M100 HVAC & ELECTRICAL PLANS REC CENTER

Transcription

OWNER:PROJECT NAME:1.ATSTITLE SHEETA100A101A102FLOOR PLAN & ELEVATIONSDETAILS & SCHEDULESDETAILS & SCHEDULESP100M100PLUMBING PLANSHVAC & ELECTRICAL PLANSARCHITECT:PROJECT ADDRESS: 295 MIDDLE ROADLAPOINTE, WI 54850C&S DESIGN & ENGINEERING, INC.803 LAKE SHORE DRIVE WESTASHLAND, WI 54806P: 715-682-0330STRUCTURAL ENGINEER: C&S DESIGN & ENGINEERING, INC.803 LAKE SHORE DRIVE WESTASHLAND, WI 54806P: 715-682-0330CONSULTANT:N/APLUMBING DESIGNER:N/AHVAC ENGINEER:ELECTRICAL ENGINEER:SYMBOLSKEY NOTEPROJECT NUMBER: 19-3384TOWN OF LAPOINTEPARCEL NUMBERS:014-00438-0200LEGALDESCRIPTION:LOTS 4-9 INCL & PART OF LOTS 10-13INCL BLK 37, VILLAGE OF LAPOINTE,ASHLAND COUNTY, WISCONSIN4.5.GOVERNING CODES: 2015 INTL BUILDING CODE2015 INTL ENERGY CONSERVATION CODE2015 INTL EXISTING BUILDING CODE2015 INTL FUEL GAS CODE2015 INTL MECHANICAL CODEANSI A117.1-2009 ACCESSIBILITY CODECONST TYPE:VBBLD GROSS AREA:B 1,024 SF7.OVER 50,000 CF YESNOBLD VOLUME:UNDER 25,000 CF YESNO# OF STORIES:1 STORYALLOWABLE AREA:9,000 SF / STORYALLOWED STORIES:2 STORYSPRINKLERED:YESNOFIRE ALARM SYS:YESNOOCCUPANT LOAD:ASSEMBLY (unconcentrated) 15 NET SF / OCC405 / 15 27 OCCUPANTSRESTROOMS/MECH 200 GROSS SF / OCC556 / 200 3 OCCUPANTSEXITS REQ'D:(B) 1 EXITS FOR OCC LOAD 4912.COMMON PATHEXIT TRAVEL MAX:(PER IBC TABLE 1016.1) 75 FEET13.8.9.10.WINDOW TAG100SLOPE OF SLAB15.AD#BA#.#11.14.DOOR TAGSLOPE:6.BLD VOLUME:ROOF SLOPE & DIRECTIONH3.OWNER:PROJECT NET AREA: B 1,024 SFN/A3:122.OCCUPANCY GROUP: B (ASSEMBLY AREA UNDER 50 OCCUPANTS)N/A1LAPOINTE REC CENTER16.INTERIOR ELEVATION TAGC 1"T.O. SLAB106'-0"ADROLEDMIDA17.STEP/ELEVATION CHANGE18.ELEVATION MARKERWALL TYPE (SEE PLAN ORLEGEND FOR ADD. INFO)19.12ROOF SLOPE4PARKING AREAAPPROX. LOCATION OFEXISTING 4" WASTE LINETO CITY SANITARYON-SITE MBUILDING1.0GRID LINE1A200BUILDING ELEVATION20.21.22.1A300BUILDING SECTION1A401WALL SECTION23.24.25.26. Copyright 2019 C&S Design & Engineering, Inc, all rights reserved. Any use without permission is expressly prohibited. Plotted 6/8/2021 10:40 AM1A400PARKING AREATENNIS COURTSDETAIL/ENLARGED PLANCALLOUT27.NORTH1A50028.DETAIL CALLOUT29.30.SITE PLAN31.SCALE: 1" 30'32.PROJECT LOCATIONLAPOINTE, WITHE CONTRACTORS ARE TO KEEP A SET OF STATE APPROVEDPLANS AT THE JOB SITE AT ALL TIMES.A PRE-CONSTRUCTION CONFERENCE WILL BE HELD WITH THECONTRACTORS BEFORE ANY WORK COMMENCES.ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH THESTATE BUILDING, PLUMBING, ELECTRICAL, AND HVAC CODECURRENTLY IN EFFECT.ALL STATE AND LOCAL BUILDING PERMITS WILL BE OBTAINEDBY THE OWNER AND MUST BE POSTED AT THE JOB SITE BY THECONTRACTOR, U.N.O.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CHECKINGALL CONTRACT DOCUMENTS FOR THEIR ACCURACY ANDCONFIRMING THAT WORK IS BUILDABLE AS SHOWN BEFOREPROCEEDING WITH CONSTRUCTION. IF THERE ARE ANYQUESTIONS REGARDING THESE, OR OTHER COORDINATIONQUESTIONS, THE CONTRACTOR IS RESPONSIBLE FOROBTAINING CLARIFICATION FROM THE ARCHITECT BEFOREPROCEEDING WITH THE WORK IN QUESTION OR RELATEDWORK.THE OWNER SHALL INDEMNIFY AND HOLD HARMLESS THEDESIGN PROFESSIONAL FROM ANY CLAIM OR SUITWHATSOEVER ARISING FROM, OR ALLEGED TO HAVE ARISENFROM, THE CONTRACTOR'S PERFORMANCE OR THE FAILUREOF THE CONTRACTOR'S WORK TO CONFORM TO THE DESIGNINTENT OF THE CONTRACT DOCUMENTS.THE WORK UNDER THE CONTRACT SHALL INCLUDE ALL LABOR,MATERIALS, TOOLS, FEES, INSURANCE, TAXES, ETC. FORGENERAL CONSTRUCTION, INCLUDING MECHANICAL,PLUMBING AND ELECTRICAL CONSTRUCTION, AS APPLICABLE,FOR THE COMPLETE CONSTRUCTION OF THIS PROJECT.ALL