Meter Mounting EquipmentAmeren Service Area

2MILBANKOVERVIEW About Milbank EmPOWERing the FutureMilbank Manufacturing Co., a third-generation family-owned business, has beenengineering and manufacturing electrical supplies, equipment and solutions foruse by utilities, contractors, distributors and OEMs since its founding in 1927.Today, Milbank’s meter mounting equipment is the standard by which all othersare measured. Our meter sockets and electrical enclosures can be foundon homes, schools, businesses, factories, roadways, RV parks, arenas, andairports across North America.Consistent with our vision to remain at the forefront of power generation anddistribution technology, and to honor our stewardship of the environment,Milbank launched its PowerGen division in 2009. The PowerGen productline, which features wind, solar, electric vehicle charging stations, andgenerators, incorporates renewable energy sources and distributed powergeneration while helping to advance smart grid initiatives.Expansive electrical experience.Our meter sockets, meter mains and electrical enclosures are known for theirquality, flexibility and reliability. Our products represent the extraordinaryknowledge and dedication of the employees that design, build and servicethem. Call 877.483.5314 today to find our more about our products or to findyour local Milbank distributor.

Disconnects30 & 60 Amp Air Conditioner Disconnects .5-6Hot Tub Disconnect / Sub Panel Breaker Enclosure . 7Single Position Meter Sockets125 & 200 Amp, 4 Terminal, Ringless. 8200 Amp, 4, 5 & 7 Terminal, Ringless, Lever Bypass . 9320 Amp, 4, 5 & 7 Terminal, Ringless, Lever Bypass . 10Meter Mains100-200 Amp, 4 Terminal, Ringless . 11100-200 Amp Unmetered Load Centers . 12100-200 Amp with Load Center .13-14200 Amp, 7 Terminal, Lever Bypass, Ringless . 15320 Amp, 4 & 5 Terminal, Lever Bypass, Ringless . 16Cold Sequence 200 Amp, Lever Bypass, Ringless . 17Manual Transfer Switch, 200 Amp . 18Multi-Position100 Amp, 4 Terminal, Ringless . 19200 Amp, 4 Terminal, Ringless . 20200 Amp, 5 Terminal, Lever Bypass, Ringless . 21200 Amp, 7 Terminal, Lever Bypass, Ringless . 22125 & 200 Amp, 4 Terminal, Meter Mains, Ringless .23-26200 Amp, 5 Terminal, Lever Bypass, Meter Main, Ringless. 27Transformer Rated, CT Cabinets & Mounting Racks20 Amp Lever Bypass Transformer Rated . 28800 Amp Transformer Cabinets . 29CT Cabinet Mounting Racks, Stud & Lug Type . 30Pedestals100/200 Amp Meter Main with Load Center Pedestal, 4 Terminal, Ringless. 31200 Amp Meter Main with Load Center Pedestal, 5 Terminal, Ringless, Lever Bypass . 32MiscellaneousTemporary Power Units . 33Pad Mounted Panel Board . 34Terminal Box . 35Commercial Meter Pedestals .36-41Generators .42-45Electric Vehicle Supply Equipment .46-48Circuit Breakers .49-50Accessories.51-53Reference Information.54-59Index .60-623TABLE OFCONTENTS

4CATALOGNUMBERLOGICCatalog Number LogicHow our product catalog numbers are derived

5Air Conditioner DisconnectsACDISCONNECTS60 Amp With 20 Amp GFCI ReceptacleU3802U3812U3832Milbank’s air conditioner disconnect has a removable hinged cover which makes wiring a breeze.Our compact design meets all wire bending space requirements in the NEC and, also, complieswith article 440-14 in the NEC. To ensure the safest conditions, we designed our disconnect pullersto be removable or they may be reinstalled in the off position. Another safety feature is the padlockprovision on the front cover. As with all Milbank products, our enclosure is constructed of G90Ugalvanized steel and finished with an attractive, light gray, baked powder coating. Our state of theart finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is thenelectrostatically applied. This offers a durable, nonfading finish.30-60 Amp — 1Ø 240 VAC — Air Conditioner DisconnectsWeight Line/Load Wire Fusible3U386260Fusible10DimensionsWire RatingGround WireRange CU/ALD"W"H"CU CAL C#12-#2#14-421 2571 260 /75 60 /75 #14-#2#12-#2#14-421 2571 260 /75 60 /75 2.5#14-#3#14-#3#14-312 85760 /75 60 3.3#14-#3#14-#3#14-321 85960 /75 60 /75 Notes UL listed as Enclosed Pullout Switch Type 3R rainproof One-inch concentric knockoutsUtility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

