Heating & Air Conditioning

Transcription

Heating & Air ConditioningHVAC SYSTEMS DIAGRAMS E–1HVAC DEFINITIONS AND TERMINOLOGY E–2A/C PADS E–44Air ConditionersPackaged Air Conditioners E–21, 22Split System 13 S.E.E.R. AccuCharge A E–3,4Split System 14 S.E.E.R. AccuCharge A E–5,6Split System 13 S.E.E.R. Sweat Fit E–11,12Split System 14 S.E.E.R. Sweat Fit E–13, 14blowerBlower EB Series E–19, 30, 32, 34CoilR22 Sweat Fit E–16R410A Sweat Fit E–15Coil Cabinet E–19, 30, 31, 35, 36, 38, 40, 41Coil Shelf Kitfor Downflow EBxxB E–18EXTERNAL ROOF JACK EXTENSION E–28FILTERFiberglass Filter E–45, 46FILTER FOR BLEND AIR SYSTEM E–45Foam Filter E–46Metal Filter E–45, 46Tech Fab Blue Filter Washable E–45, 46Trimmable E–45FitRight to Sweat Fit Stub Kits E–8FLEX DUCT E–19,20FLOOR REGISTERSMetal E–44Plastic E–44FurnaceRE9 Electric E–27,28RG1 Gas E–29,30RG7 GAS E–31, 32RO1 OIL E–33, 34VMA Series Gas E–39, 40VMC Series Gas E–37, 38RE9, RG1, AND RO1 FURNACE ACCESSORIES E–35RG7 FURNACE ACCESSORIES E–36Heat Pump13 S.E.E.R. R410A Packaged Heat Pumps E–23, 24Split System 13 S.E.E.R.AccuCharge E–7, 8Split System 14 S.E.E.R. Sweat Fit E–1,9,10Insulation and coil shelf package E–18LIQUID-TIGHT CONDUIT E–43LIQUID-TIGHT CONDUIT KIT E–37Refrigerant Line Sets E–7Roof Jacks E–27Thermostat E–17, 47, 48, 49

Heating and cooling products engineered specificallyfor mobile home installation and optimum performance.

The Mobile Home Revolution Continues!

h e at i n g & a i r co n d i t i o n i n gRevolv Split SystemThermostatEvaporator CoilFurnaceFloor RegisterDuctLinesetCondenserRevolv Split System – This describes an air conditioning or heat pump system that issplit into two sections - an outdoor section and an indoor section. A typical split systemis an air conditioning condensing unit on a pad on the outside of the home with afurnace and or handler inside the home.Revolv Packaged SystemThermostatReturn Air GrillFloor RegisterPackaged UnitDuctFlex DuctRevolv Packaged System – Packaged units provide both heating and cooling fromone unit that is placed outside the home. Packaged units are available in severalcombinations of fuel sources - gas heat/electric cooling; heat pump; electric heat/electric cooling; oil heat/electric cooling.Product Availability, Prices and Specifications Subject to Change without NoticePa g e E– 1

