506 8" x 16 Studs#6-350 8" x 16 Studs#6-3503412 21 4,1 2251 4421 21 4,1 2521 4251 4421 21 4,1 26625 16251 4421 21 4,1 2672 831 442 21 4,1 213111Notes Hubs: Units supplied with two closing plates. If hub is needed, refer to the hub suffix chart on the accessories page. Connector Kits: For line si

Ameren Service Area Product Catalog Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.com