6Air Conditioner DisconnectsACDISCONNECTS60 Amp With 20 Amp GFCI ReceptacleU3822-20GWRSpecifications Meets NEC #210.63 requirements UL listed as Power Outlet Type 3R enclosure In-use cover* Duplex ground connector 1" concentric knockouts 1Ø, 240 volt 60 amp, non-fused 20 amp GFCI receptacle Reset/test button Weather and tamper resistant Meets NEC #406.8 requirements60 Amp — 1Ø, 240 Volt — Air Conditioner Disconnect with GFCI ReceptacleCatalogNumberTypeU3822-20GWR Non-FusibleMaxH.P.10Weight Line/Load Wire Range(lbs.)CUAL6#14-#2#12-#2DimensionsGround WireRange CU/ALD"W"H"#14-444 551 472 5Wire RatingCU CAL C60 /75 60 /75 Notes Disconnect Pullers: To ensure the safest conditions, Milbank disconnect pullers are reversible so they may bereinstalled in the OFF position. Padlock Provision: All units are designed with a padlock provision on the cover for security. *In-Use Cover: Cover is rated as an in-use cover (cover may be closed with cords plugged into receptacle).Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

7Hot Tub DisconnectHOT TUBDISCONNECTType 3R EnclosuresU4881-O-50GBU4881-O-60GBSpecifications 240 volt ground fault protection UL listed, Type 3R rainproof 2-pole, 50 amp GFCI breaker protection Compact size Three or four wire installation 1Ø, 120/240 VAC Standard package of 12 Two extra one-pole breaker spaces 100 amp overall rating Easy to installHot Tub Disconnect or Sub Panel Breaker Enclosure — Type 3RWeight Line/Load Wire Range(lbs.)CUALDimensionsGround WireRange CU/ALD"W"H"#14-1/0#14-1/033 417 281 2#14-1/0#14-1/0#14-1/033 417 281 2#14-1/0#14-1/0#14-1/033 471 281 2Catalog NumberAmpTypeU4881-O—Breaker B60Breaker8Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

8Single Position Sockets125/200 AMPSINGLEPOSITION125 & 200 Amp 4 Terminal Ringless 600 3323850244 Terminal — Single Position — Ringless — 1Ø3WCatalog NumberAmps ServiceHubConnectors 4 4 4U7487-RL-QG-KK125OHH.O.#6-2/0#6-2/0Horn3 16811 221 21 4151 211 41 4— 4— 4— 4—1U7487-YL-QG-KK125OH1 4"#6-2/0#6-2/0Horn3 16811 22U7021-RL-QG-KK200OHH.O.#6-350#6-350Horn41 88151 221 21U7021-DL-QG-KK200OH2"#6-350#6-350Horn41 88151 221 21U7040-XL-QG-KK200OH/UGC.P#6-350#6-350Horn41 811145 821 21U7040-O-QG-KK200UGBlank#6-350#6-350Horn14 81114 82 21U7043-O-QG-KK200UGBlank#6-350#6-350Horn74 81315 232 2U3850-O-QG-KK200UGBlank#6-350#6-350Horn41 213151 4321 2115111 4,1 21 4,1 21 4,1 21 4, 2111 4, 21 41111 2 4,1 21Notes Fifth Terminal: For field mounted fifth terminal on the U7487, order catalog number 5T8K2. For U7021, U7040,U7043 and U3850 order K5T. Hubs: For the proper hub selection see the hub suffix chart on the accessories page. Connectors: Extruded aluminum connectors are tin plated.Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

9Single Position Lever Bypass200 AMPSINGLEPOSITIONLEVER BYPASS200 Amp 4, 5 & 7 Terminal Ringless 600 00U9581-RXL-QGU9701-RXL-QGNOTEAmeren requires these units at 240 Volts and below. For all service voltagesabove 240V, see Cold Sequence products on page 17.200 Amp — 4 Terminal — Single Position — Lever Bypass — 1Ø3W — RinglessCatalog NumberServiceHubU9801-RXL-QGOH/UGC.P.Connectors koutsD"W"H"124 8131932 27134 4, 21 411200 Amp — 5 Terminal — Single Position — Lever Bypass — 1Ø3W or 3Ø3W — RinglessCatalog L-QG*Connectors .#6-350BypassDimensionsKnockoutsD"W"H"12Lever74 810118 232 2#6-350Lever47 81319321 21#6-350Lever4 8131932 2173311 44 4,1 21 4,1 21 4, 21 4 41200 Amp — 7 Terminal — Single Position — Lever Bypass — 3Ø4W — RinglessCatalog nectors sDimensionsKnockoutsD"W"H"12Lever74 810118 232 2Lever47 81319321 2331 4 4,1 214 4,1 21 41Notes *UAP: UL listed, painted aluminum is approved by Ameren and available upon request. Hubs: For proper hub selection see the hub suffix chart on the accessory page. Connectors: Extruded aluminum connectors are tin plated. U9550, U9551 and U9801 units includeremovable bonding strap for isolated neutral. Bypass: Lever supplies clamping action and also operates bypass device.Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

