2021 Business Prescriptive ProgramMeasure Selection Form: Heating & Coolingfor Indiana Businesses with CenterPoint Energy Electric Service Complete this Measure Selection Form All installed equipment must be ENERGYto apply for an incentive for the installationSTAR qualified unless otherwise noted.of eligible “Heating & Cooling” measures For new construction or majorinstalled by December 31, 2021.renovation installations: All technical data sheets for installed»» A baseline equipment specificationequipment must be included with yourmust be provided in lieu of existingsubmission.equipment information. The baseline If technical data (EER, Efficiency, etc.)requested in the form is unavailable,please contact your product supplier.Incomplete forms will not be processed. All installed measures must be new. Norefurbished measures will be accepted.equipment must meet any and allapplicable building codes as they referto efficiency levels and should meetASHRAE 90.1 standards.»» Rebates are only available forequipment which exceeds ASHRAE90.1 standards.ImportantThis Measure Selection Form and technicaldata sheets should be submitted inconjunction with the Program Application.Only complete this form if you: Have completed the BusinessPrescriptive Program Applicationand have ensured your eligibility forrebates; and Are applying for heating &cooling measures as part of yourparticipation in CenterPoint Energy’sBusiness Prescriptive Program.Applications for rebates in excess of 20,000 per facility per year must be preapproved by CenterPoint Energy prior topurchasing or installing equipment.Need Help?For assistance completing this Measure Selection Form, call 1-866-240-8476 to speak with a CenterPoint Energy program representative.Project & Facility InformationRequired InformationPlease select the heating and cooling and building type where all measures are being installed. If measures are being installed inmore than one building type, please complete additional measure selection forms.Project Type Retrofit Existing Equipment Replace Failed Equipment New Load New Construction or Major RenovationHeating/Cooling Type AC with Natural Gas Heat AC with Electric Heat Heat Pump Electric Heat Only Natural Gas Heat OnlyBuilding Type Auto Repair Agricultural Education (preK - 12) Education (College) Food Service (Fast Food) Food Service (Full Service Grocery Health Care (Inpatient) Health Care (Outpatient) Hotel/Motel (Common Areas) Hotel/Motel (Guest Room) Industrial/Manufacturing Office (Small 50,000 sf) Office (Large 50,000 sf) Parking Garage Public Assembly Religious Worship Service Retail (Small 50,000 sf) Retail (Large 50,000 sf) Warehouse/Storage 866.240.84762021 Indiana Business Prescriptive Program Electric Measure Selection Form: Heating & Cooling 05.25.21

2021 Business Prescriptive for Indiana Businesses with CenterPoint Energy Electric ServiceProduct & Facility Information (cont.)Packaged Terminal Air Conditioners & Packaged Terminal Heat PumpsEquipment meeting only one of the required minimum efficiency levels is eligible for the respective incentive.Ref IDEquipment TypePT-01PT-02Equipment Size 7,000 Btu/hr (0.58 tons)Packaged Terminal AirConditioner or HeatPump (PTAC or PTHP)PT-037,001 Btu/hr (0.58 tons) 15,000 Btu/hr (1.25 tons) 15,000 Btu/hr (1.25 tons)Min.EfficiencySize(Tons)QuantityIncentive(Per Ton)Total Tons Cooling: 30 Heating: 100 Cooling: 30 Heating: 100 Cooling: 30 Heating: 10013.2 EER2.7 COP12.2 EER2.6 COP11.2 EER2.5 COPTotal Incentive Air Conditioners and Heat PumpsThe air conditioner measure applies to split system, rooftop unit, and ductless mini-split air conditioning units.Ref IDEquipment TypeEquipment SizeMin.Efficiency 65,000 Btu/hr (5.4 tons)AC-0265,000 Btu/hr (5.4 tons) 134,999 Btu/hr (11.3 tons)12.0 EERAC-03135,000 Btu/hr (11.3 tons) 239,999 Btu/hr (20 tons)11.7 EERAC-04 240,000 Btu/hr (20 tons)HP-01 17,000 Btu/hr (1.42 tons)Water Source HeatPumpHP-02HP-03Ground Source HeatPumpQuantity Cooling: 30 Heating: 10 Cooling: 30 Heating: 10 Cooling: 30 Heating: 10 Cooling: 30 Heating: 10 Cooling: 30 Heating: 10 Cooling: 30 Heating: 10 Cooling: 30 Heating: 108.5 HSPF3.6 COP3.5 COP10.5 EER3.5 COP12.3 EER4.6 COP17,000 Btu/hr (1.42 tons) 135,000 Btu/hr (11.25 tons)13.2 EER 135,000 Btu/hr (11.25tons)14.7 EERIncentive(Per Ton)Total Tons14.3 SEERAC-01Air Conditioner orAir Source Heat PumpSiz(Tons)4.6 COP3.4 COPTotal Incentive Window or Room Air ConditionersRef IDAC-06AC-07Equipment TypeEnergy Star Window or Room AirConditionerEquipment SizeUnitSizeIncentive(Per Unit)QuantityTotal Incentive 14,000 Btu/hrEach 12 14,000 Btu/hrEach 14 Window FilmFilm must block at least 60% of solar heat, and have a Solar Heat Gain Coefficient (SHGC) 0.4.Ref IDWIN-01Equipment TypeWindow tive(Per Unit)Glazing Surface Area (exclude frame area)ft2 1Total Incentive 866.240.84762021 Indiana Business Prescriptive Program Electric Measure Selection Form: Heating & Cooling 05.25.21

