Simple Logger Ii Data Loggers

Transcription

SIMPLE LOGGER IIDATA LOGGERSAC Current AC Voltage DC CurrentDC Voltage Thermocouple Programmable storage modes Programmable storage rates Stores up to 240,000measurements Runs on Alkaline batteries Optically isolated USB port Includes DataView graphing,analysis and report generationsoftware Display and analyze real-timedata on your PCTechnical Hotline: (800) 343-1391www.aemc.com

DATA LOGGING MADE SIMPLE Simple Logger IIFEATURES True RMS measurements providean accurate representation ofmeasured signals for AC models Choice of data storage modes toassist in matching the data collectionfor the application needs Stores over 240,000 measurements,ensuring that no valuable data ismissed; (greater than 8 hours at 8samples per second; approximately 1week at one sample every 2 seconds) Compact size and battery operated Easily installed anywhere quickly,operational in seconds Display and analyze real-time datathrough your PCL562 monitoring voltage and current in a load center.The Simple Logger II data logger family is a cost effective, advanceddesigned product line incorporating features and functions not found indata loggers costing 2 to 3 times their price.The choice of data storage modes and storage rates allows the operatorto effortlessly configure these loggers to optimize memory usage to theapplication at hand.Extended Recording Mode (XRM ) and delayed start time are just two ofthe many application friendly features in these loggers.An internal memory of 512kB allows for storing over 240,000measurements, more than enough for most data collection needs. All ACmeasurement loggers are True RMS (TRMS) and all DC measurementloggers allow the user to program both scale and engineering units.A full set of alarm programming tools allows for programming alarm setpoints and triggering on high, low, inside or outside trigger points.Their battery operation and compact size allows for installation in tightlocations without the need for external power. A series of front panelLEDs provides a quick status of the logger’s state and memory usage.DataView application software is included, providing real-time viewingof measurement data even while recording. Instrument configuration, datastorage and report generation from pre-defined templates or operatorcustom designed templates are also standard features. Several dataloggers can be synchronized to record at the same time intervals usingDataView , as well.APPLICATIONS DataView assists the electrician orengineer in finding problems thatoccur randomly in fault/intermittentcurrent detection Neutral current monitoring, findsunwanted leakage currents Harmonic real-time currentmonitoring, locates unwanted energythat causes equipment failure Load profiling which sizes loads forproper transformer and meterselection Split phase load monitoring forresidential voltage and current Machine load monitoring findsoverload conditions that causepremature equipment failure dueto overheating Process loop monitoring - findstroubled sensors and controls HVAC and general temperatureprofilingNine models are available to record various AC, DC or Temperaturemeasurements. The following pages will provide more specific informationon each model, available accessories and the DataView software.2www.aemc.comTechnical Assistance (800) 343-1391

Simple Logger II SoftwareDataView software provides a convenient way to configure andcontrol power analysis tests from your computer. Through the useof clear and easy-to-use tabbed dialog boxes, all Simple Logger IIfunctions can be configured and tests can be initiated. Results canbe displayed in real time and stored in your PC or the logger. Reportsmay be printed along with the operator’s comments and analysis.DataView is includedwith all Simple Logger IImodels.FEATURESQuick and simpleconfiguration of allfunctions and settingsfrom one dialog box.Real-time view of trend, waveform and status screens.MINIMUM SYSTEMREQUIREMENTS Display and analyze real-time data onyour PC Record real-time to your PC Configure all data logger functions andparameters from your PC includingsample rate, recording length, channelconfiguration and more Create and store a library ofconfigurations that can be uploaded tothe logger as needed Zoom in and out and pan throughsections of the graph to analyze thedata Download, display and analyzerecorded data Display waveforms, trend graphs,harmonics (AC models) and textsummaries, real-time Create custom views and reports Print reports using standard or customtemplates you design Free software upgrades Windows 2000/XP/Vista operatingsystem 128MB of RAM for Windows 2000(256MB recommended)256MB of RAM for Windows XP512MB of RAM for Windows Vista 80MB of hard disk space(200MB recommended) CD-ROM driveWindows a registered trademark of Microsoft Corporationin the United States and/or other countries.Technical Assistance (800) 343-1391Configure all alarm functions with straightforwardselections.www.aemc.com3

