Final Part 02 - Bharat REF

Transcription

CHILLING PLANTWe are leading refrigeration company dealing with the various kind of industrial chillers for end to endsolutions. We are Committed to provide best solution to customers, Which fulfill their needs. We have a widerange of air cooled & water cooled chillers. We have an ISO 9001 certified production unit. The range of ourchillers 5 Tr. to 200 Tr.Our chillers are ideal for various industries like Pharmaceuticals, Plastics, Foods & Beverages, Dairy & MilkProcessing, Chemical Industries etc.Modular Scroll ChillerChilling Plant ApplicationDairy & Beverages ApplicationsChemical IndustriesPharmaceutical IndustriesProcess IndustriesMineral Water ApplicationsPlastic Process IndustriesToll Free No.: 1800 102 4615info@bharatref.inwww.bharatref.in29

CHILLING PLANTMODEL CODE LOGICAC/WCSC030A2X1AIR COOLED/WATER COOLEDSCROLL COMPRESSORNO. OF COMPRESSORS(SC – SCROLL, RP – RECIPROCATING, SW – SCREW)REF. CIRCUITCAPACITY 30 TRREFRIGERANTS(A– R22, B – R404, C – R407, D – R134a)Note : No. of Comp. per Ref. Circuit : For Ex. 2X1 –Double Comp. per Single Circuit, 2X2 –Double Comp. per Double CircuitTable - 1 (Scroll Chiller – Air Cooled)RefrigerantSr.No.Model -/2X2ACSC100A-/2X2*Capacity(In Tr.)ABCDR22R404AR407AR134a OPOPOPOPOPOPOPOP5101520253040506080100No. of Comp. Per Ref. CircuitComp. Qty11111xxxxxxRef. Cct.x222222222211111111222AC – AIR COOLED, WC – WATER COOLED, SC – SCROLL, SW – SCREW, RP – RECIPROCATING OP - OPTIONAL, - IDEAL, X – NOTAPPLICABLE , EVAPORATOR – SHELL & TUBE TYPE, CONDENSOR – AIR COOLED / WATER COOLED (SHELL & TUBE TYPE )Table – 2 (Scroll Chiller – Water Cooled)RefrigerantSr.No.Model 0A-/2X2WCSC080A-/2X2WCSC100A-/2X2*Capacity(In Tr.)510152025304050607080100ABCDR22R404R407R134a OPOPOPOPOPOPOPOPOPOPOPCondenserNo. of Comp. Per Ref. Circuit Water Flow rateComp. Qty11111xxxxxxxRef. 0200022402800x22222222222Table – 3 (Screw Chiller – Air Cooled)Sr.No.01020330Model y(In Tr.)040050060RefrigerantABCDR22R404R407R134a OPOPOPOPOPOPOPOPOPToll Free No.: 1800 102 4615No. of Comp. Per Ref. CircuitComp.Qty.111xxxinfo@bharatref.inRef. Cct.111www.bharatref.in

CHILLING PLANTTable – 4 (Screw Chiller – Water Cooled)RefrigerantSr.No.Model No.*Capacity(In Tr.)ABCDR22R404R407R134aNo. of Comp. Per Ref. CircuitComp. QtyRef. Cct.CondenserWater Flow rate(LPM)x01 WCSW060A1/-X1060OPOPOP1680 11x02 WCSW075A1/-X1075OPOPOP112110 03 WCSW085A1/2X1085OPOPOP2112400 04 WCSW100A1/2X1OPOPOP2100112820 05 WCSW120A1/2X1OPOPOP2120113400 06 WCSW130A1/2X1OPOPOP2130113660 07 WCSW150A1/2X1OPOPOP2422015011 08 WCSW180A1/2X1OPOPOP2507011180 OPOPOP2565009 WCSW200A1/2X120011 Note1 : *Capacity rated on the base of water inlet temp. 15 C & water outlet temperature 10 C, Condensing temp. For watercooled system is 40 C & Air cooled system is 50 CNote2 : For Water Cooled chiller, Condenser water inlet temperature 30 C.Note3 : Chiller water/glycol outlet temperature ranging from -5 C to 12 C, For other temperature, higher ambient, othercapacity please refer to our sales team.Table – 5 (Glycol Chiller - Air Cooled)RefrigerantSr.No.01020304050607Model No.*Capacity(In Tr.)ABCDR22R404R407R134aOPOPOPOPOPOPOP 1ACRP030B1/-X1ACRP040B-/2X1ACRP060B-/2X1No. of Comp. Per Ref. CircuitComp. Qty11111xxx2x2222Ref. Cct.1111111Table – 6 (Glycol Chiller – Water Cooled)RefrigerantSr.No.Model No.*Capacity(In Tr.)ABCDR22R404R407R134aNo. of Comp. Per Ref. CircuitComp. QtyRef. Cct.CondenserWater Flow rate(LPM)x005OPOPOP22501 WCRP005B1/-X111 OPOPOP202 WCRP011B1/2X101011450 xOPOPOP65003 WCRP017B1/-X101511 875020OPOPOP21104 WCRP034B1/2X1 1025OPOPOPx1015105 WCRP044B-/2X1 106 WCRP068B-/2X1030OPOPOP214001 x175007 WCRP068B-/2X1040OPOPOP21 x08 WCRP068B-/2X1050OPOPOP220301 x09 WCRP068B-/2X1060OPOPOP228001 AC – AIR COOLED, WC – WATER COOLED, SC – SCROLL, SW – SCREW, RP – RECIPROCATING, OP - OPTIONAL,- IDEALX – NOT APPLICABLE , EVAPORATOR – SHELL & TUBE TYPE, CONDENSOR – AIR COOLED / SHELL & TUBE TYPENote 1 : *Capacity rated on the base of brine inlet temp. 5 C & outlet brine temp. 0 C, Condensing Temp. For water cooled system is 40 C &air cooled system is 50 C.Note 2 : For Water Cooled chiller, Condenser water inlet temperature 30 C.Note 3 : Chiller water/glycol outlet temperature ranging from -25 C to -5 C, For other temperature, higher ambient, other capacity please refer toour sales team.Table – 7 (Mineral Water Chiller - Air Cooled (Online & Offline)Sr.No.010203Model No.*Capacity(In Tr.)ACSW002A1/-X1ACSW003A1/-X1ACSW005A1/-X1Toll Free No.: 1800 102 4615235RefrigerantABCDR22R404R407R134a xxOPxxOPxxOPinfo@bharatref.inwww.bharatref.inNo. of Comp. Per Ref. CircuitComp.Qty.111xxxRef. Cct.11131

