Testing and certification of, consultancy andresearch concerning, electronic and electricappliances, systems, installations andtelecommunication systemsTEST REPORT CONCERNING THE COMPLIANCE OF ASMART CARD TRACER, ANALYZER, SIMULATOR,BRAND COLLIS, MODEL SMARTLINK BOXWITH 47 CFR PART 15 (JULY 10, 2008).10041605.fcc01 Rev01June 07, 2010FCC listedIndustry CanadaVCCI RegisteredR&TTE, LVD, EMC Notified Body::::908282932G-1R-1518, C-15981856TÜV Rheinland EPS B.V.P.O. Box 159822 ZG Niekerk (NL)Smidshornerweg 189822 TL Niekerk (NL)Telephone: 31 594 505005Telefax: 31 594 504804E-mail: info@tuv-eps.comWeb: www.tuv-eps.comProject number: 10041605.fcc01 Rev01Page 1 of 15

Test specification(s):Description of EUT:Manufacturer:Brand mark:Model:FCC ID:FCC Part 15Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink BoxXKD-SMARTLINKBOXMEASUREMENT/TECHNICAL REPORTCOLLISModel : SmartLink BoxFCC ID: XKD-SMARTLINKBOXJune 07, 2010This report concerns:Original grant/certificationClass 2 changeVerificationEquipment type: JPB Class B digital deviceReport prepared by:NameCompany nameAddressPostal code/cityMailing addressPostal code/cityCountryTelephone numberTelefax numberE-mail: Richard van der Meer: TÜV Rheinland EPS B.V.: Smidshornerweg 18: 9822 TL Niekerk: P.O. Box 15: 9822 ZG Niekerk: The Netherlands: 31 594 505 005: 31 594 504 804: info@tuv-eps.comThe data taken for this test and report herein was done in accordance with 47 CFR Part 15 (july 10, 2008)and the measurement procedures of ANSI C63.4-2003. TÜV Rheinland EPS B.V. at Niekerk, The Netherlands,certifies that the data is accurate and contains a true representation of the emission profile of the Equipment UnderTest (EUT) on the date of the test as noted in the test report. I have reviewed the test report and find it to be anaccurate description of the test(s) performed and the EUT so tested.Date:June 07, 2010Signature:O. HoekstraSenior Engineer Telecom TÜV Rheinland EPS B.V.Project number : 10041605.fcc01 Rev01Page 2 of 15

Test specification(s):Description of EUT:Manufacturer:Brand mark:Model:FCC ID:FCC Part 15Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink BoxXKD-SMARTLINKBOXDescription of test itemTest itemManufacturerBrandModel(s)Serial number(s)Revision::::::Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink Box::::::::::Mr. R. JozefzoonCollis B.V.De Heyderweg 12314 XZLeidenThe Netherlands 31 71 581 36 36 31 71 581 36 30info@collis.nlwww.collis.nlLocationTest(s) startedTest(s) completedPurpose of test(s)::::NiekerkApril , 2010May 18, 2010Equipment Authorization (Original grant/certification)Test specification(s):47 CFR Part 15 (July 10, 2008)Test engineer(s):R. van der MeerReport written by:R. van der MeerReport date:June 07, 2010n.a.n.a.Applicant informationApplicant’s representativeCompanyAddressPostal codeCityCountryTelephone numberTelefax numberEmailInternetTest(s) performedThis report is in conformity with NEN-EN-ISO/IEC 17025: 2005This report shall not be reproduced, except in full, without the written permission of TÜV Rheinland EPS B.V.The test results relate only to the item(s) tested.Project number : 10041605.fcc01 Rev01Page 3 of 15

Test specification(s):Description of EUT:Manufacturer:Brand mark:Model:FCC ID:FCC Part 15Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink BoxXKD-SMARTLINKBOXTable of contents1234567General information. . 51.1Product description. 51.1.1Introduction. . 51.2Related submittal(s) and/or Grant(s). . 51.2.1General. . 5Tested system details. . 52.1.1Description of input and output ports. . 72.2Test methodology. . 82.3Test facility. . 82.4Test conditions. . 8System test configuration. . 93.1Justification. . 93.2EUT mode of operation. . 93.3Special accessories. 93.4Equipment modifications. . 93.5Product Labelling. 93.6Block diagram of the EUT. . 93.7Schematics of the EUT. 93.8Part list of the EUT. . 9Radiated emission data. . 104.1Radiated field strength measurements (30 MHz – 1 GHz, E-field) . 10Conducted emission data. . 125.1Conducted emission data of the EUT . 12List of utilized test equipment. . 14Conclusion . 15Project number : 10041605.fcc01 Rev01Page 4 of 15

