Residential Section 1 - Lowe's

Transcription

ResidentialSection 1Section Updated 03 / 2010Load CentersQ-Line Circuit Breakers– Product Features and Benefits.1-2PowerMark Gold Load Centers—Product Features and Benefits .1-3PowerMark Gold and Plus Load Centers—Product Number Guides.1-4Q-Line Plug-in Circuit Breakers.1-5Special Purpose Circuit Breakers .1-6PowerMark Gold and Plus Single-Phase Load Centers—Main Lug and Convertible Load Centers.1-9Main Breaker Factory Installed .1-12PowerMark Plus Three-Phase Load Centers—Main Circuit Breakers or Main Lugs Factory Installed .1-14PowerMark Gold Load Centers—Specialty Panels .1-17PowerMark Gold Meter Socket Load Centers .1-18Field Installed Accessories.1-24Wiring Diagrams .1-30Load Centers and Meter Socket Load Centers—Knockouts.1-38Modular MeteringMeter Mod III and Mini Mod III Product Number System.1-43Mini Mod III—Ring Type and Ringless.1-44Mini Mod III—Tenant Main Circuit Breakers.1-45Mini Mod III—Factory Installed Accessories .1-46Mini Mod III—Field Installed Accessories .1-47Meter Mod III—How to Order; Short Circuit Ratings.1-48Meter Mod III—Main Modules,Single-Phase and Three-Phase.1-49Meter Mod III—Factory Installed Accessories.1-52Meter Mod III—Meter Stack Modules,Single-Phase Plus Accessories .1-56Meter Mod III—Meter Stack Modules,Three-Phase plus Accessories.1-59Meter Mod III—Meter Stack Modules,Phase Balancing.1-60Mini Mod III—Enclosure Knockout Dimensions.1-61Meter Mod III—Enclosure Knockout Dimensions.1-62Structured WiringValue Series— Wall Plate Solutions, Wall Mount Solutions,Value 10", 15", 20" and 37" Solutions.1-65Value Series Selector Guide.1-67Rough-in Kits, Cover Kits/Door Kits,Mounting Systems, Telephone Modules .1-68Video Modules—Direct Mount, Shelf Mount, Tray Mount.1-69Data Modules, Computer Networking Modulesand Accessories .1-70Video Cameras, NetworX Security System Kits,Connectors and Terminators, Surge Modules .1-71Power Modules, Demo Kits .1-72Bath Fans, Bath Fan Accessories, Door ChimesProduct Features and Benefits.1-73Bath Fan—Single Units.1-74Bath Fan—Contractor Packs .1-76Accessories, Door Chimes .1-76Publications and Reference: See Section 22 for acomplete list of additional product-related publicationsRev. 1/10Prices and data subjectto change without noticewww.geelectrical.comBuyLog Catalog1-1

ResidentialSection 1Load CentersQ-Line Circuit BreakersReliability and EconomySpecial Purpose Circuit Breakers—PowerMark Gold Main Circuit Breakers—Arc Fault Circuit Interrupter—CB3 Ground Fault Circuit Interrupter—Switching Neutral—HID Lighting Breaker—High Magnetic Breaker—Molded Case Switch—Surge Arrester—TQ BreakerCopper stabs, tin-plated for corrosion resistance,make the connection reliable and permanent.Heat-resistant thermoset cases and covers addstability and structural rigidity.Trips are easy to spot because handles trip to thecenter position.The dedicated calibration screw is cemented (notsimply papered over) to prevent shifting. The result isstable calibration for optimum trip performance.At 1/2”, THQP breakers are half the width of standard breakers, permitting the use of smallerload centers that save money and space in both new construction and service upgrades. Theyfeature the same