PROGENETDATACENTERINSIDETHISISSUEPG. 2Overview of the Data CenterPG. 3Features of the Data CenterPG. 5Specifications of the data centerOVERVIEWOF THE PROGENET DATA CENTERProgenet is pleased to announce the 1st Cloud Data Center in Malaysia. Ideally located inSelangor, it is well connected to the rest of the Klang Valley via major expressways such asNKVE, LDP , DUKE highway, making it accessible to all.The Progenet Data Center, being truly carrier neutral, can offer high quality, scalable datacenter solutions, customised to fit customer requirements with net usable space of 7,000sqftper floor.

MORE ABOUT THE DATA CENTERThe Progenet Data Center, being truly carrier neutral, can offer highquality, scalable data center solutions, customised to fit customerrequirements with net usable space of 7,000sqft per floor.Our Data center can provide a minimum of N 1 configuration andconcurrent maintainability for both critical power and cooling systemswhich is similar to international Tier 3 standards.Our Data Center will be able to support multiple clusters of high end andhi-tech data center facilities. The facility is designed with high endinfrastructure to support the critical data center operations in event ofany emergencies.Having a single point of entry, 24X7 hours security facilities withcontrolled access & surveillance security cameras as well as perimeterhardened wall structure, the data center will be security tight with zerotolerance for security breaches.

KEY FEATURESOF THE DATA CENTER INFRASTRUCTURE Vertiv UPS with Hot swappable Modular Architecture with highdouble conversion power efficiency, compact footprint,distributed Intelligence allowing no single point of failure for fullredundancyVertiv SPM Power Distribution Unit with breakers and BranchCircuit Monitoring for each individual rack for real time powerconsumptionVertiv In Row Precision Cooling unit with Green Technologyfeatures such as EC fans for modulation of speed and airflow,digital scroll compressor to improve data center PUE. ProprietyiCOM control system are in place to monitor and controlperformance.Vertiv Containment system to optimize energy consumption byseparating hot & cold aisleComprehensive Fire Protection system with a combination of VeryEarly Smoke Detection System and Active Fire Gas System IG 541which has zero green house effect.Leader in DCIM Magic Quadrant, Nlyte Data Center InfrastructureManager (DCIM) is utilised in the Progenet Data Center toefficiently operate the data center, reduce resource costs (assets,space and energy), and increase data center personnel efficiency.Suprema, a Global Leader in Biometrics and Security Technology,are installed at critical points in the Data Center using highlysecured Facial Recognition and Fingerprint Access systemThe Data Center uses LS Simple Data Cabling System, a leadingplayer in the global cable industry. 2 dedicated pathways forredundancy are connected to every Rack, which comes equippedwith 2 X 6 core Multi mode OM4 Fiber connection and 2 X 3 portUltra Slim Cat6A connectivity to support up to 100m for 100GNetwork Uplink Speed.Comprehensive Electrical System with multiple paths andswitchover, allowing for concurrent maintainability

LAYOUTOF DATA CENTER

SPECIFICATIONSBuilding InformationAddressBuilding InformationMenara Lien Hoe, Tropicana, 47800 Petaling Jaya,Selangor, MalaysiaSingle block 18-storey commercial building and SingleBlock 5-storey parking levels.The building consists of 1 data centre floor and 2 subfloors for the installation of electrical facilities and powerplants.Power Supplies11kV HT power feed from TNB power gridIncoming powerDiverse A&B TNB supply to data center housed inseparated compartmentPower CapacityDual 1.25 MVA Dedicated TransformerTotal Transformer Capacity2.5MVATelecommunication ManholeDiverse fibre trunking from MDF Room to the 2 SeparatedDedicated Meet Me Rooms for TelcosTelecommunicationCarrier NeutralNetwork CapabilityAble to support up to 100G Speed via Dual Fiber pathwayand Cat6A pathway for each rackAntenna, Wireless or Microwave EquipmentSpace at RooftopAvailableSite SpecificationData Center Space @ 4th Floor7,000 sq ftGround Floor Space1,700 sq ftBuilding Floor InformationFloor Height3.8 meter, slab to slabFloor Load5 KN per square meterData Centre SpecificationCritical Load Power Density5KW Per rackCooling Density120 watts per sq ft

