Caterpillar 1500kW XQ1500 - Global Power Supply

Transcription

Caterpillar 1500kW XQ1500#4375 Diesel 480V EPA Tier 2www.globalpwr.comGenerator Features2007 Caterpillar 1500 kW XQ1500 Diesel Generator.This XQ package features a sound attenuatedenclosure, CAT 3512 engine, has only 1082 hours andmeets EPA Tier 2 Emissions Standards. CAT 1500 kW XQ1500 Diesel Engine Model 3512 EPA Tier 2 Emissions Compliant Manufactured in 2007 1082 Hours 1800 RPM 480V / 60Hz / 3 Phase Sound Attenuated Enclosure All Digital Control Panel 1500 kW Standby Rating Serial Number: BNR00332 Engine Serial Number: 1GZ04070 Sku# 4375Call for PriceSPECIFICATIONSModel NumberStandby RatingYear ManufacturedHoursXQ15001500 kW20071082Empowering YouWe are a full service provider of new and used integrated power systems including dieselgenerators, natural gas generators, genset enclosures, fuel tanks, automatic transfer switches (ATS),HVAC/CRAC equipment and paralleling switchgear.FOR MORE INFORMATION:(800) 706-0906info@globalpwr.comGLOBAL POWER SUPPLY 2016 Global Power Supply, llc. All Rights ReservedSpecifications are subject to change.(805) 683-3828 20160314TRP

R E N T A LXQ1500SOUND ATTENUATEDPOWER MODULE60 HzFEATURESEMISSIONSEPA and CARB Emissions Certified for non-roadmobile applications.CAT DIESEL GENERATOR SETSFactory designed, certified prototype tested withtorsional analysis. Production tested and deliveredto you in a package that is ready to be connectedto your fuel and power lines. Electric PowerDesign Pro computer sizing available. Supported100% by your Caterpillar dealer with warranty onparts and labor. Extended warranty available insome areas. The generator set was designed andmanufactured in an ISO 9001 compliant facility.Generator set and components meet or exceedthe following specifications: AS1359, AS2789,ABGSM TM3, BS4999, DIN6271, DIN6280,EGSA101P, JEM1359, IEC 34/1, ISO3046/1,ISO8528, NEMA MG1-22.CATERPILLAR SR4B GENERATORSingle bearing, wye connected, static regulated,brushless permanent magnet excited generatordesigned to match the performance and outputcharacteristics of the Caterpillar diesel enginethat drives it.W H E R ET H EW O R L DRELIABLE, FUEL EFFICIENT DIESELThe compact, four-stroke-cycle diesel enginecombines durability with minimum weight whileproviding dependability and economy. The fuelsystem operates on a variety of fuels.CATERPILLAR COOLING SYSTEMSized compatible to rating with energy efficientfan and core.CATERPILLAR SWITCHGEARSingle unit or optional paralleling components.Circuit breakers, bus bars, and connection panelready to connect.EXCLUSIVE CATERPILLAR VOLTAGEREGULATORThree-phase sensing and adjustable Volts-perHertz regulation give precise control, excellentblock loading, and constant voltage in thenormal operating range.SOUND ATTENUATED ISO CONTAINERFor ease of transportation and protection.Meets 70 dBA at 50 ft or below per SAE J1074measurement procedure.T U R N SF O RP O W E R