high-performance design, and meet the same stringent standards as other QLine breakers. Our 1” THQL will remain the breaker of choice for many contractors. In applications where space and cost are not critical, they’re an excellent choice. But when size and moneyare driving considerations, THQP breakers are the smart choice.Enclosed circuitbreakers make iteasy and efficientto install exteriormain breakers.Maximum protectionagainst all-too-commonelectrical fires comesfrom the new technologybuilt into GE’s arc faultcircuit interrupters (AFCIs).With its ability to detectand interrupt arcingcaused by damaged wireinsulation or a frayed extension cord, the AFCI takeshome and family protection to a new, higher level.1-2BuyLog CatalogTHQLSURGE surgearresters are easy toinstall and protect thewhole house – computers, fax machines, televisions, stereos, VCRs andother sensitive electronicequipment – fromdestructive surges.The NEC requires ground fault protection of receptacles outdoors andin garages, bathrooms and spa areas. These ground fault circuitinterrupters eliminate the need for separate GFCI receptacles, protectagainst short circuits and overloads, and prevent shock by detectingvery low levels of current leaks and immediately shutting off power tothe circuit.www.geelectrical.comRev. 1/10Prices and data subjectto change without notice

ResidentialSection 1Load CentersPowerMark Gold Load CentersHighest Quality and ConvenienceOne-piece interiorremoves andreinstalls easilyMain breaker configuration allows top or bottomfeed without modificationPowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obviousand significant advances in design, function and quality.Combination—Exclusive GE lifetime warrantyslotted/Robertson—UL Listed (Panelboards No. 67)square-driveFull-length neutralsspeeds screw—Suitable for Use as Service Entrance Equipment when installedare easier to wire,wiringin accordance with National Electrical Codereducing installation—60 C/75 C Conductor Ratingtime and cost—Single phase, 40-225A, 2-42 circuitsAll holes rated—Main lug models field convertible to main breakerfor 14-4 wire—Main breaker 22kAIC standard - factory installed—All load centers top or bottom feedSteel (not plastic)—Indoor and outdoor rated enclosuresMinimum 100%breaker mounting—Indoor fronts combination surface/flushneutralrail—Copper bus standardterminations—Split neutrals extend the full length of the interior for ease of wiring100% rated—Entire main lug line converts easily to main breakersplit neutral—Combination surface/flush front with spring-reinforced panon each side—Combination slotted/Robertson square-drive screws on neutral,Sturdy copper busground, front and breaker lugsand galvanized box—Front packed in inner carton for added protectionincrease durabilityTie bar may be—Field installable feed-through lugs up to 200Aand reliabilityremoved to split—Straight-through main wiringAccepts GE Q-Line branchneutral/ground—Main breaker is clearly marked and circuit numbers are stampedcircuit breakers, includingon frontGE’s exclusive 1/2" THQPs—Isolated ground bar is available—Compact box maintains optimum wire-bending spaceSafety accessories – convenient and easy to installAccessories and Options—Door lock and handle—Equipment ground kits—Sub-feed and feed-thru lugs—Front filler plates—Handle lock and ties—Hardware kits—Main breaker retainers—Neutral kits—Universal raintight hubsPackaging features comprehensiveselection and application data.Fronts are packed in inner cartonsfor added protection during shipmentand at the job site.