Rack Arrangement/ Space ConfigurationHot aisle and cold aisle configuration:Cold Aisle Spacing: 1,200mmHot Aisle Spacing: 1,000mmCritical Load Power Distribution1 x primary and 1 x redundant final sub-circuits fromseparate PDU within the data centreLighting500lux light density at the raised floor levelRaised Floor SystemGross Raised Floor Area Per Floor6,000 square feetUsable Raised Floor Area5,500 square feetRF Height300mm raised floor heightRF TypeHPL Steel Cement rigid grid systemConcentrated Load4.5 kNUniform Load12 K-N per square meterUnderfloor InsulationThermal isolation Trocellin polyethlene foamCeilingAluminium Composite Ceiling Panel for data centre areasPartitionsLight Weight Brick Wall for each dedicated fire zoneCabling SystemTwo Parallel paths of overhead Fiber Runner for fibercabling system & infrastructure and cable basket for UTPcabling system & infrastructureUninterruptible Power Supply (UPS) SystemUPS SystemTrue-online Double Conversion UPS with efficiency up to99.1% housed in Separated compartmentsStatic UPS Capacity2 x 600kVA Modular UPSTotal Static UPS Capacity1200kVAUPS Battery Autonomy10 minutes at full loadUPS Redundancy2N 1 configurationUPS External BypassProvided

Clean EarthClean earth point is provided to each rack location underthe raised floor which is linked to a dedicated Clean earthPit located at ground floorPower Distribution Unit (PDU)PDU ConfigurationEach PDU receives one 415Vac protected power supplyfrom 2 different UPS output panel within the data centre.Each PDU is connected to the Main UPS SB with dedicatedDigital Power Meter, KWH Meter. The power metersprovide the electrical consumption reading of the PDUthrough the KWH meter or digital meter via Data CenterInfrastructure Management System (DCIM) interfacePDU Capacity150KVACircuit per CabinetFor 2N configuration1 x primary and 1x redundant final circuit from separatePDU.Circuit ProtectionEach final circuit is individually protected by a MCB atPDU.Circuit Breaker SizesSingle phase 20A, 32A single phase and three phasepower supplies are available from the PDU. Breakers arehot swappableAC voltage at Cabinet Level240V/ 50 Hz , 415V/ 50 HzEmergency Power Generator (EPG)650KVA backup diesel generatorFuel TankExternal fuel tanks able to support EPG plant for 12 hoursat full loadSupported ServicesData centre, CRACs, chillers, lighting and general serviceswithin data centre areasCooling SystemAir cooledCRAC SystemRow based Computer room Inverter type air conditionunitCRAC RedundancyRow Based Cooling system in the same farm area areconfigured in N 1 and equipped with an automaticchangeover controllerCRAC Power RedundancyEach CRAC is connected to two power sources fromdifferent ACMV panel via Automatic Transfer Switch (ATS)CRAC System SupportCRAC system is supported by EPG Plant

Temperature Control22 Degree /- 3ºHumidity Control50 RH /- 10 RHContainmentCold aisle containment is available for all racking area c/wsky light ceilingWater Leakage DetectionWater leak detection system is installed in data centreareasLeak Detection TypeResistive leak tape (cable) monitoring leakage at anypoint along the perimeter of the data centre areaFire Detection and Suppression SystemFire SuppressionInert Gas IG-541 fire suppression system is installed in thedata centre areasIG-541IG-541 Gas suppression system is installed above andunder the raised access floor in the data centre areasFire Alarm and Detection SystemTwo stages of alarms are implemented for heat andsmoke detection systemVery Early Smoke Detection Apparatus(VESDA) SystemVESDA system is implemented in the entire data centerarea and operated independently from the fire alarmsystem. VESDA is designed to provide 2 stage alarm.Security24 x 7 on site securityMulti layered security controlsFacial and Biometric access control system at all datacentre entrances and exits24 x 7 CCTV monitoring backed by digital recordings up to90 days storage at multiple sitesData Center Infrastructure ManagementData Center Infrastructure Management System (DCIM)to monitor and control all facilities within data centre– Automatic control and monitoring of the environmentalcontrol system– Monitoring of high tension supplies, UPS, Generator,Switchboards, CRAC, Fire Safety, Room temperature &humidity, water leaks, early smoke detectionOn Site Manned Support24 x 7 Service Operation Centre with Display wall tomonitor operation of data center

Leader in DCIM Magic Quadrant, Nlyte Data Center Infrastructure Manager (DCIM) is utilised in the Progenet Data Center to efficiently operate the data center, reduce resource costs (assets, space and energy), and increase data center personnel efficiency. Suprema, a Global Leader in Biometrics and Security Technology,