TRUE BLUE - Teledyne Defense Electronics

Transcription

TRUE BLUE L OW LOS SC AB LE AS S EM B LI ESThe Answer: An unmatched combinationof low loss, durability, and value.The Question: What does Storm’s TrueBlue line of cable assemblies provide?For more than 30 years, our True Blue assemblies have been the winning choiceof design, test, and production engineers for:F E A TU R E SB E NE F I TS Compression resistant lowloss, low density dielectric Low insertion loss andexcellent amplitude stability Less prone to damage duringhandling and installation Quadraform shielding Military and aerospacedesign-in applications Laminate construction provideslow signal leakage General purpose test applications Production testingWith a design based entirely onhigh-performance materials, theTrue Blue line covers frequencies fromDC to 50 GHz.Assemblies are available in both customconfigurations and a variety ofstandard lengths and connectorcombinations. Longer cable assembly life dueto greater connector retention Highly reliable solderedconnections Longer cable assembly life dueto greater connector retention Low insertion loss and excellentamplitude stability Various standard connectoroptions and a number ofready-to-ship standardassemblies Reduced lead time forconfigured assemblies Cost-effective, same-dayshipment options forstandard configurationsThe basic True Blue cable is designedto be durable. However, for applicationsrequiring added durability, assembliesare also available ruggedized,armored, and soft armored.High value microwave andelectronic interconnect solutionswww.teledynestorm.com

LOW LOSS FLEXIBLE : TRUE BLUE .370.420/10.67Operating Frequency (Max, GHz)50.026.51812.0Attenuation–Nominal @ 2 GHz (dB/ft)0.2310.1100.0780.054Attenuation–Nominal @ 10 GHz (dB/ft)0.5320.2590.1850.131Attenuation–Nominal @ 18 GHz (dB/ft)0.7250.3570.257–Attenuation–Nominal @ 26.5 GHz (dB/ft)0.8920.444––Attenuation–Nominal @ 50 GHz (dB/ft)1.262–––Power Handling–Avg. (watts @ 1 GHz)28075014001700Phase Stability vs. Temperature (ppm, nominal)2800210016001500Phase Stability vs. Flex* (degrees @ 18 GHz, nominal)3.503.254.503.50†Amplitude Stability vs. Flexure* (dB @ 18 GHz, .2520.00/65.6236.00/118.1185.00/278.87Diameter (plain cable, in/mm)Minimum Bend Radius (in/mm)Shielding Effectiveness–Minimum (dB @ 1 GHz)Weight (grams/ft & /m)20590 290Cable Designator:125TRUE BLUEOperating Temperature Range ( C)† At 12 GHz–55 to 125* 90 degree bends around a:2"/50.80 mmmandrel4.5"/114.30 mm 4.5"/114.30 mmmandrelmandrel8"/203.20 mmmandrelSpecifications subject to change without notice.CABLE CONSTRUCTIONOur flexible low loss microwave cables are built to withstand mechanical abuse without loss of performance.However, for extra rough applications Storm offers the additional protection of ruggedizing, armoring, and softarmoring. A silver-plated copper conductor is insulated with a tough, low density PTFE dielectric that is then shieldedwith multiple outer conductor layers and insulated with FEP.ABCDEFASilver-plated (OFHC) copper center conductorDOverlapped aluminum laminate foilBA strong, low density PTFE dielectricEHigh coverage silver-plated copper braidCHigh coverage, silver-plated copper ribbon braidFExtruded blue FEP jacket630.754.3300nwww.teledynestorm.com