Test specification(s):Description of EUT:Manufacturer:Brand mark:Model:FCC ID:1General information.1.1Product description.1.1.1FCC Part 15Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink BoxXKD-SMARTLINKBOXIntroduction.The Smart card Tracer, Analyzer, Simulator, brand Collis, model SmartLink Box, does not hold any transmitter andcan be classified as a Class B Digital Device. The SmartLink Box is a hardware tool for testing smart cards andterminals. It can be used for testing, analysing, intercepting, modifying, and simulating communication signalsexchanged between a smart card and a terminal. A PC with a software package, the TEST REPORT , is set up byplacing Collis SmartLink Box (in the case of contactless cards) in between the card and the terminal/reader. Thispicks up the communication between the two entities and sends it to the PC where the TEST REPORT software isrunning.The content of this report and measurement results have not been changed other than the way of presenting the data.1.2Related submittal(s) and/or Grant(s).1.2.1General.This test report supports the original grant/certification in equipment authorization files under FCC ID: XKD-SMARTLINKBOX.2Tested system details.Details and an overview of the system and all of its components, as it has been tested, may be found below.EUTManufacturerBrandModelSerial numberVoltage input ratingVoltage output ratingCurrent input ratingAntennaRemarks::::::::::Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink Boxn.a.5 Vdcn.a.not providednone--AUX1ManufacturerBrandModelSerial numberRemark::::::USB hardware keyCollis B.V.CollisN.a.0.13.909.Connect to AUX4, for enabling software onlyAUX2ManufacturerBrandModelsSerial numberVoltage input ratingCurrent input ratingRemark::::::::SCM Contact(less) Reader with Collis Test CardCollisCollis--------Connect to AUX4 with USB cableProject number : 10041605.fcc01 Rev01Page 5 of 15

Test specification(s):Description of EUT:Manufacturer:Brand mark:Model:FCC ID:AUX3ManufacturerBrandModelsSerial numberVoltage input ratingCurrent input 00-240Vac 50/60Hz18Vdc/840mAConnect to EUTAUX4ManufacturerBrandModelsSerial numberVoltage input ratingCurrent input ratingRemarkSoftware:::::::::LaptopLenovoLenovoIBM ThinkPadL3-BF847 07/0218Vdc18Vdc/5A-Collis Card Spy v1.0FCC Part 15Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink BoxXKD-SMARTLINKBOXNote: 1 (USB cable between EUT and AUX4) is marketed with the EUT Details of “1” are as follows:USB cable Brand:Tyco Electronics – part: 1487588-2Ferrite bead:Würth Elektronik – part: 742 7114AUX4AUX3AUX1EUTAUX21Photograph of the systemProject number : 10041605.fcc01 Rev01Page 6 of 15

Test specification(s):Description of EUT:Manufacturer:Brand mark:Model:FCC ID:2.1.1FCC Part 15Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink BoxXKD-SMARTLINKBOXDescription of input and output ports.NumberTerminalFromToRemarksCable 1.5m, includes aferrite bead1USBAUX4EUT2USBAUX1AUX4For enabling software3Link cableAUX4AUX2Cable 60cm4RS-232EUTAUX4Data connectionUSBkey32LaptopSmartLink BoxCardman1TestCard4AdapterMainsFigure 1. Basic set-up normal useProject number : 10041605.fcc01 Rev01Page 7 of 15

