TFP10 TFP6 TFP4 55 CFM (93 M /hr.) - NVent

Transcription

Fresh Air Enclosure Cooling Filter FansTFP Side-Mount FansTFP10215 CFM(365 m3/hr.)TFP6140 CFM(238 m3/hr.)TFP455 CFM(93 m3/hr.)INDUSTRY STANDARDS UL 508A Component Recognized; File No. E61997TFP# Models: Type 1TFP# UL 12 Models: Type 12 CSA certified (fan only)CE APPLICATION I ndustrial automation Automotive assembly Package handling equipment Food and beverage process controlls Wind energy systemsSPECIFICATIONS FEATURES 1 ooling Fan Package includes fan, air filter, composite air plenum,Cfinger guard and grille E xhaust Package includes air filter, filter retainer with integralfinger guard and grille EMC Upgrade Kit includes a grille standoff collar and a specialEMC shielding grille Reliable cooling for enclosures with limited space requiringsimple filtered airflow for basic cooling 24 VDC, 115 VAC and 230 VAC options available Washable foam (Type 1) or disposable (Type 12) filter in fanThermal Management ynamically-balanced fan impellers molded from polycarbonateDmaterial 4 -in. fan is thermally protected and uses permanently-lubricatedball bearings 6 - and 10-in. fans have ball bearing construction and splitcapacitor motors that are thermally protected to avoid prematurefailure Fans have lead wires for power connection with ends stripped 1/2in. (12 mm) All mounting hardware and installation instructions are furnishedSpec-00306 O ree airflow from 45 CFM (76 m 3/hr.) to 215 CFM (365 m 3/hr.)F Maximum operating temperature 158 F / 70 C Engineered for 50,000 hours of continuous operation withoutlubrication or service (a monthly maintenance schedule isrecommended to ensure optimal cooling performance)FINISH tainless steel grilles have brushed finish.S ABS composite grille is black.ACCESSORIESTFP Exhaust GrillesTFP Optional Grilles and Replacement FiltersTFP EMC Upgrade KitSUBJECT TO CHANGE WITHOUT NOTICEnVent.com/HOFFMAN

Fresh Air Enclosure Cooling Filter FansPerformance Data TFP4 ModelsELECTRICAL DATARated VoltageFrequency (Hz)Nominal Current Maximum @ 50/60 Hz(Amps)Power Consumption Maximum @ 50/60 Hz (Watts)Power ConnectionCATALOG NUMBERSComposite Type 1Stainless Steel Type 1Free Airflow @ 50/60 Hz (CFM)*Free Airflow @ 50/60 Hz (m3/hr.)*CATALOG NUMBERSComposite Type 12Free Airflow @ 50/60 Hz (CFM)*Free Airflow @ 50/60 Hz (m3/hr.)*UNIT CONSTRUCTIONNoise SIL @ 50/60 Hz (dBA)Maximum Operating Temperature ( F/ C)Unit Dimensions - H x W x D (in./mm)Cutout Dimensions - H x W (in./mm)Weight (lb./kg)EXHAUST GRILLE CATALOG NUMBERSComposite Type 1Stainless Steel Type 1Composite Type 1224 VDC115 VAC50/60.26/.2117/15Stripped Leadwires.358.4230 TFP42UL1221/2536/426537/41158/706.29 x 7.37 x 2.65/160 x 187 x 675.66 x 5.66/144 x *CFM with single exhaust grille installed.7)3 0RGHOV ; % &. 9,(:6,'( 9,(:7(3 (; 867 *5,//( ) 1 *5,//(287/,1(&87287 ',0(16,216 ([KDXVW JULOOH LQFOXGHG ZLWK IDQ SDFNDJHnVent.com/HOFFMANPH 763.422.2211Spec-00306 OThermal Management2

Fresh Air Enclosure Cooling Filter FansPerformance Data TFP6 ModelsELECTRICAL DATARated VoltageFrequency (Hz)Nominal Current Maximum @ 50/60 Hz(Amps)Power Consumption Maximum @ 50/60 Hz (Watts)Power ConnectionCATALOG NUMBERSComposite Type 1Stainless Steel Type 1Free Airflow @ 50/60 Hz (CFM)*Free Airflow @ 50/60 Hz (m3/hr.)*CATALOG NUMBERSComposite Type 12Free Airflow @ 50/60 Hz (CFM)*Free Airflow @ 50/60 Hz (m3/hr.)*UNIT CONSTRUCTIONNoise SIL @ 50/60 Hz (dBA)Maximum Operating Temperature ( F/ C)Unit Dimensions - H x W x D (in./mm)Cutout Dimensions - H x W (in./mm)Weight (lb./kg)EXHAUST GRILLE CATALOG NUMBERSComposite Type 1Stainless Steel Type 1Composite Type 1224 VDC115 VAC50/60.45/.3636/32Stripped Leadwires.8821.1230 50/6085/102TFP62UL1250/6085/10262.550/56158/707.80 x 8.87 x 3.75/198 x 225 x 957.16 x 7.16/182 x *CFM with single exhaust grille installed.7)3 0RGHOV ; % &. 9,(:&87287 ',0(16,216 ) 1 *5,//(287/,1(6,'( 9,(: ([KDXVW JULOOH LQFOXGHG ZLWK IDQ SDFNDJH3Thermal ManagementSpec-00306 OSUBJECT TO CHANGE WITHOUT NOTICEnVent.com/HOFFMAN

