Druck Trx II - Transcat

Transcription

TRX IT R XI IPortable documenting calibrator! Simulates and Reads RTD’sand thermocouples! Sources and reads Millivolts, Volts,Milliamps, Ohms and frequency! Measures pressure -14.7 to 10,000 psi! Dual readout: measure and source! Data storage for field calibrations! Data transfer via RS 232 or PCMCIA card

T R XI IPortable documenting calibratorA new standard for portable multifunction calibratorsThe Druck TRX II portable documenting calibrator is theculmination of many years of combined field experience with theDruck and Unomat series of calibrators.This one self-contained, battery powered package simulates andmeasures RTD’s, thermocouples and resistance, as well assourcing and reading milliamps, millivolts, volts and frequency.The rugged design includes an impact resistant enclosure whichis fastened to the carrying case for convenience and safety.Dedicated alphanumeric and documenting keypads surround alarge LCD panel with dual readout and backlight. Connectors forsource and measure are kept separate and a 24V output isprovided for loop power.The TRX II’s extensive measurement capabilities can includepressure measurement by connecting Druck pressure sensorswhich have been digitally characterized to give high accuracy.This highly accurate and easy to use documenting calibratorprovides improved data quality and quicker calibration time sincedata can be uploaded and downloaded via the PCMCIA card orthe RS232 interface.High performance and multi-functionalTypical accuracies:0.01% reading 0.01% FS for mAmeasurement.0.05% FS for pressure measurementMeasure:mA, mV, volts, T/C’s, RTD’s, pressure,ohms, frequency and switch state.Source:mA, mV, volts, T/C’s, RTD’s, ohms andfrequencyRemote pressure sensors: 1 to 10,000 psi including gauge, absoluteand differentialLoop power:24 VdcData storage:1 Mbyte and 2 Mbyte PCMCIA cardsData transfer:RS 232 or PCMCIA cardConnectors for externalpressure sensorDirect connection for T/Ccompensation wiresCold junction compensationat point of contactShoulder strapPCMCIA slot forcard types 1 or 2LCD screen protected by a scratchresistant anti-reflection windowSimple to operateThe combined Druck and Unomat knowledge of customer needs, andinnovative design, results in a high performance, yet easy to operate,multi-function documenting calibrator.The key to the simple operation of the TRX II is the structured menu.Input and output readings are displayed simultaneously for test modessuch as T-I and P-I, allowing quick comparison of the values. Used inconjunction with Linkpak-W calibration software, or Intecal-W databasesoftware, the TRX II will perform automatic calibrations from predefined procedures, calculating and reporting errors to the operatorand storing the results on a PCMCIA card. This intuitive approach,whether used manually or automatically, ensures correct set up for thejob at hand and improves working efficiency and data accuracy.The TRX II provides simple and flexible data transfer to fit in with mostworking practices. Information can be reviewed on screen ortransferred to and from the TRX II using the RS 232 interface.Alternatively, without docking the instrument to a PC, data can betransferred by exchanging PCMCIA cards.The operating system works in several languages and provides scaling,step and ramp features for calibration and maintenance. The TRX II,which includes extensive self-test routines, can be relied upon timeand time again for field calibration in extreme conditions.Backlight key

Multilingual firmware supported by Linkpak-Wcalibration software.Input connectorsRS 232 forData transferNumerical keys forentering valuesCarrying casesecured to TRX IIOutput connectorsUser guide for quickreference in the field