Simple Logger IITRMS Clamp-On Current Model CL601FEATURESModel CL601 includes type A to5-pin mini-B USB 2M, DataView CD, two 1.5V AA-cell Alkalinebatteries and user manual.Model CL601SPECIFICATIONSMODELELECTRICALChannelsInput ConnectionCurrent RangeResolutionAccuracy (50/60Hz)Sample RateStorage RateStorage ModesRecording LengthMemoryCommunicationPower SourceBattery LifeMECHANICALDimensionsCL601OneSplit CT – AC Current0 to 600Aac0.1A Machine load monitoring HVAC troubleshooting Load profiling Electrical troubleshooting Start-Stop time stampingProgrammable from 125mS to 1 dayStart/Stop, FIFO and Extended Recording Mode (XRM )15 minutes to 8 weeks, programmable using DataView 240,000 measurements (512KB) The recorded data is stored in nonvolatile memory retained even if the battery is low or removed.USB 2.0 optically isolated2 x 1.5V AA-cell Alkaline batteries100 hours to 45 days (dependent on storage rate/recording length)9.25 x 4.0 x 1.63" (235 x 102 x 41mm)1 conductor - Ø 1.65" (42 mm), 2 conductor - Ø 1.00" (25.4 mm) eaWeight (with battery)17.1 oz (485 grams)VibrationAPPLICATIONS0 to 5A: unspecified5 to 50A: (1% of Reading 1A)50 to 400A: (1% of Reading 0.5A)400 to 600A: (3% of Reading 1A)64 samples/cycleMax Conductor SizeCase 0 to 600Arms True RMS AC measurements Self contained, no exposed connections Overload indication Optically isolated USB 2.0 output(cable included) One button operation Alarm function 5 LED indicators quickly and clearlydisplay logger status Includes FREE DataView software for datastorage, real-time display, analysis andreport generation USB cable included 300V Cat. IV, 600V Cat. IIIUL94-V0IEC 68-2-6 (1.5mm, 10 to 55Hz)ShockIEC 68-2-27 (30G)DropIEC 68-2-32 (1m)ENVIRONMENTALOperating Temperature14 to 122 F (-10 to 50 C)Storage Temperature-4 to 140 F (-20 to 60 C)Easily log current in power panels.CATALOG NO.DESCRIPTIONSimple Logger II Model CL601 (1-Channel, TRMS Clamp-On, 600Aac)4www.aemc.com2126.01Technical Assistance (800) 343-1391

Simple Logger IITRMS Current Model L101Model L101 includes type A to5-pin mini-B USB 2M, DataView CD, two 1.5V AA-cell Alkalinebatteries and user manual.Probes sold separately.Model L101SPECIFICATIONSMODELELECTRICALChannelsL101Input ConnectionBNCCurrent Probe OutputVoltage RangeResolutionAccuracy (50/60Hz)One0 to 1V (probe dependent)0.1mV0 to 10mV: unspecified10 to 50mV: (0.5% of Reading 1mV)50 to 1000mV: (0.5% of Reading 0.5mV)Sample Rate64 samples/cycleStorage RateProgrammable from 125mS to 1 dayStorage ModesStart/Stop, FIFO and Extended Recording Mode (XRM )Recording Length15 minutes to 8 weeks, programmable using DataView MemoryCommunicationPower SourceBattery LifeMECHANICALDimensionsMax Conductor SizeWeight (with battery)CaseVibration240,000 measurements (512KB) The recorded data is stored in nonvolatile memory and retained even if the battery is low or removed.USB 2.0 optically isolatedFEATURES Compatible with standard AC current probeswith voltage output and BNC connection (seechart on page 13 for compatible current probes) 64 samples per cycle Programmable storage rates from 8 persecond to 1 per day 3 user selectable storage modes Stores up to 240,000 measurements innon-volatile memory Powered by standard Alkaline batteries Lightweight, compact, fits anywhere 5 LED indicators quickly and clearly displaylogger status Includes FREE DataView software for datastorage, real-time waveform display, analysisand report generation Isolated USB communication USB cable included 50V Cat. IIIAPPLICATIONS Load profiling Fault current detection Intermittent problem detection Demand recording Neutral current monitoring Harmonic current monitoringusing DataView software Metering CT resizing Start-Stop time stamping2 x 1.5V AA-cell Alkaline batteries100 hrs to 45 days (dependent on storage rate/recording length)5.38 x 2.75 x 1.28" (136 x 70 x 32mm)Current probe dependent6.4 oz (180 grams)UL94-V0IEC 68-2-6 (1.5mm, 10 to 55Hz)ShockIEC 68-2-27 (30G)DropIEC 68-2-32 (1m)ENVIRONMENTALOperating Temperature14 to 122 F (-10 to 50 C)Storage Temperature-4 to 140 F (-20 to 60 C)L101 recording branch circuit current.CATALOG NO.DESCRIPTIONSimple Logger II Model L101 (1-Channel, TRMS 0 to 1Vac)Technical Assistance (800) 343-13912126.02www.aemc.com5