2021 Business Prescriptive for Indiana Businesses with CenterPoint Energy Electric ServiceProduct & Facility Information (cont.)Water HeaterThis measure does not apply for replacement of natural gas-fired water heaters.Equipment HeatingCapacity RequirementRef IDEquipment TypeWH-01Heat Pump Water HeaterVolume of Water Tank(Gallons) 10 MBHUnitHeating Capacity (MBH)Rated Efficiency (COP)EachHot Water TemperatureSetpoint FIncentive(Each)Quantity 500Total Incentive Advanced Rooftop ControlsRooftop Unit(RTU) SizeRTU Size (Tons)RTU Make and ModelSupply Fan HPIncentive(Per RTU)RTU QtyTotal Incentive 5 Tons and 10 Tons 800 10 Tons and 15 Tons 1,500 15 Tons and 20 Tons 2,000 20 Tons 4,000 Control must include CO2 sensor or occupancy sensor to determine ventilation and space conditioning needs (i.e. demand control ventilation) Control must be installed on existing unitary package rooftop unit (no split-systems) Existing rooftop unit must be less than 15 years old (based on manufacture date) Control must replace constant speed fan motor with either a supply fan VFD or multi-speed supply fan motor with controller that meets ventilation and space conditioning needs Control must include digital, integrated economizer controls RTUs 5 tons are ineligible New construction or major renovation projects should apply for a custom rebate in order to confirm eligibilityVariable Frequency DrivesThe rebate applies to a variable frequency drives installed on an HVAC system pump or fan motor up to 100 hp. VFDs installed in otherapplications or those larger than 100 hp should be submitted for preapproval through CenterPoint Energy’s Custom Program prior topurchase. For New Construction Program participants, VFDs on fans less than 10 hp, VFDs on pumps less than or equal to 50 hp, andVFDs on any cooling tower fan are eligible for rebates. VFD incentives cannot be applied for if applying for Advanced Rooftop Controlsincentives for the same equipment.HVAC System Type Constant Volume - No Economizer Constant Volume - with Economizer Variable Air Volume (VAV) with EconomizerHVAC System Purpose Space Conditioning (pumps/motors used only tocondition the space)Ref IDEquipment Type Process Cooling (pumps/motors are used strictly to cool aproduct as part of the manufacturing process)Unithp Per Motor (must be 100 hp) Combined Space Cond. and Process Cooling(pumps/motors are used in both)Incentive(Per hp)Motor Quantity Total hpTotal IncentiveVFD-01Return Fan VFDhp 60 VFD-02Supply Fan VFDhp 60 VFD-03Tower Fan VFDhp 60 VFD-04Condenser Water Pump VFDhp 60 VFD-05Hot Water Pump VFDhp 60 VFD-06Chilled Water Pump VFDhp 60 CenterPointEnergy.com/SmartSavings866.240.84762021 Indiana Business Prescriptive Program Electric Measure Selection Form: Heating & Cooling 05.25.21