Test specification(s):Description of EUT:Manufacturer:Brand mark:Model:FCC ID:2.2FCC Part 15Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink BoxXKD-SMARTLINKBOXTest methodology.The test methodology used is based on the requirements of 47 CFR Part 15 (july 10, 2008), sections 15.31, 15.107 and 15.109.The test methods, which have been used, are based on ANSI C63.4: 2003.Radiated emission tests above 30 MHz were performed at a measurement distance of 3 meters.Radiated emission tests below 30 MHz were performed at a measurement distance of 3 meters. To calculate the field strengthlevel from these results to the appropriate distance at which the limit is specified, the appropriate extrapolation factor is used.The receivers are switching automatically to the right bandwidth in accordance with CISPR 16. This is implemented in thereceiver. The antenna factors are programmed in the test receiver. The receiver automatically calculates the appropriatecorrection factor for the utilized antenna and also the appropriate antenna factor for the cable loss. The total correction isautomatically added to the measured value.2.3Test facility.The Federal Communications Commission and Industry Canada has reviewed the technical characteristics of the test facilitiesat TÜV Rheinland EPS B.V., located in Niekerk, 9822 TL Smidshornerweg 18, The Netherlands, and has found these testfacilities to be in compliance with the requirements of 47 CFR Part 15, section 2.948, (10-1-06 edition).The description of the test facilities has been filed at the Office of the Federal Communications Commission under registrationnumber 90828. The facility has been added to the list of laboratories performing these test services for the public on a fee basis.The description of the test facilities has been filed to Industry Canada under registration number 2932G-1. The facility has beenadded to the list of laboratories performing these test services for the public on a fee basis.2.4Test conditions.Normal test conditions:Temperature (*)Relative humidity(*)Supply voltageAir pressure: 15 C to 35 C: 20 % to 75 %: 120VAC/60Hz: 950 – 1050 hPa*When is was impracticable to carry out the tests under these conditions, a note to this effect stating the ambienttemperature and relative humidity during the tests are stated separately.Project number : 10041605.fcc01 Rev01Page 8 of 15

Test specification(s):Description of EUT:Manufacturer:Brand mark:Model:FCC ID:3System test configuration.3.1Justification.FCC Part 15Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink BoxXKD-SMARTLINKBOXThe system was configured for testing in a typical fashion (as a customer would normally use it).The EUT is not AC powered, however Conducted Emissions is tested in combination with a laptop computer that supplies theEUT with power from the USB port. By this means it can be investigated if any emissions from the EUT is conducted to themains through a host.The justification and manipulation of cables and equipment in order to simulate a worst-case behavior of the test setup has beencarried out as prescribed in ANSI C63.4: 2003.3.2EUT mode of operation.The EUT has been tested as table Top Equipment . The unintentional radiator tests (47 CFR Part 15 sections, 15.107 and15.109) have been performed with a complete functioning EUT and interconnections.3.3Special accessories.No special accessories are used and/or needed to achieve compliance.3.4Equipment modifications.No modifications have been made to the equipment in order to achieve compliance.3.5Product LabellingThe product labeling information is available in the technical documentation package.3.6Block diagram of the EUT.The block diagram is available in the technical documentation package.3.7Schematics of the EUT.The schematics are available in the technical documentation package.3.8Part list of the EUT.The part list is available in the technical documentation package.Project number : 10041605.fcc01 Rev01Page 9 of 15

Test specification(s):Description of EUT:Manufacturer:Brand mark:Model:FCC ID:4FCC Part 15Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink BoxXKD-SMARTLINKBOXRadiated emission data.4.1 Radiated field strength measurements (30 MHz – 1 GHz, 5.90867.90Measurement Measurementresults @3m results raftercorrection correctionVertical Horizontal(dBuV/m) ssPassPassTable 1 Radiated emissions of the EUT.The results of the radiated emission tests, carried out in accordance with 47 CFR Part 15 section 15.109 aredepicted in Table 1. The system is tested without AUX 2 and AUX4 and the associating cables. AUX2 and AUX4were only used in the situation for programming the EUT for continues transmitting.Notes:1. Field strength values of radiated emissions at frequencies not listed in the table above are more than 20 dBbelow the applicable limit.2. Measurement uncertainty is 5.0dB3. The reported field strength values are the worst case values at the indicated frequency. The EUT wasvaried in three positions, the antenna was varied in horizontal and vertical orientations and also in height(between 1m and 4m).4. A Quasi-peak detector was used with a resolution bandwidth of 120 kHz, except for frequencies above 960MHz where an average detector was used.4.1.1.1Test equipment used (for reference see test equipment listing section oject number : 10041605.fcc01 Rev01Page 10 of 15