PRODUCTS AND MANUFACTURERS OFMATERIALS/FINISHES/ETC PER ARCHITECTURAL DRAWINGS ORSPECIFICATION. SUBSTITUTIONS OF EQUAL QUALITY ANDPERFORMANCE PERMITTED AS APPROVED BY DESIGNPROFESSIONAL IN CHARGE.ALL MATERIALS, SUPPLIES, AND EQUIPMENT SHALL BEINSTALLED AS PER MANUF. SPECIFICATIONS AND AS PERLOCAL CODES AND REQUIREMENTS, LOCATED PER PLANTHE CONTRACTOR MUST VERIFY ALL EXISTING CONDITIONS ATTHE JOB SITE.THE DESIGN PROFESSIONAL WILL NOT HAVE CONTROL OVER,OR CHARGE OF, AND WILL NOT BE RESPONSIBLE FOR THECONSTRUCTION MEANS, METHODS, SEQUENCE ORPROCEDURES IN REGARDS TO THE MANNER IN WHICH THESTRUCTURE IS BUILT.ALL PROPERTY LINES ARE ASSUMED UNLESS A CERTIFIEDSURVEY MAP HAS BEEN PROVIDED FOR THE PROPERTY.ALL BUILDING SETBACKS ARE MEASURED FROM THE EAVE LINEOF THE BUILDING.THE CONTRACTOR IS TO HAVE ALL THE UTILITY LINES VERIFIEDBY THE APPROPRIATE UTILITY LOCATING SERVICE. THECONTRACTOR SHALL BE RESPONSIBLE TO HAVE A LOCATEDONE PRIOR TO BREAKING OF GROUND.THE CONTRACTOR SHALL BE AWARE OF ALL PRIVATE UTILITIESLOCATIONS SUCH AS WATER, SEWER, AND GAS.ALL DAMAGE TO EXISTING DRIVEWAYS, ROADWAYS, STREETS,CONCRETE SIDEWALKS, LAWNS, ETC. MUST BE RESTORED TOTHE CONDITION THEY WERE BEFORE CONSTRUCTIONCOMMENCED.PROVIDE A MINIMUM OF 2% DRAINAGE SLOPE AWAY FROM THEENTIRE PERIMETER OF THE BUILDING FOR THE FIRST 20 FEET,U.N.O.THE GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLEFOR THE DESIGN, ADEQUACY, AND SAFETY OF ERECTINGBRACING, SHORING AND TEMPORARY SUPPORTS, ETC. THEGENERAL CONTRACTOR IS RESPONSIBLE FOR THE STABILITYOF THE STRUCTURE PRIOR TO THE APPLICATION OF ALLSHEAR WALLS, ROOF SHEATHING, STRUCTURAL ELEMENTSAND FINISH MATERIALS.THE GENERAL CONTRACTOR SHALL PERFORM HIGH QUALITYPROFESSIONAL WORK; JOIN MATERIALS TO UNIFORM,ACCURATE FITS SO THAT THEY MEET WITH NEAT, STRAIGHTLINES, FREE OF SMEARS OR OVERLAPS; INSTALL EXPOSEDMATERIALS APPROPRIATELY LEVEL, PLUMB AND AT ACCURATERIGHT ANGLES OR FLUSH WITH ADJOINING MATERIALS. WORKOF EACH TRADE SHALL MEET ALL NATIONAL STANDARDSPUBLISHED BY THAT TRADE, EXCEPT IN THE CASE WHERE THECONTRACT DOCUMENTS ARE MORE STRINGENT.ALL EXISTING BUILDING DIMENSIONS MUST BE FIELD VERIFIED.WRITTEN DIMENSIONS TO PREVAIL OVER SCALING OFDRAWINGS. CONTRACTOR(S) TO VERIFY ALL DIMENSIONSPRIOR TO CONSTRUCTION AND IMMEDIATELY NOTIFYDESIGNER OF ANY DISCREPANCIES.ALL DIMENSIONS TO FACE OF STUD OR CONCRETE WALLS,U.N.OSEE SITE PLAN FOR NOTES AND DIMENSIONS NOT SHOWN.SEE ELEVATIONS, INTERIOR ELEVATIONS AND FINISHSCHEDULE FOR MATERIALS NOT CALLED OUT.IF APPLICABLE, THE FIRE RATING OF WALLS AND CEILINGSMUST BE MAINTAINED BEHIND ALL INSTALLED FIXTURES (BATHUNITS, VANITIES, CEILING FANS, ELECTRICAL BOXES, EXHAUSTFANS, ETC.THE CONTRACTOR SHALL TAKE ABSOLUTE CARE TO PROTECTNEWLY INSTALLED MATERIALS, MILLWORK, BUILT-INS ANDFINISHES.THE CONTRACTOR SHALL PROVIDE ALL OPERATING ANDMAINTENANCE DATA AND ALL MANUFACTURER'S, INSTALLER'SAND APPLICATOR'S GUARANTEES, BONDS, WARRANTIES ANDSERVICE INSTRUCTIONS.CONFIRM WINDOW OR DOOR NUMBER WITH MFR. AND SITECONDITIONS. ALL OPERABLE WINDOWS AND DOORS SHALLHAVE REMOVABLE SCREENS.CONTRACTOR TO VERIFY R.O. REQUIREMENTS FOR WINDOWS& EXTERIOR DOORS WITH WINDOW MANUFACTURER PRIOR TOORDERINGREFERENCE ELEVATIONS AND/OR BUILDING SECTIONS FORWINDOW OPERATIONS.REFER TO ENGINEERED TRUSS DRAWINGS, IF APPLICABLE,FOR PLACEMENT OF TRUSS COMPONENTS. CONTRACTOR ISTO FIELD VERIFY ALL TRUSS DIMENSIONS BEFOREPRODUCTION OF TRUSSES.ALL GAS PIPING INSTALLATIONS SHALL COMPLY WITH NFPA 542015, NATIONAL FUEL GAS CODE.803 Lake Shore Drive West, Ashland, WI 54806Telephone (715) 682-0330 