SafeSite LED Dual Floodlight - UL

Transcription

SafeSite LED Dual Floodlight - ULfor Indoor and Outdoor Hazardous Applications

Features & BenefitsApplication 10 year warranty L70 rated for 100,000 hours @25oC ambient Instant on/off operation Universal input (100-277 VAC,50/60Hz and 347/480 VAC, 60Hz) Superior color rendition indexcompared to HPS, LPS, MH Mercury free Resistant to shock and vibration Temperature compensationtechnology for longer life Safety tabs provided for secondaryretentionThe SafeSite LED Floodlightrepresents the future of energyefficient facility illumination forhazardous applications worldwide.The lighting fixture consumes at least50% less energy than traditionalHID light sources, while reducingmaintenance and carbon emissions.This light incorporates both cuttingedge LED technology along withproprietary optics to achieve floodlighting comparable with othertraditional light sources.www.dialight.com2

SafeSiteIndustrial Applications Dual FloodlightSafeSite LED Dual Floodlight100-277 VAC, 120-250 VDC ModelsMechanical Information:Fixture weight:56 lb (25.4 kg)Shipping weight:60 lb (27.2 kg)EPA (Sq.ft):2.69Mounting:304 Stainless Steel trunnion mountingbracket includedEntries:(2) 3/4” NPT cable entriesElectrical Specifications:Operating voltage:100-277 VAC, 50/60Hz120-250 VDCPower consumption:See tableOperating temp:-40 F to 149 F (-40 C to 65 C)Noise requirement /EMC:FCC Title 47, Subpart B, Section 15,Class A device. RF Immunity; 10V/m,80MHz-1GHzSurge protection:6kV/2 ohm combination wave, as perIEEE C62.41, line-line and line-groundTHD: 20%Power factor: 0.9Certifications & Ratings UL 1598/AUL 844Class I, Div. 2 Groups A, B, C, DCSA C22.2 No. 250CSA C22.2 No. 137 NEMA 4X IP66 IK07Variable Dimming:Variable Dimming Control: 0-10 VDCDimming Range:Construction:10 VDC 100% light output0 VDC 5% light outputHousing:Copper-free aluminumFinish:Superior dual coat finish- Sealed polyester topcoat- Chemical-resistant epoxy primerLens:Tempered glassPhotometric Information:CRI:80CCT:5000K (cool white)4000K (neutral white)2700K (warm white)Beam patterns:Medium distributionNEMA 6 distributionNEMA 7x6 distributionIES files:Available at www.dialight.comDimensions in inches [mm]All values typical unless otherwise stated (tolerance /- 10%)Temperature Ratings3Ambient Temperature Range T4Ambient Temperature Range T5-40 F to 149 F (-40 C to 65 C)-40 F to 122 F (-40 C to 50 C)www.dialight.com

SafeSiteIndustrial Applications Dual FloodlightSafeSite LED Dual Floodlight347-480 VAC ModelsMechanical Information:Fixture weight:73 lb (33.1 kg)Shipping weight:79 lb (35.8 kg)EPA (Sq.ft):2.69Mounting:304 Stainless Steel trunnion mountingbracket includedEntries:(2) 3/4” NPT cable entriesElectrical Specifications:Certifications & Ratings UL 1598/AUL 844Class I, Div. 2 Groups A, B, C, DCSA C22.2 No. 250CSA C22.2 No. 137 NEMA 4X IP66 IK07Operating voltage:347-480 VAC, 60HzPower consumption:See tableOperating temp:-40 F to 149 F (-40 C to 65 C)Noise requirement /EMC:FCC Title 47, Subpart B, Section 15,Class A device. RF Immunity; 10V/m,80MHz-1GHzSurge protection:6kV/2 ohm combination wave, as perIEEE C62.41, line-line and line-groundTHD: 20%Power factor: 0.9Variable Dimming:Variable Dimming Control: 0-10 VDCDimming Range:10 VDC 100% light output0 VDC 5% light outputConstruction:Housing:Copper-free aluminumFinish:Superior dual coat finish- Sealed polyester topcoat- Chemical-resistant epoxy primerLens1:Tempered glassPhotometric Information:CRI:80CCT:5000K (cool white)4000K (neutral white)2700K (warm white)Beam patterns:Medium distributionNEMA 6 distributionNEMA 7x6 distributionIES files:Available at www.dialight.comDimensions in inches [mm]All values typical unless otherwise stated (tolerance /- 10%)Temperature RatingsAmbient Temperature Range T3C-40 F to 149 F (-40 C to 65 C)www.dialight.com4

SafeSiteIndustrial Applications Dual FloodlightSafeSite LED Dual FloodlightDimensional Drawings & Beam DistributionDual Floodlight Mounting OptionsFactory Installed Mounting Bracket DimensionsDimensions in inches [mm]MediumDimensions in inches [mm]NEMA 6NEMA 7x65www.dialight.com