—THQLSURGE whole house surge protector—THSACOAX coaxial cable surge protector—THSATEL410 telephone surge protector—Arc fault circuit interrupter breaker, 1- or 2-pole—Ground fault circuit interrupter breaker, 5mA and 30mA—Generator transfer panel – 30A or 60A, indoor or outdoor—GE AC disconnectsA complete family of meter socket load centers — ring styleand ringless, wide and narrow, meter mains, farm panels andmore — deliver specialized solutions for special situations.The PowerMark Goldline includes a widerange of outdoor aswell as indoor units.Main lug load centers offer an economical solution for subpanels and similar applications. Allmain lug units 125A and above convert easily tomain breaker.GE’s residential load centers reach intocommercial applications as well, with riserpanels, auxiliary gutters, three-phase unitswith standard 22kAIC ratings, and all theaccessories needed to complete the job.Publications and Reference: See Section 22 for acomplete list of additional product-related publicationsRev. 1/10Prices and data subjectto change without noticewww.geelectrical.comBuyLog Catalog1-3

ResidentialSection 1Load CentersPowerMark Gold and Plus Load CentersProduct Number GuidesProduct Number Guide for Load Centers(Product number for illustrative purposes only)TM42420CCUBInsert for SpecialsG or T Factory installed ground barB Bottom feed main breakerFL Factory installed feed-through lugsD Optional door for 6-8 circuit panel.(Doors standard on all units 12circuits or greater)GE IdentificationTypeM Main breakerL Main lugLM ConvertiblePL Main lug (Thermoplastic)Insert for PowerMark GoldCU Copper Bus42 Copper Bus Full 42 circuit panelMaximum Number 1" Spaces2, 4, 6 42Enclosure TypeC Combination surface/flushF FlushS SurfaceR OutdoorInsert for 3-Phase 4-WireLoad CentersBus Ampere Rating40 40 Amps70 70 Amps10 100 Amps12 125 Amps15 150 Amps20 200 Amps22 225 Amps30 300 Amps40 400 Amps60 600 AmpsProduct Number Guide for Q-Line Plug-in Circuit Breakers(Product number for illustrative purposes only)THQL11*15GE IdentificationGround Fault/Arc Fault Circuit InterrupterGF 1-pole Ground Fault Circuit Interrupter–5 mAGF1 2-pole Ground Fault Circuit Interrupter–5 mAAF 1- & 2-pole Arc Fault Circuit InterrupterGFEP 1- & 2-pole Ground Fault CircuitInterrupter–30 mAInterrupting RatingH 10kAlCHH 22kAlCX 65kAlCTypeQL 1" plug-inQP 1/2" plug-inQB 1" bolt-onAmpere RatingVoltage1 120/240V2 240VPoles (1, 2, 3)*Omit character for THQP breakers, which are all 120/240V.1-4BuyLog Catalogwww.geelectrical.comRev. 1/10Prices and data subjectto change without notice

