Dell EMC PowerStore Spec Sheet

Transcription

Spec SheetDELL EMC POWERSTORESTORAGE FAMILYThe ground-breaking Dell EMC PowerStore achieves new levels of operational simplicity and agility, utilizing a containerbased architecture, advanced storage technologies, and intelligent automation to unlock the power of your data. Basedon a scale-out architecture and hardware-accelerated advanced data reduction, PowerStore is designed to deliverenhanced resource utilization and performance that keeps pace with application and system growth. Utilizing the provencapabilities of VMware ESXi, PowerStore X models with AppsON provide the unique ability to host data-intensive andstorage applications directly on the PowerStore system with a storage-based virtualization environment, with the flexibilityof seamless movement of applications between the storage system and external VMware servers. PowerStore T modelsprovide organizations with all the benefits of an enterprise unified storage platform for block, file and vVol data, whileenabling flexible growth with the intelligent scale-up AND scale-out capability of appliance clusters.ArchitectureBased on a versatile scale-up and out platform utilizing Intel Xeon Scalable processors and today’s most advancedstorage technologies, including NVMe Flash and dual-ported Intel OptaneTM SSDs and always-on inline data reduction,PowerStore uses powerful analytics, automation and active resource balancing to optimize performance and eliminatemanagement overhead. Each appliance utilizes dual active-active storage nodes and a container-based softwarearchitecture to provide maximum adaptability. Additional storage capacity is added to each appliance via up to three driveexpansion enclosures.Physical Specifications10003000500070009000Max Drives9696969696NVRAM per Appliance22444PER APPLIANCEBase EnclosureExpansion EnclosureA 2U, 2 node enclosure with twenty-five 2.5” NVMe drive slotsA 2U enclosure attached to a PowerStore base enclosure with twenty-five 2.5” SAS drives slots (3 max per appliance)Power SuppliesPowerStore appliances are powered by 2 redundant power supplies (PS) per enclosure.RAID 5 (4 1/8 1)RAID OptionsCPUs per ApplianceSystem Cache / Memory4 x Intel CPUs,32 cores, 1.8GHz4 x Intel CPUs,48 cores, 2.1GHz4 x Intel CPUs,64 cores, 2.1GHz4 x Intel CPUs,80 cores, 2.4GHz4 x Intel CPUs,112 cores, 2.1GHz384 GB768 GB1,152 GB1,536 GB2,560 GBMax Mezzanine cardsper Appliance*22222Max IO Modules perAppliance**44444Embedded SAS IO Portsper ApplianceDELL EMC POWERSTORE FAMILY 2020 Dell Inc. or its subsidiaries.4 x 4 lane 12Gb/s SAS ports for back end connection

10003000500070009000Max front end Ports perAppliance (all types)2424242424Max 16/32Gb FC Portsper Appliance1616161616Max 10 Gbase-T/iSCSIPorts per Appliance2424242424Max 10/25 GbE/iSCSIPorts per Appliance2424242424PER APPLIANCESpec SheetMax Raw Capacity***898.56 TB898.56 TB898.56 TB898.56 TB898.56 TB817.36 TiB817.36 TiB817.36 TiB817.36 TiB817.36 TiB* One Mezzanine card per node, mirrored.** Two IO Modules per node, mirrored.*** Value shown is vendor raw base capacity. TB is base-10 decimal (1000x1000x1000x1000). TiB is base-2 binary (1024x1024x1024x1024). For true appliance useablecapacity data refer to Power Sizer.Maximum raw capacity may vary based on drive sizes available at time of purchase.Maximum logical capacity supported per appliance is 8 exabytes (EB)Appliance System Limits10003000500070009000Max Initiators2,0002,0002,0002,0002,000Max BlockVolumes/Clones2,0002,0002,0002,0002,000Max Volumes perVolume Group7575757575Max Volume Groups125125125125125Max Volume Size256 TB256 TB256 TB256 TB256 TBMax attached snapshots(Block)10,00010,00010,00010,00010,000Max User File Systems *500500500500500Max NAS Servers *5050505050256 TB256 TB256 TB256 TB256 0760760PER APPLIANCEMax File System Size *Max vVol StorageContainersMax vVolsMax vVol VMsOS SupportSee the Dell EMC Simple Support Matrix on delltechnologies.com* Available for PowerStore T models onlyCluster System Limits **PER CLUSTER **Max. AppliancesMax. DrivesMax. Front End PortsMax. Raw Capacity (TB)** PowerStore T models only.2DELL EMC POWERSTORE FAMILY 2020 Dell Inc. or its subsidiaries.4384963,594Max InitiatorsMax Initiators in an Initiator GroupMax. iSCSI sessionsMax. Raw Capacity (TiB)2,0001,0242,0483,267