CHILLING PLANTController Options1) Microprocessor Based2) PLC Based (Applicable for Screw Chiller)(1) Microprocessor Based Controller :The LCD screen shows description of the controller parameters,and any other information concerning the controlled variables.Display Size : 2 Rows X 16 CharactersCharacter Size : 5.65 X 2.96 mmController has followingAnalog Inputs (Probe)COND IN –Indicates Condenser Inlet temperatureCOND OUT –Indicates Condenser Outlet temperatureWATER IN –Senses Water (Chiller) Inlet temperatureWATER OUT –Senses Water (Chiller) Outlet temperatureANTI FREEZE –Used as an Internal Anti Freeze ControlController has followingDigital Outputs (Relay)Chiller Pump ON/OFFCompressor1 ON/OFFCondenser Fan1 ON/OFFLiquid SV1 for Pump Down1Compressor2 ON/OFFLiquid SV2 for Pump Down2AlarmSystem Safety features (Trip Signals) High Pressure Low Pressure High Voltage Low Voltage Phase Failure Chiller Pump Overload Compressor Overload Condenser Fan Overload or Condenser Pump Overload Low Water Flow in Chiller Low Water Flow in Condenser Single Phase Prevent Antifreeze Trip Phase InputNote : Controller informs the user of a fault condition via a Buzzer and an Alarm Relay or by Massage on display(2) PLC Based Controller :Its programmable logic controller that is fully compatible (hardware and software), which includesprogrammable controllers, user terminals, gateways, communication devices and remote managementdevicesController has following Analog & Digital inputs :Suction Pressure, Discharge Pressure, Chiller Inlet, Chiller Outlet, Condenser Inlet, Condenser Outlet, AntiFreeze, Emergency Stop, Compressor OLR, HP Switch & LP Switch, Evaporator Flow, Condenser Flow,Condenser Pump Overload, Chiller Pump Overload.Self Identification Functions:1. All digital inputs & outputs such as Chiller Inlet, Chiller Outlet, Condenser Inlet, Condenser Outlet,current, Voltage, Low water flows in condenser etc.2. Trouble shooting identification function: - Show history of trips with date & time as well as cause of trips.Note : Other Customize inputs & outputs in controller, please refer to Ice Make sales team.32Toll Free No.: 1800 102 4615info@bharatref.inwww.bharatref.in

CHILLING PLANTRefrigeration CycleKey Features : Availability of Customized SolutionEco Friendly RefrigerantWide Range of Water/Glycol Temp. ( 15 C to -25 C)Closed Circuit operation Modular DesignEasy operation & less MaintenanceCompact in sizeWe are Dealing with Following Compressor1) Scroll Compressor ,Make : Emerson/Copeland & Danfoss or Equivalent2) Reciprocating CompressorType : Semi Hermetic & Hermetic sealedMake : Emerson/Copeland, Danfoss, Frascold & Bitzer or Equivalent3) Screw CompressorMake : Frascold & Bitzer or EquivalentDimple Plate in Tank Type ChillerEvaporatorCondenserWater Temperature RangeApplicationTank M.O.CInsulation::::::Dimple Plate Type ( S.S plate )Air Cooled/Water Cooled 2 C to 4 CFood & Bakery IndustryInner S.S 304 & Outer G.I.P.P./S.S 304PUFDimple Plate Type EvaporatorToll Free No.: 1800 102 4615info@bharatref.inwww.bharatref.in33

