CABLES FOR ALARM AND SAFETY SYSTEMS - Nexans

Transcription

CAB L E S F O R A LA RMAND S A F E T Y SY S TEM S

2

IT S ALL ABOUTRELIABILITY.It is always important to choose high quality cables,especially when it comes to alarms and safety systems.Even small and seemingly insignificant details can makea big difference in terms of ease of handling,functionality and service life.We have the cables you are looking forWe offer the widest range of cables on the market for everykind of installation. The cables we supply carry signals andpower supplies. For extra peace of mind concerning fireprotection, our cables are available in versions meetingspecified fire safety requirements in installations.Halogen free for greater safetyWe have decided only to include halogen free cables in thisbrochure. There is a clear trend in that direction, and there isno longer any reason for not choosing halogen free cables.Halogen free cables offer many advantages – in particular,they make it easier to escape the building in the event of fire,generating substantial savings in the long run.100 years of experience thrown inAt Nexans we research, develop and manufacture cables forthe whole world. For different environments and climates. Andwe’ve been doing it for more than a hundred years. So whenyou choose our cables, they come with a whole lot more – ourdedication and all the experience and expertise we’ve built upover the decades.3

PRODUCT SEGMENTSVIDEO SURVEILLANCE(CCTV)FIRE ALARMSLocally installed CCTV (closed circuitlarge volumes so cables must beTV) systems are increasingly beingused as a crime prevention tool.Detector networks often occupyeasy to install. Nexans cables areeasy to strip and are optimisedto simplify installation in pipes.Choose from simple, non twistedpair cables for small conventionalsystems and twisted pair cables forlarger addressable systems. Thecables used in fire alarm detectornetworks should normally have ared sheath. If the cables arerequired to keep working duringa fire, you should use NexansAlsecure (see page 12”Performance during a fire”).4

PERFORMANCEDURING A FIREACCESS PROTECTIONThere is a separate fire class forsystem of control units and sensors.cables that are required to maintainsircuit integrity during a fire. Thesecables all have unique insulationmaterial that is not damaged likenormal cables. This category caninclude power supply cables as wellas signal cables. They should alsobe flame retardant low fire hazardBurglar alarms usually have aIndoor and outdoor entry systemscontain card readers, central unitsand computers. The cables used forintruder protection and entry controlare signal cables withvarying flexibility, shielding andcores. Alternatively, combinationcables can be used with separatecables – in other words they mustcores carrying the power supply.not give off any toxic or corrosiveNexans’ wide range makes it easygases, and only small amounts ofto choose the right cables for thesmoke, if there is a fire.various components.The Nexans cables for theseapplications are called Alsecure .The unique insulation (INFIT )makes the cables easy to installwhile ensuring they still work duringa fire.5

VIDEO SURVEILLANCE (CCTV)CCTV (Closed Circuit TeleVision) is a locally installed videosurveillance system. A CCTV system consists of cameras,monitors, transmission elements (cables), control systems and6storage systems. Our range of halogen free cables for CCTVRG 59 LSZHincludes 75 ohm coaxial cable.Coaxial cable for video surveillance. The impedance of theThe S/FTP Category 6A cable together with theIP67 outlet box offers a safe and robust solution forsolutions for IP network cameras outdoor and in harshenvironments.cable: 75 ohm.CableSTK no.Outer diam.LengthRG 59 LSZH02357046,1 mmBobbin/100RG 59 LSZH02357086,1 mmBobbin/500

S/FTP Category 6A LSZH PECategory 6A, 500 MHz Screened data cable. The 4 pairs areindividually foiled and covered with a common braid. Due tothe outer sheath of PE the cable is appropriate for outdoorinstallation as well as in exposed areas. It can be installedindoors when the PE sheet is removed. The cable fulfills cat 6ALANmark Industry outlet IP67performance according to EN 50288, IEC 61156The LANmark Industry outlet enables the installation of dataoutlets in exposed areas as well as outdoor solutions. The IP67level of protection is maintained both when the outlet is unusedand TIA 568-BCableSTK no.Outer diam.LengthCategory 6A 4x2x0,502333478,6 mmB/500and when the appropriate IP67 patchcords are connected.Includes 2 screened category 6 or category 6A connectors.CableSTK no.IP67 outer with RJ45 cat.6 shielded Snap-in connector, black.72800487