www.csdesignengineering.comTOWN OF LAPOINTELAPOINTE, WI TUMINOUSBLOCKBLOCKINGBOARDBOTTOMBOTTOM OFBRICK COURSEBUILDINGBUILT-UP ROOFINGCARPETCAST-IN-PLACECAST IRONCATCH BASINCEILINGCEMENTCENTER LINECERAMIC TILECLEARANCECLOSETCOLUMNCONCRETECONCRETE MASONRY L JOINTCOURSESCUBIC OWNSPOUTDRAWING (S)DRINKING UALEQUIPMENTEXHAUSTEXISTINGEXPANSIONEXPANSION JOINTEXPOSEDEXTERIORFACE OFFACE OF CONCRETEFACE OF FINISHFACE OF MASONRYFEETFINISHFINISH FLOOR ELEVATIONFINISH GRADEFINISH SURFACEA.D.E.A.D.E.AS NOTEDJUNE 2021PROJECT NO.19-3384REVISIONS:STANDARD ABBREVIATIONSABOVE FINISH FLOORACOUSTICAL CEILING TILEADDITIONALADJUSTABLEALIGN WITH BELOWALTERNATEALUMINUMAMERICAN DISABILITIES ACTAPPROXIMATELYTITLE PAGEINDEX TO DRAWINGS295 MIDDLE ROAD, LAPOINTE, WI 54850295 MIDDLE ROADLAPOINTE, WI 54850GENERAL NOTESLAPOINTE REC CENTERLAPOINTEREC CENTERPROJECT DATAPROPOSED RENOVATIONS FOR:PROPOSED RENOVATIONS FOR:PROJECT TEAMCONTR.C.J.CRS.CFDET.DIA.DIM.DISPDRDN.DS.DWG. G.F.S.FIRE EXTINGUISHERFIRE EXTINGUISHER CABINETFIRE RATEDFIXTUREFLASHINGFLOORFLOORINGFLOOR NERAL CONTRACTORGLASSGYPSUMGYPSUM WALLBOARDGALV.GA.G.C.GL.GYP.GWB.HANDICAP ACCESSIBLEHARDWAREHEATERHEATING, VENTING, ANDAIR CONDITIONINGHEIGHTHIGH POINTHOLLOW COREHOLLOW HINCLUDINGINSIDE EDLAVATORYLEVELLIGHTINGLINELINOLEUMLONG LEG HORIZONTALLONG LEG VERTICALLOW POINTMANUFACTURERMASONRYMASONRY UMMISCELLANEOUSMOUNTEDNON-COMBUSTIBLENOT APPLICABLENOT IN CONTRACTNOT TO SCALENUMBEROCCUPANT / OCCUPANCYON CENTEROPENINGOPPOSITEOPPOSITE HANDOUTSIDE FLOW STIC LAMINATEPLATEPOLYVINYL CHLORIDEPOUNDS PER SQUARE INCHPRESERVATIVE .T.PROP.QUANTITYQUARRY TILEQTY.Q.T.RADIUSREINFORCINGREQUIREDRESILIENT FLOORINGRETURN AIRREVISIONRISERROOF DRAINROOMROUGH O.RUBR.SECTIONSHEETSIMILARSOLID CORESPECIFICATIONSSQUARESQUARE FOOT(AGE)STAINLESS EELSTORAGESTREETSTRUCTURALSUSPEND (ED)TELEPHONETHERMOPLASTIC POLYOLEFINTHICKNESSTOP OFTOP OF CONCRETETOP OF FOOTINGTOP OF RAILTOP OF STEELTOP OF WALLTREADTREATEDTRENCH DRAINTYPICALSTL.STOR.ST.STRUCT.SUSP. TRTT.D.TYP.UNDERWRITERSLABORATORIESUNLESS NOTED OTHERWISEU.N.O.VENEER PLASTERVERIFY IN FIELDVERTICALVINYL COMPOSITION TILEVINYL WALL COVERINGV.P.V.I.F.VERT.VCT.VWC.WATER CLOSETWATERPROOFINGWELDED WIRE FABRICWIDE FLANGEWINDOWWITHWITHOUTWOOD2021-06-08: ADD CMU TOBASE OF EXTERIOR EET NO.ATS

EXISTING ROOF VENTS12ASPHALT ROOF SHINGLES4ADD 1 ROW OF CMUTO BOTTOM OFALL EXTERIOR WALLS41A100A100NEW DOOR INEXISTING OPENINGREMOVE EXISTING WINDOW,INFILL w/ 2x4 @ 16" O.C.,INSULATE WALL,AND PATCH SIDINGEXISTING T1-11 SIDING,PATCH AND REPLACEAS NECESSARY. REPAINTENTIRE EXTERIOR.TOP OF SLABELEV: 100'-0"REMOVE EXISTING WINDOW,INFILL w/ 2x4 @ 16" O.C.,INSULATE WALL,AND PATCH SIDINGEAST ELEVATIONSCALE: 1/4" 1'-0"32'-0"12'-0"15'-0"FILL IN EXISTINGDOOR OPENING6'-3"5'-0"HI AND LOWDRINKINGFOUNTAINSHOSEBIB53 1/2"12'-1"FILL IN EXISTINGDOOR OPENINGEXISTING ROOF VENTS1A10287 1/4"ASPHALT ROOF SHINGLES12412'-1"0"295 MIDDLE ROAD, LAPOINTE, WI 54850SLOPE GRADE AWAYFROM BUILDING AT 2%PROPOSED RENOVATIONS FOR:PREFINISHED METALSOFFIT w/ VENTLAPOINTE REC CENTERTRUSS BEARINGELEV: 108'-0"WATERHEATER103MEN'SPRESSURETANKFILL IN EXISTINGWINDOW OPENINGFILL IN EXISTINGWINDOW OPENING2x8 @ 16" O.C. PLUMBING WALL12'-0" x 17'-10"1A101104WOMEN'SUTILITY SINK12'-0" x 17'-10"SLOPE GRADE AWAYFROM BUILDING AT 2%2A101POSSIBLE AREAOF DEEPER FOOTING102UTILITY4A1006'-1" x 17'-10"32'-0"FILL IN EXISTINGWINDOW OPENING343'-2"3 1/2"REMOVE EXISTING WINDOW,INFILL w/ 2x4 @ 16" O.C.,INSULATE WALL,AND PATCH SIDINGFILL IN EXISTINGWINDOW OPENING105STORAGE73 1/2"16'-3"3 1/2"5'-1"3 1/2"6'-8 1/2"REMOVE EXISTING