2021 Business Prescriptive for Indiana Businesses with CenterPoint Energy Electric ServiceProduct & Facility Information (cont.)Programmable ThermostatsRef IDTST-01Equipment SpecificationsProgrammable ThermostatRebateUnit 50EachThermostat Weekly Schedule - REQUIREDSundayMake and ModelQuantityTotal Incentive MondayTuesdayWednesdayThursdayFridaySaturdayAt what time do people arrive (i.e., the building is occupied)?At what time do people leave (i.e., the building is unoccupied)?In the summerWhat are the temperature settings?In the winterOccupiedOUnoccupiedOTotal square footage controlled by thermostat(s)FOFFOFft 2 Must be digital and have the following features: (1) Wake, day, evening and sleep daily settings, (2) Weekday vs. Weekend settings (e.g., 5-2 or 5-1-1), and (3) Override or hold setting Each thermostat must control a minimum of 1500 square feet Installed thermostats must control the primary space heating or cooling source for the facility Primary heating or cooling source of the facility must be electric. The natural gas thermostat rebate cannot be applied for in conjunction with this rebate Rebate not to exceed equipment cost Compared to the occupied temperature, the unoccupied temperature must be 3 degrees warmer in the summer and 3 degrees cooler in the winterWifi-Enabled ThermostatsRef IDTST-02Equipment SpecificationsWifi-Enabled ThermostatRebateUnit 100EachThermostat Weekly Schedule - REQUIREDSundayMake and ModelQuantityTotal Incentive MondayTuesdayWednesdayThursdayFridaySaturdayAt what time do people arrive (i.e., the building is occupied)?At what time do people leave (i.e., the building is unoccupied)?In the summerWhat are the temperature settings?In the winterOccupiedOUnoccupiedOTotal square footage controlled by thermostat(s)FOFFOFft 2 Each thermostat must control a minimum of 1500 square feet Installed thermostats must control the primary space heating or cooling source for the facility Primary heating or cooling source of the facility must be electric. The natural gas thermostat rebate cannot be applied for in conjunction with this rebate Rebate not to exceed equipment cost Must be Wi-Fi capable and connected to the internet for programming and adjusting remotely Compared to the occupied temperature, the unoccupied temperature must be 3 degrees warmer in the summer and 3 degrees cooler in the winterChillers & Chiller ProjectsOnly single-chiller applications are eligible. This measure is for installing a lead chiller that operates the entire cooling season. Back-upchillers are ineligible. Multiple chiller projects should apply for custom rebate.HVAC System Type Constant Volume - No Economizer Constant Volume - with Economizer Variable Air Volume (VAV) with EconomizerHVAC System Purpose Space Conditioning (pumps/motors used only tocondition the space)CenterPointEnergy.com/SmartSavings Process Cooling (pumps/motors are used strictly to cool aproduct as part of the manufacturing process) Combined Space Cond. and Process Cooling(pumps/motors are used in both)866.240.84762021 Indiana Business Prescriptive Program Electric Measure Selection Form: Heating & Cooling 05.25.21

2021 Business Prescriptive for Indiana Businesses with CenterPoint Energy Electric ServiceProduct & Facility Information (cont.)Ref IDCH-01Equipment TypeElectric Chiller - AirCooledCH-03CH-04Equipment SizeAll 150 TonElectric Chiller - WaterCooled - Rotary Screw150 Tons - 299 TonsCH-05 300 TonsCH-06 150 TonCH-07Min. EfficiencyElectric Chiller - WaterCooled - CentrifugalCH-08150 Tons - 299 Tons 300 TonsChiller ModelEfficiency3.36 IPLVIPLV3.08 COPCOP5.58 IPLVIPLV4.95 COPCOP6.17 IPLVIPLV5.41 COPCOP6.89 IPLVIPLV6.06 COPCOP5.86 IPLVIPLV5.58 COPCOP6.51 IPLVIPLV6.17 COPCOP7.18 IPLVIPLV6.76 COPCOPSize (Tons)Incentive(Per Ton)Total Incentive 30 30 30 30 30 30 30 Chiller Tune-UpChiller tune-ups shall include routine inspection for refrigerant leaks & volume, checking compressor operating pressures, all oil levels and pressures, crank case heater operation, andall electrical starters, contractors and relays, examining all motor voltages and amps, filter inspection and replacement when necessary, and cleaning of the coils or tubes. Additionally,water cooled chiller tune-up shall include chilled and condenser temperature adjustments, and compressor unloading switch adjustments. Rebate is available once per 18-month period for each chiller Rebate not to exceed tune-up cost Only lead chillers are eligible for this incentive New construction projects are ineligible for rebateHVAC System Type Constant Volume - No Economizer Constant Volume - with Economizer Variable Air Volume (VAV) with EconomizerHVAC System Purpose Space Conditioning (pumps/motors used only tocondition the space) Process Cooling (pumps/motors are used strictly to cool aproduct as part of the manufacturing process)Ref IDEquipment TypeChiller TypeCH-09Electric Chiller Tune-Up Air-Cooled Water-Cooled Centrifugal Water-Cooled Rotary ScrewModel NumberChiller Size(Tons)Quantity Combined Space Cond. and Process Cooling(pumps/motors are used in both)Total Tons 8Chilled Water Reset Control (Maximum chilled water temperature of 50 F)Ref IDEquipment TypeCH-13Chilled Water Reset ControlChiller Type Air-Cooled ntive(Per Ton)Model NumberChiller Size(Tons)QuantityTotal TonsIncentive(Per Ton) 1.50Total Incentive Total Incentive 866.240.84762021 Indiana Business Prescriptive Program Electric Measure Selection Form: Heating & Cooling 05.25.21

The natural gas thermostat rebate cannot be applied for in conjunction with this rebate Rebate not to exceed equipment cost Compared to the occupied temperature, the unoccupied temperature must be 3 degrees warmer in the summer and