8

YOU OFTEN WON’T KNOWWHETHER YOU CHOSE THERIGHT CABLE UNTIL AFTERA FIRE.People always talk about fire protection but it is important to know what this actuallymeans in practical terms, and to be certain which flame spread rating you need to use.For cables, you also need to distinguish between flame spread, fire hazard properties andfire resistance.Cables that prevent flame spreadCables running through building levels and walls are a great way for fires to spread. Sothe most important requirement when establishing fire protection is to use cables withproperties that prevent the spread of fire. This is why there are general flame spreadclasses, and these must always be defined. Our cables have clearly marked flame spreadclasses that are informative and easy to understand.Halogen free – saving lives and moneySmoke and gases from burning cables often cause the biggest problems for people andequipment. These problems can be reduced if halogen free cables are used. The smokefrom halogen free cables during a fire is much thinner and does not corrode metals.This makes it easier to clear smoke from rooms, potentially saving lives. That is why ourcables for alarms and safety systems are halogen free.Still working during a fireThe most critical cables must also be fire resistant. This means they must be guaranteedto work even during a fire. This is made possible by special insulation material, which ismerely altered rather than destroyed by fire. The cable keeps its shape, the conductorsare kept separate and the cable continues to work. These cables are needed for the firealarm system itself, but also for the safety lighting guiding people out of the building, forthe smoke extraction fans and for the lifts. Our range includes fire resistant cables forpower supply and for communication.9

FIRE ALARMSNexans has a full range of cables for fire alarm systemsThe right cable for the right useCables for fire alarms are available with either red or greyKLM Easy LSZH 2x1,0sheaths depending on the regulations, aesthetic requirements,Halogen free, pair-twisted signal cable. The cable constructionetc. In larger addressable systems, twisted pair cable shouldis as specified in SS 424 16 54 (EQQYB).be used, KLM-LSZH 2x1.0 mm. If shielded cable is required,CableNexans supplies the KLMA LSZH. If the cables are required tokeep working during a fire, fire resistant Alsecure cables areSTK no.Outer diam.LengthKLM Easy LSZH 2x1,002333585,7 mmBobbin/500KLM Easy LSZH 2x1,002357135,7 mmBobbin/100 used.InstallationThe cables for fire alarms are intended for permanent indoorinstallation.KLM LSZHHalogen free signal cable. The cable construction is, whereapplicable, as specified in SFS 2751.CableSTK no.Outer diam.LengthKLM LSZH 2x0,802333624,0 mmCoil/150KLM LSZH 2x0,802333604,0 mmBobbin/600KLM LSZH 4x0,802333685,0 mmCoil/150KLM LSZH 4x0,802333645,0 mmBobbin/600KLMA LSZHHalogen free, pair-twisted signal cable. The cable constructionis as specified in SFS 2751.10CableSTK no.Outer diam.LengthKLMA LSZH 2x0,802333705,0 mmCoil/150KLMA LSZH 2x0,802333695,0 mmBobbin/600KLMA LSZH 4x0,802333785,5 mmCoil/150KLMA LSZH 4x0,802333745,5 mmBobbin/600

