MVS UVHCMVSUVHCREVISION: EEFFECTIVE: 11/2020TMUVC GERMICIDAL DUAL HEPA FILTRATION UNITPATENTS PENDINGLABORATORY TESTED! Dual UVC GermicidalSourcesPROVENto remove 99.9%of airborne virus particles! Dual HEPA FiltrationMERV 17 (True HEPA)up to 99.97% @ 0.3 Micron Dual Carbon FiltrationRemoves 99.5% of virusparticles in 120 SECONDSSafety Listed to meet A17.5Elevator Code Requirements!Based on 250 Cubic Foottest chamber (70” x 70” x 88” H)See Microbiological Laboratory report for details5018183Conforms to: ASME A17.5 (2019)Conforms to: UL508 (2018)Certified to: CSA B44.1 (2019)Shown with end panel partially removed MVS-UVHC by Man-D-TecFOR NEW AND EXISTING ELEVATOR CABSM V S -U V H CPatent Pending, Ultra Performance, Dual UVC Germicidal & Dual HEPAfiltration unit. Built specifically for elevators and PROVEN to remove99.9% of airborne virus AND bacteria particles. This unit features a3-speed high performance sealed ball bearing motor. The “squirrel cage”blower wheel ensures maximum air flow and quiet operation. Blowspurified air down into the cab.TM23.5012.0017.2518.78TOP VIEWProprietary, fully automatic UV performance monitoring system ensuresthe dual UVC Germicidal unit is performing at peak levels and has LEDindicators for each UV source, along with audible notification when systemneeds attention.COP remote mounted UV status indicators are available. This allowspassengers to visually see that the system is operating, giving themconfidence that their safety is a high priority.FOR OPTIONS SEE15.25SIDE VIEWACCESSORIESManufacturing Location:Man-D-Tec, Inc.8175 E. Paradise LaneScottsdale, AZ USAMADE IN USA OF US & IMPORTED PARTS5018183EPA Est. No. 98546-AZ-1CARB certifiedMeets California ozone emissions limitsVENTILATION / FANSRemoves 97.9% of virusparticles in 60 SECONDS

MVS UVHCMVSUVHCREVISION: EEFFECTIVE: 2 AluminumDIMENSIONS17.25” x 23.50“ and 15.25” HeightAdaptor INCLUDED!Call for fan grille optionsVENTILATION / FANSSCREEN GUARDRATINGSFEATURES5018183Conforms to: ASME A17.5 (2019)Conforms to: UL508 (2018)Certified to: CSA B44.1 (2019)Approved for ELEVATORS!TESTED TO A17.5ELEVATOR CODES!!Fan Unit(MVS-OE)Included & AttachedELEVATOR CONTROL,ELEVATOR ACCESSORYE329545WiringOverall Dimensions10.20” x 6.80” RectangularCutout HoleOR9.75-11.75” Diameter (using included adaptor)Compatible with EXISTINGfan cutouts 9.75” - 11.75”Intake and outlet finger guards are pre-installedInput: 120 VAC, 60Hz, 3.1AOptional Emergency Power Unit AvailableUV-C Lamps: DUAL 13 Watt, High Performance (26 Watts total) Our ETL Authorization to Mark document is included with every unit, proving theENTIRE unit meets A17.5 code requirements (and electrical safety requirements) Blows purified air down INTO the cab and OUT through the vent slots, helping toreduce the risk of pulling particles upward from the floor Compatible with EXISTING fan hole cutouts from many manufacturers Dual UVC Germicidal sources & Dual HEPA filtration True HEPA, MERV 17, up to 99.97% @ 0.3 microns - the gold standard of filtration Dual Carbon Filtration Fully automatic UVC Germicidal performance monitoring system Visual AND audible notification if the UV system needs attention Automatic shut-down safety circuit when filter frames are removed High performance fan unit for rapid air changes Includes brushed stainless wall plate with adhesive backing (to notify passengersthat this system has been installed and they are being protected) Optional, remote mount real-time COP LED indicators give passengers confidenceof knowing the Dual UVC Germicidal system is operational Meets California ozone emissions limits. CARB CertifiedMATERIAL16 GA Steel with black powder coat finishMOTOR SPEEDThree speed, High PerformanceMOTOR CONSTRUCTIONSealed Ball BearingBLADESquirrel cage blower wheelCONNECTIONTerminal block for simple 1, 2, or 3 speed wiringMAN-D-TEC, INC.8175 E. PARADISE LANESCOTTSDALE, AZ 85260 MAN D TEC 2020TMP. 480.998.0325F. 480.998.03181.800.944.6263WWW.MANDTEC.COM