Spec SheetConnectivityConnectivity options via Mezzanine cards and IO modules for file, for NFS/SMB connectivity, and block storage for FCand iSCSI host connectivity (see above table for number of modules supported per node).Connectivity OptionsTypeDescriptionMezzanine card / IO ModuleFour-Port 10Gbase-T Module (File &Block)Mezzanine card / IO ModuleIO ModuleIO ModuleIO ModuleDetailsFour port 10Gbase-T Ethernet IP/iSCSI module with copperconnection to Ethernet switchFour port IP/iSCSI module with choice of 25GbE or 10GbE.Four-Port 25 Gb/s Optical Module (FileUses SFP optical connection or active/passive twinax copper& Block)connection to Ethernet switchFour port FC module with choice of 16Gb/s or 32Gb/sFour-Port 32 Gb/s Fibre Channelconnectivity. Uses multimode optical SFP and OM2/OM3/OM4Module (Block only)cabling to connect directly to host HBA or FC switchFour-Port 10Gbase-T Module (BlockFour port 10Gbase-T Ethernet IP/iSCSI module with copperOnly) *connection to Ethernet switchFour port IP/iSCSI module with choice of 25GbE or 10GbE.Four-Port 25 Gb/s Optical ModuleUses SFP optical connection or active/passive twinax copper(Block Only) *connection to Ethernet switch* IO module type only available for PowerStore T modelsBack-end (Drive) ConnectivityEach node connects to one side of each of two redundant pairs of four-lane x 12 Gb/s Serial Attached SCSI (SAS) ports,providing continuous drive access to hosts in the event of a node or port fault.Disk Expansion Enclosure25 X 2.5” Drive EnclosureDrive Types SupportedSAS SSDController Interface12 Gb SASSupported MediaDrive TypeInterfaceRaw base-10Capacity *Raw base-2Capacity **Base EnclosureNVMe SSDPCIe1.92 TB1.7466 TiB NVMe SSDPCIe3.84 TB3.4931 TiB NVMe SSDPCIe7.68 TB6.9863 TiB NVMe SSDPCIe15.36 TB13.9707 TiB NVMe Optane SCM SSDPCIe375 GB349.3 GB NVMe Optane SCM SSDPCIe750 GB698.6 GB SAS SSD12 Gb SAS1.92 TB1.7466 TiB SAS SSD12 Gb SAS3.84 TB3.4931 TiB SAS SSD12 Gb SAS7.68 TB6.9863 TiB * Base-10 vendor raw TB (bytes X (1000 x 1000 x 1000 x 1000))** Base-2 vendor raw TiB (bytes X (1024 x 1024 x 1024 x 1024))All drives are 512 bytes/sector.All drives are FIPS 140-2 certified TCG SED3DELL EMC POWERSTORE FAMILY 2020 Dell Inc. or its subsidiaries.ExpansionEnclosure