Test specification(s):Description of EUT:Manufacturer:Brand mark:Model:FCC ID:FCC Part 15Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink BoxXKD-SMARTLINKBOXTest engineerSignature:NameDate: Richard van der Meer: May 12, 2010Project number : 10041605.fcc01 Rev01Page 11 of 15

Test specification(s):Description of EUT:Manufacturer:Brand mark:Model:FCC ID:5FCC Part 15Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink BoxXKD-SMARTLINKBOXConducted emission data.5.1 Conducted emission data of the .630Measurement resultsdB(µV)NeutralQPAV28.2 2036.622.637.2 2041.6 2031.4 2029.8 2428.423.426.623.6Measurement resultsdB(µV)Line 1QPAV 20 2039.8 20 20 2041.022.028.2 20 20 21.0 2021.0 2012.6 ASSPASSPASSPASSPASSTable 2 Conducted emission measurements.The results of the conducted emission tests, carried out in accordance with 47 CFR Part 15 section 15.107, at the120 Volts AC mains connection terminals of the AC/DC power supply which was connected to the PC which in turnsupplies the EUT with power through USB, are depicted in Table 2. Maximum values recorded. The system istested as in whole, so with all equipment as shown in Figure.1 in place and functioning. Being the worst casesituation.Notes:1. Measurement uncertainty is 3.5dB2. The resolution bandwidth used was 9 kHz.3. Values of conducted emissions at frequencies not listed in Table 2 are more than 20 dB below theapplicable limit.5.1.1.1Test equipment used (for reference see test equipment listing section 6).1249112493125121331399161995489961599663Project number : 10041605.fcc01 Rev01Page 12 of 15

Test specification(s):Description of EUT:Manufacturer:Brand mark:Model:FCC ID:FCC Part 15Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink BoxXKD-SMARTLINKBOXPlot 1: Plot of the conducted emissionsTest engineerSignature:Name: R. van der MeerDate: May 18, 2010Project number : 10041605.fcc01 Rev01Page 13 of 15

Test specification(s):Description of EUT:Manufacturer:Brand mark:Model:FCC ID:6FCC Part 15Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink BoxXKD-SMARTLINKBOXList of utilized test 99613996159966399699DescriptionBrandModelMeasuring receiverSpectrum monitor ESH3LISNPulse LimiterBiconilog BL 6111BCoax 5m RG213 OATSCoax 15m RG213 OATSCoax OATS groundController OATSVariac 250V erOATSController (OATS)Antenna mastTemperature-HumiditymeterLaptopNMi Certin B.V.KABEL 5M OATSNMi Certin B.V.KABEL 15M OATSLaptopMeasuring receiverNMi Certin B.V.KABEL GROND OATSHeinrich DeiselIBM4630-100LTS006WS-7082WS-7082FCC listed: 90828DOC202AP-4702CWS-7082Lenovo 9456-HTGDELLR&SLatitudeESCIRFTEurope suppliesEurope suppliesComtestEMCSEMCSEurope suppliesLast cal.Next NA Not ApplicableProject number : 10041605.fcc01 Rev01Page 14 of 15

Test specification(s):Description of EUT:Manufacturer:Brand mark:Model:FCC ID:7FCC Part 15Smart card Tracer, Analyzer, SimulatorCollis B.V.CollisSmartLink BoxXKD-SMARTLINKBOXConclusionThe EUT complice with the requirements of the FCC regulations in accordance with 47 CFR Part 15 (july 10, 2008)and the results are deemed satisfactory evidence of compliance with Industry Canada Interference-CausingEquipment Standard ICES-003.Project number : 10041605.fcc01 Rev01Page 15 of 15

Test specification(s): Description of EUT: Manufacturer: Brand mark: Model: FCC ID: FCC Part 15 Smart card Tracer, Analyzer, Simulator Collis B.V. Collis SmartLink Box XKD-SMARTLINKBOX Project number : 10041605.fcc01_Rev01 Page 3 of 15 Description of test item Test item : Smart card Tracer, Analyzer, Simulator Manufacturer : Collis B.V.