WINDOW,INFILL w/ 2x4 @ 16" O.C.,INSULATE WALL,AND PATCH SIDINGNEW DOOR INEXISTING OPENINGADD 1 ROW OF CMUTO BOTTOM OFALL EXTERIOR WALLSWEST ELEVATION3A1006'-7" x 3'-0"EXISTING T1-11 SIDING,PATCH AND REPLACEAS NECESSARY. REPAINTENTIRE EXTERIOR.803 Lake Shore Drive West, Ashland, WI 54806Telephone (715) 682-0330 www.csdesignengineering.com17'-11 1/4"PREFINISHED METALSOFFIT w/ VENT3A100SCALE: 1/4" 1'-0"7 1/4"6ALL INTERIOR WALLSARE NEW CONSTRUCTION,ALL EXTERIOR WALLS AREEXISTING22" x 36" ATTICACCESS PANELSEE DETAIL 3/A101LOCATION V.I.F.TO WORK WITHEXISTING TRUSSES2EXISTING ROOF VENTSASPHALT ROOF SHINGLES12413'-1"101RECREATION ROOM10'-0"10'-0"31'-2" x 13'-0"NORTHPREFINISHED METALSOFFIT w/ VENTASCALE:ADD 1 ROW OF CMUTO BOTTOM OFALL EXTERIOR WALLSFLOOR PLAN1'-0"EXISTING T1-11 SIDING,PATCH AND REPLACEAS NECESSARY. REPAINTENTIRE EXTERIOR.NEW WINDOWS INEXISTING OPENING, TYP.DATE:A100SCALE: 1/4" AS NOTEDJUNE 2021PROJECT NO.SOUTH ELEVATION2A.D.E.A.D.E.SLOPE GRADE AWAYFROM BUILDING AT 2%2A100SCALE: 1/4" DESIGNED:DRAWN:A19-33841'-0"REVISIONS:EXISTING ROOF VENTSASPHALT ROOF SHINGLES124APPROVED:PREFINISHED METALSOFFIT w/ VENTADD 1 ROW OF CMUTO BOTTOM OFALL EXTERIOR WALLS1A100NEW DOORCUT INTOEXISTING WALLMAX. 43"AMAX 36" Copyright 2019 C&S Design & Engineering, Inc, all rights reserved. Any use without permission is expressly prohibited. Plotted 6/8/2021 10:40 AMFLOOR PLAN & ELEVATIONS0"REMOVE EXISTING DOOR,NEW DOORINFILL w/ 2x4 @ 16" O.C.,CUT INTOINSULATE WALL,EXISTING WALLAND PATCH SIDINGNORTH ELEVATIONSCALE: 1/4" 1'-0"SLOPE GRADE AWAYFROM BUILDING AT 2%REMOVE EXISTING DOOR,INFILL w/ 2x4 @ 16" O.C.,INSULATE WALL,AND PATCH SIDINGEXISTING T1-11 SIDING,PATCH AND REPLACEAS NECESSARY. REPAINTENTIRE EXTERIOR.SHEET NO.A100

INTERIOR ROOM FINISH SCHEDULECONCRETE SEE NOTE 44" VINYL5/8" GYPSUM BOARDPAINT5/8" GYPSUM BOARDPAINT8'-0"UTILITYCONCRETE4" VINYL5/8" W.R. GYPSUM BOARD PAINT /FRP PANEL OVER WALLPREBEHIND MOP SINKFINISHED5/8" GYPSUM BOARDPAINT8'-0"103MEN'S RESTROOMCONCRETE6" VINYLFRP PANELS OVERPRE5/8" W.R. GYPSUM BOARD FINISHED5/8" W.R. GYPSUM BOARDPAINT8'-0"104WOMEN'S RESTROOMCONCRETE6" VINYLFRP PANELS OVERPRE5/8" W.R. GYPSUM BOARD FINISHED5/8" W.R. GYPSUM BOARDPAINT8'-0"105CLOSETCONCRETE4" VINYL5/8" GYPSUM BOARDPAINT8'-0"1021'-0"SEE ROOM FINISH SCHEDULEFOR FLOOR FINISHESCONNECT BLOCK TO FOUNDATIONw/ #4 REBAR DRILLED INTO SLABAND GROUTED IN CMU @ 48" O.C.WINDOW SCHEDULEMECHANICALLY FASTEN ASNECESSARY IN CORNERSEXISTING FOUNDATION SYSTEMCORNER FLASHING PATCHSYMBOLQTYTYPEUNITSIZE (WxH)A3DOUBLE HUNGWINDOW3'-8" x 4'-5"SEALANT TERMINATIONTYP. EXTERIOR WALL SECTION1A101SCALE: 1/2" 1.2.SELF-ADHERED WINDOW FLASHING3.4.5.6.7.1'-0"3SECURE TOP PLATE TO RAFTERSGLASS INSUL. HEADERTYPEHEIGHTLOW E W/ARGONDOORGLASSFINISHD-1STEEL3'-0"x6'-8"x 1 3/4"D-1SEE ROOM FINISH SCHEDULEFOR INTERIOR WALL COVERING2.3.3 1/2" BATT SOUND INSULATION2x4 STUDS @ 16" O.C. FOR ALLINTERIOR WALLS UNLESSOTHERWISE NOTED1013'-0"x6'-8"x 1 3/4"41015WINDOW FLASHING DETAILSCALE: 1 1/2" FOLLOW MFR MOST CURRENT DETAILS AND INSTALLATIONINSTRUCTIONS FOR FLASHING.INSTALL FLASHING IN ORDER AS SHOWN BY NUMBERSINSTALL A COMPATIBLE SEALANT TO TOP LEADING EDGEOF HEAD FLASHING5A101BOTTOM PLATE TO BE TREATED WOODSEE ROOM FINISH SCHEDULEFOR FLOOR FINISHESTYP. INTERIOR WALL "x 1 AIN1'-0"1'-0"DO NOT FLASH OVERBOTTOM NAILING FLANGE3'-0"x6'-8"x 1 3/4"D-2WOODEXT.3'-0"x6'-8"x 1 3/4"D-161013'-0"x6'-8"x 1 3/4"71018EXT.HEADERHEIGHTHEADERSIZEHARDWARELOCK FUNCTIONRHREXISTINGKEYED ENTRYLOCKSETw/ LEVER HANDLE, PANIC HARDWARE, CLOSER,AND WEATHER STRIPPINGSTEELPAINTRHREXISTINGKEYED