h e at i n g & a i r co n d i t i o n i n gHVAC Terminology and DefinitionsAFUE - An acronym which stands for Annual Fuel Utilization Efficiency wherein the higher the number, the more efficient the unit is rated. The Department ofEnergy's (DOE) minimum efficiency level is 78%.Air Handler - This is the indoor section of a split system, also known as a fan coil, which serves to move air through your duct work via a blower motor.Ambient Temperature - This is the air temperature surrounding the particular piece of equipment.BTU - An acronym which stands for British Thermal Unit (Btu). This is the amount of heat required to raise the temperature of one pound of water by one degreeFahrenheit. These ratings are available on all hvac units. The heating Btu rating and air conditioner Btu rating typically are not the same for a single system.Condensing Unit - This is the outdoor section of a split system air conditioning system which cools refrigerant that circulates in the HVAC system. This unitrequires periodic cleaning to operate efficiently.EER - is an abbreviation for Energy Efficiency Rating. The Air-Conditioning and Refrigeration Institute standardized this rating, which reports central airconditioning efficiency at 80 degrees F indoors and 95 degrees F outdoors. This rating measures steady-state efficiency — that is, the efficiency of the airconditioner once it is up and running.Energy Star – HVAC products with the ENERGY STAR symbol are deemed to be environmentally friendly by meeting strict energy efficiency guidelines set bythe EPA and the DOE.Evaporator Coil – This element transfers heat to provide cooled, dehumidified air into your home or business. This element needs periodic cleaning to work efficiently.Heat Pump – Provides heating and cooling comfort as a split system or as a packaged system. A heat pump can be combined with a gas furnace for betterperformance when temperatures fall below freezing.HSPF - An acronym which stands for Heating Season Performance Factor and indicates the comparative level of a heat pumps' heating efficiency. A higherHSPF number indicates greater efficiency.Latent Heat - is the energy absorbed by or released from a substance during a phase change from a gas to a liquid or a solid or vice versa. If a substance ischanging from a solid to a liquid, for example, the substance needs to absorb energy from the surrounding environment in order to spread out the moleculesinto a larger, more fluid volume. If the substance is changing from something with lower density, like a gas, to a phase with higher density like a liquid, thesubstance gives off energy as the molecules come closer together and lose energy from motion and vibration.Packaged System - Packaged units provide both heating and cooling from one unit that is placed outside the home or business. Packaged units are availablein several combinations of fuel sources - gas heat/electric cooling; heat pump; electric heat/electric cooling; oil heat/electric cooling.Sensible Heat - is the energy required to change the temperature of a substance with no phase change. This is what the thermostat and thermometer registers.SEER Rating - A measurement of the efficiency of cooling products which stands for stands for Seasonal Energy Efficiency Rating. Higher SEER ratingsindicate higher energy efficiency. SEER rating is generally more important than the size of your air conditioning unit.Split System - This describes an air conditioning or heat pump system that is split into two sections - an outdoor section and an indoor section. A typical splitsystem is an air conditioning condensing unit on a concrete pad on the outside of the home with a furnace and air handler inside the home.Thermo Coupler - a heat sensitive device used in a gas furnace which triggers the ignition of burners based.Thermostat - is a control device located inside your home or office used to set, maintain and control temperature levels. A thermostat will automatically turnon an HVAC system to maintain a preset temperature level and should not be used as a switch. Thermostats must be matched to the type of system used andwired accordingly.Ton - A measurement of the capacity of an air conditioning system (not weight). One ton of air conditioning equals 12,000 Btu's per hour. This means that a"one ton" air conditioning system has the capability of removing 12,000 Btu's of heat per hour from your home or business.Product Availability, Prices and Specifications Subject to Change without NoticePa g e E – 2

h e at i n g & a i r co n d i t i o n i n gSplit System AccuCharge 13 SEER Air Conditioners Features and BenefitsWarrantyComposite Base Pan – Absorbs sound and iscorrosion resistant. Composite is also strongerand lighter than steel.Micro-Channel Coils – All aluminum coils in allmodels which provides high corrosion resistance.High Pressure Switch – Protects against abnormallyhigh system pressures. Auto-reset featureprevents nuisance service visits.Louvered Condenser Guard – Durable metalguard protects the coil from yard hazards andextreme weather.Designed Using Galvanized Steel – With apolyester urethane coat finish. The 950 hour saltspray finish resists corrosion 50% better thancomparable units.AccuCharge with FitRight fittings – Correctlycharged for fast easy installations.5 Years Parts / 1 Year Labor ** To receive 10–yearParts Limited Warranty,online registration ofunit must be completed within60 days of installation.Visit www.stylecrestinc.comfor warranty registration Product Availability, Prices and Specifications Subject to Change without NoticePa g e E– 3

h e at i n g & a i r co n d i t i o n i n gRevolv Split System AccuCharge A / C 13 SEERRevolv Split System AccuCharge Air Conditioners 13 SEERTons Nominal2.02.53.03.54.0Outdoor Unit SKURSC1324RSC1330RSC1336RSC1342RSC1348Coil SCI SKU1836M4A1836M4A1854M4A1854M4A1856M4AVapor Line3/4"7/8" *7/8" *7/8"7/8"Liquid Line3/8"3/8"3/8"3/8"3/8"Pad Size24" x 24"24" x 24"24" x 24"32" x 32"32" x 32"* 3/4” up to 24’ lengthRevolv Split System AccuCharge Air ER-QC-AC-13S-4.0TWRevolv Split System AccuCharge 13 SEER Air Conditioner DimensionsUnit SKURSC1324RSC1330RSC1336RSC1342RSC1348(D) Depth22 ¾“22 ¾“22 ¾“30 ¾”30 ¾”(W) Width22 ¾”23 ¾“23 ¾“30 ¾“30 ¾“(H) Height25”29”29”29”29”DHFeatures: Mounted TXV sensor bulb AccuCharge Fit-Right fittings Factory installed TXV valve suitable for A/C or H/P applications Coil has built-in strainer for coil protection UL listed and leak tested to 500 p.s.i. Code approved 2–opening drain pan Dry–type pan does not maintain standing water Kit contains drain hose, fittings, and furnace cover plates for gas/oil furnacesProduct Availability, Prices and Specifications Subject to Change without NoticePa g e E – 4