Simple Logger IITRMS Current Model L102Model L102 includes type A to5-pin mini-B USB 2M, DataView CD, two 1.5V AA-cell Alkalinebatteries and user manual.Probes sold separately.Model L102SPECIFICATIONSMODELELECTRICALChannelsInput ConnectionCurrent Probe OutputVoltage RangeResolutionAccuracy (50/60Hz)L102TwoOne BNC connector per channel0 to 1V (probe dependent)0.1mV0 to 10mV: unspecified10 to 50mV: (0.5% of Reading 1mV)50 to 1000mV: (0.5% of Reading 0.5mV)Sample Rate64 samples/cycleStorage RateProgrammable from 125mS to 1 dayStorage ModesStart/Stop, FIFO and Extended Recording Mode (XRM )Recording Length15 minutes to 8 weeks, programmable using DataView MemoryCommunication240,000 measurements (512KB) The recorded data is stored in nonvolatile memory & retained even if the battery is low or removed.USB 2.0 optically isolatedPower SourceBattery Life2 x 1.5V AA-cell Alkaline batteries100 hours to 45 days (dependent on storage rate/recording length)MECHANICALDimensionsMax Conductor SizeWeight (with battery)CaseVibrationFEATURES Two independent channels Compatible with standard AC current probeswith voltage output and BNC connection (seechart on page 13 for compatible current probes) 64 samples per cycle 2 inputs Programmable storage rates from 8 persecond to 1 per day 3 user selectable storage modes Stores up to 240,000 measurements innon-volatile memory Powered by standard Alkaline batteries Lightweight, compact, fits anywhere 5 LED indicators quickly and clearly displaylogger status Includes FREE DataView software for datastorage, real-time waveform display, analysisand report generation Isolated USB communication USB cable included 50V Cat. IIIAPPLICATIONS Split phase load monitoring Neutral and ground current monitoring Intermittent problem detection Harmonic current monitoring usingDataView software Machine load monitoring Start-Stop time stamping5.38 x 2.75 x 1.28" (136 x 70 x 32mm)Current probe dependent6.4 oz (180 grams)UL94-V0IEC 68-2-6 (1.5mm, 10 to 55Hz)ShockIEC 68-2-27 (30G)DropIEC 68-2-32 (1m)ENVIRONMENTALOperating Temperature14 to 122 F (-10 to 50 C)Storage Temperature-4 to 140 F (-20 to 60 C)L102 recording two phases of primary feed.CATALOG NO.DESCRIPTIONSimple Logger II Model L102 (2-Channel, TRMS 0 to 1Vac )6www.aemc.com2126.03Technical Assistance (800) 343-1391

