3 RGE ARRESTERS3UR ÜÌ À«i, ÞV i -Ì Ì Ê ÃÃ ÃÌÀ LÕÌ Ê ÃÃ Ê ÊÊ/À VÌ L iÊ- i Ì ÀwÊi Ê } Ì }

ElectronicsSurge ArrestersDistribution Class - Open Cage Polymeric ‘OCP’OCP is the latest gapless, zinc oxide arresterfamily from Bowthorpe.The OCP development was based on 25 yearsof internal experience in arrester design andmanufacture within the TYCO Energy division.BOWTHORPE OCP BENEFITS:Tested in accordance with IEC60099-4 atindependent accredited laboratories.Superior protection margins.Direct molded housing to prevent moistureingress.Low residual voltages.High-energy handling.Superior TOV performance.Safe non-shattering short circuit behavior tohigher current levels.Maintenance free.Hydrophobic silicone housing, tracking anderosion resistant.Surge ArrestersExcellent cantilever and tensile performance.Excellent vibration and impact withstandcapability.Quality design and manufacturing, ISO 9001and 14001 compliant.Refer Brochure: Bowthorpe MV arresters OCP EPP-1098 for details15-2www.dulmison.com.au

ElectronicsSurge ArrestersDistribution Class - Polymeric ‘OCP1’Application:Protection of MV networks and equipment from lightning and switching surge related overvoltages in areas with relatively high iso-keraunic levels. Suitable for both outdoor and indoor useto protect transformers and cable end terminations.Generic technical data:OCP1 seriesRated discharge current (8/20µs):Line discharge class 1 according toOperating duty impulse withstand current (4/10µs):Long duration current impulse (2000µs):High current short circuit: (pre-failing method)(Safe non-shattering failure mode)Energy2 Long duration impulses:Cantilever strength3-24kV Uc10kAIEC 60099-4100kA350A25kA4.1kJ/kVUc350 NmTOV of OCP1 with 100kA single shot high current prior energy1.601.551.50TOV Curve1.451.351.30110100100010000Time (s)Temperature of samples(pre-heated): 60 degrees C according to IEC 60099-4, Ed 2.0 2004.TOV Curve applies to an arrester which has a pre-stress applied prior to TOV verification.This pre-stress is equivalent to one high current impulse of 100kA, 4/10 as per the switchingsurge operating duty test.Uw TOV withstand voltage; Uc continuous operating voltage.www.dulmison.com.au15-3Surge ArrestersUw/Uc1.40

ElectronicsSurge ArrestersDistribution Class - Polymeric ‘OCP1’UcUrOCP1- kV (rms) kV 27.51011.212.51518.722.52526.227.530Residual Voltage in kV when tested to the following impulse 839.1048.8758.6465.1668.4271.6878.19OCP-xxS; Standard housing parametersImpulse PF WetSWWSFO DistOCP1kVkVmmSurge 6176176176176176214254254293293293OCP-xxL; Extended housing parametersImpulse PF WetSWWSFO .9076.5680.3984.2291.87CreepagemmHeight 3183183183183220260260299299299CreepagemmHeight 119mm

ElectronicsSurge ArrestersOCP Series naming and order query descriptionExample: OCP ‘Open Cage Polymeric’OCP0 - 12S - ABCSystem Voltage Um ph/ph (a) ph/ground (b)122436Line discharge class:0 5kA, 65kA high current1 10kA, 100kA high current, class 12 10kA, 100kA high current, class 2185315445ba165295425aUcHousing creepage:S standard creepageL extended creepageAccessory selection:M Mounting bracketE Earth connectionL Line connectionLine lead accessories55mmM55mmFNQVArrester Type Continuous Operating Voltage Uc in kV03081522-04 05 0609 10 1218 20 2124OCP- 12-Surge ArrestersOCPMounting accessoriesBCNTNV55mmAFM55mmD55mmGround lead accessoriesAdditional accessory options available on request.Please contact: surgearresters@tycoelectronics.com with your specific requirements.www.dulmison.com.au15-1

ElectronicsSurge ArrestersStation Class - Porcelain Conventional design High voltage porcelain Glazed externally and internally Varistors in single column, spring loaded with air cavity Up to 400kV Pressure relief performance 40kA Grey or BrownCat ykA10101020LinePressureDischarge Relief ClassClasskA2234Surge ArrestersRefer brochure: Transmission Surge Arresters BOW-EPP-0001 for details.15-6www.dulmison.com.au40254040

ElectronicsSurge ArrestersStation Class - Polymeric Patented design Void free construction High cantilever strength which maintains electrical continuity Non shattering 25 kA Short Circuit performance Up to 3 units high Extended Creepage availableCat HSR6 - 4848 - 8496 - 132101010222Surge ArrestersRefer brochure: Transmission Surge Arresters BOW-EPP-0001 for details.www.dulmison.com.au15-7