h e at i n g & a i r co n d i t i o n i n gSplit System AccuCharge 14 SEER Air Conditioners WarrantyFeatures and BenefitsComposite Base Pan – Absorbs sound and iscorrosion resistant. Composite is also strongerand lighter than steel.Micro-Channel Coils – All aluminum coils in allmodels which provides high corrosion resistance.High Pressure Switch – Protects against abnormallyhigh system pressures. Auto-reset featureprevents nuisance service visitsLouvered Condenser Guard – Durable metalguard protects the coil from yard hazards andextreme weather.Designed Using Galvanized Steel – With apolyester urethane coat finish. The 950 hour saltspray finish resists corrosion 50% better thancomparable units.AccuCharge with FitRight fittings – Correctlycharged for fast easy installations.5 Years Parts / 1 Year Labor ** To receive 10–year PartsLimited Warranty, online registrationof unit must be completed within60 days of installation.Visit www.stylecrestinc.comfor warranty registration Product Availability, Prices and Specifications Subject to Change without NoticePa g e E– 5

h e at i n g & a i r co n d i t i o n i n gRevolv Split System AccuCharge A / C 14 SEERRevolv Split System AccuCharge Air Conditioners 14 SEERTons Nominal22.533.54Outdoor Unit SKURSC1424RSC1430RSC1436RSC1442RSC1448Coil SCI AMX48U-BVapor Line3/4"3/4"7/8" *7/8"7/8"Liquid Line3/8"3/8"3/8"3/8"3/8"Pad Size24" x 24"32" x 32"32" x 32"32" x 32"32" x 32"* 3/4” up to 24’ lengthRevolv Split System AccuCharge Air ER-QC-AC-14S-4.0TRevolv Split System AccuCharge Air Conditioner DimensionsUnit SKURSC1424RSC1430RSC1436RSC1442RSC1448(D) Depth22 ¾“30 ¾“30 ¾“30 ¾”30 ¾”(W) Width22 ¾”30 ¾“30 ¾“30 ¾“30 ¾“(H) Height33”29”37”45”45”WDHProduct Availability, Prices and Specifications Subject to Change without NoticePa g e E – 6

h e at i n g & a i r co n d i t i o n i n gSplit System AccuCharge 14 SEER Heat Pumps WarrantyFeatures and BenefitsComposite Base Pan – Absorbs sound and iscorrosion resistant. Composite is also strongerand lighter than steel.Micro-Channel Coils – All aluminum coils in allmodels which provides high corrosion resistance.High Pressure Switch – Protects against abnormallyhigh system pressures. Auto-reset featureprevents nuisance service visits.Louvered Condenser Guard – Durable metalguard protects the coil from yard hazards andextreme weather.Designed Using Galvanized Steel – With apolyester urethane coat finish. The 950 hour saltspray finish resists corrosion 50% better thancomparable units.AccuCharge with FitRight fittings – Correctlycharged for fast easy installations5 Years Parts / 1 Year Labor ** To receive 10–year PartsLimited Warranty, online registrationof unit must be completed within60 days of installation.Visit www.stylecrestinc.comfor warranty registration Product Availability, Prices and Specifications Subject to Change without NoticePa g e E– 7

h e at i n g & a i r co n d i t i o n i n gRevolv Split System AccuCharge H / P 14 SEERRevolv Split System QC Heat Pumps 14 SEERTons Nominal22.533.54Outdoor Unit SKURSH1424RSH1430RSH1436RSH1442RSH1448Coil SCI AMX49U-BVapor Line3/4"3/4"7/8"7/8"7/8"Liquid Line3/8"3/8"3/8"3/8"3/8"Pad Size32" x 32"32" x 32"32" x 32"32" x 32"32" x 32"Revolv Split System Heat P-14S-4.0TRevolv Split System Heat Pump DimensionsUnit SKURSH1424RSH1430RSH1436RSH1442RSH1448(D) Depth30 ¾”30 ¾“30 ¾“30 ¾”30 ¾”(W) Width30 ¾”30 ¾“30 ¾“30 ¾“30 ¾“(H) Height33”42”45”45”45”WDHProduct Availability, Prices and Specifications Subject to Change without NoticePa g e E – 8