Simple Logger IITRMS Current Model L111FEATURESModel L111SPECIFICATIONSMODELELECTRICALChannelsInput ConnectionCurrent Probe OutputCurrent RangeResolutionAccuracy (50/60Hz)Model L111 includes type A to5-pin mini-B USB 2M, DataView CD, two 1.5V AA-cell Alkalinebatteries and user manual.Probes sold separately.L111OneTwo recessed banana jacks0 to1A (probe dependent)0.1mA0 to 10mA: unspecified10 to 50mA: (0.5% of Reading 1mA)50 to 1000mA: (0.5% of Reading 0.5mA)Sample Rate64 samples/cycleStorage RateProgrammable from 125mS to 1 dayStorage ModesStart/Stop, FIFO and Extended Recording Mode (XRM )Recording Length15 minutes to 8 weeks, programmable using DataView MemoryCommunicationPower SourceBattery LifeMECHANICALDimensionsMax Conductor SizeWeight (with battery)CaseVibration240,000 measurements (512KB) The recorded data is stored in nonvolatile memory & retained even if the battery is low or removed.USB 2.0 optically isolated2 x 1.5V AA-cell Alkaline batteries Compatible with standard AC currentprobes with current output and banana plugconnection Fused input 64 samples per cycle Programmable storage rates from 8 persecond to 1 per day 3 user selectable storage modes Stores up to 240,000 measurements innon-volatile memory Powered by standard Alkaline batteries Lightweight, compact, fits anywhere 5 LED indicators quickly and clearlydisplay logger status Isolated USB communication Includes FREE DataView software fordata storage, real-time waveform display,analysis and report generation USB cable included 50V Cat. IIIAPPLICATIONS Load profiling Fault current detection Intermittent problem detection Demand recording Neutral current monitoring Harmonic current monitoringusing DataView software Metering CT resizing Start-Stop time stamping100 hrs to 45 days (dependent on storage rate/recording length)5.18 x 2.75 x 1.28" (132 x 70 x 32mm)Current probe dependent6.64 oz (188 grams)UL94-V0IEC 68-2-6 (1.5mm, 10 to 55Hz)ShockIEC 68-2-27 (30G)DropIEC 68-2-32 (1m)ENVIRONMENTALOperating Temperature14 to 122 F (-10 to 50 C)Storage Temperature-4 to 140 F (-20 to 60 C)CATALOG NO.DESCRIPTIONSimple Logger II Model L111 (1-Channel, TRMS 0 to 1Aac)Technical Assistance (800) 343-13912126.04www.aemc.com7

Simple Logger IITRMS 600VAC/AC DC Model L261FEATURESModel L261SPECIFICATIONSMODELSELECTRICALChannelsInput ConnectionVoltage RangeResolutionAccuracy (50/60Hz)Sample RateStorage RateModel L261 includes type A to5-pin mini-B USB 2M, DataView CD, two 1.5V AA-cell Alkalinebatteries and user manual.L261OneTwo recessed banana jacks0 to 600Vac/ac Dc0.1V0 to 5V: unspecified5 to 50V: (0.5% of Reading 1V)50 to 600V: (0.5% of Reading 0.5V)64 samples/cycleProgrammable from 125mS to 1 dayStorage ModesStart/Stop, FIFO and Extended Recording Mode (XRM )Recording Length15 minutes to 8 weeks, programmable using DataView MemoryCommunicationPower SourceBattery LifeMECHANICALDimensionsWeight (with battery)CaseVibration TRMS voltage recording up to 600VAC/AC DC 64 samples per cycle Programmable storage rates from 8 persecond to 1 per day 3 user selectable storage modes Stores up to 240,000 measurements innon-volatile memory Powered by standard Alkaline batteries Lightweight, compact, fits anywhere 5 LED indicators quickly and clearlydisplay logger status Includes FREE DataView software fordata storage, real-time waveform display,analysis and report generation Isolated USB communication USB cable included 300V Cat. IV; 600V Cat. IIIAPPLICATIONS Surge and Sag recording Long term supply monitoring Industrial, commercial, residentialmonitoring Monitor voltage harmonics Find intermittent voltage problems Machine monitoring240,000 measurements (512KB) The recorded data is stored in nonvolatile memory & retained even if the battery is low or removed.USB 2.0 optically isolated2 x 1.5V AA-cell Alkaline batteries100 hours to 45 days (dependent on storage rate/recording length)4.94 x 2.75 x 1.28" (125 x 70 x 32mm)6.4 oz (180 grams)UL94-V0IEC 68-2-6 (1.5mm, 10 to 55Hz)ShockIEC 68-2-27 (30G)DropIEC 68-2-32 (1m)ENVIRONMENTALOperating Temperature14 to 122 F (-10 to 50 C)Storage Temperature-4 to 140 F (-20 to 60 C)Model L261 includes set of two color-coded 5 ft voltageleads, color-coded alligator clips (red/black)Cat. #2140.62CATALOG NO.DESCRIPTIONSimple Logger II Model L261 (1-Channel, TRMS 600Vac/ac Dc)2126.05Accessory/ReplacementLead set includes 2, color-coded 5 ft (1.5M) w/color-coded alligator clips (red/black), rated 600V Cat. IV, 15A8www.aemc.comTechnical Assistance (800) 343-13912140.62