UVHC DUCT KITREVISION: BEFFECTIVE: 9/2020UVHC DUCT KITACCESSORIES FLEX DUCT OPTIOPTIONPATENTS PENDINPENDINGGreat for mounting in tight spaces!MVS-UVHC Not IncludedShown for demonstration purposesIncluded adaptorattaches to most existingfan cutoutcuto holesAn option to give you more “FLEXIBILITY”FOR CAR TOPS WITH LIMITED SPACENow offering an alternate way to mount our MVS -UVHC on car tops with limited space Allows for the base fan unit to be mounted remotely from the normal fan cutout hole Perfect for situations where the existing fan is located under the crosshead High Visibility hose for increased safety Metal adaptor that changes the fan outlet from rectangular to 6”D round Five feet (5’) of six inch (6”) diameter Spring Steel Reinforced flexible hose (UL94V-0 Rated) Metal conversion adaptor which mounts to existing fan cutout hole and converts to accept hose Assembly cluded Items:

AUTHORIZATION TO MARKThis authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s)Covered section when made in accordance with the conditions set forth in the Certification Agreement and ListingReport. This authorization also applies to multiple listee model(s) identified on the correlation page of the ListingReport.This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may beapplied only at the location of the Party Authorized To Apply Mark.Applicant:Man-D-Tec, Inc.Manufacturer:Man-D-Tec, IncAddress:8175 E. Paradise LaneScottsdale, AZ 85260.Address:8175 E. Paradise LaneScottsdale, AZ 85260.Country:Contact:Phone:FAX:Email:USADalton Mandy,Terry n@Mandtec.comMDT@Mandtec.comParty Authorized To Apply Mark:Report Issuing Office:Control Number:5018183Email:USADalton Mandy,Terry omSame as ManufacturerLake Forest, CAAuthorized by:for L. Matthew Snyder, Certification ManagerThis document supersedes all previous Authorizations to Mark for the noted Report Number.This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability arelimited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasionedby the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark isrestricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service mustfirst be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with theagreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.Intertek Testing Services NA Inc.545 East Algonquin Road, Arlington Heights, IL 60005Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672Elevator and Escalator Electrical Equipment [ASME A17.5:2019 Ed.6]Standard(s): Elevator and Escalator Electrical Equipment [CSA B44.1:2019 Ed.6]Industrial Control Equipment [UL 508:2018 Ed.18]Product:Electrical Ventilator for ElevatorsBrand Name: Man-D-TecModels:MVS-UVHC.ATM for Report 104390472LAX-002Page 1 of 1ATM Issued: 12-Aug-2020ED 16.3.15 (20-Apr-17) Mandatory

MAN-D-TEC, INC.EFFICACY TEST REPORTSCOPE OF WORKNon-standardized Test Method: Microbial Reduction Rate TestPRODUCTMVS-UVHCDual UV-C Germicidal & Dual HEPA Filtration Elevator Fan UnitREPORT NUMBER104373902COL-001ISSUE DATE10-AUG-2020PAGES 6DOCUMENT CONTROL NUMBERGFT-OP-10h (6-July-2017) 2020 INTERTEK

MAN-D-TEC, INC.Intertek Report: No: 104373902COL-001MICROBIOLOGICAL PERFORMANCE TEST REPORTSECTION 1 EFFICACY STUDY SUMMARYMAN-D-TEC, INC.8175 E. Paradise LaneScottsdale, AZ 85260Project No.G104373902SampleDual UV-C Germicidal & Dual HEPA Filtration ElevatorProductFan UnitModelMVS-UVHCProceduralEngineerNicholas UngerReviewerLee MoomawDates Tested8/03/20 – 8/07/20Report Date8/10/20StandardNon-standardized Test Method: Microbial Reduction Rate TestTesting FacilityIntertek Microbiological Laboratory1717 Arlingate Ln.Columbus, OH 43228United StatesClientSECTION 2 TEST PROCEDUREA room was constructed measuring 88”H X 70” W X 70” D 249.5 cu/ft. The test unit was placed in thecenter of the constructed room (Photo 1) and the room sealed. A microbial suspension was thenaspirated into the chamber for 30 minutes. The test unit was turned on the and samples drawn atintervals of 0, 1, 2, 3, 4, 5, 10, 15 and 30 minutes. The process was then repeated without the test unit inthe chamber to provide the natural decay results.Air sampling took place using an SKC BioStage Single-stage impactor for 30 seconds at 12L/min (.424cubic feet/min).Version: 6-July-2017Page 2 of 6GFT-OP-10h