h e at i n g & a i r co n d i t i o n i n gManufactured Housing LINESETSLINESET NOMENCLATURE4463Q1532 R22, 4 R410A, 6 Nitrogen or Open EndProduct type–4 complete Line Set. 5 Component of Line SetSuction line diameter–3 3/8”, 2 1/4”, 5 5/8”, 6 3/4”, 7 7/8”Liquid Line Diameter–1 1/8”, 2 1/4”, 3 3/8”, 4 1/2”, etc.Connection type–Q QC both ends. E QC Evap End, S Plain End both indoor and outdoorLineset length 15 15’ L/S, 20 20’ L/S, 25 25’ L/S, 30 30’ L/S, 40 40’L/S, 50 50’ L/S, etc.Wall Insulation thickness–3-3/8” wall, 4-1/2” wall, 5-5/8” wall, 6-3/4” wall, etc.Sell Package quantity–1 individually boxedPre-Charged AccuCharge Refrigerant Line SetsPart Q40314473Q5031DescriptionLINESET-QC R410A 15'-3/8 x 3/4-3LINESET-QC R410A 20'-3/8 x 3/4-3LINESET-QC R410A 25'-3/8 x 3/4-3LINESET-QC R410A 30'-3/8 x 3/4-3LINESET-QC R410A 40'-3/8 x 3/4-3LINESET-QC R410A 50'-3/8 x 3/4-3LINESET-QC R410A 15'-3/8 x 7/8-3LINESET-QC R410A 20'-3/8 x 7/8-3LINESET-QC R410A 25'-3/8 x 7/8-3LINESET-QC R410A 30'-3/8 x 7/8-3LINESET-QC R410A 40'-3/8 x 7/8-3LINESET-QC R410A 50'-3/8 x 7/8-3LengthLiquid LineDiameterSuction 8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/4 3/4 3/4 3/4 3/4 3/4 7/8 7/8 7/8 7/8 7/8 7/8 Wall InsulationThickness3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 LINESET with FitRight fittingsOil packetProduct Availability, Prices and Specifications Subject to Change without NoticePa g e E– 9Fitright fittings1

h e at i n g & a i r co n d i t i o n i n gFitRight to Sweat Fit Stub Kits & Line SetsPart 14573Q2201STUB KIT - OUTDOORDescriptionSTUB KIT-INDOOR - 3/8" x 3/4"STUB KIT-COMBO - 3/8" x 3/4"STUB KIT OUTDOOR - 3/8" x 3/4"STUB KIT-INDOOR - 3/8" x 7/8"STUB KIT-COMBO - 3/8" x 7/8"STUB KIT-OUTDOOR - 3/8" x 7/8"Liquid Line Diameter3/8 3/8 3/8 3/8 3/8 3/8 STUB KIT- INDOORSuction Line Diameter3/4 3/4 3/4 7/8 7/8 7/8 STUB KIT - COMBONOTES:Product Availability, Prices and Specifications Subject to Change without NoticePage E – 1 0

h e at i n g & a i r co n d i t i o n i n g Split System Sweat Fit13 SEER Air ConditionersFeatures and BenefitsWarrantyComposite Base Pan – Absorbs sound and iscorrosion resistant. Composite is also strongerand lighter than steel.Micro-Channel Coils – All aluminum coils in allmodels which provides high corrosion resistance.High Pressure Switch – Protects against abnormallyhigh system pressures. Auto-reset featureprevents nuisance service visits.Louvered Condenser Guard – Durable metalguard protects the coil from yard hazards andextreme weather.Designed Using Galvanized Steel – With apolyester urethane coat finish. The 950 hour saltspray finish resists corrosion 50% better thancomparable units.5 Years Parts / 30 Days Labor ** To receive 10–year PartsLimited Warranty, online registrationof unit must be completed within60 days of installation.Visit www.stylecrestinc.comfor warranty registrationProduct Availability, Prices and Specifications Subject to Change without NoticePa g e E – 1 1

