Document Ref: SL-051 V5 International Gas Detectors ACCESSORIES - IGD

Transcription

AccessoriesProduct DataDocument Ref: SL-051 V5International Gas DetectorsACCESSORIESIGD provide a range of accessories to enhance theperformance of your Gas Detection System by cateringto an applications specific needs. Whether this isdetecting lighter than air gases, providing additional IPProtection for sensors or adding safety features to assistthe quick evacuation of personal from gas hazards.GAS COLLECTOR CONES & HOODSAvailable to fit all IGD Gas Detectors. They aretypically used when detecting lighter than air gases toenhance detection capability at specific points whereleaks are likely to occurCALIBRATION KITS & GAS BOTTLESIGD provide gas calibration kits and replacement gasbottles to support our range of gas detectors.SPLASH GUARDSSplash Guards provide additional IP Protection fordetectors where splashes, dust or draughts are aconcern.ATEX JUNCTION BOXESATEX Junction Boxes allow you to mount IGD 102 orMKIII Series ATEX Sensors in Zone 1 and 2explosive areas and Zone 21 and 22 dustenvironments or provide extra break out terminals.BEACON SOUNDERSProvide visual and audible signals to assist in alertingpersonnel and aiding evacuation in the event of aGas Alarm.REMOTE GASSING PORTDesigned to allow easier bump testing or calibrationof detectors located in hard to access locationsREMOTE RESET BUTTONSAllow users to remotely reset or mute a gas alarmactivation without going back to the control panel.DUCT ADAPTERSAre designed to allow monitoring of gas streamsinside duct work or tank head spaces.PIPE IN PIPE ADAPTORDesigned to enable detectors to monitor theinterstitial gap in double containment pipe systems.internationalgasdetectors.com 44 (0)161 483 1415@FS646773EMS696504Triton HouseCrosby /international-gas-detectors-ltdSK2 6SH

AccessoriesProduct DataDocument Ref: SL-051 V5GAS COLLECTORCollector Hoods are used where gas detection is required over a larger areaH O O D S Gasthan can be covered using a collector cone or where multiple collector coneswould be impractical. The hoods are supplied in multiples of 0.5M up to 2.5Mlong. They are usually suspended using catenary wire above the equipment to bemonitored for lighter than air gas escapes.Hoods can be used with samplers or any IGD diffusion style detector such asTOC-750 or TOC-750X.Note in the case of ATEX detectors, the detector must be separately supported.TOC-750 SamplerSupplied SeparatelyDetector Fitted with gas collectorcone and remote gassing facilityGAS COLLECTORCONESGas collector cones are available to fit all IGD Gas Detectors. Theyare typically used when detecting lighter than air gases to enhancedetection capability. Collector cones are fitted to detectors placedover specific items of equipment where leaks may be expected.Some examples could be: boiler plant, valve stations, gas bottles,gas boosters, valve trains etc. Typically the detector fitted with itscollector cone would be mounted 1.0 to 1.5M above the equipment tobe monitored.100DIMENSIONSCatenary Wire Support PlatesTOCSIN102 & 903400Order Collector ConePN:401061& Guard PN 401051TOCSIN750 & 30TOCSIN750XDetector Guard &Collector Cone OrderPN: TOC-750-GDOrder Collector ConePN:401061& Guard PN 401051500Min 1000 - Max 2500Gas Collector Cones PN 401061140Available Sample Take off Points Bulkhead Provided for 6m OD x 4mm IDPolyurethane Tubing for Samplers, Direct Mount for 750 Series Detectorsor Location Points for ATEX Detectors.ORDER CODESPart NumberDescriptionTOC-GAS-05Gas Hood Length 0.5MTOC-GAS-HDGas Hood Length 1.0MTOC-GAS-HD15Gas Hood Length 1.5MTOC-GAS-HD2Gas Hood Length 2MTOC-GAS-HD25Gas Hood Length 2.5MTOC-GAS-HD3Gas Hood Length 3.0MTOC-GAS-HD35Gas Hood Length 3.5M5150211Hood Sample Point, Filter & TubingDia 400mmNote RequiresCorrect Adaptor ToFit DetectorRemote Gassing Port PN TOC-30-RMGUse where mounting height of the detector makes calibration access a problem.Supplied with 6M of tubing, Clips, Bulkhead fitting and TOC-750-GD1