10Single Position Lever Bypass320 AMPSINGLEPOSITION320 Amp 4, 5 & 7 Terminal Ringless 600 L-K2L11143631 1 14 32131121121079U5786-X-K3-K2-BL57401211578649113 1142NOTEAmeren requires these units at 240 Volts and below.For commercial services, Ameren requires fifth terminal in 6 o’clock position. Order kit K3865.K4802 anti-inversion clip must be field installed in all 320A commercial meter sockets in the upper right-hand jaw.320 Amp — 4 Terminal — Single Position — Lever Bypass — 1Ø3W — RinglessCatalog LOH/UGC.P.Connectors CU/ALLineLoad#4-600 or(2) #1/0-250#4-600 or(2) #1/0-250#4-600 or(2) #1/0-250#4-600 or(2) #1/0-250Twin #350Twin #350BypassDimensionsKnockoutsD"W"H"1Lever74 81328 43Lever47 813383 43Twin #350Lever74 81531 43Twin #350Lever61 2173 4383 43132 4, 2121 2 4, 211 4134 4—11 4,1 21 411 4———320 Amp — 7 Terminal — Single Position — Lever Bypass — 3Ø4W — RinglessCatalog NumberServiceHubU4911-X-QG-BL**OH/UGC.P.Connectors CU/ALLine 8" x 16 Studs3Load 8” x 16 Studs3BypassLeverNotes* For 3Ø3W, use U1079 with 5th terminal in 6 o’clock position.** Studs will need lug kit on line/load. Isolation Kit: For isolated neutral kit for U5740, order K5979.Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.DimensionsKnockoutsD"W"H"123461 2173 4383 44311 4

11Meter Mains100-200 AMPMETER MAINS100-200 Amp 4 Terminal Ringless 120/240 VACU7375-RL-KK11U5842-RL-200-KK121737531 2U5844-XL-200-KK5842143221254234584434100-200 Amp — 4 Terminal — Meter Main — 1Ø3W — Horn Bypass — RinglessCatalog NumberServiceAmpsHubU7375-RL-KKOH100Connectors 6-1/0 CB33 418 8100/200 H.O.12345 4, 2———1 4, 21 4—— 4,1 21 4——2211 4111U5842-RL-KKOH#6-350CB4 88302 21U5842-RL-100-KKOH100H.O.#6-350#6-1/0 CB41 883021 21U5842-RL-200-KKOH200H.O.#6-350CB14 88302 21 4, 21U5844-XL-KKOH/UG200C.P.#6-350CB41 21430321 211U5844-XL-200-KKOH/UG200C.P.#6-350CB41 21430321 21111 4—— 2,3 41 4,1 2 2,3 41 4,1 2Notes Fifth Terminal: For field installed fifth terminal for U5842 and U5844, order K5T. For U7375, order 5T8K2.Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

12Unmetered Load CentersUNMETEREDLOAD CENTERS100-200 Amp 120/240 VAC221453 4597133 412U5971-XL-200USE-2233USE-22-200-MB100-200 Amp — Load Center with Main Breaker — 120/240VCatalog NumberMain ockoutsD"W"H"123C.P.14 214 8125 163211OH/UGC.P.41 2141 8251 163211OH/UGC.P.4 214 825 1632111111453 2, 41 4,1 2 2,3 41 4,1 2 2, 41 4,1 23Notes AIC Rating: 22K AIC rating. Line Terminals: As specified on circuit breaker (300 kcmil max). Load Terminals: As specified on circuit breakers (#1 AWG max). Breaker Interlock: Order K5815 for 200A or 150A to 100A breakers (large frame to small frame). Order K5820for 200A or 150A to 200A or 150A breakers (large frame to large frame). Order K5830 for 100A to 100A (smallframe to small frame).200 Amp — Main Power Outlet — Branch Provisions — 10K AIC Rated — 1Ø3WCatalog nectors 0048225 821Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.DimensionsKnockouts31 4,1 2