TRUE BLUE 125 & 205CONNECTOR OPERATING FREQUENCY18 GHzSMASPSPSJPRAAmmmmSM3.52.918 GHzSP26.5 GHzSJSP40 GHzmmmmmm50 GHz2.92.42.4TRUE BLUE 125CONNECTOR COMBINATIONPART NUMBERS*26.5 GHz40 GHz50 GHz2.4 mm SP1396 1502 1394 2344 2341 2342 23432.4 mm SJ1502 1648 2348 2349 2345 2346 23472.9 mm SP1394 23482.9 mm SJ2344 2349 11163.5 mm SP2341 2345 1127 2352SMA SP2342 2346 2353 2354 2350011069SMA RAP2343 2347 2355 2356 23510690709411116 1127 2353 23559422352 2354 23562232350 2351O R D E R I N G I N F O R M A T I O N : Part Number DesignationARMORINGDESIGNATORCONNECTORCOMBINATION PART NUMBERCABLEDESIGNATORASSEMBLY LENGTHIN INCHES90SEE EXAMPLESArmoring Designator: See Back Page.Leave Blank for Unarmored.EXAMPLES:CONNECTOR CODESRAPRight-Angle PlugBulkheadFeedthru JackBFJ* Other connector stylesavailable; consult Storm.4 GHz18 SMPSPSPSJRAASMASMASMmmmmm7m3.53.54 GHzStraight Jack90-1396-048 Unarmored True Blue 125, 2.4 mm SP to 2.4 mm SP (assembly operates to 50 GHz), 48 inchesA90-660-120 Hard Armored True Blue 205, 3.5 mm SP to 3.5 mm SJ (assembly operates to 26.5 GHz), 120 inches90-010-036 Unarmored (FEP jacket) True Blue 205, SMA SP to SMA SP (assembly operates to 18 GHz), 36 inches90P-0101-036 Unarmored (polyurethane jacket) True Blue 205, SMA SP to SMA SP (assembly operates to 18 GHz), 36 inchesTRUE BLUE 205CONNECTORCOMBINATIONPART NUMBERS*18 GHzStraight PlugSJJacket option for unarmored True Blue 205 only: To order polyurethanejacket in place of standard FEP, use Cable Designator 90P.26.5 GHz26.5 GHzSP3.5mm SP 2216603.5mm SJ660962 2390 824 2408 2409 2410 2415 2416 2417 2418 2412 2413 2414 2419 24707mm245 2390 222491346313 2391 247 2395 2396 2397 240 2393 2394 2398 2469SMA SP246491010066095096077102101103097099100693SMA RAP2399 2408 346066067261265264272266255242271 2422 238487SMA SJ2400 2409 313095261079986 2427 274 2428 2429 2424 2425 2426 2430 2471SMA BFJ2401 2410 2391 096265986080843844 2435 2436 2432 2433 2434 2437 2472N SP348 2415 247264 2427 843088076092093094718N RAP2404 2416 2395 102272076090273576226823 2451 2455 2477N SJ2405 2417 2396 101266 2428 2435 092273089 2456 2447 2449 2452 2457 2478N BFJ2406 2418 2397 103255 2429 2436 093576 2456 091227 2450 093 2458 2479TNC SP696 2412 240097242 2424 2432 094226 2447 227081TNC RAP2403 2413 2393 099271 2425 2433 718823 2449 2450 086TNC SJ697 2414 2394 098 2422 2426 2434 340 2451 2452 093TNC BFJ2407 2419 2398 100238 2430 2437 2454 2455 2457 2458 087BNC SP694 2470 2469 693487 2471 2472 2476 2477 2478 2479 2473 2474 2475 2480 664824245246 2399 2400 2401 348 2404 2405 2406 696 2403 697 2407 694077274844630.754.3300n086098340 2454 2476085087 2473083 2448 537 2474085 2448 082 2453 2475537 2453 084 2480www.teledynestorm.com

TRUE BLUE 290 & 420CONNECTOR OPERATING FREQUENCY18 GHzCTNJBFPRASP220270 2357 2363 2364 248434294 2367 339 2365 2366SMA SP270014207SMA RAP2357 200SMA SJ2363 199 2358 188 2368 538 2372 2373 2374 2369 2370 2371SMA BFJ2364 201881 2368 190 2378 2379 2380 2381 2375 2376 2377N SP248206535N RAP434208388 2372 2379 214N SJ294207 2362 2373 2380 213 2387 196 2389 312 2383 2386N BFJ2367 209200201206208189 2358 881535388 2362 738 2359 2360 2361199538 2378 195214209213215TNC SP339TNC RAP2365 204 2360 2370 2376 531TNC BFJ2366 205 2361 2371 2377 929 2385 2386 937202 2359 2369 2375 216CABLEDESIGNATOR202216197 2387 2388 217738 2374 2381 215 2388 2389 198217312218204531205929550 2385218 2384 937191550 2383 2384 211211212193 2382212 2382 194CONNECTOR CODESCONNECTORCOMBINATION PART NUMBERASSEMBLY LENGTHIN INCHES90SPStraight PlugSJStraight JackRAPRight-Angle PlugBulkheadFeedthru JackBFJSEE EXAMPLES*Armoring Designator: See Back PageLeave Blank for UnarmoredEXAMPLES:CTNJBF7mmO R D E R I N G I N F O R M A T I O N : Part Number JSPPRAAAASMSMSMm18 GHz7mTRUE BLUE 290CONNECTOR COMBINATIONPART NUMBERS*Other connector stylesavailable; consult Storm.A90-189-048 Hard Armored True Blue 290, SMA RAP to SMA RAP (assembly operates to 18 GHz), 48 inches90-144-120 Unarmored True Blue 420, SMA SP to TNC SP (assembly operates to 12 GHz), 120 inchesCONNECTOR OPERATING FREQUENCY12 GhzPAPCRSSCTNPJBFPRASPCSTNNNN8 GhzSP12 GhzASMTRUE BLUE 420CONNECTOR COMBINATIONPART NUMBERS*8 GhzSMA SP0121481501511441462332N SP1480781561571587612333N RAP15015613923370727372339N BFJ15115723371401592335 2338TNC SP1441580721590751532334TNC RAP14676173723351530732336SC SP2332 2333 2339 2338 2334 2336 2340630.754.3300nwww.teledynestorm.com