AccessoriesProduct DataSPL ASH GUARDSSPECIFICATIONSDocument Ref: SL-051 erialABSTemperature RangeSee T102 DataTemperature RangeSee TOC-750 DataRatingTo IP65RatingTo IP55In addition we also supply collector cones for lighter than air gases.These are fitted to sensor to aid the sensor in detection of lighterthan air gases such as methane or hydrogen. The collector coneworks by funnelling the gas to the sensor. These have beendesigned to be fitted with ease using the appropriate splash guard.DIMENSIONS401451 Splash Guard MKIII, 102 and Type BIGD has designed a range of state of the art Splash Guards toprovide additional IP protection where required for detectors. Theseare used in areas where either splashes, dust or draught are aconcern. These are designed to be easily installed with push orscrew on fitting meaning minimal training is required.TOC-750-GD1 Splash GuardPN: 401451Note Calibration PortAlso use when fitting gascollector cones to ATEXdetectors (PN:401061)102 or MK3Series DetectorEEx d IIC T6IP66Rating 6W MaxSira 02ATEX1271XSerial Number 102-xxxxx-20020518Push FitII 2 GDNote Correct Orientation75mmOptional Disk Filter for HighDust EnvironmentsPN: 40146550mmRemove Splash GuardWhen Calibrating22mmORDER CODEPart NumberDescription401451Weather Protection for MKIII, Type B & 102 Series Gas DetectorsTOC-750-GDCollector Cone for 750 Series Detectors With Splash GuardTOC-750-GD1Splash guard for 750 Series Detectors401465Disk FilterPN: TOC-750-GD1Please Note: Image for illustration purposes only

AccessoriesProduct DataSPECIFICATIONSBEACON SOUNDERSDocument Ref: SL-051 V5Base ColourRedIP RatingIP65Lens ColourAmberCable Entries2 X 20mmAudibility @ 1MUp to 106 dBTemperature-25 deg C to 70 deg CTones32RatingContinuousVoltage17-60V DCFrequency400 to 2850 Hz SelectableSounderCurrent45mA MaxConstructionFlame Retardant PolycarbonateBeaconCurrent5mAIGD can supply beacon sounder(s)/Audible Visual alarms to enhance yoursystems safety features. They provide additional visual and audible signalsto assist in alerting personnel and aiding evacuation, in the event of analarm and are ideal for any situation. The beacon sounder(s) are alsosupplied with laser engraved signage to further indicate that the specifiedbeacon is for a gas alarm. IGD believes it is best practice to place onebeacon outside any entrance to the zone/area and appropriate numbersinside. This approach alerts persons inside an area to evacuate on alarmand provides warning at the entry points to the area. IGD beacon sounderscan be wired directly to 750 series detectors. Setup allows for mutablesounders on alarm whilst leaving beacons running.DIMENSIONS104M20 Side Entry Points97.539M20 Rear Entry Point50284.2 Fixings17ORDER CODEPart NumberDescription5083101Beacon Sounder 17-60BV DC Amber/RedAll IGD Beacon Sounders come witha laser cut legend plate, which canbe customised for your needs.

AccessoriesProduct DataDIMENSIONSDocument Ref: SL-051 V5CALL POINTS & RESET BUTTONSPlease Note: all measurements in mmIGD Call Points are designed to compliment IGD gas detection systems there are twoversions of our emergency call points available.TOC-750-CP2: This version offers illumination and a sounder option. Green when normaland red when triggered with optional sound alarm, clear indication of the call point status.GASALARMTOC-CALL-YEL: This version is a more conventional call point with mechanical indicationonly to show that it has been activated.9510560IGD can provide remote reset buttons to go along side your fixed gas detection system. Theremote reset button allows users to remotely reset a gas alarm activation without going backinto the control panel. For large multi detector systems this can save time and improve siteproficiency and safety.9078Both call points have protection shrouds and mechanical key reset. IGD Call Points easilyinterface to 750 series detector nodes as part of an integrated gas detection system.Please Note: all measurements in mmFEATURESIGD Call Points and reset buttons are designed to be easy to install,working alongside IGD Systems. They interface directly to 750Series Detectors and 750 Series Controllers.78IGD Call Points are illuminated, providing a visual indication whenone has been tripped. They also have a built in audible alarm. Thismakes trip identification much easier.73Alternately a unit is available with mechanical trip indication.20Both units require a ket to reset.ORDER CODEPart NumberDescriptionACC1001209Wall Mount E-Stop ButtonTOC-CALL-YELLYellow Call PointTOC-750-CP2Illuminated Call PointTOC-RESETRemote Reset ButtonTOC-RESETTOC-750-CP2TOC-CALL-YELL