ElectronicsSurge ArrestersStation Class - PolymericSurge Arresters Patented Series Parallel design provides the best solution forhigher voltage systems Line Discharge Class 2,3,4 & 5 high energy levels 3KV to 800KV rated systems Series Parallel design is the number one seismic arresterwhich meets the requirements of BPA in USA NGC Approval at 132, 275 & 400kV Easy Installation in Remote LocationsCat No.VoltageRatingkVDutykALineDischargeClass2P3P, 4P, 5P30 - 16896 - 5251010/2033, 4 & 5Refer brochure: Transmission Surge Arresters BOW-EPP-0001 for details.12-8www.dulmison.com.au

ElectronicsSurge ArrestersSurge Counters SC12 SC13 (With Leakage Current Display) & AC (With Auxiliary Contacts)Arrester base must be insulatedInsulated bases are available for all Tyco arrestersSame robust design for over twenty yearsLeading supplier to OEMsSurge Arresters www.dulmison.com.au15-9

ElectronicsSurge ArrestersSheath Voltage LimiterSurge Arresters Protection of single bond and cross bonded HV cables. Protects against short circuit induced over voltage15-10www.dulmison.com.auCat , 3, 6 & 91, 3, 6 & 91, 3, 6 & 9123

ElectronicsSurge ArrestersDC TractionMain FeaturesThe arrester has a 10kA nominal discharge current and100kA duty cycle performance to EN 50123-5-2003.The patented void free construction of this arresterdesign results in a unit with strength which isimpervious to the ingress of moisture.The arrester has the following features: No internal airspace so no moisture ingress Vandal proof High cantilever and torsional strength Non-explosive failure mode Low weight and small size Resistant to transport damage and careless handling Easy to installElectrical PerformanceClassification (8/20 µs nominal discharge current)Voltage RatingHigh Current Operation DutyHigh Current Single Impulse Energy––––10,000 Amps1kV to 4.9kV DC100kA 4/10µs2.3kJ/kV at UrSurge ArrestersOperating Duty Cycle – 2 shots hi-current followed by the voltage profile Ur(300s) then Uc- (1800s) as per EN50123-5 2003 clause 4.7.5.4 and figure 4.1to prove thermal stability.Refer brochure: DC Traction BOW-EPP-0005 for detailswww.dulmison.com.au15-11

ElectronicsSurge ArrestersAirfield LightingTechnical DataArrester Type 2DCAFL4 is housed in a die-cast aluminium box finished in grey paint and complieswith IP65. The box is fitted with four aluminium cable glands to BS6121 to accommodate supplycables with diameter 11.00mm to 13.5mm. The box has a stainless steel M12 earth terminal studwith two lock nuts and clamp washers.The box lid is removed for connections and the internal screw-type terminals will accommodatewires up to 6mm diameter. (Hexagon Key provided.)Box size: 260mm x 160mm x 90mmSurge ArrestersThe Arrester Type 2DCAFL4 has the following electrical performance -Nominal a.c. ratingMaximum continuous operating d.c. voltageArrester ClassifcationHigh CurrentEnergy handling capability equivalentWithstand based on 2000ms rectangular waveOperating temperatureStandard15-124.0kv rms5.2kv5000A65kA1 (IEC 60099-4 Clause 7.4.2 table 4 & 7.5.5.5)250A-40 C to 40 CIEC 60099-4 2001www.dulmison.com.au

ElectronicsSurge ArrestersTransmission Line ArresterKey Features HV arrester suspended from a transmission line givingenhanced transmission line performance. Increasing system line voltage on standard insulatedtransmission lines.Benefits of TLA ApplicationsCat son.com.auSurge Arresters Minimising circuit breaker operation with possiblesystem outage resulting from back flashover on thetransmission line. Switching overvoltages are absorbed over the length ofthe line reducing the severity of surge at the substation. Transmission systems can be operated even wheresub-soil gives poor tower footing resistance. Eliminating interrupted power supply for sensitiveindustrial processes. Installing Transmission Line Arresters on a standard 3phase voltage system along the line, at calculatedintervals, allows for optimum performance of the TLA,to give an increased system line voltage. Therefore eliminating the need to increase the standardinsulation level required on conventional systemupgrade.15-13

Surge Arresters Refer Brochure: Bowthorpe MV arresters OCP EPP-1098 for details. Application: Protection of MV networks and equipment from lightning and switching surge related over-voltages in areas with relatively high iso-keraunic levels. Suitable for both outdoor and indoor use to protect transformers and cable end terminations. Generic technical data: OCP1 series Rated discharge