LOW LOSS FLEXIBLE : TRUE BLUE CABLE ATTENUATION DATA140B U L K C A B L E AT T E N U AT I O N ( d B / 1 0 0 ' ) lueBTrue1201251008060 e 205True Blu40 e 290True Blu20 True Blue00Maximum4201020304050FREQUENCY (GHz)For cable assembly insertion loss, call us or visit our Web site, www.teledynestorm.com.10,000CABLE CW POWER – SEA LEVEL AND 25 C10987654AV E R A G E P O W E R - WAT T S321000TrueBlue 42TrueBlue 0290109876TrueBlue 20554TrueB3lue 2345671.089101020FREQUENCY (GHz)630.754.3300nwww.teledynestorm.com

TRUE BLUELOW LOSSCABLE ASSEMBLIES ARMORING & RUGGEDIZING OPTIONSAll options available for True Blue 205 and True Blue 290. Othercable types armored or ruggedized on request. Consult us for options.RUGGEDIZED – Polyolefin jacketArmoring Designator: RFor applications requiring a slightly greater amount ofcompression resistance (300 lbs/in), but where weightand flexibility are also critical. The cable is covered witha flexible wound helix of passivated stainless steel wireand a cross-linked polyolefin jacket.Temperature: –54 C thru 135 CDiameter:RUGGEDIZED – Polyurethane jacketArmoring Designator: PRTrue Blue 205 – 0.340"/8.64 mmTrue Blue 290 – 0.405"/10.29 mmFor applications similar to the above, where weight, flexibility,and moderate compression resistance (300 lbs/in) areimportant, but where abrasion resistance is also critical.The cable is covered with a flexible wound helix of passivatedstainless steel wire and an extruded polyurethane jacket.Temperature: –54 C thru 100 CDiameter:HARD ARMOREDArmoring Designator: ATrue Blue 205 – 0.360"/9.14 mmTrue Blue 290 – 0.420"/10.67 mmDesigned for both inside and outside environments whereflexibility and weight are not as critical, but where theapplication requires the ultimate in cut and crush resistance(500 lbs/in). The cable is covered with a stainless steelinterlocked armor; an additional cross-linked polyolefinjacket is standard on lengths up to 50 feet.Temperature: –54 C thru 135 CDiameter:SOFT ARMOREDArmoring Designator: SATrue Blue 205 – 0.420"/10.67 mmTrue Blue 290 – 0.530"/13.46 mmFor applications requiring abrasion resistance combinedwith improved compression resistance (400 lbs/in). Productstill remains very flexible. The FEP-jacketed cable is protectedwith a high density polyethylene anti-compression helix(205 only) that is covered with a tough fuel and oil resistantNeoprene synthetic rubber. Per MIL–R–6855, Class 2, Grade 60.Temperature: –54 C thru 100 CDiameter:AS9100/ISO 9001 REGISTEREDTrue Blue 205 – 0.505"/12.83 mmTrue Blue 290 – 0.470"/11.94 mm10221 Werch DriveWoodridge, Illinois 60517Tel 630.754.3300Fax 630.754.3500Toll Free 888.347.8676storm d for Public Release 18-00504/19

LOW LOSS FLEXIBLE : TRUE BLUE 0 20 40 60 80 100 120 140 0 10 20 30 40 50 FREQUENCY (GHz) BULK CABLE A TTENUA TION (d B / 100') r ue Blu e 420 T rue Blue 290 T rue Blue 205 T rue Blue 125 Maximum CABLE ATTENUATION DATA For cable assembly insertion loss, call us or visit our Web site, www.teledynestorm.com. 40 100 1000 10,000 4 5 6 .