MAN-D-TEC, INC.Intertek Report: No: 104373902COL-001MICROBIOLOGICAL PERFORMANCE TEST REPORTPhoto 1: MVS-UVHC UnitSECTION 3 ORGANISMSOrganism NameOrganism TypeATCC NumberSourcePhi X174 bacteriophagesmall, non-enveloped virus13706-B1Carolina BioscienceEscherichia coliGram negative bacteria11229ATCCSECTION 3 EQUIPMENTEquipment TypeEquipment No.Calibration Due DateMicropipetteCE 25876/12/2021IncubatorCE sion NebulizerRefrigeratorPumpStopwatchAmbient Temperature/RHCE 1882CE 2376CE 2382CE 1149CE 1139CE 1157CE 1137SW015CE 11797/7/2021Verify Before UseFor Reference OnlyFor Reference OnlyFor Reference OnlyFor Reference OnlyFor Reference Only10/22/2020For Reference OnlyVersion: 6-July-2017Page 3 of 6GFT-OP-10h

MAN-D-TEC, INC.Intertek Report: No: 104373902COL-001MICROBIOLOGICAL PERFORMANCE TEST REPORTSECTION 4 MEDIA AND REAGENTSTypeNutrient AgarManufacturerDIFCOLot No9346039Expiration Date10/31/2024PBSFisher19273608/01/2022SECTION 5 SAMPLE ACQUISITIONAcquisition method Shipped to Intertek ColumbusDescription Dual UV-C Germicidal & Dual HEPA Filtration Elevator Fan UnitSerial Number N/AArrival date 7-13-2020Condition NewModel VariousSample Identification No. COL2007090948-001Development Level PrototypePhoto 2: Unit LabelsVersion: 6-July-2017Page 4 of 6GFT-OP-10h

MAN-D-TEC, INC.Intertek Report: No: 104373902COL-001MICROBIOLOGICAL PERFORMANCE TEST REPORTSECTION 6 SUMMARY OF RESULTSOrganism TypeTemperature Min/MaxHumidity Min/MaxOrganism NamePercent Reduction4 MinutesOrganism TypeTemperature Min/MaxHumidity Min/MaxOrganism NamePercent Reduction10 MinutesVirus Reduction (4 minutes)23 C (73 F) / 25 C (77 F)56 % RH / 61 % RHPhi-X17499.9%Bacteria Reduction (10minutes)22 C (71 F) / 25 C (77 F)51 % RH / 58 % RHE. coli99.9%Completed by:Nicholas UngerReviewed by:Lee MoomawTitle:Staff EngineerTitle:Engineering Team LeadSignature:DateSignature10-AUG-2020Version: 6-July-2017Date:Page 5 of 610-AUG-2020GFT-OP-10h

MAN-D-TEC, INC.Intertek Report: No: 104373902COL-001MICROBIOLOGICAL PERFORMANCE TEST REPORTAnnex A: Raw Test DataTest ParameterOrganismSamples (min)ResultsSpeciesATCC No.Challenge Concentration012345101530--Test ParameterOrganismSamples (min)ResultsSpeciesATCC No.Challenge Concentration012345101530--Version: 6-July-2017NaturalDecayResultColiphage φX174(Item # 124425)2.0 x 109TNTCTNTC55TNTC14TNTC6TNTC 1TNTC 1TNTC 1TNTC 1TNTC 1TNTC99.9%Test ResultTest ResultNaturalDecayResultE. coli112298.8 x 108TNTCTNTCTNTCTNTC83283 1 1TNTCTNTCTNTCTNTCTNTCTNTCTNTCTNTCTNTC99.9%Page 6 of 6Units----PFU/mLNo eductionUnits----PFU/mLNo ReductionNo ReductionNo ReductionNo 10h

M ICROBIOLOGICAL PERFO R MANCE TEST REPORT MAN -D -TEC, INC. Intertek Re port: No: 104373902COL -001 Version: 6 -July -20 17 Page 3 o f 6 GFT -OP -10h