T R XI IApplicationsM U LT I F U N C T I O NP O R TA B L EC A L I B R AT O RThe TRX II has been designed for ease of use while meeting a wide range ofapplication needs including calibration, maintenance and commissioning. Thedual parameter display shows the measured and sourced values in largeclear digits with all applicable information such as the units of measurementand range. With safety in mind, construction of the shoulder strap allowshands free operation while maintaining display visibility.Some of the capabilities! Measure/source mA! Measure/simulate 12 types of T/C! Measure/simulate 9 types of RTD! Measure/source frequency and pulses! Simulate transmitter input and measure transmitter output! Measure/source mV/V! Measure/source resistance! Measure pressure: -14.7 to 10,000 psi! Test switches: captures values on contact changeEasy to operateThe easy to operate menu driven software enables the calibrator to be setup very quickly. Simply scroll through the menus and select theappropriate parameters.Operating and connection errors such as loop resistance mismatch andcold junction temperature sensor absence are reported. The KEYSTROKINGmemory enables instant recall of previously stored user tests.T E M P E R AT U R ESENSORS I M U L AT I O N A N DThe auto step and ramp modes enable a single technician to test andcommission control loops. The calibrator is left to generate a pre-programmedoutput, while the technician checks the signal further down the loop.End to end control loop performance can be checked with one instrument bysimulating a temperature signal at the start of the loop.When troubleshooting apply a three step approach.Step one:Measure the sensor output to confirm correct connectionand operation.Step two:Check and calibrate the transmitter by simulating temperaturesignals and measuring the corresponding mA outputs.Step three:Feed the loop with a mA signal and check wiring andinstrumentation further down the line.LO O PCHECKING

T E M P E R AT U R E T R A N S M I T T E R S I M U L AT I O N A N D C A L I B R AT I O NDirect connection of thermocouple compensation wires eliminates theneed for special connectors and reduces additional cold junction errors.This is the most reliable and accurate method of monitoring cold junctiontemperatures in a portable field calibrator.In calibration mode the display shows all the required information. BothmV and mA values are displayed in F for easy comparison, along withthe calculated error expressed as % of span or reading.The TRX II will simulate the temperature signal to the transmitter to becalibrated and will simultaneously measure and display the output. A 24volt power supply is provided for stand alone operation.The connection of 2, 3 and 4 wire RTD‘s is detected automatically, afeature unique to Druck portable field calibrators.C A L I B R AT I O NFORISO9000Dedicated keys for documenting field calibrations eliminate human errorsand are available as standard. The ’AS FND’ (as found) and ‘AS LEFT’ keysstart the respective procedures for storing calibration data which can berecalled using the ‘VIEW’ key.Optional PCMCIA cards represent the most efficient data transfer media.Docking of the calibrator with the PC is unnecessary as a cardcontaining calibration data can be exchanged for another containing newprocedures/work orders, enabling technicians and calibrators to spendmore time in the field.Data is transferred to the PC from the PCMCIA card or the RS 232interface for analysis, certificate printing and archiving. Exporting facilitiesare provided for wordprocessor and spreadsheet applications or in-housemaintenance systems.

R E M OT EPRESSURESENSORSRemote pressure sensors offer a cost effective meansof expanding the capabilities of the TRX II, for example:Pressure ranges (optional)n Calibration of pressure transmittersn Testing pressure switchesn For differential pressure applicationsGaugeAbsoluteDifferentialn For flow measurement calibrationsThe capability of the TRX II can be extended by addingup to 8 external pressure sensors (connected one at atime). With ranges from 1 to 10,000 psi and all weldedstainless steel and Hastelloy construction, sensors canbe chosen to suit many applications. Remote pressuresensors require a mating cable approximately 4.5 feetin length. One end connection interfaces with theremote pressure sensor electrical input and one endmates with the TRX II remote pressure sensor electricalinput (please refer to Option B2). Druck has applied thelatest technology and production techniques to developthese sensors which are digitally corrected for nonlinearity and temperature effects.SpecificationsOver 50 sensor ranges are available including gauge,absolute and differential versions and with accuracybetter than 0.05% FS, even the most up to datepressure instrumentation can be maintained andcalibrated.APPLICATION: Pressure CommentsMaximum line pressure 500 psiDifferential ranges uni-directional use onlyPressure connection: 1/4 NPT female.Note 1: Absolute up to 1000 psi.Note 2: All ranges shown in bold are in stock.Pressure switch