h e at i n g & a i r co n d i t i o n i n gRevolv Split System Sweat Fit A / C 13 SEERRevolv Split System Sweat fit Air Conditioners 13 SEERTons Nominal2.02.53.03.54.0Outdoor Unit SKUR S 4 B D - 024 KR S 4 B D - 030 KR S 4 B D - 036 KR S 4 B D - 042 K BR S 4 B D - 048 K BCoil SCI SKU1836S4A1836S4A1854S4A1854S4A1854S4AVapor Line3/4"3/4"7/8" *7/8"7/8"Liquid Line3/8"3/8"3/8"3/8"3/8"Pad Size24" x 24"24" x 24"24" x 24"32" x 32"32" x 32"* 3/4” up to 24’ lengthRevolv Split System Sweat fit Air ConditionersR S 4 B D - 024 KR S 4 B D - 030 KR S 4 B D - 036 KR S 4 B D - 042 K BR S 4 B D - 048 K BCONDENSER - SF - AC -13S-2.0TCONDENSER - SF - AC -13S-2.5TCONDENSER - SF - AC -13S-3.0TCONDENSER - SF - AC -13-3.5TCONDENSER - SF - AC -13S-4.0TWRevolv Split System Sweat fit13 SEER Air Conditioner DimensionsUnit SKUR S 4 B D - 024 KR S 4 B D - 030 KR S 4 B D - 036 KR S 4 B D - 042 K BR S 4 B D - 048 K B(D) Depth22 ¾“22 ¾“22 ¾“30 ¾”30 ¾”(W) Width22 ¾”23 ¾“23 ¾“30 ¾“30 ¾“(H) Height25”29”29”29”29”DHFeatures and BenefitsFactory installed – TXV valve suitable forA/C or H/P applications.Coil – Built-in strainer for coil protection.UL listed – Leak tested to 500 p.s.i. Codeapproved 2–opening drain pan.Dry-type pan – Does not maintain standing water.Kit – Contains drain hose, fittings, and furnace coverplates for gas/oil furnaces.Furnace Compatibility:All standard mobile home furnaces *Confirm furnace coil cavity dimensions. Refer to coildimension table on page E-15*Product Availability, Prices and Specifications Subject to Change without NoticePage E – 1 2

h e at i n g & a i r co n d i t i o n i n g Split System Sweat Fit14 SEER Air ConditionersWarrantyFeatures and BenefitsComposite Base Pan – Absorbs sound and iscorrosion resistant. Composite is also strongerand lighter than steel.Micro-Channel Coils – All aluminum coils in allmodels which provides high corrosion resistance.High Pressure Switch – Protects against abnormallyhigh system pressures. Auto-reset featureprevents nuisance service visits.Louvered Condenser Guard – Durable metalguard protects the coil from yard hazards andextreme weather.Designed Using Galvanized Steel – With apolyester urethane coat finish. The 950 hour saltspray finish resists corrosion 50% better thancomparable units.5 Years Parts / 30 Days Labor ** To receive 10–year PartsLimited Warranty, online registrationof unit must be completed within60 days of installation.Visit www.stylecrestinc.comfor warranty registrationProduct Availability, Prices and Specifications Subject to Change without NoticePa g e E – 1 3

h e at i n g & a i r co n d i t i o n i n gRevolv Split System Sweat Fit A / C 14 SEERRevolv Split System Sweat Fit Air Conditioners 14 SEERTons Nominal22.533.54Outdoor Unit SKUR S 4 B E - 024 KR S 4 B E - 030 KR S 4 B E - 036 KR S 6 B F - 042 K BR S 6 B F - 048 K BCoil SCI SKUC 8 D A M X 24 U - BC 8 D A M X 30 U - BC 8 D A M X 36 U - BC 8 D A M X 42 U - BC 8 D A M X 48 U - BVapor Line3/4"3/4"7/8" *7/8"7/8"Liquid Line3/8"3/8"3/8"3/8"3/8"Pad Size24" x 24"32" x 32"32" x 32"32" x 32"32" x 32"* 3/4” up to 24’ lengthRevolv Split System Sweat Fit Air ConditionersR S 4 B D - 024 K AR S 4 B d - 030 K AR S 4 B D - 036 K AR S 4 B D - 042 KR S 4 B D - 048 KCONDENSER - SF - AC - 14S-2.0TCONDENSER - SF - AC - 14S-2.5TCONDENSER - SF - AC - 14S-3.0TCONDENSER - SF - AC - 14S-3.5TCONDENSER - SF - AC - 14S-4.0TRevolv Split System Sweat Fit Air Conditioner DimensionsUnit SKUR S 4 B E - 024 KR S 4 B E - 030 KR S 4 B E - 036 KR S 6 B F - 042 K BR S 6 B F - 048 K B(D) Depth22 ¾“30 ¾“30 ¾“30 ¾”30 ¾”(W) Width22 ¾”23 ¾“23 ¾“30 ¾“30 ¾“(H) Height33”29”37”45”45”WDHProduct Availability, Prices and Specif

Heating & Air Conditioning A/C PADS E–44 Air ConDitionerS Packaged Air Conditioners E–21, 22 Split System 13 S.E.E.R. AccuCharge A E–3,4 Split System 14 S.E.E.R. AccuCharge A E–5,6 Split System 13 S.E.E.R. Sweat Fit E–11,12 Split System 14 S.E.E.R. Sweat Fit E–13, 14 blower