R E N T A LFACTORY INSTALLED STANDARD & OPTIONAL oolingSwitchgearStandardOptionalAir cleaner, with service indicatorBatteriesFilters; fuel, RH with service indicators; lubricating oilInsulated mufflerJacket water heaterPump, fuel priming — RHRadiatorService meterStandard eight-gauge instrument panelSump pumpGovernorElectronic ADEM IISR4B brushless, 480 volt, PM excited three-phasewith digital voltage regulator, space heaterAir intake louversBus bar access doorFuel tank — 4730 L (1250 Gal) UL listedFuel/water separator110 VAC/24 VDC lightingSound attenuated (75 dBA @ 50 ft)ISO hi cube containerLockable doorsStainless steel hardware and hingesVertical radiator and exhaust discharge plenumStandard cooling provides 110 ambient at prime ratingFloorstanding switchgear with EMCP II componentsAutomatic start/stop with cooldown timerBattery charger, heavy duty 20AProtection: 32, 59Circuit breaker, electrically operatedConnection terminals, 3-phase and neutralAutomatic parallelingAuxiliary power connections for jacket water heater,battery charger, space heatersMeters: power factor, KW, PF, W/WHM,synchroscope, KVARProtection: 27, 40, 810, 81UCIM, CCM, remote annunciationPlug and peak shave utility conversion panelSPECIFICATIONSCAT SR4B GENERATORType . . . . . . Static regulated brushless PM excitedConstruction . . . . . . Single bearing, close coupledThree-phase . . . . . . . . . . . Wye connected — 6 leadInsulation . . . . . . . . . . . Class H — 2 extra dips andbakes on random wound unitsEnclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . Drip proofAlignment . . . . . . . . . . . . . . . . . . . . . . . . . . . Pilot shaftOverspeed capability . . . . . . . . . . . . . . . . . . . . . 130%Voltage regulator . . . . . . . . . . 3-phase sensing withVolts-per-HertzVoltage regulation . . . . . . . . . . . . . . Less than 0.5%Voltage gain . . . . . . Adjustable to compensate forengine speed droop and line lossWave form . . . . . . . . . . . . . . Less than 5% deviationTIF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 50THD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 3%CAT 3512B ENGINEV-12, 4-stroke-cycle dieselBore — mm (in) . . . . . . . . . . . . . . . . . . . . . . . 170 (6.7)Stroke — mm (in) . . . . . . . . . . . . . . . . . . . . . 190 (7.5)Displacement — L (cu in) . . . . . . . . . . . . 51.8 (3158)Aspiration . . . . . . . . . . . . Turbocharged-Aftercooled2

R E N T A LTECHNICAL DATAPower Rating60 HzStandby1500ekWEngine and Container InformationEngine ModelContainer sizeContainer dimensionsFuel Capacity Hours of Operationat 60% Load Factor4732 L (1250 Gal) Standard 12 m (40 ft)9464 L (2500 Gal) Optional 12 m (40 ft)hourshoursApproximate Weight (Dry) —Container with Generator Set and SwitchgearIncluding ContainerWith Undercarriagekg (lb)kg (lb)Prime13603512B12 (40)see belowm (ft)1122122422 680 (50,000)26 765 (59,000)Container Dimensions12192.0 [480.00]R1219.2 [R48.00]2 Places2438.4 [96.00]R963.3 [R37.92]3 PlacesR744.5 [R29.31]2 Doors Each Side(Cable Storage Box)12192.0 [480.00]7723.5 [304.07]1877.2 [73.90]4114.8 [162.00]13500.1 [531.50]The power module must have support under the center when seton the ground.DimensionsLengthWidthHeight312192.0 mm2438.4 mm4114.8 mm480.00 in96.00 in162.00 in