Simple Logger IITRMS Voltage/Current Model L562FEATURESModel L562 includes type A to5-pin mini-B USB 2M, DataView CD, two 1.5V AA-cell Alkalinebatteries and user manual.Probes sold separately.Model onInput ConnectionInput RangeResolutionAccuracy (50 or 60Hz)Sample RateStorage RateStorage TechniqueRecording LengthMemoryCommunicationPower SourceBattery LifeMECHANICALDimensionsMax Conductor SizeWeight (with ng TemperatureStorage TemperatureL562TwoCurrent ChannelBNC0 to 1Vac*Voltage ChannelTwo recessed banana jacks0 to 600VAC/DC0.1mA0.1V0 to 10mV unspecified0 to 5V unspecified10 to 50mV: (0.5% of Reading 1mV)5 to 50V: (0.5% of Reading 1V50 to 1000mV: (0.5% of Reading 0.5mV) 50 to 600V: (0.5% of Reading 0.5V)64 samples/cycleProgrammable from 125mS to 1 dayStop when full, FIFO and Extended Recording Mode (XRM )15 minutes to 8 weeks, programmable using DataView 240,000 measurement (512KB). The recorded data is stored in non-volatilememory & retained even if the battery is low or removed.USB 2.0 optically isolated2 x 1.5V AA-cell Alkaline batteries100 hours to 45 days (dependent on storage rate/recording length)5.38 x 2.75 x 1.28" (136 x 70 x 32mm)Current probe dependent6.4 oz (181 grams)UL94-VOIEC 68-2-6 (1.5mm, 10 to 55Hz)IEC 68-2-27 (30G)IEC 68-2-32 (1m) 2 input channels Voltage: 0 to 600Vac/Dc TRMS Current: compatible with currentprobes with voltage outputs (seepage 13) 64 samples per cycle 3 user selectable storage modes Programmable storage rates from 8per second to 1 per day Stores up to 240,000 measurementsin non-volatile memory Powered by standard Alkalinebatteries Lightweight, compact, fits anywhere 5 LED indicators quickly and clearlydisplay logger status Includes FREE DataView softwarefor data storage, real-time waveformdisplay,analysis and reportgeneration USB cable included 300V Cat. IV; 600V Cat. III with asafety rated current probe attachedAPPLICATIONS Single phase power monitoring Residential, commercial, industrialtroubleshooting Find sags and surges Track energy usage Start-Stop time stampingModel L562 includes set of two color-coded 5 ftvoltage leads, color-coded alligator clips (red/black)Cat. #2140.62(See page 8 for ordering information)14 to 122 F (-10 to 50 C)-4 to 140 F (-20 to 60 C)CATALOG NO.DESCRIPTIONSimple Logger II Model L562 (TRMS Voltage & Current)Technical Assistance (800) 343-13912126.35www.aemc.com9