13Meter Main With Load Center100-200 AMPMETER MAINW/ LOADCENTER100-200 Amp 4 Terminal Ringless 120/240 VAC543 3126135168522 00 Amp — 4 Terminal — Meter Main w/ Load Center — Horn Bypass — Ringless — 1Ø3WCatalog NumberU5168-XTL-100-KKService Amps HubOHU5168-XL-200-KK-AMS OH/UGU5818-XL-200S-KKOHBranchCircuitsConnectors CU/ALDimensionsKnockoutsLineLoadD"W"H"12343032 221121 2211 2, 41 4—100C.P.10#6-350CB4 214 8200C.P.8#6-350CB41 2141 8 323 8200C.P.4#6-350CB5 2111103032113563 2, 41 2,3 41—Notes Fifth Terminal: For field installed fifth terminal, order K5T. Breakers: The U5168 is rated 22K AIC with Milbank QNR2200H main installed. Units are also available with 150or 175 amp breakers — replace -200 with -150 or -175. Interlock Kit: For generator auxiliary circuit breaker interlock, order K5815 for large frame QN with small frameQ; order K5820 for large frame QN with large frame QN.Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 4,1 2 4,1 2—

14Meter Main With Load Center100-200 AMPMETER MAINSW/ LOADCENTER5 Terminal Lever Bypass Ringless 120/240 VACGenerator InterlockK5815 - large QN with small frame Q3 31254K5830 - small frame Q to small frame Q5871587256K5820 - large frame QN with large frame QN345U5871-XL-200NOTEAmeren allows these units at 240 Volts and below. For commercial services, Amerenstandards require 5th terminal in 6 o’clock position on all units shown.100-200 Amp — 5 Terminal — Meter Mains — Lever Bypass — Ringless — 1Ø3WConnectors 1234U5871-XL-100-5T6OH/UGC.P.#6-350CB841 2141 8 331 2321 2211U5871-XL-200-5T9OH/UGC.P.#6-350CB841 2141 8 331 2321 2211U5872-XL-200-5T9OH/UGC.P.#6-350CB2041 2141 8 331 2321 2211Catalog NumberService HubH"56 2,3 41 4,1 2 2,3 41 2,3 41 4,1 2 4,1 2Notes Breakers: Units are factory supplied with Siemens 200 amp plug-in type QN2200RH breaker. Other amperagesavailable. When applicable, replace suffix with desired amperage (-100, -125, -150). Branch Breakers: Single-pole branch circuits available with feed through lugs. Fifth Terminal: For field installed fifth terminal, order K3866. Installs in the 6 o’clock or 9 o’clock position. Interlock Kit: For generator auxiliary circuit breaker interlock for large frame QN with small frame Q orderK5815; for large frame QN with large frame QN order K5820; for small frame Q order K5830. K5815 and K5820compatible only with Siemens circuit breakers.Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

15Lever Bypass Meter Main200 AMPLEVER BYPASSMETER MAIN200 Amp 7 Terminal Ringless 240 VAC214257502 3U5750-RXL-200-BL200 Amp — 7 Terminal — Meter Main with Breaker — Lever Bypass — Ringless — 3Ø4WCatalog NumberAmpsU5750-RXL-200-BL200Service HubOH/UGC.P.Connectors 0-30053 4173 8344311 4Notes Hubs: For proper hub selection see the hub suffix chart on the accessory page. Bypass: Lever supplies clamping action on meter sapdes and also operates bypass device. Breaker: Factory installed 200 amp, 3-pole, 10,000 AIC.Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

16Lever Bypass Meter Mains320 AMPLEVER BYPASSMETER MAINS320 Amp 4 & 5 Terminal Ringless 120/240 2/200-K3L1222234433 4589158925NOTEAmeren allows these units at 240 Volts and below. For commercial services, Amerenstandards require 5th terminal in 6 o’clock position on all units shown.K4802 anti-inversion clip must be field installed — see below.320 Amp — 4 Terminal — Single Position — Lever Bypass — RinglessCatalog NumberService HubConnectors neLoad#4-6001/0-300 8 x 16 Stud 8 x 16 Stud 8 x 16 KnockoutsD"W"H"1Lever74 815142 231/0-300Lever624 2351/0-300Lever6291 2351/0-300Lever629 235112345 4—— 4, 2142 21421 21142 2111111 3—— 2,3 41 3 2, 41 33Notes Required Anti-Inversion Clip: For required field installable metal tab that prevents 200A meters from beinginstalled on 320A socket, order K4802. Neutral: Bonded neutral and ground factory installed. Short Circuit Current Withstand Rating: 22K AIC standard. Bypass: Lever supplies claming action and operates bypass device. Fifth Terminal: For field installed fifth terminal, order K3865 for U5890, U5891 and U5892. For U5059, orderK3866. For Commercial Services: Add 5th terminal in the 6 o’clock position. -MLK: Feed-through lug kit.Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