SafeSiteIndustrial Applications Dual FloodlightSafeSite LED Dual FloodlightOrdering Information & Mounting AccessoriesLegacyPart NumberPart NumberFixtureLumensVoltagelm/WWattageCCTLensBeam Pattern100-277 VAC ModelsFDD76C2MDSNNGNFLDB66NC2NG56,000385145100-277 VAC5000K (cool white)Clear Tempered GlassNEMA 6FDD7MC2MDSNNGNFLDBM0NC2NG54,000385140100-277 VAC5000K (cool white)Clear Tempered 0-277 VAC5000K (cool white)Clear Tempered GlassNEMA 7X6FDD76C2HDSNNGNFLD966NC2NG39,000270144100-277 VAC5000K (cool white)Clear Tempered GlassNEMA 6FDD77C2HDSNNGNFLD976NC2NG37,500270141100-277 VAC5000K (cool white)Clear Tempered GlassNEMA 7x6All values typical unless otherwise stated (tolerance /- 10%).For neutral white models, replace the 6th character (standard) / 8th character (legacy) with an N. Ex. FDD76C2MNSNNGN / FLDB66NC2NG becomes FDD76N2MNSNNGN/ FLDB66NN2NG. For warm white models, replace the 6th character (standard) / 8th character (legacy) with an N. Ex. FDD76C2MNSNNGN / FLDB66NC2NG becomesFDD76W2MNSNNGN / FLDB66NW2NG.Part NumberLegacyPart NumberFixtureLumenslm/WWattage347 VAC 480 VAC347 VAC480 VACVoltageCCTLensBeamPattern347-480 VAC 47-480 VAC5000K (cool white)Clear Tempered GlassNEMA 0 VAC5000K (cool white)Clear Tempered 8132347-480 VAC5000K (cool white)Clear Tempered GlassNEMA 480 VAC5000K (cool white)Clear Tempered GlassNEMA 0 VAC5000K (cool white)Clear Tempered GlassNEMA 7x6All values typical unless otherwise stated (tolerance /- 10%).For neutral white models, replace the 6th character (standard) / 8th character (legacy) with an N. Ex. FDD76CAMNSNNGN / FLDB66NC5NG becomes FDD76NAMNSNNGN/ FLDB66NN5NG. For warm white models, replace the 6th character (standard) / 8th character (legacy) with an N. Ex. FDD76CAMNSNNGN / FLDB66NC5NG becomesFDD76WAMNSNNGN / FLDB66NW5NG.HZXCBL2 Safety cable kit Kit includes: (2) safety cablesFLX-3RPA-20DBFLX-4RPA-20DB Reducer for 3” or 4” OD round pole top to2-3/8” light mount Kit includes: Reducer pole set screwswww.dialight.comFLX-1TPT-20DB1 Tenon pole topper, 2-3/8” mount Kit includes: Tenon topper, pole setscrews, and mounting hardware1Bracket and adapters require tenon adapter(FLX-1TPT-20DB) to mount floodlight. Tenonadapter is sold separately.FLX-4SPA-20DBFLX-5SPA-20DBFLX-6SPA-20DB Internal tenon adapter for 4”, 5” or 6”square pole top to 2-3/8” light mount Kit includes: Adapter6

North American HQ1501 Route 34 SouthFarmingdale, NJ 07727Tel: 732-919-3119Fax: 732-751-5778info@dialight.comAustralia38 O'Malley StreetOsborne Park, WA 6017Tel: 61 (0) 8 9244 7600Fax: 61 (0) 8 9244 7601info@dialight.com.auEMEA Technical CentreEjby Industrivej 91 B200 GlostrupTel: 45 8877 4545 (Denmark)Tel: 44 1638 666541 (UK)Tel: 49 89 12089 5713 (Germany)Tel: 33 3 23 22 62 58 (France)sales-europe@dialight.comSoutheast Asia33 Ubi Avenue 3#07-72 Vertex (Tower A)Singapore 408868Tel: 65 6578 7157Fax: 65 6578 7150enquiry@dialight.com.sgHouston16830 Barker Springs RdSte 407Houston, TX 77084Tel: 732-919-3119Faz: 281-492-1531info@dialight.comBrazilAlameda Mercurio,225 – American Park Empresarial NRIndaiatuba – SP – 13347– 662Tel: 55 (19) 3113-4300Fax: 55 (19) 3113-4300brasil@dialight.comMiddle EastLevel 42Emirates Towers (Office Tower)Sheikh Zayed RoadDubai, United Arab EmiratesFax: 971 (0) 4319 7686Tel: 971 (0) 4319 7686ALL VALUES ARE DESIGN OR TYPICAL VALUES WHEN MEASURED UNDER LABORATORY CONDITIONS. THE LIGHTING EFFICIENCY STATEMENTSCONTAINED HEREIN ARE CALCULATED ON A LUMEN PER WATTS BASIS WHEN COMPARING FIXTURES WITH SIMILAR FEATURES. ALL INFORMATIONPROVIDED IS ACCURATE AS OF THE DATE OF PUBLICATION, IS SUBJECT TO CHANGE WITHOUT NOTICE AND DOES NOT FORM PART OF ANYCONTRACT WITH DIALIGHT. DIALIGHT DOES NOT WARRANT OR REPRESENT THAT ITS PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE AND HASNO RESPONSIBILITY FOR THE [INAPPROPRIATE/UNAUTHORISED/NON-APPROVED] USE OF ANY DIALIGHT PRODUCTS BY THE END USER.Dialight reserves the right to make changes at any time in order to supply the best product possible.The most current version of this document will always be available at: www.dialight.comDialight LED Vigilant Floodlight SpecSheet UL August2018

info@dialight.com.au Southeast Asia 33 Ubi Avenue 3 #07-72 Vertex (Tower A) Singapore 408868 Tel: 65 6578 7157 Fax: 65 6578 7150 enquiry@dialight.com.sg Brazil Alameda Mercurio, 225 – American Park Empresarial NR Indaiatuba – SP – 13347– 662 Tel: 55 (19) 3113-4300 Fax