Simple Logger II4 to 20mADC Current Model L322FEATURESModel L322 includes type A to5-pin mini-B USB 2M, DataView CD, two 1.5V AA-cell Alkalinebatteries and user manual.Model L322SPECIFICATIONSMODELELECTRICALChannelsInput ConnectionMeasurement RangeL322TwoOne 4 position removable screw-type terminal block-20 to 20mADcResolution0.01mAAccuracy0.25% of Reading 0.05mA)Sample RateStorage RateMaximum of 8 samples taken at storage intervalProgrammable from 125mS to 1 dayStorage ModesStart/Stop, FIFO and Extended Recording Mode (XRM )Recording Length15 minutes to 8 weeks, programmable using DataView MemoryCommunicationPower SourceBattery LifeMECHANICALDimensionsWeight (with battery) 2 independent input channels -20 to 20mADc Programmable storage rates from 8 persecond to 1 per day 3 user selectable storage modes Stores up to 240,000 measurements innon-volatile memory Scaling and engineering units inputtedthrough software prior to saving Powered by standard Alkaline batteries Lightweight, compact, fits anywhere 5 LED indicators quickly and clearlydisplay logger status Includes FREE DataView software fordata storage, real-time display, analysisand report generation USB cable included 50V Cat. IIIAPPLICATIONS Process control monitoring andtroubleshooting Profile temperature, pressure, flowand other parameters directly General purpose DC current monitoring And many more240,000 measurements (512KB)The recorded data is stored in non-volatile memory &retained even if the battery is low or removed.USB 2.0 optically isolated2 x 1.5V AA-cell Alkaline batteries100 hours to 45 days(dependent on storage rate/recording length)5.45 x 2.75 x 1.28" (136 x 70 x 32mm)6.4 oz (181 grams)CaseUL94-V0VibrationIEC 68-2-6 (1.5mm, 10 to 55Hz)ShockIEC 68-2-27 (30G)DropIEC 68-2-32 (1m)ENVIRONMENTALOperating Temperature14 to 122 F (-10 to 50 C)Storage Temperature-4 to 140 F (-20 to 60 C)L322 recording loop current in a flow control panel.CATALOG NO.DESCRIPTIONSimple Logger II Model L322 (4 to 20mADc Current)10www.aemc.com2126.06Technical Assistance (800) 343-1391

Simple Logger IIDC Voltage Model L432FEATURESModel L432SPECIFICATIONSMODELELECTRICALChannelsInput ConnectionMeasurement Range(3 ranges/channel)ResolutionAccuracy(50/60Hz)Sample RateStorage RateStorage ModesRecording LengthMemoryCommunicationPower SourceBattery LifeMECHANICALDimensionsWeight (with battery)CaseVibrationModel L432 includes type A to5-pin mini-B USB 2M, DataView CD, two 1.5V AA-cell Alkalinebatteries and user manual.L432TwoOne 4 position removable screw-type terminal blockRange 1: -100mV to 100mVDcRange 2: -1V to 1VDcRange 3: -10V to 10VDcRange 1: 0.1mVRange 2: 1mVRange 3: 10mVRange 1: (0.5% of Reading 1mV)Range 2: (0.5% of Reading 1mV)Range 3: (0.5% of Reading 10mV)Maximum of 8 samples taken at storage interval 2 independent input channels User-selectable ranges of 100mV; 1V and 10VDC per channel Programmable storage rates from 8 persecond to 1 per day 3 user selectable storage modes Stores up to 240,000 measurements innon-volatile memory Powered by standard Alkaline batteries Lightweight, compact, fits anywhere 5 LED indicators quickly and clearlydisplay logger status Includes FREE DataView software fordata storage, real-time display, analysisand report generation USB cable included 50V Cat. IIIAPPLICATIONS Circuit design troubleshooting Sensor monitoring Battery testing Power supply profilingProgrammable from 125mS to 1 dayStart/Stop, FIFO and Extended Recording Mode (XRM )15 minutes to 8 weeks, programmable using DataView 240,000 measurements (512KB) The recorded data is stored in non-volatilememory & retained even if the battery is low or removed.USB 2.0 optically isolated2 x 1.5V AA-cell Alkaline batteries100 hours to 45 days (dependent on storage rate/recording length)5.45 x 2.75 x 1.28" (136 x 70 x 32mm)6.4 oz (181 grams)UL94-V0IEC 68-2-6 (1.5mm, 10 to 55Hz)ShockIEC 68-2-27 (30G)DropIEC 68-2-32 (1m)ENVIRONMENTALOperating Temperature14 to 122 F (-10 to 50 C)Storage Temperature-4 to 140 F (-20 to 60 C)L432 recording two DC voltage supplies.CATALOG NO.DESCRIPTIONSimple Logger II Model L432 (2-Channel, DC 100mV/1V/10VDc)Technical Assistance (800) 343-13912126.07www.aemc.com11

