Water Cooled Freecooling Chiller KW 39 634 - Swegon

Transcription

Tetris W FC/NG39 634 kWWater cooled freecooling chillerGeneralBullet pointsTetris W FC/NG is a freecooling chiller for indoor installation that integrates decoupling exchanger, 3-waymodulating valve, inverter pump on source side and advanced software to manage the system and remote aircooled exchanger. Plug and play indoor freecooling unitConfigurationsBase: unit with a Total Freecooling Temperaure of -2 CHE: unit with a Total Freecooling Temperaure of 1 CPump and integrated buffer tank available as option Hybrid freecooling: capability, in the mid seasons, tooperate in mixed mode freecoling/chiller Full completely integrated control for managing chiller, freecooling system and remote air cooled exchanger High efficiency in summer mode Two levels of freecooling efficiency and paybacktime Designed for easy indoor installation Glycol free on user side Wide capacity range

with lerdeilppSucoo .yrddtenitauciehdterdd foezimitopIndoor freecoolingThe ultimate freecooling experience

1 C100% FCexterntuarelHYBRIDFREE COOLINGtemperaTFT (100% FC)STD versionTA STD: 8 C*Nominal coolingcapacity [kW]STDTetris W FC / NG combinesall the advantages of high efficiency water-cooled chiller(Tetris W range) with the hybridfreecooling integrated systemTFT (100% FC)HE version Hybrid free Cooling 100% Free Cooling (Winter)T ext airHYBRID FREECOOLINGTA HE: 9 C*Nominal coolingcapacity [kW]HEUnit performs full nominal capacity with compressors operatingat part load with reduced powerconsumption.Unit performs full nominal capacity only using Dry Cooler fansand with compressors OFF.T ext airHYBRID FREECOOLINGFreecooling mode-2 CChiller modertialHighepcoaoling mode 1 CPartial Freecoolinghybrid freNOT ONLY FREECOOLINGaverageHigh efficiency in summer modeEER 4,7 *Nominal coolingcapacity [kW]ersummedomwinterspringFreecooling mode ONTETRIS W FC/NG HE 26.4Example for StockholmEnergy saving 41%Low billsLow carbon emissionyearsummerPartial FreecoolingTotal energyconsumption [kWh]Thanks to high performance of the chiller side, TetrisW FC/NG ensures high efficiency of the plant duringall the year. The productadapts and optimises itselfto the seasons, providing ahigh return all year round.autumnwinterFreecooling mode OFF25000Chiller Freecooling mode20000Chiller mode only150001000050000-25 -22 -19 -16 -13 -10 -7 -4 -1258 11 14 17 20 23 26 29 32External air temperature [C ]Here are a number illustrating the energy savingsfor Stockholm, in terms of energy consumption,achieved using TETRIS W FC/NG HE, in comparison to a water cooled standard unit, assuming thatthe cooling need is constant throughout the year.* Evaporator inlet-outlet water temperature 15-10 C; condenser inlet-outlet water temperature 30-35 C (e.g. 30%)

EASYINSTALLATIONINVERTERDRIVEN PUMPON SOURCE SIDEInverter driven pump on source side asstandard: Reduced energy consumption Greater control of condensing temperature in partial freecooling.Unit SizeCoolingNominal cooling capacity (1),(6) kW(1)EER(1),(6)EER (EN 14511-3:2011)Basic unit size and weightsmmLenghtmmWidthmmHeightUnit SizeCoolingNominal cooling capacity (1),(6) kW(1)EER(1),(6)EER (EN 14511-3:2011)Basic unit size and weightsmmLenghtmmWidthmmHeightGLYCOL FREEThanks to the built-in decoupling heatexchanger Tetris W FC/NG is Glycol freeon user side. This means: more efficiency on user side with onlywater the plant doesn’t need to be monitored(ethylene glycol is poisonous for humans)OUTINsourceuserNo GlycolAdvanced built-in control to manage the3-way modulating valve, inverter drivenpump on the source side and the fanspeed adjuster of the dry cooler.No need additional cost for controls integration.GlycolFULL INTEGRATEDCONTROL SYSTEMTetris W FC / NG provides a lot pof options and pumping configurations to suitevery requirements.The footprint is designed for indoor installation (max width below 900 mm).The structure provides also the divisionin two section for sizes long over 5 meters to allow an easy movement in interior spaces. This means: Less design time Quicker and less cost for installation team Few connections3.2 4.2 5.2 6.2 7.2 8.2 9.2 10.2 12.2 13.2 15.2 17.2 19.2 20.2 24.2 27.239455257667485 103 117 135 150 166 188 206 229 2584,69 4,66 4,74 4,77 4,72 4,73 4,78 4,79 4,78 4,79 4,82 4,79 4,76 4,67 4,66 4,694,10 4,01 4,14 4,18 4,20 4,09 4,17 4,23 4,31 4,26 4,29 4,23 4,24 4,17 4,26 4,231633 1633 1633 1633 1633 1633 1633 1633 3300 3300 3300 3300 3300 3300 3300 3300800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 8001880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 188030.3 34.3 40.3 18.4 20.4 24.4 26.4 30.4 34.4 38.4 40.4 48.4 54.4 56.6 60.6328 370 414 169 204 233 263 297 331 377 423 468 527 563 6344,81 4,84 4,86 4,74 4,72 4,77 4,77 4,78 4,75 4,72 4,73 4,62 4,70 4,73 4,734,37 4,35 4,36 4,22 4,33 4,34 4,23 4,39 4,23 4,29 4,23 4,28 4,29 4,28 4,284505 4505 4505 3685 3685 4502 4502 4502 45022820 29303320 2930880 880 880 880 880 880 880 880 880 880 880 880 880 880 8801880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880(1) Evaporator inlet-outlet water temperature 15-10 C; Condenser inlet-outlet water temperature 30-35 C (e.g.30%)(6) Values conform to EN 14511-3:2011This board reports the feature data of the base and standard versions; for details, refer to the specific documentation.

Hotel Sail CityBremerhaven - GermanyIndoor freecooling system - 2 water cooled chiller 2 water cooled freecooling chillerSupply - 1 MW

Blue Box technological product rangefind out the complete product range on our web site and cataloguesZeta Echos FC 44 143 kWHigh efficiency air cooled freecooling chillers. Patented system.Tetris FC series 97 518 kWHigh efficiency air cooled modular freecooling chillers.Kappa V Evo FC 325 1178 kWHigh efficiency air cooled freecooling chillers.Kappa Rev HEi & XEi 286 1451 kWAir cooled chillers and heat pumps with Inverter compressor.INVERTERTetris W FC/NG 39 634 kWHigh efficiency water cooled freecooling chillers with integrated hydronicmodule.Blue Box Group S.r.l.Via Valletta, 5 - 30010 Cantarana di Cona, (VE) Italywww.bluebox.it - info@bluebox.itPhone 39 0426 921111 - Fax 39 0426 302222

Water cooled freecooling chiller Bullet points Plug and play indoor freecooling unit Hybrid freecooling: capability, in the mid seasons, to operate in mixed mode freecoling/chiller Full completely integrated control for managing chil-ler, freecooling system and remote air cooled exchan-ger High efficiency in summer mode