11

PERFORMANCE DURING A FIREFire resistant cables are recommended for use in installationsthat must maintain circuit integrity during a fire. Using thesecables in important alarm, control, signal and power supplysystems means you can guarantee they will not be taken down,even if the fire reaches the cables themselves.InstallationExamples of systems that must maintain circuit integrity during afire include signal and safety systems guiding people out of thebuilding. Other examples are smoke extraction fans and lifts.Fire alarm cables, too, if they pass through areas that are notmonitored by detectors, are required to maintain circuit integrityNo gases, little smokeAs well as continuing to work during and after a fire, Nexans fireduring a fire.resistant cables are halogen free so they do not release any toxicor corrosive gases, and only small amounts of smoke, if there isa fire. Studies show that this can save lives and money.ALSECURE PLUS 0,6/1kV, FRHFALSECURE PREMIUMFire resistant power cable with round or sector shaped,Fire resistant, twisted pair, fire alarm cables for permanentstranded, soldered copper conductor and concentric shielding.installation indoors or in pipes. Fire performance according toFor permanent installation in all areas. Fire performanceIEC60331, IEC 60332-3.according to IEC 60331, IEC 60332-3.12CableSTK no.Outer diam.LengthCableSTK no.Outer diam.LengthAlsecure Premium 2 x 1,0 mm02357476,2 mmBobbin/500Alsecure Plus 1 kV 2 x 1,5/1,5063850211,9 mmDrum/500Alsecure Premium 10 x 2 x 1,0 mm023574817,0 mmDrum/500Alsecure Plus 1 kV 3 x 1,5/1,5063850312,5 mmDrum/500Alsecure Plus 1 kV 4 x 1,5/1,5063850415,2 mmDrum/500Alsecure Plus 1 kV 2 x 2,5/2,5063850614,7 mmDrum/500Alsecure Plus 1 kV 3 x 2,5/2,5063850715,2 mmDrum/500Alsecure Plus 1 kV 4 x 2,5/2,5063850816,4 mmDrum/500Alsecure Plus 1 kV 4 x 6/6063851018,1 mmDrum/500Alsecure Plus 1 kV 4 x 10/10063851122,0 mmDrum/500Alsecure Plus 1 kV 4 x 16/16063851224,2 mmDrum/500Alsecure Plus 1 kV 4 x 25/16063851326,0 mmDrum/500Alsecure Plus 1 kV 4 x 35/16063851430,0 mmDrum/500Alsecure Plus 1 kV 4 x 50/25063851635,0 mmDrum/500Alsecure Plus 1 kV 4 x 70/35063851736,0 mmDrum/500Alsecure Plus 1 kV 4 x 95/50063851841,0 mmDrum/500Alsecure Plus 1 kV 4 x 120/70063851942,2 mmDrum/500Alsecure Plus 1 kV 4 x 150/70063852049,0 mmDrum/500Alsecure Plus 1 kV 4 x 185/95063852152,0 mmDrum/500Alsecure Plus 1 kV 4 x 240/120063852260,0 mmDrum/500

ALSECURE PREMIUM 300/500VFire resistant, halogen free control cables with round, solidcopper conductors. This cable is designed for permanentinstallation on cable ladders, directly on walls or in pipes orducting. Applications include emergency lighting, fire alarmsystems and control systems. Fire performance according toIEC60331, IEC 60332-3.CableSTK no.Outer diam.LengthDrum/500Alsecure Premium 3G1,506034708,0 mmAlsecure Premium 3G2,5060347110,0 mmDrum/500Alsecure Premium 4G1,506034729,5 mmDrum/500Alsecure Premium 5G1,5060347310,0 mmDrum/500Alsecure Premium 5G2,5060347412,0 mmDrum/50013