Spec SheetOE Protocols and Software FacilitiesSupport is provided for a wide variety of protocols and advanced features available via various software suites, plug-ins,drivers and packs.Protocols and Facilities SupportedAccess-based Enumeration (ABE) for SMBprotocolAddress Resolution Protocol (ARP)Block Protocols: iSCSI, Fibre Channel (FCPSCSI-3)DFS Distributed File System (Microsoft) asStandalone Root ServerDirect Host Attach for Fibre ChannelDynamic Access Control (DAC) with claimssupportInternet Control Message Protocol (ICMP)Kerberos AuthenticationLock Manager (NLM) v1, v2, v3, and v4Management & Data Ports IPv4 or IPv6NAS Servers Multi-protocol for UNIX and SMBclients (Microsoft, Apple, Samba)Network Data Management Protocol (NDMP)v1-v4, 3-wayRestriction of Hazardous Substances (RoHS)complianceRSVD v1 for Microsoft Hyper-V (SMB3)Simple Home Directory access for SMBprotocolNetwork Information Service (NIS) ClientSimple Mail Transfer Protocol (SMTP)Network Status Monitor (NSM)Virtual LAN (IEEE 802.1q)Network Time Protocol (NTP) ClientVMware Virtual Volumes (vVols) 2.0NFS v3/v4 Secure SupportNT LAN Manager (NTLM)REST API: Open API that uses HTTP requeststo provide managementvStorage APIs for Storage Awareness (VASA)VMware Aware Integration (VAI)Security & ComplianceCommon Criteria (in process)Data at Rest Encryption (D@RE) utilizing FIPS 140-2 Level 2 validated SED drives for primary storage (NVMe SSD, NVMe SCM & SAS SSD).The NVRAM caching device is encrypted but not FIPS 140-2 validated at this time.IPv6 certification (in planning)Native SHA2 certificateTLS 1.2 support by default, TLS 1.1 and older are disabledService and SupportWorld-Class Dell Technologies ServicesDeployment ServicesSupport ServicesServices & Support Technologies4DELL EMC POWERSTORE FAMILY 2020 Dell Inc. or its subsidiaries. Dell EMC ProDeploy Enterprise SuiteDell EMC Migration ServicesDell EMC Residency ServicesDell EMC ProSupport Enterprise SuiteAnytime UpgradesDell EMC Optimize for StorageMyService360SupportAssist Enterprise

Spec SheetSoftwareAll Inclusive Base SoftwareInterface ProtocolsManagement Software: PowerStore Manager CloudIQ: Cloud-based storage analytics Thin Provisioning Dynamic RAID Data Reduction: Zero Detect/Deduplication/Compression Proactive Assist: Configure remote support, online chat, open a service request, etc. Quality of Service (Block and vVols)Protocols: PowerStore T Models Block vVols FileProtocols: PowerStore X Models Block vVolsLocal Protection: SED Based Encryption with self-managed key management Local Point-In-Time Copies (Snapshots and Thin Clones) AppSync Basic Dell EMC Common Event Enabler; AntiVirus AgentRemote Protection: Native Asynchronous BlockMigration: Native Block migration from Dell EMC Unity, VNX, SC Series, PS SeriesBlock: FC, iSCSI and VMware Virtual Volumes (vVols) 2.0File: NFSv3, NFSv4, NFSv4.1; CIFS (SMB 1), SMB 2, SMB 3.0, SMB 3.02, and SMB 3.1.1; FTPand SFTPOptional Software and Solutions AppSync AdvancedData Protection Suite: Backup, Archive and Collaboration SoftwareDell EMC RP4VMPowerPath Migration EnablerPowerPath MultipathingVPLEXNote: For more details on software licensing, please contact your sales representativeVirtualization and Container SolutionsPowerStore offers support for a wide variety of protocol and advanced features available via various software suites andpacks including but not limited to:5 Dell EMC Virtual Storage Integrator (VSI) for VMware vSphere : For provisioning, management, and cloning VMware Site Recovery Manager (SRM) Integration: Managing failover and failback making disaster recoveryrapid and reliable Virtualization API Integration: VMware: VAAI and VASA. vRO Plugin for PowerStore Container Storage Interface (CSI) Plugin for PowerStore Ansible Module for PowerStoreDELL EMC POWERSTORE FAMILY 2020 Dell Inc. or its subsidiaries.