17Cold Sequence Meter MainsCOLDSEQUENCEMETER MAINS5 & 7 Terminal Ringless111 1 13 23U5787-O-200-CB200 Amp Circuit Breaker Disconnect Ahead Of Meter Socket — Lever BypassDimensionsKnockoutsService Terminals SystemHubConnectorsCU/AL - 274 32134331U5765-X-200-CB*OH/UG53Ø3WC.P.#6-350427 32134331U5767-X-200-CB*OH/UG73Ø4WC.P.#6-350274 32134331U5784-O-200-5T-CBUG51Ø3WBlank#6-350274 322628U5785-O-200-CBUG53Ø3WBlank#6-350427 3226U5787-O-200-CBUG73Ø4WBlank#6-3504 3226Catalog Number272341 4, 21 4— 4,1 21 4— 4, 21 4—1312 211 4, 21 428321 21 4,1 21 42832 21 4, 21 411200 Amp T-Fuse Pullout Disconnect Ahead of Meter Socket — Lever BypassDimensionsKnockoutsService Terminals SystemHubConnectorsCU/AL - 74 32134331U5765-X-200-TFOH/UG53Ø3WC.P.#6-350427 32134331271Catalog Number2341 4, 21 4— 4,1 21 4— 4, 21 4—U5767-X-200-TFOH/UG73Ø4WC.P.#6-3504 3213433U5784-O-200-5T-TFUG51Ø3WBlank#6-350427 322628321 21 4,1 21 4U5785-O-200-TFUG53Ø3WBlank#6-350274 322628312 211 4, 21 4U5787-O-200-TFUG73Ø4WBlank#6-3504 32262832 21 4, 21 427111Notes *Overhead Only Approval: The U5764, U5765 and U5767 are only approved for overhead service inSt. Louis city and county. Fuses: Fuse holder only. Fuses not supplied. Use Class T fuses. Application: Suitable for use as service equipment only. Barrel Lock: Barrel lock provision on meter panel available. Add -BL suffix to end of catalog number. Service: UL listed for overhead and underground use. Consult utility for underground use acceptance. Circuit Breaker: Circuit breaker type rated: 200 amp, 600V @ 22K AIC, 480V @ 35K AIC, 240V @ 65K AIC.Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

18Manual Transfer Switch200 AMPMANUALTRANSFERSWITCH200 Amp 4 & 5 Terminal Ringless 120/240 VAC111 2 111441211 2 114834U4834-XL-200-5T6U4412-RL-200-100-KKShown with 200 Ampauxiliary breaker200 Amp — 4 Terminal — Manual Transfer Switch — Ringless — 1Ø3WConnectors CU/ALDimensionsBypassKnockoutsCatalog OHH.O.#6-350*See NoteHorn51 2173431U4412-RL-200-200-KKOHH.O.#6-350*See NoteHorn51 21734312 4,1 2 4,1 2Notes *Connectors for Load Side: (2) #6-350, and (1) #14-1/0 per phase. Hubs: For proper hub selection see the hub suffix chart on the accessory page. Breakers: The Milbank UQFB-A-200-X1 bolt-on main circuit breaker is factory installed. Auxiliary power sideuses the UQFP series circuit breaker. Auxiliary Breaker Connectors Line Side: #3-#1 CU, #1-1/0 AL for 100 & 125 amp. 1/0 to 300 for 150-200 amp. Breaker Lockout Sliding Bar: Prevents both breakers from being “ON” at the same time.200 Amp — 5 Terminal — Manual Transfer Switch — Ringless — 1Ø3WCatalog NumberServiceHubU4834-XL-200-5T6OHC.P.Connectors koutsD"W"H"151 21739321 4,1 2Notes Auxiliary Breakers: Must be ordered separately. Use UQFP-(AMP) style breaker. Fifth Terminal: The -5T6 suffix indicates a factory-installed fifth terminal in the 6 o’clock position.Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