ResidentialSection 1Page Updated 02 / 2010Load CentersQ-Line Plug-in Circuit BreakersUL Listed (Molded Case Circuit Breakers No. 489)Federal Government Specification Qualified (WC-375B)60 C / 75 C Conductor RatingQuick Make, Quick BreakBox Type TerminalsQ-Line Plug-in Circuit Breakers SpecificationsBreaker TypeAmpere 0THQL2140THQL32015TQDL21200Wire Size 5012-88-412-88-34-1/02-2/01/0-2501/0-2501Solid or stranded for 14-10 AWGQ-Line Plug-in Circuit BreakersAmpereRatingSingle Pole1152202253035404550Std. Pkg.Type THQP 1/2-inch Module120/240 VacProductList PriceNumberGO-138ATHQP115 20.25THQP120 20.25THQP125 20.25THQP130 20.25THQP135 21.25THQP140 21.25THQP145 21.25THQP150 21.255 cartons of 2010,000AICType THQL 1-inch Module120/240 Vac240 VacProductList PriceProductList PriceNumberGO-138ANumberGO-138THQL1115 20.25THQL1120 20.25THQL1125 20.25THQL1130 20.25THQL1135 21.25THQL1140 21.25THQL1145 21.25THQL1150 21.255 cartons of 10Two-Pole3: Incorporates Internal Common Trip Bar15THQP215 46.00THQL2115 46.0020THQP220 46.00THQL2120 46.0025THQP225 46.00THQL2125 46.0030THQP230 46.00THQL2130 46.0035THQP235 47.75THQL2135 47.7540THQP240 47.75THQL2140 47.7545THQP245 47.75THQL2145 47.7550THQP250 47.75THQL2150 47.7560––THQL2160 47.7570––THQL2170 95.0080––THQL2180 131.0090––THQL2190 131.00100––THQL21100 131.00110––THQL21110 284.00125––THQL21125 284.00Std. Pkg.5 cartons of 105 cartons of 54125––TQDL21125 296.00150––TQDL211504 296.00175––TQDL211754 296.004200––TQDL21200 296.00Std. Pkg.10 cartons of 1Three-Pole3: Incorporates Internal Common Trip . ��–––––––––––––THHQL1115 40.25THHQL1120 40.25THHQL1125 40.25THHQL1130 40.25THHQL1135 41.25THHQL1140 41.25THHQL1145 41.25THHQL1150 41.255 cartons of 10THQL22015 133.00THQL22020 133.00THQL22025 133.00THQL22030 133.00THQL22035 133.00THQL22040 133.00THQL22045 133.00THQL22050 133.00THQL22060 133.00THQL22070 156.00THQL22080 221.00THQL22090 221.00THQL22100 221.00––––5 cartons of 5––––––––THQL32015 165.00THQL32020 165.00THQL32025 165.00THQL32030 165.00THQL32035 165.00THQL32040 165.00THQL32045 165.00THQL32050 165.00THQL32060 165.00THQL32070 216.00THQL32080 245.00THQL32090 245.00THQL32100 245.005 cartons of 31UL Listed as HACR (heating, air conditioning and refrigeration).2UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lightingloads.315-100 amp UL Listed as HACR (heating air conditioning and refrigeration).4Requires four 1-inch spaces.5GO-13822,000AICType THHQL 1-inch Module120/240 Vac240 VacProductList PriceProductList PriceNumberGO-138ANumberGO-138THHQL2115 93.00THHQL2120 93.00THHQL2125 93.00THHQL2130 93.00THHQL2135 97.00THHQL2140 97.00THHQL2145 97.00THHQL2150 97.00THHQL2160 97.00THHQL2170 148.00THHQL2180 210.00THHQL2190 210.00THHQL21100 210.00THHQL21110 686.00THHQL21125 686.005 cartons of �65,000AICType TXQL 1-inch Module120/240 VacProductList PriceNumberGO-138ATXQL1115 74.75TXQL1120 74.75TXQL1125 74.75TXQL1130 74.75––––––––5 cartons of 10THHQL22015 193.00THHQL22020 193.00THHQL22025 193.00THHQL22030 193.00THHQL22035 193.00THHQL22040 193.00THHQL22045 193.00THHQL22050 193.00THHQL22060 193.00THHQL22070 251.00THHQL22080 277.00THHQL22090 277.00THHQL22100 277.00––––5 cartons of 5––––––––TXQL2115 186.00TXQL2120 186.00TXQL2125 186.00TXQL2130 �–––––––5 cartons of 5––––––––THHQL32015 251.00THHQL32020 251.00THHQL32025 251.00THHQL32030 251.00THHQL32035 251.00THHQL32040 251.00THHQL32045 251.00THHQL32050 251.00THHQL32060 251.00THHQL32070 329.00THHQL32080 359.00THHQL32090 359.00THHQL32100 359.005 cartons of 3TXQL32015 348.005TXQL32020 348.005TXQL32025 348.005TXQL32030 ��–––5 cartons of 3References:Accessories PagesAuxiliary Switches and Shunt Trips1-24 thru 1-29BuyLog pages 3-39 thru 3-41.Publications and Reference: See Section 22 for acomplete list of additional product-related publicationsRev. 1/10Prices and data subjectto change without noticewww.geelectrical.comBuyLog Catalog1-5