Electrical SpecificationsSpec SheetAll power figures shown represent a worst-case product configuration with max normal values operating in an ambienttemperature environment of 40 C.The enclosure power numbers provided may increase when operating in a higher ambient temperature environment.PowerStore Base System Enclosures1000 Base3000 Base21x2.5” drives,2xNVRAMmodulesfour IO modules21x2.5” drives,2xNVRAMmodulesfour IO modules5000 Base7000 Base9000 Base21x2.5” drives,4xNVRAMmodulesfour IO modules21x2.5” drives,4xNVRAMmodulesfour IO modules21x2.5” drives,4xNVRAMmodulesfour IO modulesPOWERAC Line Voltage240 VAC 10%, single phase, 47 to 63 HzAC Line Current(operatingmaximum)8.1 A max at 200VAC8.1 A max at 200VAC9.0 A max at 200VAC9.3 A max at 200VAC10.4 A max at200VACPowerConsumption(operatingmaximum)1629.6 VA (1597 W)max at 200 VAC1629.6 VA (1597 W)max at 200 VAC1792.9. VA (1757.96W) max at 200 VAC1868.4 VA (1831 W)max at 200 VAC2088.8 VA (2047 W)max at 200 VAC5.74 x 10 J/hr, (5,449Btu/hr) max 200VAC5.74 x 10 J/hr, (5,995Btu/hr) max 200VACPower FactorHeat Dissipation(operatingmaximum)0.95 minimum at full load, @ 200 VAC666.32 x 106 J/hr, (5,995Btu/hr) max 200VAC6.59 x 106 J/hr, (6,248Btu/hr) max 200VACIn-rush Current45 Apk “cold” per line cord, at any line voltageStartup SurgeCurrent120 Apk “hot” per line cord, at any line voltageAC Protection20 A fuse on each power supply, single lineAC Inlet TypeIEC320-C14 orIEC320-C20IEC320-C14 orIEC320-C20Ride-throughTimePowerStore 5000TIEC320-C14 orIEC320-C20PowerStore 5000XIEC320-C20IEC320-C207.37 x 106 J/hr, (6,985Btu/hr) max 200VACIEC320-C2010 ms minCurrent Sharing 5 percent of full load, between power suppliesNote: Power consumption values for enclosures are based on fully populated enclosures (power supplies, drives and I/O modules).WEIGHT AND DIMENSIONSWeight kgs/lbsVertical size6empty 35.80/79full 41.7/922 NEMA unitsempty 35.80/79full 41.7/922 NEMA unitsempty 35.80/79full 41.7/922 NEMA unitsempty 35.80/79full 41.7/922 NEMA unitsempty 35.80/79full 41.7/922 NEMA unitsHeight 3.43Width .6144.72/17.61Depth .3279.55/31.32DELL EMC POWERSTORE FAMILY 2020 Dell Inc. or its subsidiaries.

Drive Expansion EnclosureSpec SheetPOWERAC Line VoltageAC Line Current (operating maximum)25 X 2.5” Drive Expansion Enclosure100 to 240 VAC 10%, single phase, 47 to 63 Hz4.50 A max at 100 VAC,2.40 A max at 200 VACPower Consumption (operating maximum)453.0 VA/ 432.0 W max at 100 VAC485.0 VA/ 427.0 W max at 200VACPower Factor0.95 minimum at full load, @ 100V/200VHeat Dissipation (operating maximum)1.56 x 106 J/hr, (1,474 Btu/hr) max at 100 VAC1.54 x 106 J/hr, (1,457 Btu/hr) max at 200 VACIn-rush Current30 Apk “cold” per line cord, at any line voltageStartup Surge Current40 Apk “cold” per line cord, at any line voltageAC Protection15 A fuse on each power supply, single lineAC Inlet TypeIEC320-C14 appliance coupler, per power zoneRide-through Time12 ms minimumCurrent Sharing 5 percent of full load, between power suppliesWEIGHT AND DIMENSIONSWeight kg/lbsEmpty: 10.0/22.1Full: 20.23/44.61Vertical size2 NEMA unitsHeight cm/inches8.64/3.40Width cm/inches44.45/17.5Depth cm/inches33.02/13Note: Power consumption values for Base Enclosure and Expansion Enclosures are based on fully populated enclosures (power supplies, drives and I/O modules).Cabinets7Standard 40U CabinetAC Line Voltage200 to 240 VAC 10%, single-phase, 47 to 63 HzPower ConfigurationOne, two, three, four, five, six power domains, each redundantPower Inlet CountTwo, four, six, eight, ten, or twelve (two per domain)Plug TypesNEMA L6-30P or IEC309-332 P6 or IP57 (Australia)Input Power Capacity1 Domain: 4,800 VA @ 200 VAC, 5,760 VA @ 240 VAC2 Domain: 9,600 VA @ 200 VAC, 11,520 VA @ 240 VAC3 Domain: 14,400 VA @ 200 VAC, 17,280 VA @ 240 VAC4 Domain: 19,200 VA @ 200 VAC, 23,040 VA @ 240 VAC5 Domain: 24,000 VA @ 200 VAC, 28,800 VA @ 240 VAC6 Domain: 28,800 VA @ 200 VAC, 34,560 VA @ 240 VACAC Protection30 A site circuit breakers on each power branch40U Cabinet DimensionsHeight - 75 in (190.8 cm); Width - 24.0 in (61.1 cm); Depth - 39.0 in (99.2 cm); Weight Empty – 380 lb(173 kg)DELL EMC POWERSTORE FAMILY 2020 Dell Inc. or its subsidiaries.