T R XI IStandard specificationMEASUREInputSPECIAL FEATURESRangemV0 . 100100 . 600V0 . 66 . 60mA0 . 52Ohms0 . 400400 . 2000Frequency0 . 655655 . 13101310 . 20,000Counts/minute0 . 6 x 105Counts/hour0 . 107 -1Totalizing0 . 108 025%0.05%0.01%0.005%0.02%0.006%0.1 Hz1 Hz2 c/min.2 c/hour2 counts emarksR - input 20 M OhmR - input 1 M OhmR - input 2.5 Ohm fusedat 0.9 mA excitationat 0.9 mA excitationR - input 300 k OhmR - input 300 k OhmR - input 300 k OhmR - input 300 k OhmR - input 300 k OhmR - input 300 k OhmAccuracy ( % of reading % of range)Temperature unitsÞF or ÞCTemperature scalesIPTS 68 or ITS 90 selectablePressure units15 unitsStep10 programmable, 10%, 20%, 25%. Manual step or adjustable timerRampFully programmable travel time (up/down and dwell)Scaling5 digits and sign on all electrical rangesTemperature transmitter calibrationBoth input and output readings in temperature unitsCalibration feature extended for all output /minpulses/hourRange-10 . 1000 . 120 . 240 . 4000 . 20000 . 108 -10 . 1000 . 20,0000 . 60000 . 0.02%infinite0.01 Hz1 Hz1 p/min1 p/hour .0010.010.110.01111RemarksR - output 0.2 OhmR - output 0.2 OhmR - max 900 Ohmat 1 mA excitationat 1 mA excitationR - input 300 k Ohm0 . 24 V/ 34 mA max.0 . 24 V/ 34 mA max.0 . 24 V/ 34 mA max.0 . 24 V/ 34 mA max.Accuracy ( % of reading % of -328/500 F F F F F F F F FAccuracyMeasure0.4 F0.7 F1.1 F0.6 F0.9 F0.6 F0.4 F0.4 F3.6 FResolutionSource0.4 F0.7 F1.1 F0.6 F0.9 F0.6 F0.4 F0.4 F3.6 F0.2 F0.2 F0.2 F0.06 F0.11 F0.06 F0.2 F0.2 F0.6 F➀ IEC 751,➁ JIS 1604-1989,➂ DIN 43760,④ MINCO 7, ⑤ MINCO 16-9Best case, Mid Range 7232/420832/4523 F F F F F F F F F F F FSignal converterConverts any input into any output, fully isolatedKeystrokingStorage for 9 user defined test configurationsSwitch testDisplay freezes on open and closed with Switch resistance measurementData log1 Mbyte up to 8 Mbyte of data storageComputer interfaceRS 232 and PCMCIA card (RS 232 cable and PCMCIA card are supplied withOption A or PCMCIA release card kit referenced on price list.)TEMPERATURERTDTemperature transmitter simulationmA output reads in temperature unitsAccuracyMeasure0.9 F0.6 F1.3 F0.6 F0.6 F1.8 F1.8 F2.5 F0.7 F1.1 F1.8 F1.8 F➀ IEC 584, ➁ DIN 43710Best case, Mid Range accuraciesNote: Thermocouple accuracies do not include cold junction compensation errorsLanguageEnglish, French, German, Italian, Portuguese and SpanishPower managementAuto backlight OFF, battery low indicator and status from menu.DISPLAYPanel2.6 x 1.6 inch Graphic LCD with backlightReadoutTypically 5 readings/ secondResolutionSource0.6 F0.4 F0.6 F0.4 F0.4 F1.3 F1.3 F1.3 F0.4 F0.6 F0.9 F0.9 FPCMCIA stationPCMCIA card type 1 or 20.20.20.20.20.20.20.20.20.20.20.20.2 F F F F F F F F F F F FENVIRONMENTALCalibration reference72 F 2ÞF, R.H. 45% 15%AccuraciesAccuracies true for 60 F to 80 F. Outside these limits add 0.0003%/ÞF typicallyTemperatureOperation: 15 F to 120 FHumidity:0 - 90% non condensingSealingGenerally to NEMA 12 (IP53)ConformityEN50081-1, EN50082-1, CE MarkedPhysical2.65 lb, 8.25 x 4.75 x 2.0 inchPower supply4 x 1.5 V alkaline “C” cells or 4 x 1.2 V Ni-Cad “C” cells