Simple Logger IIThermocouple Model L642FEATURESModel L642SPECIFICATIONSMODELELECTRICALChannelsInput ConnectionMeasurement Range:JKTNERSResolutionAccuracySample RateStorage RateStorage ModesRecording LengthMemoryCommunicationPower SourceBattery LifeMECHANICALDimensionsWeight (with ng TemperatureStorage TemperatureModel L642 includes type A to5-pin mini-B USB 2M, DataView CD, two 1.5V AA-cell Alkalinebatteries and user manual.Thermocouples sold separately.L642TwoTwo miniature thermocouple connectors F ( C)-346 to 2192 (-210 to 1200)-328 to 2501 (-200 to 1372)-328 to 752 (-200 to 400)-328 to 2372 (-200 to 1300)-238 to 1742 (-150 to 950)32 to 3212 (0 to 1767)32 to 3212 (0 to 1767)0.1 C/F 1000 C/F; 1 1000 C/F0.1% to 0.2% 0.6 to 1 , depending on the range and T/C type8 samples taken at storage intervalProgrammable from 5 sec to 1 dayStart/Stop, FIFO and Extended Recording Mode (XRM )15 minutes to 8 weeks, programmable using DataView 240,000 measurements (512KB) - The recorded data is stored in nonvolatile memory & retained even if the battery is low or removed.USB 2.0 optically isolated2 x 1.5V AA-cell Alkaline batteries100 hours to 45 days (dependent on storage rate/recording length)4.94 x 2.75 x 1.28" (125 x 70 x 32mm)7 oz (200 grams)UL94-V0IEC 68-2-6 (1.5mm, 10 to 55Hz)IEC 68-2-27 (30G)IEC 68-2-32 (1m)14 to 122 F (-10 to 50 C)-4 to 140 F (-20 to 60 C) 2 input channels User selectable thermocouple typesJ, K, T, N, E, R, and S Programmable storage rates from 1 per5 seconds to 1 per day 3 user selectable storage modes Stores up to 240,000 measurements innon-volatile memory Powered by standard Alkaline batteries Lightweight, compact, fits anywhere 5 LED indicators quickly and clearlydisplay logger status Includes FREE DataView software fordata storage, real-time display, analysisand report generation UBS cable included 50V Cat. IIIAPPLICATIONS HVAC monitoring Process monitoring Refrigeration monitoring And many moreOptional Thermocouple SensorsPlease consult AEMC forrecommendations on thermocouples.J ThermocoupleK ThermocoupleT ThermocoupleN ThermocoupleE ThermocoupleR & S ThermocoupleCATALOG NO.DESCRIPTIONSimple Logger II Model L642 (Temperature Thermocouple)12www.aemc.com 2126.08Technical Assistance (800) 343-1391