ENTRYLOCKSETw/ LEVER HANDLE, PANIC HARDWARE, CLOSER,AND WEATHER STRIPPINGF-2WOODSTAINLHKEYED ENTRYLOCKSETw/ CLOSER, & DOOR STOPSTAINF-2WOODSTAINLHKEYED DEADBOLT(KEYED BOTH SIDES)w/ PUSH PLATE, PULL HANDLE, CLOSER,& DOOR STOPSTEELPAINTF-1KEYED DEADBOLTSEE NOTE 3w/ PUSH PLATE, PULL HANDLE, CLOSER,& DOOR STOP AND WEATHER STRIPPINGD-2WOODSTAINF-2WOODSTAINRHRKEYED ENTRYLOCKSET3'-0"x6'-8"x 1 3/4"D-2WOODSTAINF-2WOODSTAINRHKEYED DEADBOLT(KEYED BOTH SIDES)w/ PUSH PLATE, PULL HANDLE, CLOSER,& DOOR STOP3'-0"x6'-8"x 1 3/4"D-1STEELPAINTF-1STEELPAINTLHRKEYED DEADBOLTSEE NOTE 3w/ PUSH PLATE, PULL HANDLE, CLOSER,& DOOR STOP AND WEATHER STRIPPINGRHR2 PLY 2x102 PLY 2x10REMARKS1. CONTRACTOR SHALL VERIFY ALL SIZES WITH MANUFACTURER BEFORE ORDERING OR INSTALLING.2. EQUIP ALL EXTERIOR AND INTERIOR DOORS TO PROVIDE A COMPLETE INSTALLATION, INCLUDING ALL REQUIRED: JAMB, HINGES, LEVER STYLE HANDLE, CASING,LOCK(S), WEATHER-STRIPPING, THRESHOLDS, SWEEPS, DOOR STOPS w/ BACKING, ETC. SIZE AND SWING AS INDICATED ON THE PLANS.3. ALL DEADBOLTS TO HAVE THUMB TURN INSIDE TO UNLOCK ONLY, LOCK BY KEY ON EXTERIOR ONLY, UNLESS OTHERWISE NOTED .4. STEEL DOORS TO BE CURRIES 707 SERIES w/ POLYURETHANE CORE 16 GAUGE FACES, 14 GAUGE STEEL FRAME OR EQUAL.5. WOOD DOORS TO BE SOLID CORE FLUSH PANEL w/ OAK VENEER, PREFINISHED, STAIN COLOR SELECTED BY OWNER / ARCHITECT.6. ALL HARDWARE TO BE SATIN NICKEL, LEVER STYLE, HEAVY DUTY COMMERCIAL GRADE SARGENT, SCHLAGE OR EQUAL.7. ALL LOCKS TO BE KEYED TO ONE MASTER KEY; ADDITIONALLY, KEY SET 1 TO INCLUDE DOORS 1 AND 2, KEY SET 2 TO INCLUDE ALL OTHER DOORS.8. INTERIOR DOORS TO HAVE STAINED 3" WOOD TRIM IN A STANDARD RANCH PROFILE, MITER CORNERS.3'-4"3'-0"3'-0"3'-0"3'-0" Copyright 2019 C&S Design & Engineering, Inc, all rights reserved. Any use without permission is expressly prohibited. Plotted 6/8/2021 10:40 AM6'-8"6'-8"6'-8"5 LAYERS OF 2" RIGIDINSULATION ADHEREDW/ CONSTRUCTION ADHESIVE6'-8"6'-10"2"SCALE: 1/2" KEYEDSIDENAILING FLANGE BELOWNOTES:2SYM21.DOOR SIZE DOORTYPE(WxHxT)DOORMAT.DOUBLE TOP PLATEREPLACE EXISTING WINDOWS,FIELD VERIFY SIZE BEFORE ORDERINGDOOR SCHEDULE1SEE ROOM FINISH SCHEDULEFOR CEILING COVERING / FINISHEXISTINGCOMMENTSCONTRACTOR SHALL VERIFY ALL SIZES WITH MANUFACTURER BEFORE ORDERING OR INSTALLING.ALL WINDOWS TO BE VINYL CLAD WOOD AND HAVE INTERIOR WOOD STAINED AND POLY IN COLOR SELECTED BY OWNER,EXTERIOR COLOR TO BE SELECTED BY OWNER FROM MFR STANDARD COLORS.INTERIOR OF WINDOW TO HAVE STAINED 3" WOOD TRIM IN A STANDARD RANCH PROFILE, BY OWNER.EXTERIOR OF WINDOW TO HAVE 1"x3" ENGINEERED WOOD TRIM PAINTED TO MATCH SIDING.INCLUDE REMOVABLE INSECT SCREEN WITH ALL OPERABLE WINDOWS.PROVIDE TEMPERED GLASS AT WINDOWS WITHIN 24" OF DOORWAYS AND ELSEWHERE AS REQUIRED BY CODE.SEE DETAIL 5/A101 FOR FLASHING DETAIL AT ALL NEW EXTERIOR WINDOWS.26 MIL. POLY VAPOR BARRIEREXISTINGHEADERSIZE803 Lake Shore Drive West, Ashland, WI 54806Telephone (715) 682-0330 www.csdesignengineering.comADD ANCHOR BOLTS GROUTEDINTO BLOCK @ 48" O.C. AROUNDENTIRE BUILDING PERIMETERPAINTNOTES:1. ALL PAINTING: PRIMER WITH TWO (2) FINISH COATS OF PAINT.2. ALL CLOSETS TO HAVE SAME FINISHES AS THE ROOMS THEY ARE ASSOCIATED WITH.3. OWNER WILL BE INSTALLING EPOXY FLOORING OVER CONCRETE. CONTRACTOR TO LEAVE CONCRETECLEAN AND BLEND IN NEW CONCRETE SURFACES WITH ADJACENT AREAS AS MUCH AS POSSIBLE.WINDOW TRIM DETAILSCALE: 1/2" 5/8" GYPSUM BOARDPROPOSED RENOVATIONS FOR:A101FINISHMITER ALL CORNERSINTERIOR TRIM4SUBSTRATEDETAILS & SCHEDULESHEIGHTRECREATION ROOMSEE ROOM FINISH SCHEDULEFOR INTERIOR WALL COVERINGADD 1 ROW