AccessoriesProduct DataDETAILSDocument Ref: SL-051 V5PITOT TYPE DUCT ADAPTERSThe Pitot duct adaptor relies on the gas velocity in a process toinduce a flow in the probe to deliver gas to the gas detector. Typicalapplications are ventilation duct monitoring or air intakes in a varietyof processes. With this type of unit the detector is remote from thePitot assembly by tubing. This is particularly useful where mountingonto sheet metal duct work when access to the detector will still berequired.SPECIFICATIONSATEX pitot adaptorimage shown fitted toa 102 Series DetectorPN: 5139002Safe area pitot adaptorimage shown on and offthe detectorPN: TOC-30-DCTAir FlowDuct Mounting Hole Detail316St Stl, Norprene(PTFE Option), ABSTube LengthMax 150mmMin Flow3M-1Max Flow20M-1Min Process Temp3 Deg CMax Process Temp70 Deg CHumidity95%RH Non CondensingParticulate50mg/CU MORDER CODES30.0APPLICATIONSØ10.0MaterialsPart NumberDescription5139002Pitot Duct Adaptor For Use With 102 Seriesand MK3 ATEX Gas DetectorsTOC-30-DCTPitot Duct Adaptor for use with TOC-750and TOC-30 Series Detectors, safe areaVentilation Duct MonitoringDrill for M4Fasteners orNo6 SelfTappingScrewAir Intake MonitoringProcess Extract MonitoringAbatement System Monitoring15.0Glove Box Extract Monitoring

AccessoriesProduct DataDocument Ref: SL-051 V5DIMENSIONSPIPE IN PIPE17mmADAPTERCalibration Port Supplied BlankedIGD’s Pipe-in-Pipe adaptor is designed to enable detectors tomonitor the interstitial gap in double containment pipe systems. Theadaptor is supplied pre-fitted to either 750 Series, TOC-30 Series orTOC-10 Series Detectors. As indicated in the enclosed picture thesensor is mounted on a tee branched off from the underside of thecontainment pipe. A plug at the bottom of the tee seals the systemand can be removed to vent the interstitial gap during maintenanceand calibration. A calibration port is provided to allow an easymethod to test the detector without removing it from the system.Note that the adaptor is supplied with a 3/4” male thread. Pipefittings to mate to the outer containment pipe are not provide asthese may vary depending on the containment system.DIAGRAMORDER CODE90mmThe below illustrates how a pipe in pipeadapter functions in a system with aT10-LPG-23RPR and the correspondingremote sensor.Tee piece and plugsupplied by othersto suit install3 Core cable1.5mm SqMax 20m lengthPart NumberDescriptionT10-LPG-23RPRRemote Sensor VersionTOC-750R-MK7Remote SensorTOC-PIPMK7 Pipe in Pipe AdaptorAdapter Supplied with a3/4” BSP male threadTOC-PIPMK7 Pipe in Pipe Adaptor

AccessoriesProduct DataSPECIFICATIONSAT E X J U N C T I O N B O X E SDocument Ref: SL-051 V5Box ColourWhiteMaterialAluminium Pressure Die CastingMax 0.5% MgIP RatingIP68 (Silcone O Ring Lid Seal)Entries3 of M20 x 1.5ConstructionFlame proof EExd threadsMountingWall MountedWeight1.1 KGOur ATEX Junction Boxes allows you to mount our 102 or MKIII seriesATEX sensors in zone 1 and 2 explosive areas and zone 21 and 22 dustenvironments. Further to this the ATEX Junction Box is also used forinstalling local nodes in the same environments. Giving distributed controlin ATEX zoned areas.To note, nodes allow you to control third party equipment such as localaudible visual alarms, solenoid valves, 4-20mA input devices and more.DIMENSIONSAPPROVALSPlease Note: Mounting details shown with MKIII Gas Detector145.0126.0JB3/903II 2G Ex db IIC T6/T5 GbII 2D Ex tb IIIC T85ºC/ T100ºC DbTa -20ºC to 40ºC/ 55ºCIECEx EXV 16.0002XExVeritas 16 ATEX 0140XExVeritas 21UKEX0913XIP66M20 x 1.5 Entries 12-32V DCCompliant to IEC 60079-29-1COVER SECURING SCREWM20 x 1.5128.525.0280440.0128.0Ø7.0Ø110EXTERNAL EARTH40.0MKIII FLAMMABLEGAS DETECTORSHOWNORDER CODEPart NumberDescription5045802Standard IGD ExD Junction Box ATEX 3 Terminals5045803316 Stainless Steel Version ATEX 3 TerminalsPlease Note: Image for illustration purposes only2585