ACCESSORIESCurrent Probes Compatible with the Simple Logger II SeriesModel SL261Model MN261Model MR461Model MR561Model SR661Model JM861ModelMeasurement RangeOutput SignalACVoltageSL261*100mA to 10A1 to 100A100mV/Aac10mV/AacMN2610.1 to 24A0.5 to 240A100mVac/Aac10mVac/AacMR461*0.2 to 40A0.5 to 400AMR561*PhaseShift**Adapter, Banana (Female) - BNC(Male) (XM-BB)Maximum Conductor SizeOutputConnectionØ CableBus Bar 1.5 0.46"(11.8mm)N/ALeadw/BNC 2.5 0.78"(19.8mm)N/ALeadw/BNC10mV/Aac1mV/Aac 1.5 One 1.18"(30mm)Two 0.95"(24mm)2 x 500kcmilTwo 1.2 x 0.4"(31.5 x 10mm)Leadw/BNC0.2 to 100A0.5 to 1000A10mV/Aac1mV/Aac 1.5 One 1.5"(39mm)Two 0.98"(25mm)One 1.96 x 0.49"(50 x 12.5mm)Two 1.96 x 0.19"(50 x 5mm)Leadw/BNCSR6610.1 to 10A0.1 to 100A1 to 1000A100mVac/Aac10mVac/Aac1mVac/Aac 1 2.05"(52mm)1.96 x 0.19"(50 x 5mm)Leadw/BNCJM8611 to 30A1 to 300A1 to 3000A10mVac/Aac1mVac/Aac0.1mVac/Aac 1 2.52"(64mm)2.52 x 3.94"(64 x 100mm)1.97 x 5.31"(50 x 135mm)Leadw/BNC* For AC measurements**Phase shift indicated at maximum rating. Not all models are UL approved; please consult factory. Note: Maximum input to Simple Logger II is 1 Volt.CATALOG NO.DESCRIPTIONAC/DC Current Probe Model SL261 (10A-100mV/A, 100A-10mV/A, BNC)1201.51AC Current Probe Model MN261 (24A-100mV/A, 240A-10mV/A, BNC)2115.82AC Current Probe Model MR461 (60A-10mV/A, 600A-1mV/A, BNC)1200.72AC Current Probe Model MR561 (150A-10mV/A, 1500-1mV/A, BNC)1200.73AC Current Probe Model SR661 (10A-100mVac/Aac, 100A-10mVac/Aac, 1000A-1mVac/Aac, BNC)2113.49AC Current Probe Model JM861 (30A-10mVac/Aac, 300A-1mVac/Aac, 3000A-0.1mVac/Aac, BNC)2110.90Adapter, Banana (Female)-BNC (Male) (XM-BB)2118.46Technical Assistance (800) 343-1391 www.aemc.com13

INPUTS & RECORDINGINPUT CONNECTIONSSimple Logger II L101Isolated BNC connector acceptscurrent probes with male BNC plugs.Simple Logger II L102Dual isolated BNC connectors acceptscurrent probes with male BNC plugs.Simple Logger II L111Recessed 4mm banana jacks &fused inputSimple Logger II L261Recessed safety 4mm banana jacksSimple Logger II L322 & L4324-pin removable terminal stripSimple Logger II L562Isolated BNC for current probe.Recessed 4mm banana jacks forvoltage accepts current probes withmale BNC plugs.All Simple Logger II ModelsMini USB 5-pin connectorType A to 5-pin mini-B USB 2MCat. #2126.49Simple Logger II L642Dual miniature thermocouple connectorsRECORDING MODESThe Simple Logger II data logger family offers the choice of three modes of recording data.The first, and most common in the industry, is called Start/Stop. In this mode the operator selects a storage rate fromthe 21 predefined values from as fast as 8 per second (1 every 125mS) to 1 every day. Then a start and stop time isselected. Data is recorded at this rate until the memory is filled or the end recording time and date is reached. Thelogger then stops recording and goes into a standby mode retaining the recorded date to be downloaded.The second mode is a variant of Start/Stop called First in First Out (FIFO). Here the operator makes the data storageselection and recording length selection as described above however if the memory fills before the end date and timeoccurs, the logger will discard the oldest stored data point and add a new one. This process will continue until the endrecording date and time is reached.The third storage mode is called Extended Time Recording (XRM ). This unique recording mechanism provides forcontinuous recording over a longer period of time without the need for operator selection or adjustments to the setup. In this mode the operator selects a starting storage rate from the 21 predefined values from as fast as 8 persecond (1 every 125mS) to 1 every day. Recording length is also programmed. The logger will store data at therate selected until the memory is filled. When the memory is full, the logger will discard every other stored samplebeyond the first one, freeing up half the memory for continuous recording. New samples will be stored at half theprevious storage rate such that they match the interval for the remaining stored data. This process will repeateach time the memory fills until the operator stops the recording manually, the end recording date and time isreached or the battery runs down.14www.aemc.comTechnical Assistance (800) 343-1391

TRAINING SEMINARSAEMC offers one-day training seminars throughout the USA on Ground Resistance Testing,Insulation Resistance Testing and Power Quality. Public and private c ourses are available.For the schedule of upcoming t

Technical Assistance (800) 343-1391 www.aemc.com 3 Simple Logger II Software FEATURES Display and analyze real-time data on your PC Record real-time to your PC Configure all data logger functions and