CHILLING PLANTAir Cooled V CondenserScrew ChillerAir Cooled Scroll ChillerWater Cooled Screw ChillerWater Cooled Screw Chiller34Air Cooled Screw ChillerAir Cooled Glycol ChillerWater Cooled Scroll ChillerModular Scroll ChillerToll Free No.: 1800 102 4615Air Cooled Scroll ChillerOnline Chilling PlantWater Cooled Glycol ChillerIndustrial Chilling Plantinfo@bharatref.inwww.bharatref.in

ICE BUILDING TANK (IBT)IBT is a system, which store energy in the form of ICE.It is applicable in Dairy Industry for quick process in short time with certain limit of power load.NO NEED OF CIVIL & FABRICATION WORK AT CUSTOMER SITEEASY TO LIFT & SHIFT l 40% ENERGY EFFICIENT l BETTER INSULATION(IBT- COIL IN TANK TYPE)(IBT- COIL IN TANK TYPE)Ice Building onEvaporator CoilIce Building onEvaporator CoilCopper TubeCopper TubeWater CirculationTOP VIEWAgitatorSIDE VIEWAdvantage: Required Less connected power load The ice water intensively cools the product without any risk Power supply is not required ones Ice Formation is Completed No requirement of Cooling Tower and Water Supply (For Air Cooled type) Wide capacity with Storage tank upto 1,00,000 LTR / 33,000 KG ice formation per day Cooling energy storage capacity upto 900 TR. / dayToll Free No.: 1800 102 4615info@bharatref.inwww.bharatref.in35

ICE BUILDING TANK (IBT)Material of Construction:Outer:A : Pre Coated GI sheet with PVC film thickness 0.5mmB : stainless steel sheet, grade 304, thickness 0.5mm.Inner:A : M.S. Sheet Thickness 2.4 to 6 mm with epoxy paints.B : S.S sheet, grade 304, Thickness 0.8 to 1.6mm.36REFRIGERATIONUNIT CAPACITY TR(TON REFRIGERATION)UNIT CAPACITY (TR)NO. OF UNITSSTIRRER SYSTEMTYPEICE PRODUCECAPACITY IN KG(AFTER 20 Hr. Working)COOLING STORAGECAPACITY IN TR.(TON REFRIGERATION)(At 2 C)BODY SIZE(INCHES)CONNECTEDPOWER LOAD(kw)Large graphic LCD screenFinger-touch menu with simple controlsContinuous, accurate display of each actionTANK CAPACITYLTR.PUF Insulation:The tank has 80mm insulation, which help to stopenergy loss & Lower Power Consumption.MODELProtection & Control accessories:SR NO.Buckets:M.S. angle & channel 65x5 mm to 100x8 mm with Paint.LTRTOTALTr.TYPEKGTr.TOTAL (LxWxH)Kw1IBT-501.55001.51.5 X 1Pump412.51245 x 35 x 392.42IBT-1002100022X1Pump5501765 x 35 x 392.783IBT-1003100033X1Agitator8252465 x 35 x 393.84IBT-2003200033X1Agitator8252693 x 45 x 393.85IBT-3003300033X1Agitator8252883 x 59 x 693.86IBT-2004200042X2Agitator11003493 x 45 x 395.87IBT-3004300042X2Agitator11003583 x 59 x 695.88IBT-3005300055X1Agitator13754383 x 59 x 696.29IBT-4005400055X1Agitator13754491 x 71 x 696.210IBT-4006400063X2Agitator16505291 x 71 x 697.811IBT-6006600063X2Agitator165055130 x 71 x 697.812IBT-60106000105X2Agitator275085130 x 71 x 6912.213IBT-80108000105X2Agitator275089170 x 71 x 6912.214IBT-1001010000105X2Agitator275092205 x 71 x 7012.215IBT-1001510000155X3Agitator4125130205 x 71 x 7018.616IBT-1201512000155X3Agitator4125133248 x 71 x 7018.617IBT-1502015000205X4Agitator5500176264 x 81 x 7024.818IBT-1802018000205X4Agitator5500181264 x 79 x 8324.819IBT-20026200002612.8 X 2Agitator7150229264 x 84 x 8627.220IBT-25038250003812.8 X 3Agitator10450328264 x 86 x 1034121IBT-28038280003812.8 X 4Agitator10450333264 x 95 x 10341Toll Free No.: 1800 102 4615info@bharatref.inwww.bharatref.in

Modular Scroll Chiller Toll Free No.: 1800 102 4615 info@bharatref.in www.bharatref.in 29. CHILLING PLANT MODEL . Air Cooled Scroll Chiller Online Chilling Plant Water Cooled Screw Chiller Water Cooled Glycol Chiller Air Cooled Glycol Chiller Industrial Chilling Plant 34 Toll Free No.: 1800 102 4615 info@bharatref.in www.bharatref.in .