ResidentialSection 1Load CentersSpecial Purpose Circuit Breakers60 C / 75 F Conductor RatingBox Type TerminalsQuick-Make, Quick-BreakMulti-pole Breakers Incorporate Internal Common TripPowerMark Gold Main Circuit Breakers for use with 150A-225A PowerMark Gold LoadCenters (Includes mounting base)UL Listed.Main Circuit Breaker Kits22,000 AICAmpere RatingProductNumberList QMV150DTHQMV175DTHQMV200DTHQMV225D 259.00 259.00 259.00 259.00 259.00 259.00THQMVXXXDPowerMark Gold Main Circuit Breaker KitFor use with 125A PowerMark Gold load Centers; 22kAIC RMS symmetrical; For bottomfeed, also purchase TRL22 door handle.DescriptionMain Circuit Breaker Kit - Order appropriate THQL10kAIC or THHQL 22kAIC breakers separatelyProductNumberList PriceGO-138MTQMH000 55.50TQMH000Arc FaultUL Listed (Molded Case Circuit Breakers No. 489 ad Arc-Fault Circuit InterruptersNo. 1699).Ampere Rating1-Pole, 120/240 Volts ac1ProductList PriceNumberGO-146A1 Pole, 120/240 Volts ac2ProductList PriceNumberGO-146A2-Pole 120/240 Volts ac1ProductList PriceNumberGO-146A10,000 AIC1520THQL1115AFTHQL1120AF 170.00 20AF 326.00THHQL1115AF2 326.00THHQL1120AF220 Cartons of 1 300.00 300.00THQL2115AFTHQL2120AF 385.00 385.00 500.00 500.00THHQL2115AF 701.00THHQL2120AF 701.0010 Cartons of 122,000 AICStd. Pkg.As of Jan. 1, 2008, 2005 NEC requires combination AFCI.1Branch/feed AFCI compliant with 2002 NEC or earlier2Combination AFCI compliant with 2005 and 2008 NEC and UL1699 (Feb. 2008)Arc FaultCB3 Ground FaultUL Listed (Molded Case Circuit Breakers No. 489 and Ground Fault Circuit Interrupters No.943). Class A (.005 ampere ground fault trip level).Ampere Rating1-Pole, 120/240 Volts acProductList PriceNumberGO-1462-Pole, 120 Volts acProductList PriceNumberGO-14610,000 AIC1520304050THQL1115GFTHQL1120GFTHQL1130GF–– 159.00 159.00 159.00––152030THHQL1115GF 311.00THHQL1120GF 311.00THHQL1130GF 311.0010 cartons of 150GF1 282.00 282.00 282.00 282.00 702.00––––––22,000 AICStd. Pkg.1-6BuyLog CatalogTHQL1120GF10 cartons of 1www.geelectrical.comRev. 1/10Prices and data subjectto change without notice

ResidentialSection 1Load CentersSpecial Purpose Circuit Breakers60 C / 75 F Conductor RatingBox Type TerminalsQuick-Make, Quick-BreakMulti-pole Breakers Incorporate Internal Common TripCB3 Equipment Ground FaultUL Listed (Molded Case Circuit Breakers No. 489 and Ground Fault Circuit Interrupters No.943) 30 milliampere ground fault trip level1-Pole, 120/240 Volts acProductList PriceNumberGO-146Ampere Rating2-Pole, 120 Volts acProductList PriceNumberGO-14610,000 AIC152030THQL1115GFEP 271.00THQL1120GFEP 271.00THQL1130GFEP 271.0010 Cartons of 1Std. Pkg.THQL2115GFEP 481.00THQL2120GFEP 481.00THQL2130GFEP 481.0010 Cartons of 1Switching NeutralUL Listed (Molded Case Circuit Breakers No. 489). 