19Multi-Position Sockets100 AMPMULTIPOSITION100 Amp 4 Terminal Ringless 300 VAC32222 313 2238032U8032-XL-KK3232 32222 312 323 2123 2222 32 322380333 2 33 2222380353 2 32223 212 3223 23 2123 2222 32 328034323 2238036100 Amp per Position — 4 Terminal — Multi-Position — RinglessCatalogNumberPositions Service HubConnectors 8032-XL-KK2OH/UGC.P.#6-350#6-2/0Horn4 224 2162 221U8033-XL-KK3OH/UGC.P.#6-350#6-2/0Horn14 21132 161612 221U8034-XL-KK4OH/UGC.P.#6-350#6-2/0Horn41 2407 81621 221U8035-XL-KK5OH/UGC.P.#6-350#6-2/0Horn14 2149 161612 221U8036-XL-KK6OH/UGC.P.#6-350#6-2/0Horn41 2571 41621 2211 2 2 2 2 2Notes Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page. Connectors: Extruded aluminum connectors are tin plated.Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

20Multi-Position Sockets200 AMPMULTIPOSITION200 Amp 4 Terminal Ringless 300 VAC222 4 51212523 4 2U1252-X-QG-KK-K122 42221 3 5 24 222 44 222125321 3 1 5 2 4222212552 44 22212541 3 1 5 2 44 22 44 222222 44 24 2221 3 1 5 2 42212562 44 2200 Amp per Position — 4 Terminal — Multi-Position — RinglessCatalog NumberPositions Service HubConnectors 1252-X-QG-KK-K12OH/UGC.P.#6-350#2-350Horn51 8261 214321 211 21 4U1253-X-QG-KK-K13OH/UGC.P.#6-350#2-350Horn15 834 214312 211 21 4U1254-X-QG-KK-K14OH/UGC.P.#6-350#2-350Horn15 842 416312 211 21 4U1255-X-QG-KK-K45OH/UGC.P. (2) #2-600#2-350Horn51 8543 416321 211 21 4U1256-X-QG-KK-K46OH/UGC.P. (2) #2-600#2-350Horn5 862 81832 211 21 411371Notes Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page. For the U1254-6 two hubopenings are supplied and the extra opening is closed with a closing plate as standard. Fifth Terminal: For field mounted fifth terminal, order catalog number K5T (9 o’clock position). Connectors: Extruded aluminum connectors are tin plated.Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

Lever Bypass Multi-Position Sockets200 Amp 5 Terminal Ringless 300 VAC221212287223U2873-XT222222111 31 2222876200 Amp per Position — 5 Terminal — Multi-Position — RinglessCatalogNumberPositions ServiceConnectors CU/ALHubLineLoad 8" x 16 Stud#6-350 8" x 16 StudBypassDimensionsKnockoutsD"W"H"12Lever632 825 4#6-350Lever6423 16 8" x 16 Stud#6-350Lever6 8" x 16 Stud#6-350Lever 8" x 16 Stud#6-350LeverU2872-XT2OH/UG(2) C.P.U2873-XT3OH/UG(2) C.P.3U2874-XT4OH/UG(2) C.P.3U2875-XT5OH/UG(2) C.P.3U2876-XT6OH/UG(2) C.P.333412 21251 4421 2152 425 4412 216625 16251 4421 21672 831 442 211131111 4,1 2 4,1 2 4,1 2 4,1 2 4,1 2Notes Hubs: Units supplied with two closing plates. To order hubs as extra, refer to the hub suffix chart on theaccessories page. Connector Kits: For line side connector kits, order as extra K1539 (350 kcmil), K1540 (600 kcmil), twin K1350(350 kcmil), twin K1541 (600 kcmil). Line connectors can be reversed to change from “OH” to “UG” service. Forline side connector lug kits, order as extra from chart on accessories page. Bypass: Lever supplies clamping action on meter spades and also operates bypass device.Utility requirements for this equipment may vary.Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.21200 AMPLEVER BYPASSMULTIPOSITION

22200 AMPLEVER BYPASSMULTIPOSITIONLever Bypass Multi-Position Sockets200 Amp 7 Terminal Ringless 300 VAC221212273223U2732-XT222222111 31 3

Ameren Service Area. MILBANK OVERVIEW 2 Milbank Manufacturing Co., a third-generation family-owned business, has been . which features wind, solar, electric vehicle charging stations, and generators, incorporates renewable energy sources and distributed power generation while helping to advance smart grid initiatives. . Manual Transfer .