R E N T A LSTANDARD CONTROLS12 m (40 ft) CONTAINERS480V/60 HzALARM ACKNOWLEDGE/LAMP TESTSWITCHThree-position, spring return to centerswitch for alarm acknowledge and lamptest of all discrete indicating lamps. Lamptest shall also sound the alarm horn.Floorstanding switchgear includes thefollowing functions and features:ELECTRONIC MODULAR CONTROL PANEL(EMCP II) COMPONENTSANNUNCIATION CIRCUITSUpon receipt of an alarm or shutdowncondition, the horn shall sound and an LEDshall flash. Upon acknowledgement fromalarm acknowledge/lamp test switch, thehorn shall be silenced and the lampsteadied. LED shall be extinguished whenECS is placed in the off/reset position if thealarm condition has been corrected.Circuits are recurring such that the LEDshall flash and the horn sound, shouldanother fault occur even prior to correctionof the initial fault.GENERATOR SET CONTROL (GSC)MonitoringSequentially rotating, backlit LCD displayof engine hours, engine rpm, DC batteryvoltage, oil pressure, and watertemperature. Includes pushbutton to holddisplay on any single parameter.ProtectionShutdowns:Overspeed, overcrank, high watertemperature, low oil pressure, andemergency stop. With LED indicator foreach condition.Alarms:Low coolant levelAC MeteringThree-phase volts (L-L), amperes andfrequency with phase select pushbutton,on backlit LCD. Metering accuracy is0.5%.ControlAutomatic starting with field adjustablecycle crank, failure to start (overcrank),and cooldown timer.Programming and DiagnosticsIncludes field programmable set-points forengine control and monitoring variablesand self diagnosis of EMCP II systemcomponent and wiring failures.EMERGENCY STOP PUSHBUTTONMushroom head, twist to reset, causesengine shutdown and tripping of thegenerator circuit breaker. Prevents enginestarting when depressed.MANUAL PARALLELINGControls consisting of reverse power relay,synchronizing lights, and switch. Reversepower condition causes tripping of thegenerator circuit breaker, immediate engineshutdown, flashing of indicating lamp, andsounding of alarm horn.CIRCUIT BREAKERFixed mounted, three-pole, manuallyoperated, molded case circuit breaker withsolid state trip unit for overload (timeovercurrent) and fault (instantaneous)protection. Includes DC shunt trip coilactivated on any generator set monitoredfault. Circuit breaker is sized for full loadcapacity of the generator set at 0.8 powerfactor.ALARM MODULEFlashing LED warnings for: low coolanttemperature, high coolant temperature(pre-alarm), low oil pressure (pre-alarm),engine control switch not in automatic, andlow DC voltage. Includes alarm horn andacknowledge pushbutton.LOAD SHARE GOVERNORElectronic load sharing governor withspeed adjust potentiometer, idle/ratedswitch, and isochronous/droop switch.ENGINE CONTROL SWITCHSnap action rotary switch, four-position —off/reset, automatic, manual,stop/cooldown. Off/reset for engineshutdown and resetting faults, automaticfor remote starting by customer contactclosure, manual for local starting andmanual paralleling, stop/cooldown formanual operation cooldown.VOLTAGE REGULATORStandard Caterpillar generator-mounteddigital voltage regulator with voltage adjustrheostat mounted in the floorstandingswitchgear.4

R E N T A LSTANDARD CONTROLS (Continued)CURRENT TRANSFORMERS (3)Five-ampere secondary with shortingterminal strips4160V POWER MODULESSimilar to 480V units except for thefollowing:All bus bars are silver plated copperGenerator circuit breaker, 3-pole, vacuumtype, manually operated with 24 VDCshunt trip. Sized for generator voltageand current ratings. Includes draw-outovercurrent relay, with instantaneoussetting, ANSI device 50/51.POTENTIAL TRANSFORMERS (3)120 VAC secondary with primary andsecondary fuse protection, two connectedto the generator side of the circuit breaker,one connected to the load side of thecircuit breaker.BUS BARSThree-phase plus fully rated neutral busbars with NEMA standard hole pattern forconnection of customer load cables andgenerator cables. Bus bars are sized forfull load capacity of the generator set at0.8 power factor. Also includes ground bus,connected to the generator frame groundand container frame with holes forconnection of field ground cable. Bus barsare accessible from outside of the powermodule via hinged, lockable cable accessdoor.ACCESSORY POWER3500 Power ModulesThree 230 VAC (50 Hz units) or 120 VAC(60 Hz units) shore power connections forjacket water heaters, generator spaceheater, and battery charger.BATTERY CHARGER24 VDC/20A battery charger with float/equalize modes and charging ammeter.5

R E N T A Lwww.CAT-ElectricPower.comU.S. sourcedLEHX0533 (10-00) 2000 CaterpillarAll rights reserved.Printed in U.S.A.Materials and specifications are subject to change without notice.The International System of Units (SI) is used in this publication.

CATERPILLAR SR4B GENERATOR Single bearing, wye connected, static regulated, brushless permanent magnet excited generator designed to match the performance and output characteristics of the Caterpillar diesel engine that drives it. RELIABLE, FUEL EFFICIENT DIESEL The compact, four-stroke-cycle diesel engine combines durability with minimum weight while providing dependability and