OF 6" CMU TO BOTTOMOF ALL EXTERIOR WALLSNEW TREATED 2x4 BOTTOM PLATEFINISH1016 MIL. POLY VAPOR BARRIEREXISTING 2x4 EXTERIOR WALLSUBSTRATESEE ROOM FINISH SCHEDULEFOR CEILING COVERING / FINISHEXTERIOR TRIMCOMMENTSFINISHNAMEINSULATE ENTIRE EXTERIORWALL w/ MIN. 3 1/2" F.B. INSULATION (R-11)PATCH IN T1-11SHEATHING/SIDINGTO MATCH EXISTINGCEILINGSUBSTRATENO.INFILL EXISTING OPENING w/2x STUDS @ MAX. 16" O.C.DEPTH TO MATCH EXISTINGWALL, V.I.F.WALLBASEFINISH6 MIL. POLY VAPOR BARRIEREXISTING WINDOWHEADER TO REMAINREPAINT ENTIREEXTERIOR IN COLORSELECTED BY OWNERFLOORROOM295 MIDDLE ROAD, LAPOINTE, WI 54850INTERIOR TRIM BY OWNER:NOM. 3" RANCH PROFILE CASING,TYP FOR SILL, JAMB AND HEAD CASINGLAPOINTE REC CENTER3"x1" ENGINEERED WOODTRIM BOARD, TYP FORSILL, JAMB AND HEAD TRIMINSTALL BLOWN-INF.G. INSULATIONTO MIN. R-50DESIGNED:A.D.E.16" HIGH 3/4" PLYWOODDRAWN:1/4" MIN. TO 1/2" MAX. GAPF-1HOLLOWMETALTRUSS BOTTOM CORDF-2PRE-HUNGWOODD-1INSULATEDHOLLOWMETALD-2SOLID COREWOODSCALE:DATE:A.D.E.AS NOTEDJUNE 2021PROJECT NO.1x4 WOOD STRIPCEILING19-33841/2" FOAM SEAL5/8" PAINTED A/C PLYWOODCEILINGREVISIONS:3A101ATTIC ACCESS DETAILSCALE: 1 1/2" 1'-0"APPROVED:SHEET NO.A101

MIN. 32" CLEAR OPENING40" ABOVE FINISHED FLOORBOBRICK B-6806x 18SATIN FINISHCONTRACTOR CONTRACTORDTOILETPAPER DISPENSERHORIZONTAL CENTERLINE30" ABOVE F.F.OWNERCONTRACTORESANITARY NAPKINDISPOSALTOP OF UNIT25" ABOVE F.F.OWNERCONTRACTORFACCESSIBLE 24" x 36"MIRRORBOTTOM EDGE OF REFLECTIVESURFACE TO BE 40" ABOVE F.F.GACCESSIBLE SIGNAGEFOR RESTROOMBOTTOM EDGE TO BE 48"ABOVE F.F.HELECT. AIR HAND DRYERHORIZONTAL CENTERLINE44" ABOVE F.F.OWNEROWNER, SEENOTE 5ISURFACE-MOUNTEDSOAP DISPENSERHORIZONTAL CENTERLINE44" ABOVE F.F.OWNERCONTRACTORJBABY CHANGINGSTATIONHORIZONTAL CENTERLINE42" ABOVE F.F.SANITARY NAPKINDISPENSER42" ABOVE F.F. TO HIGHESTUSER INTERFACEKNOTES:1.2.3.4.5.BOBRICK B-165 2436FCONTRACTOR CONTRACTOR2x8 @ 16" O.C. PLUMBING WALL17" ADA COMPLIANTRIM HEIGHTCONTRACTOR CONTRACTOR30" MIN.FIF48" MIN.48" MIN.48" MIN.EDCONTRACTOR A KARE KB200ELECT.HANDDRYERFIACBKALL ACCESSORIES TO HAVE BLOCKING IN THE WALL.ALL HARDWARE SHALL BE HEAVY DUTY USE.PROVIDE 3/4" PLYWOOD BACKING BEHIND ALL GRAB BARS.MANUFACTURER TO BE BOBRICK, BRADLEY OR EQUAL.CONTRACTOR TO PROVIDE ELECTRICAL ROUGH-IN FOR HAND DRYER.5'-0"36" SELF-CLOSING DOORED3'-0"TOILET COMPARTMENTSBACD5'-0"1'-0"FLOOR MOUNTEDPARTITION WALLS16" TO 18"Panels, doors, and pilasters shall be fabricated from High Density Polyethylene (HDPE)containing a minimum of 10% recycled material manufactured under high pressure forming asingle component section which is waterproof, nonabsorbent, and has a self-lubricatingsurface that resists marking with pens, pencils, or other writing utensils.2'-0"DISPENSER7" TO 9"5'-0"Toilet compartments shall be floor-mounted, overhead-braced, with noncorrosive doors, panels,and pilasters similar and equal to Hiny Hiders compartments as manufactured by Scranton Products,or an equal with hardware as specified herein.E36" SELF-CLOSING DOORMIRRORDoors, panels, and pilasters shall be a minimum of 1” thick and all edges machined to a radiusof .250” and all exposed surfaces to be free of saw marks.39" TO 41"TO VERTICAL BAR105STORAGEBABY CHANGINGSTATIONColor of doors, panels, and pilasters to be selected from the standard color range.2'-0"ELECTRICHAND DRYERSOAPDISPENSER16" TO 18"Pilasters shall be 82” high, mounted within a one-piece plastic shoe with one-way theft-proof,stainless steel sex bolts.SOAPDISPENSER1'-0"BOTTOM EDGE OFREFLECTIVE SURFACE1'-0"5'-0"B3'-6"Dividing panels and Doors shall be 