ACCESS PROTECTIONOur cables for intruder alarms and entry systems come in arange of types. We have shielded as well as unshielded twistedpair cables – up to hundred pairs. We also offer flexible singlewire cables with 4 to 12 cores. Combination cables are alsoEQQXB EasyTM(halogen free EKKX)available for entry systems – cables with twisted pair signalPair-twisted communication cable with halogen free, flameelements and power supply elements (max 100 V).retardant insulation and sheath. An important feature of the cableFire performance according to CPR cluss Dca-s2,d2,a2.is that both insulation and sheath are easy to peel. You can evenpeel the insulation with your nail.FQQXBFlexible signal and alarm cables for intruder alarms and accessNexans no.Outer diam.Outer diam.Length171120413,5 mmBobbin/100EQQXB Easy TM 1 x 4 x 0,5 mm171120713,5 mmBobbin/500EQQXB Easy TM 2 x 2 x 0,5 mm171122414,3 mmBobbin/100EQQXB Easy TM 2 x 2 x 0,5 mm171122714,3 mmBobbin/5004 x 2 x 0,5 mm171124415,5 mmBobbin/100171124715,5 mmBobbin/500LengthEQQXB Easy TM 6 x 2 x 0,5 mm171126416,0 mmBobbin/1006 x 2 x 0,5 mmEQQXB EasyTM2175271413,7 mmBobbin/100EQQXB Easy171126716,0 mmBobbin/500FQQXB 4 x 0,22 mm2175271713,7 mmBobbin/500EQQXB Easy TM 10 x 2 x 0,5 mm171129417,3 mmBobbin/100FQQXB 6 x 0,22 mm2175272414,2 mmBobbin/100EQQXB Easy TM 10 x 2 x 0,5 mm171129717,3 mmBobbin/500FQQXB 4 x 0,22 mmTM2175272714,2 mmBobbin/500EQQXB Easy20 x 2 x 0,5 mm171130989,8 mmBobbin/500FQQXB 8 x 0,22 mm2175273414,7 mmBobbin/100EQQXB Easy TM 30 x 2 x 0,5 mm1711319811,7 mmBobbin/500175273714,7 mmBobbin/500EQQXB Easy TM 50 x 2 x 0,5 mm1711339814,4 mmBobbin/500EQQXB Easy1711359819,5 mmBobbin/500FQQXB 6 x 0,22 mmFQQXB 8 x 0,22 mm22175274415,4 mmBobbin/100FQQXB 12 x 0,22 mm2175274715,4 mmBobbin/500FQQXB 12 x 0,22 mmMHS LSZHPair-twisted, shielded communication cable with halogen free,flame retardant sheath. The cable construction is, whereapplicable, as specified in SFS 5739.14Nexans no.EQQXB Easy TM 1 x 4 x 0,5 mmEQQXB Easy TM 4 x 2 x 0,5 mmcontrol systems.CableCableCableSTK no.Outer diam.LengthMHS LSZH 1x4x0,502333805,0Coil/100MHS LSZH 1x4x0,502333795,0Drum/1000MHS LSZH 3x2x0,502333826,0Coil/200MHS LSZH 3x2x0,502333816,0Drum/1000MHS LSZH 5x2x0,502333846,5Coil/150MHS LSZH 5x2x0,502333836,5Drum/1000MHS LSZH 10x2x0,502333868,5Coil/100MHS LSZH 10x2x0,502333858,5Drum/1000TMTM100 x 2 x 0,5 mm

FLQQBRFLAQQBRCombined power supply and signal cables for intruder alarmsCombined power supply and signal cables for intruder alarmsand entry systems. The twisted pair signal element is unshielded.and entry systems. The twisted pair signal element is unshielded.CableNexans no.Outer diam.LengthCableNexans no.Outer diam.LengthFLQQBR 2 x 1,5 2 x 2 x 0,5 mm2170306988,5 mmDrum/500FLAQQBR 2 x 1,0 1 x 2 x 0,22 mm2170371416,5 mmBobbin/100FLQQBR 2 x 1,0 1 x 2 x 0,22 mm2170301416,5 mmBobbin/100FLAQQBR 2 x 1,0 1 x 2 x 0,22 mm2170371716,5 mmBobbin/5002FLQQBR 2 x 1,0 1 x 2 x 0,22 mm170301716,5 mmBobbin/500FLAQQBR 2 x 1,0 2 x 2 x 0,22 mm2170372988,0 mmDrum/500FLQQBR 2 x 1,0 2 x 2 x 0,22 mm2170302717,5 mmBobbin/500FLAQQBR 4 x 1,0 2 x 2 x 0,22 mm2170376988,7 mmDrum/500FLAQQLYCombined power s

Fire resistant, halogen free control cables with round, solid copper conductors. This cable is designed for permanent installation on cable ladders, directly on walls or in pipes or ducting. Applications include emergency lighting, fire alarm systems and control systems. Fire