10kAIC RMS symmetrical.Standard 1- or 2-pole automatic breaker plus one fully-rated, non-automatic pole.1-Pole Plus Switching Neutral120/240 Volts acProductList PriceNumberGO-138AAmpere Rating15202530THQL21WY15 74.25THQL21WY20 74.25THQL21WY25 74.25THQL21WY30 74.255 cartons of 5Std. Pkg.2-Pole Plus Switching Neutral120/240 Volts acProductList PriceNumberGO-138ATHQL31WY15 111.00THQL31WY20 111.00THQL31WY25 111.00THQL31WY30 111.005 cartons of 3THQL21WY30"HID" LightingUL Listed as HID. HID breakers have been designed to handle the current and voltagespikes that result when gaseous discharge lamps, including fluorescent and HID lamps,are switched on and off.1-Pole, 120/240 Volts acProductList PriceNumberGO-138AAmpere Rating2-Pole, 120/240 Volts acProductList PriceNumberGO-138A10,000 THHQL1115HID1 49.50THHQL1120HID1 49.50THHQL1130HID 49.505 cartons of 10 26.00 26.00 26.00THQL2115HIDTHQL2120HIDTHQL2130HID 57.00 57.00 57.00THQL2120HID22,000 AICStd. Pkg.THHQL2115HID 119.00THHQL2120HID 119.00THHQL2130HID 119.005 cartons of 51UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting loads.High MagneticUL Listed (Molded Case Circuit Breakers No. 489). 10kAIC RMS symmetricalHigh short circuit setting suitable for circuits with inherent high-inrush load currents.Ampere Rating152025304050Std. Pkg.1-Pole, 120/240 Volts acProductList QL1130HMTHQL1140HMTHQL1150HM5 cartons of 10 26.00 26.00 26.00 26.00 26.75 26.75THQL1140HMPublications and Reference: See Section 22 for acomplete list of additional product-related publicationsRev. 1/10Prices and data subjectto change without noticewww.geelectrical.comBuyLog Catalog1-7

ResidentialSection 1Load CentersSpecial Purpose Circuit Breakers60 C / 75 F Conductor RatingBox Type TerminalsQuick-Make, Quick-BreakMulti-pole Breakers Incorporate Internal Common TripMolded Case SwitchesUL Listed (Molded Case Switches No. 1087). Without overload or short circuit protection.2-Pole3-PoleProductNumberList PriceGO-138AProductNumber60100TQL21Y60TQL21Y100 51.00 147.00––60100TQL22Y60 139.001TQL22Y100 235.0015 cartons of 5Ampere RatingList PriceGO-138120/240 Volts ac––TQL21Y100240 Volts acStd. Pkg.TQL32Y60 177.00TQL32Y100 266.005 cartons of 31GO-138Sub-feed and Feed-thru LugsUL ListedFor use in load centers to economically supply power to a subpanel.PolesAmpere RatingProductNumberList LK21502THLK22002THLK32253 77.00 107.00 137.00 158.00 250.00THLK21252For use with PowerMark Gold load centers only3For use with three-phase load centers only. Includes mounting base.TQ Circuit Breakers3/4" UL Classified Circuit Breakers for use in *Square D *QO Load Centers.10 kAIC RMS symmetrical1-PoleAmpere Q1140TQ1150–Std. Pkg.2-PoleList PriceGO-138Q 20.25 20.25 20.25 20.25 20.25–1 carton of 10ProductNumberList PriceGO-138QTQ2115TQ2120TQ2130TQ2140TQ2150TQ2160 46.00 46.00 46.00 46.00 46.00 46.00THLK21501 carton of 5Interlocking Circuit Breakers for use in PowerMark Gold Generator PanelsTwo breakers required for interlocking.2-PoleAmpere RatingProductNumberList PriceGO-138A3060THQL2130GENTHQL2160GEN 238.75 238.75TQ1120*Square D is a registered trademark of SNA Holdings, Inc.*QO is a registered trademark of the Square D Company.1-8BuyLog Catalogwww.geelectrical.comRev. 1/10Prices and data subjectto change without notice