55” high and mounted at 14” above finished floor.DCFLOOR MOUNTEDPARTITION WALLSA3'-0"27" MIN.34" MAX.40" MAX.INSTALL PER MFRINSTRUCTION FORADA REQUIREMENTS44"3'-0"Aluminum edging strips to be fastened to the bottom edge of all doors and panelsusing vandal-proof stainless steel fasteners.MIN. 32" CLEAR OPENING1'-0"MAX.G3'-6"GELEVATION AH/C RESTROOMS DETAILED PLANA102STALL PARTITIONSSCALE: 1/2" 1'-0"STALL PARTITIONSWOMEN'SRESTROOMMIRRORSIGN MUST BE COMPLIANT WITHADA (AMERICANS w/ DISABILITIES) STANDARDSSIGN MUST HAVE A NON-GLARE FINISH,AND CONTRAST WITH THE BACKGROUND,WITH EITHER A LIGHT SYMBOL ON A DARKBACKGROUND OR THE REVERSE.BOTTOM EDGE OFREFLECTIVE SURFACESOAPDISPENSERSOAPDISPENSERELECTRICHAND DRYERDESIGNED:PICTOGRAM FIELD SHOULDINCLUDE UNIVERSAL SIGN FORWOMEN AND HANDICAP ACCESSIBILITYTACTILE / RAISED CHARACTERSWOMENMIN. 32" CLEAR OPENING39" TO 41"TO VERTICAL BARPROVIDE PROTECTIVECOVER OVER ANYEXPOSED PIPING136" MIN.2'-0"1'-0"1'-0"36" MIN.2'-0"DRAWN:A.D.E.A.D.E.STANDARDRIM HEIGHTSIGN MUST HAVE A NON-GLARE FINISH,AND CONTRAST WITH THE BACKGROUND,WITH EITHER A LIGHT SYMBOL ON A DARKBACKGROUND OR THE REVERSE.ADA COMPLIANTRIM HEIGHT44"27" MIN.34" MAX.40" MAX.16" - 18"PROVIDE PROTECTIVECOVER OVER ANYEXPOSED PIPINGDATE:AS NOTEDJUNE 2021PROJECT NO.ELEVATION BPICTOGRAM FIELD SHOULDINCLUDE UNIVERSAL SIGN FORMEN AND HANDICAP ACCESSIBILITYTACTILE / RAISED CHARACTERSMEN16" - 18"33" MIN.17" - 19"SIGN MUST BE COMPLIANT WITHADA (AMERICANS w/ DISABILITIES) STANDARDS17"2'-0"6" HIGHNONABSORBENTBASEBOARDSCALE:17" - 19"MEN'SRESTROOM33" MIN.GRADE II BRAILLE19-3384ELEVATION ASTALL PARTITIONSREVISIONS:STALL PARTITIONSGRADE II BRAILLEPROVIDE SOLIDBLOCKING IN WALLSBEHIND GRAB BARSTYPICALCLEAR FLOOR AREACENTERED ON SIGNPROVIDE SOLIDBLOCKING IN WALLSBEHIND GRAB BARSTYPICAL39" TO 41" MAX.42" MIN.42" MIN.MIN. 1.5"ELEVATION CSANITARYNAPKINDISPENSERBABY CHANGINGSTATIONAPPROVED:DISPENSERINSTALL PER MFRINSTRUCTION FORADA REQUIREMENTS7 TO 9"INSTALL PER MFRINSTRUCTION FORADA REQUIREMENTS17" - 19"36" MAX.39" TO 41" MAX.33" MIN.39" TO 41" MAX.36" MAX.33" MIN.30" (MIN 15")7 TO 9"12"MAX.MIN. 1.5"DISPENSERSIGNAGE CHARACTERS MUST BE 48" MIN. TO 60" MAX.ABOVE THE ADJACENT FLOOR OR GROUND LEVELMEASURED FROM THE BASELINE OF THE CHARACTERS.39" TO 41" MAX.30" (MIN 15")12"MAX.17" - 19"LATCH SIDEOF DOOR1'-6"SIGN MUST BE ALONGSIDE THE DOOR ON THE LATCHSIDE. WHERE THERE IS NO WALL SPACE ON THE LATCHSIDE OF A SINGLE DOOR, SIGNS MUST BE ON THE NEARESTADJACENT WALL. SIGNS CONTAINING TACTILE CHARACTERSMUST HAVE AN 18" MIN x 18" MIN CLEARANCE ON THE FLOOROR GROUND LEVEL CENTERED ON THE SIGN, BEYONDTHE ARC OF ANY DOOR SWING.1'-6"1'-6"MINIMUM 48"MAXIMUM 60" Copyright 2019 C&S Design & Engineering, Inc, all rights reserved. Any use without permission is expressly prohibited. Plotted 6/8/2021 10:40 AM2CA102DETAILS & SCHEDULES1 1/2" DIA. 18" GRAB BARW/ NONSLIP TEXTUREHGARBAGE CAN(BY OWNER)803 Lake Shore Drive West, Ashland, WI 54806Telephone (715) 682-0330 www.csdesignengineering.comCI295 MIDDLE ROAD, LAPOINTE, WI 54850CONTRACTOR CONTRACTORLAPOINTE REC CENTERBOBRICK B-6806x 36SATIN FINISH3'-8"34.5" ABOVE FINISHED FLOOR104WOMEN'S5'-2"1 1/2" DIA. 36" GRAB BARW/ NONSLIP TEXTURE103MEN'SELECT.HANDGARBAGE CAN DRYER(BY OWNER)60"MIN.BH30" MIN.CONTRACTOR CONTRACTOR3'-0"BOBRICK B-6806x 42SATIN FINISH3'-0"3'-0"34.5" ABOVE FINISHED FLOORMIN. 32" CLEAR OPENING3'-0"30" MIN.1 1/2" DIA. 42" GRAB BARW/ NONSLIP TEXTUREAGHOSEBIB60"MIN.MFR'SSUPPLIED INSTALLEDCATALOG No.BYBY3'-0"MOUNTING HEIGHTSYM. DESCRIPTIONHI AND LOWDRINKINGFOUNTAINSGPROPOSED RENOVATIONS FOR:BATHROOM ACCESSORY SCHEDULEELEVATION BELEVATION CSHEET NO.4A102H/C RESTROOM SIGNAGESCALE: 1/2" 1'-0"3A102MEN'S RESTROOM ELEVATIONSSCALE: 1/2" 1'-0"2A102WOMEN'S RESTROOM ELEVATIONSSCALE: 1/2" 1'-0"A102