Operating EnvironmentSpec SheetDescriptionSpecificationRecommended RangeOperationThe limits under whichequipment will operate themost reliably while stillachieving reasonably energyefficient data center operation.18 C to 27 C (64.4 F to 80.6 F) and 15 C (59 F) dew pointContinuous AllowableRange OperationData center economizationtechniques (e.g. free cooling)may be employed to improveoverall data center efficiency.These techniques may causeequipment inlet conditions tofall outside the recommendedrange but still within thecontinuously allowable range.Equipment may be operatedwithout any hourly limitationsin this range.5 C to 35 C (50 F to 95 F) at 20% to 80% relative humidity with 21 C (69.8 F)maximum dew point (maximum wet bulb temperature). De-rate maximumallowable dry bulb temperature at 1 C per 300m above 950m (1 F per 547 ftabove 3117 ft).Improbable Operation(Excursion Limited)During certain times of the dayor year, equipment inletconditions may fall outside thecontinuously allowable rangebut still within the expandedimprobable range. Equipmentoperation is limited to 10% ofannual operating hours in thisrange.35 C to 40 C (with no direct sunlight on the equipment) at -12 C minimum dewpoint and 8% to 85% relative humidity with 24 C maximum dew point (wet bulbtemperature). Outside the continuously allowable range (10 C to 35 C), thesystem can operate down to 5 C or up to 40 C for a maximum of 10% of itsannual operating hours. For temperatures between 35 C and 40 C (95 F to104 F), de-rate maximum allowable dry bulb temperature by 1 C per 175mabove 950m (1 F per 319 ft above 3117 ft).Temperature GradientAltitude20 C / hour (36 F / hour)Max Operating3050m (10,000ft)Statement of ComplianceDell EMC Information Technology Equipment is compliant with all currently applicable regulatory requirements forElectromagnetic Compatibility, Product Safety, and Environmental Regulations where placed on market.Detailed regulatory information and verification of compliance is available at the Dell Regulatory Compliance website.http://dell.com/regulatory compliance.Learn more about DellEMC PowerStoresolutions8DELL EMC POWERSTORE FAMILYCopyright 2020 Dell Inc. or its subsidiaries. All Rights Reserved.Dell Technologies, Dell, EMC, Dell EMC and other trademarks are 2020 Dell Inc. or its subsidiaries.trademarks of Dell Inc. or its subsidiaries. Other trademarks may betrademarks of their respective owners.H18143.2Contact a Dell EMC Expert

Dell EMC Virtual Storage Integrator (VSI) for VMware vSphere : For provisioning, management, and cloning VMware Site Recovery Manager (SRM) Integration: Managing failover and failback making disaster recovery rapid and reliable Virtualization API Integration: VMware: VAAI and VASA. vRO Plugin for PowerStore