Fresh Air Enclosure Cooling Filter FansPerformance Data TFP10 ModelsELECTRICAL DATARated VoltageFrequency (Hz)Nominal Current Maximum @ 50/60 Hz(Amps)Power Consumption Maximum @ 50/60 Hz (Watts)Power ConnectionCATALOG NUMBERSComposite Type 1Stainless Steel Type 1Free Airflow @ 50/60 Hz (CFM)*Free Airflow @ 50/60 Hz (m3/hr.)*CATALOG NUMBERSComposite Type 12Free Airflow @ 50/60 Hz (CFM)*Free Airflow @ 50/60 Hz (m3/hr.)*UNIT CONSTRUCTIONNoise SIL @ 50/60 Hz (dBA)Maximum Operating Temperature ( F/ C)Unit Dimensions - H x W x D (in./mm)Cutout Dimensions - H x W (in./mm)Weight (lb./kg)EXHAUST GRILLE CATALOG NUMBERSComposite Type 1Stainless Steel Type 1Composite Type 12115 VAC.58/.7064/80230 VAC50/60Stripped FP102UL1263/75107/12754/61167/7554/61167/7511.81 x 12.99 x 5.25/300 x 330 x 13311.16 x 11.16/283 x 28312.0/5.4411.4/5.17TEP10TEP10SSTEP10UL12*CFM with single exhaust grille installed.7)3 0RGHOV 7(3 (; 867 *5,//( ) 1 *5,//(287/,1(6,'( 9,(:% &. 9,(:&87287 ',0(16,216 ([KDXVW JULOOH LQFOXGHG ZLWK IDQ SDFNDJHnVent.com/HOFFMANPH 763.422.2211Spec-00306 OThermal Management4

Fresh Air Enclosure Cooling Filter FansTFP Exhaust GrillesNominal FanSizeCATALOG NUMBERSTEP4 ModelsTEP4TEP4SSTEP4UL12TEP6 ModelsTEP6TEP6SSTEP6UL12TEP10 ModelsTEP10TEP10SSTEP10UL12TFP Optional Grilles and Replacement FiltersCATALOG NUMBERS4-inch Fan ModelsTG4SSTG4BAFLTR4AFLTR4ALTFLT4UL126-inch Fan ModelsTG6SSTG6BAFLTR6AFLTR6ALTFLT6UL1210-inch Fan 01010Optional grilles offer the choice of stainless steel or blackABS plastic. These grilles replace the standard RAL 7035 graycomposite or stainless steel grilles on both fan and exhaustpackages. Standard replacement filters are washable foam (Type1) or disposable (Type 12). To maintain UL Type 12 rating on theenclosure, UL Type 12 filters must be used on the fan package inlet.Washable aluminum filters are also available. Aluminum filters arecompatible with Type 1 systems only.Type 12 air filters are not washable.DescriptionFits Fanand ExhaustNominal SizeFits Fanand ExhaustGrill Size (in./mm)Brushed stainless steel grille4Black ABS plastic grille4Type 1 filter replacement (5/package)Aluminum filter replacement (5/package)Type 12 filter replacement (5/package)4446.29 x 7.31 x .81160 x 186 x 216.29 x 7.37 x .81160 x 187 x 21———Brushed stainless steel grille6Black ABS plastic grille6Foam filter replacement (5/package)Aluminum filter replacement (5/package)UL 12 filter replacement (5/package)666Brushed stainless steel grille10Black ABS plastic grille10Foam filter replacement (5/package)Aluminum filter replacement (5/package)UL 12 filter replacement (5/package)a1010107.80 x 8.81 x .75198 x 224 x 197.80 x 8.87 x .49198 x 225 x 12———11.81 x 12.92 x .75300 x 328 x 1911.81 x 12.99 x .75300 x 330 x 19———Replacement filter for Type 12 fan package only (models TFF UL12). For Type 12 exhaust package use replacement filter AFLTRX.Filters fit all fan and exhaust packages according to their size.5Thermal ManagementSpec-00306 OSUBJECT TO CHANGE WITHOUT NOTICEnVent.com/HOFFMAN

Fresh Air Enclosure Cooling Filter FansTFP EMC Upgrade KitCATALOG NUMBERS4-inch Fan ModelsT4EMC6-inch Fan ModelsT6EMC10-inch Fan ModelsT10EMCFits CoolingFan PackageFits ExhaustGrilleTFP42TEP4TFP62TEP6TFP102TEP10With the addition of this kit, the cooling fan and exhaust packagesare upgraded to provide EMC (electromagnetic compatibility)protection. Consult Hoffman for shielding effectiveness (dBattenuation vs. frequency).Separate kits must be installed on both the inlet and outlet. Coolingfan and exhaust package must be ordered separately. EMC upgradekit will not work with stainless steel grille option.nVent.com/HOFFMANPH 763.422.2211Spec-00306 OThermal Management6

Free airflow from 45 CFM (76 m3/hr.) to 215 CFM (365 m3/hr.) Maximum operating temperature 158 F / 70 C Engineered for 50,000 hours of continuous operation without lubrication or service (a monthly maintenance schedule is recommended to ensure optimal cooling performance) Finish Stainless steel grilles have brushed finish.