DF-2APPROX. LOCATION OFEXISTING 4" WASTE LINETO CITY SANITARYEXISTING BUILDING CLEANOUTPLUMBING FIXTURE SCHEDULEDF-1HB-1H/C WATERCLOSET2DFUTOTALWSFUTOTALREMARKSTIE INTO EXISTING 4" SANITARYSEWER TO CITY 55-U2244FD-14" C.O.102UTILITY32"URINALFLUSH VALVE2ZURNZ6003AV---PROVIDE HANGER BRACKET;MOUNT AT 24" LIP HEIGHT UR-2 AND17" LIP HEIGHT UR-1SEE RESTROOM ELEVATIONS 1ZURNZ6956-XL-41-4-MB-11INSTALL @ 34" HEIGHT ABOVE FF.-1.5"3"MB-11.5"3333ZURNZ843M1-5H8" VACUUM BREAKER SPOUT-ZURNZ415B31FIATFL-1 SERV-A-SINK22331ZURNZ812J1-XL----MOP BASINFAUCET1FD-13" FLOORDRAIN3S-1SERVICESINKSINKFAUCET----PLUMBING WASTE PLANWALLHYDRANTDF-1DF-2EWH-1PT-1WOODFORDMODEL ER1BRADFORD WHITEMODEL LE 2303-3----PROVIDE APPROVEDBACKFLOW PROTECTION.25.5MOUNT DF-1 AT 36" MAX HEIGHT,AND DF-2 AT 43" MAX HEIGHT,BOTH MEASURED OFF THE GROUND--PROVIDE T&P OVERFLOW& VALVE TO 6" OF FLOORWC-21EXISTING TO BE REUSEDGOULDSV100366334"21WATER SUPPLY FIXTURE UNITS(TYPICAL)186WC-13"----WC-23"3WC-2FD-164" C.O.4"3"WC-3PLUMBING WASTE RISER E 5' VINYL HOSEPROVIDE APPROVEDBACKFLOW PROTECTION3"1.5"6FD-1PROVIDE APPROVEDBACKFLOW PROTECTIONDF-1433"3"94"2"4"83"4" C.O.4" C.O.101RECREATION ROOMFIAT MSB-24241.5"23324"x24"MOLDEDMOP BASINL-12"2"2"DF-24"1L-1S-1-WC-3SCALE: 1/4" WOMEN'SWC-2WATERCLOSETPROVIDE BEMIS 1655-SS/C OPENFRONT SEAT; 15" BOWL HEIGHT; 1.6 gpfHANDLE ON OPEN SIDE OF STALLNOT TO SCALECONTRACTOR TO REPLACEPRESSURE SWITCH1'-0"3/4"TOTALS:SEE WASTE RISER DIAGRAM 1/P100 FOR SIZING5332.56NOTES: 1. ALL FIXTURES SHALL BE WHITE.2. ALL FAUCETS SHALL BE POLISHED CHROME.3. PROVIDE ALL NECESSARY ACCESSORIES, VALVES AND TRAPS, ETC. NECESSARY FOR A FULL INSTALLATION OF LISTED FIXTURESEWH-1PPT-1803 Lake Shore Drive West, Ashland, WI 54806Telephone (715) 682-0330 www.csdesignengineering.comL-1FD-1TIE INTO EXISTING 3" VSTRPROVIDE BEMIS 1655-SS/C OPENFRONT SEAT; 17.5" BOWL HEIGHT; 1.6 gpfWC-3 TO BE RIGHT HAND HANDLEPLUMBING PLANWC-1WC-3L-1CATALOGNO.295 MIDDLE ROAD, LAPOINTE, WI 54850UR-2L-1QTY.LAPOINTE REC CENTERTIE INTO EXISTING4" WASTEEWH-1TYPE OFFIXTUREPROPOSED RENOVATIONS FOR:SYMRECIRCULATING PUMP,SEE DETAIL 4/P100RECIRCULATING LINE3/4"32.5HOT WATER LINE6EXISTING 1" TYPE"K" COPPER FROMEXISTING WELL23.56COLD WATER LINEDF-2SHUT OFFVALVE (TYP.)UNION(TYP.)DF-1RECIRCULATING PUMP,SEE DETAIL 4/P100PEWH-1UR-2L-1RECIRC. PUMPSEE DETAIL 4/P100L-1TEMPERATURE &PRESSURE RELIEFVALVE TO WITHIN6" OF FLOORPT-1 Copyright 2019 C&S Design & Engineering, Inc, all rights reserved. Any use without permission is expressly prohibited. Plotted 6/8/2021 10:40 AML-1L-1S-11/2"4.5UR-13/4"4TYP. ALL L-1, S-1, MB-12P100WC-13WATER SUPPLY FIXTURE UNITS(TYPICAL)WATER HEATER31"20181/2"3/4"WC-2SCALE: 1/4" TYP. ALL WC-1,2,321'-0"P100WC-1DRAWN:WC-3DATE:PLUMBING SUPPLY RISER DIAGRAMNOT TO SCALEA.D.E.AS NOTEDJUNE 2021PROJECT NO.19-3384WC-3PLUMBING LEGENDFLOW DIRECTIONCALIBRATED BALANCE VALVECHECK VALVE101RECREATION ROOMINLINE CIRCULATINGPUMPNORTHPUNION(TYP.)SHUT OFF VALVE(TYP.)PLUMBING SUPPLY PLANSCALE: 1/4" A.D.E.WC-2SCALE:1/2"WATER HEATER -13/4"3/4"PROVIDE APPROVEDBACKFLOW TION OFEXIST

Jun 06, 2021 · fixture flashing floor flooring floor plan footing foundation fluorescent galvanized gauge general contractor glass gypsum gypsum wallboard handicap accessible hardware heater heating, venting, and air conditioning height high point hollow core hollow metal horizontal hour incandescent inch i