T R XI IOptions and related productsOPTIONS(A1) Linkpak-W calibration software (P/N LINKW)Linkpak-W calibration software has been developed to help meetthe growing demand on industry to comply with quality systemsand calibration documentation. Testprocedures are created in a Windows basedapplication and devices due for calibrationare reported and grouped into work ordersfor transfer to one of three calibrators, theDPI 605, TRX-II and the MCX. Calibrationresults, including files from the DPI 610, are uploaded to the PC viathe RS 232 interface or PCMCIA card, for analysis and to printcalibration certificates.RELATED PRODUCTSIntecal calibration management softwareIntecal Windows based software builds on the basic concept ofLinkpak W supporting laboratory and field calibrations with extensivemanagement and analysis features. Intecal interfaces with a range ofinstruments and offers a complete solution to calibration management.Portable field calibratorsDruck manufactures a wide range of portable pressure, temperature andelectrical field calibrators. A selection of these are shown below.(A2) Intecal-W calibration database software (P/N INTEW)Intecal-W Windows based software builds on the basic concept ofLinkpak-W supporting both portable fieldcalibrators and on-line workshop calibrators.Manual data entry is also a key feature forrecording data. Intecal-W is an easy to learnand easy to use calibration managementsoftware for process plants, workshops,contractors, manufacturers and service companies. It offers highproductivity of calibration scheduling, calibration work anddocumentation. Device information, calibration procedures andcalibration results are stored in an instrument database and multipledatabases can be created for organizing client accounts, processesor areas. Extensive management features are provided including adatabase search engine, time based calibration due queries andstandard reports.(B1) Remote pressure sensors (refer to pressure range table)Sensors from 1 to 10,000 psi are available for use with theTRX II. The calibrator has a single remote channel which can beconfigured for use with up to 8 sensors (one at a time). At least onemating cable is required per TRX II when ordering remote pressuresensors - see Option (B2)(B2) Mating cable for remote sensors P/N TAS-5-A074A 4.5 ft. mating cable for connecting remote sensors to the TRX II.At least one cable per TRX II should be ordered when orderingOption (B1).(C) Charger/power supply P/N 13603 state 110 or 220vThis adapter has been designed with two functions.It can either power the TRX II from line voltage or it can rechargeNi-cad batteries. The charger and adapter circuits are separate,allowing the user to recharge and operate the unit simultaneously.Laboratory and workshop instrumentsDruck also manufactures a comprehensive range of pressure indicatorsand controllers. Included in this range are the Pressurements industrialdeadweight testers and the Ruska high precision controllers and primarystandard piston gauges.Pressure transducers and transmittersDruck instruments complement an extensive range of pressuretransducers and transmitters, utilized in a variety of aerospace,automotive, depth level and process applications.Please refer to manufacturer for further information on related products.ORDERING INFORMATIONPlease state the following (where applicable):ACCESSORIESThe TRX II is supplied with carrying case, test leads, user guide, handbookand calibration certificate as standard.CALIBRATION STANDARDSCalibrators manufactured by Druck are calibrated against precisionequipment traceable to the National Institute of Standards and Technology(NIST). Druck is an ISO 9001 registered company.1. TRX II type number.2. Options, including part numbers. For remote pressure sensors pleasealso state the pressure range required.Note: Options should be ordered as separate items.Continuing development sometimes necessitates specificationchanges without notice.

The TRX II provides simple and flexible data transfer to fit in with most working practices. Information can be reviewed on screen or transferred to and from the TRX II using the RS 232 interface. Alternatively, without docking the instrument to