ResidentialSection 1Load CentersPowerMark Gold and Plus Load CentersMain Lug and Convertible Load CentersProduct Features—UL Listed (Panelboards No. 67)—60 /75 C Conductor Rating—Suitable for Use as Service Entrance Equipment when Installedin Accordance with the National Electrical Code—22kAIC RMS symmetrical, Except Where Noted—6-42 circuit devices UL Listed for bottom mounted lugs byinstalling complete unit (box, interior and front) upside down.—For a listing of CSA Listed load centers, visitwww.geelectrical.com.TLM2020CCU and TPL412RSingle-Phase, Three-Wire, 120/240 Vac, Main Lugs Factory Installed (TLM units convertible to main breaker),Indoor (NEMA 1) EnclosureMain1 Pole,Ampere1”Rating Spaces4027022 Pole,1”Spaces1 Pole,1/2”Spaces2 face 6241024Surface lush FrontFlush FrontFlush FrontSurface FrontSurface FrontSurface FrontFlush FrontFlush FrontFlush FrontSurface FrontSurface FrontSurface ionFlush/SurfaceFrontFeed Type1TopBottomTopBottomTopBottomBoxNumberMain Wire Size(AWG/kcmil)Cu-AlEquipmentGround KitProductNumberList PriceGO-137D1A14-4TGK4 (order separately)TL240SCU1 41.75TGK4 (order separately)TL270SCU1 50.25TL412C1,2,6 57.251A6-32A1-2/0TGL1 (order separately)TopBottom2A1-2/0TGL1 installedTL412CT1,2,3,6 ttomTopBottomTopBottomTopBottomTopBottom21-2/0TGL1 (order separately)TPL412C1,2,3,6 67.25TGL1 installedTPL412CT1,2,3,6 78.25TGK12 (order separately)TLM612FCU4 85.00TGK12 (order separately)TLM612FCUD4 85.00TGK12 (order separately)TLM612FCUDG4TGK12 (order separately)TLM612SCU4 85.00TGK12 (order separately)TLM612SCUD4 85.00TGK12 (order separately)TLM612SCUDG4 105.00TGK12 (order separately)TLM812FCU4 113.00TGK12 (order separately)TLM812FCUD4 113.00TGK12 (order separately)TLM812FCUG4 113.00TGK12 (order separately)TLM812SCU4 113.00TGK12 (order separately)TLM812SCUD4 113.00TGK12 installedTLM812SCUDG4 133.00TLM1212CCU8,9 143.00TLM1212CCUG8,9 156.00TLM1212C245 300.00TLM1212C24G5 16-16-16-16-16-16-16-1186-2/0TGK12 (order separately)TGK24 (order separately)TopBottom186-2/0TGK24 installedTopBottom46-2/0TGK12 (order separately)TGK24 (order separately)TopBottom46-2/0TGK24 installed 105.00This table continued on next pagePublications and Reference: See Section 22 for acomplete list of additional product-related publicationsRev. 1/10Prices and data subjectto change without noticewww.geelectrical.comBuyLog Catalog1-9

ResidentialSection 1Load CentersPowerMark Gold and Plus Load CentersMain Lug and Convertible Load CentersSingle-Phase, Three-Wire, 120/240 Vac, Main Lugs Factory Installed (TLM units convertible to main breaker),Indoor (NEMA 1) EnclosureMain1 Pole,Ampere1”Rating Spaces2 Pole,1”Spaces1 Pole,1/2”Spaces2 inationFlush/SurfaceFrontBoxNumberMain Wire ound KitProductNumberList PriceGO-137D6-2/0TGK12 (order separately)TGK24 (order separately)TLM1612CCU5 185.0076-2/0TGK24 (order separately)TGK32 (order separately)TLM2412CCU5 242.00TopBottom81-3/0 (Cu),2/0-3/0 (Al)TGK32 (order separately)TLM2015CCU7 255.00TopBottom76-250TGK32 (order separately)TLM1620CCU7 192.00TopBottom76-250TGK32 installedTLM1620CCUG7 216.00TopBottom86-250TGK24 (order separately)TGK42 (order separately)TLM2020CCU7 245.00TopBottom86-250TGK42 installedTLM2020CCUG7 277.00TopBottom91-3/0 (Cu),2/0-3/0 (Al)TGK24 (order separately)TLK32 (order separately)TLM2420C427 450.00TopBottom111-250 (Cu),2/0-250 (Al)TGK32 and TLK20(order separately)TLM3220C427 477.00TopBottom116-250TGK32 (order separately)TLM3220CCU7 368.00TopBottom136-250TGK42 (order separately)TLM4020CCU7 477.00TopBottom141-300 (Cu),2/0-300 (Al)TGK42 (order separately)TLM4220CCU7 550.00TopBottom141-300 (Cu),2/0-300 (Al)TGK42 (order separately)TLM4222CCU7 578.00Feed Type1No door210 kAIC3125 amp maximum branch capacity.4For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp max.5For main breaker, order TQMH000. See page 1-24. Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page 1-5.6GO-137A (PowerMark Plus Load Centers)7For main breaker, order THQMVXXXD circuit breaker from page 1-6.8For main breaker, order THQLRK3 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp max.9No lock provision available. Use compatible load center with the suffix C24 with a TDL106 for locking provision.Note: See page 9-15, AL Series Lighting Panelboards as replacements for 300-600A load centers.1-10BuyLog Catalogwww.geelectrical.comRev. 1/10Prices and data subjectto change without notice

ResidentialSection 1Load CentersPage Updated 12 / 2009PowerMark Gold and Plus Load CentersMain Lug and Convertible Load CentersSingle-Phase, Three-Wire, 120/240 Vac, Main Lugs Factory Installed (TLM units convertible to main breaker),Outdoor (NEMA 3R) Enclosure1Main1 Pole,Ampere1”Rating Spaces2 Pole,1”Spaces1 Pole,1/2”Spaces2 peBoxNumberMain Wire Size(AWG/kcmil)Cu-AlEquipmentGround 1-2/01-2/01-2/0TGK4 (order separately)TGK4 (order separately)TGL1 (order separately)TGL1 installedTGL1 (order separately)TGL1 (order ,3,7TL412R22,3,7TPL412R2,3,4,7 85.00 98.00 108.00 118.00 108.00 118.00TopR11-2/0TGL1 installedTPL412RT2,3,4,7 128.00TGK12 (order separately)TGK12 (order separately)TGK12 (order separately)TGK12 (order separately)TGK24 (order separately)TGK24 (order separately)TGK32 (order separately)TGK24 (order separately)TGK32 (order separately)TGK24 (order separately)TGK32 (order separately)TGK24 (order separately)TGK42 (order separately)TGK24 (order ,6,8TLM1212RCU2,6,8 111.00 169.00 186.00 226.00TLM2412RCU2,6,8 333.00TLM2415RCU2,8 364.00TLM1220RCU2,8TLM1620RCU2,8TLM2020RCU2,8 231.00 293.00 335.00TLM2420R42B8 560.00TGK32 (order separately)TGK42 (order separately)TGK42 (order separately)TLM3220RCU2,8TLM4020RCU2,8TLM4222RCU2,8 525.00 626.00 0101418243240TopTopTopR5R5R61-3/0 (Cu),2/0-3/0 FrontThermoplasticFront1-250 (Cu),2/0-250 (Al)R7 1-250 (Cu), 2/0-250 (Al)R86-250R81-300 (Cu),2/0-300 (Al)ProductNumberList PriceGO-137D140-225 amp single-phase devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.2No door310 kAIC.4125 amp maximum branch capacity.5For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp max.6For main breaker, order TQMH000. See page 1-24. Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page 1-5.7GO-137A (PowerMark Plus Load Centers)8For main breaker, order THQMVXXXD circuit breaker from page 1-6.Note: See page 9-15, AL Series Lighting Panelboar

—Arc fault circuit interrupter breaker, 1- or 2-pole —Ground fault circuit interrupter breaker, 5mA and 30mA —Generator transfer panel - 30A or 60A, indoor or outdoor —GE AC disconnects Packaging features comprehensive selection and application data. Fronts are packed in inner cartons for added protection during shipment and at the .