AccessoriesProduct DataDocument Ref: SL-051 V5DIMENSIONSATEX ENCLOSURE OR HEADSPACE ADAPTERSType 3 Duct AdaptorPN: 5133801Type 3 duct adaptors rely on gas diffusion to the detector. Typicalapplications are head space monitoring in tanks, vessels or ductwork. The clamp flange arrangement allows easy removal of thedetector for service access and during fitment to the process. Internalbaffles protect the detector and allow the optional fitting of filters ifrequired.dtL DGI REVILOdnalgnE ,tropkcotS ,dR reppeP a42002-xxxxx-201 rebmuN laireSTypical ATEX Applications Could Include:OCWeld or Brazeprobe mountingtube to wall.001-0mpp8150Vessel Head Space MonitoringGas Storage Cabinet MonitoringMonitoring From Fume Hoods150mmThrough Wall Monitoring90mmAdaptor PN:5133801Shown Fitted to 102Series Detector and750XD ATEX Display25.4Min 25mmCalibration PortAPPLICATIONSHEADSPACEORDER CODECABINETPart NumberDescription5133801Type 3 Duct Adaptor 25.4mm Tube End5133601Type 5 Duct Adaptor 1"BSP Tube EndClamp FlangeSPECIFICATIONSHead SpaceMonitoring inVesselsGas BottleEnclosure andFume HoodMonitoringMaterials316St Stl, SiliconeTube LengthMax 150mmMin Temp-20 Deg C (general see detector specification)Max Process Temp 55 Deg C (general see detector specification)

AccessoriesProduct DataDocument Ref: SL-051 V5PROFESSIONAL CALIBRATION KITS & GAS BOTTLESPart NumberDescriptionPart NumberDescription5137201Calibration Gas Bottle as;50ppm CO, 1% CH4 (20% LEL),18% Oxygen, 5000ppm CO25137201RCalibration Gas Bottle as;50ppm CO, 1% CH4 (20% LEL),18% Oxygen, 4000ppm Co2514180125ppm H2S514240210ppm Isobutylene51424013000ppm Isobutylene511500110ppm NO2511410125ppm NOZero Gas Bottle, NitrogenAdapters, Hose, Regulator, Case5142301Calibration Gas Bottle as;25ppm Iso-ButyleneZero Gas Bottle, NitrogenAdapters, Hose, Regulator, Case512460151419011000ppm R134Calibration Gas Bottle as;3000ppm Iso-Butylene5142201NitrogenZero Gas Bottle, Nitrogen514250120% LEL Butane51421011800ppm Hydrogen5139301Instrument Grade AirAdapters, Hose, Regulator, CaseBUMP TEST KITS & GAS BOTTLESPart NumberDescriptionPart NumberDescriptionTOC-GAS-KITCalibration Gas Bottle as;50ppm CO, 1% CH4 (20% LEL),18% Oxygen, 4000ppm CO2TOC-GAS-MIXCalibration Gas Bottle as;50ppm CO, 1% CH4 (20% LEL),18% Oxygen, 4000ppm Co2Zero Gas Bottle, NitrogenTOC-GAS-N2Zero Gas Bottle, NitrogenC A L I B R AT I O N K I T S& GAS BOTTLESIGD provide gas calibration kits and replacement gas bottles to support ourrange of gas detectors. Kits are available as either Professional Kits oruser Bump Test KitsBump Test Kits are intended for clients who want to test or provedetector operation but not necessarily calibrate (bump test). Bottlessupplied are 1L water volume cylinders typically containing 12L ofcompressed gas. These bottles contain enough gas for 6 Tests.Kits are supplied with a full set of IGD detector calibration gasadaptors, flow valve and hose. The set is supplied in a storagecase. Each kit is supplied with a bottled calibration gas and zerogas, usually pure Nitrogen.Professional Kits are intended for engineers who undertake regularcalibration of detectors as part of a traceable calibration operation.Bottles supplied are 1.55L water volume cylinders typicallycontaining 112L of compressed gas. These bottles typically containenough gas for 80 calibrations. Kits are supplied with a full set ofIGD detector calibration gas adaptors, 0.5L per Minute flowregulator and hose. The set is supplied in a storage case capable ofhousing up to 3 gas bottles. Each kit is supplied with a bottledcalibration gas and zero gas, usually pure Nitrogen.Adapters, Hose, Regulator, CaseSPARESPart NumberDescription5022001Regulator for Professional Kit5033001Flow Valve for Bump Test Kit4011109Calibration Adapter for TOC-10, TOC-30, MK7 Detectors401101ACalibration Adaptor for 102 Series Detectors4011103Calibration Adaptor for Mk6 Detectors401101BCalibration Adaptor for 103 Series Detector401101FCalibration Adaptor for 101 Series Freon Detector401101ZCalibration Adaptor for Zirconia Probes (Tocsin 950)Typical Professional Cal KitTypical Bump Test Kit

ALARM 90 95 105 60 TOC-RESET 20 73 78 78 Please Note: all measurements in mm IGD can provide remote reset buttons to go along side your fixed gas detection system. The remote reset button allows users to remotely reset a gas alarm activation without going back into the control panel. For large multi detector systems this can save time and .