With No Decrease In Initial Stability Initial Stability . - IBS Europe

Transcription

IBS Implant Catalog & Manual1Fast Bone Healing with No Decrease in Initial Stability2Initial Stability Through Morphologic Contact byRectangular Threads Regardless of Bone Quality3Outstanding Stress Distribution with Virtually No Shearing Force4Plentiful Bone Volume Between Threads5Convenient Placement due to “Self-Threading”26

27 IBS Implant Catalog & Manual0.1mm(Top View)Magic FC1mmStraight-tapered bodyCutting Edge Designed for maximum bonecontact and superior primarystability Self-Threading insertion withexcellent directional maintenanceSpecial Coronal Shape Prevention of marginal boneloss, increased cortical bonehealing ability0.1mmFIN THREAD0.8 0.9mm Improved strength ofbone between threads Balanced flexibilitybetween threads and bone Large volume of bone in contact with--implant results in superior stability(Front View) Cuts through bone and gainsstability by maximum bone-tothread contact regardless of bonequality. Stability without bonepressure

IBS Implant Catalog & Manual28Magic FC Drill Guide TableFixtureBone QualityØ 4.0mmSoft BoneØ 4.5mmØ 5.0mmØ 5.5mmØ 6.0mmØ ard BoneMagic FCMagic FC Precautions1. Insert the fixture in the pre-planned and drilled direction. Make sure to match the direction ofthe fixture to the angle of the placement hole by first placing the final drill into the placementhole to check and confirm direction. Then proceed with fixture placement.2. Only apply slight vertical pressure for the first 2mm of insertion. DO NOT apply verticalpressure during placement.3. Do not change directions while placing the implant.4. Maintain placement speed below 20rpm.5. Final torque is irrelevant to stability. Rather, the torque indicates bone quality. Dense bone willresult in high torque, whereas soft bone will result in low torqueMagic FC Mini (Ø3.0, Ø3.5)When using the FC Mini fixture, abutments have an increased cuff of 1mmFixture SizeD[Unit:mm]Fixture Diameter Ø3.0 re Diameter Ø3.5 11FCIBS3513FCL

29 IBS Implant Catalog & ManualFixture Diameter 011FC4013Magic FCFixture Diameter ture Diameter Ø6.5DiameterL[Unit:mm]Fixture Diameter Ø6.0DiameterDCodeFixture Diameter Ø5.5DiameterL[Unit:mm]Fixture Diameter 9FCIBS6511FCIBS6513FCFC6507FC6509FC6511FC6513L

IBS Implant Catalog & Manual30IBS Prosthetic SystemCemented type ProstheticsPair / Solid AbutmentAngled AbutmentTemporary AbutmentMagic AbutcopingMagic FCMagic ScrewMagic FCClosing ScrewHealing Abutment Short Long Sub Hex Impression Coping Short Long Sub Hex Impression CopingTransfer Type Hex / Non-Hex Hex / Non-Hex Temporary AbutmentAngled AbutmentLab AnalogPick-up TypeSolid AbutmentImpression Cap Pick-up / Transfer Type Pair AbutmentSolid AbutmentSolid AbutmentLab AnalogMagic Abutcoping

31 IBS Implant Catalog & ManualIBS Prosthetic SystemClosing Screw Prevention of foreign substance penetrating into fixture after placement Tighten by using 1.2 Hexa Driver and Torque Ratchet (5N 10N/cm)D[Unit:mm]CodeØ3.4HISC00FC MiniHISCMMagic FCØDiameterHealing Abutment Forming gingival shape after osseointegration Tighten by using 1.2 Hexa Driver and Torque Ratchet (5N ht(H)CuffCode3.51HISH 40014.52HISH 40025.53HISH 40036.54HISH 40043.51HISH 45014.52HISH 45025.53HISH 45036.54HISH 45043.51HISH 55014.52HISH 55025.53HISH 55036.54HISH 55043.51HISH 60014.52HISH 60025.53HISH 60036.54HISH 6004DCuffH

IBS Implant Catalog & Manual32IBS Prosthetic SystemPair Abutment Two piece type abutmentTighten with 1.2 Hexa driver (25N 30N/cm)Abutment Screw (OIAS400) includedHCuffMagic FCD[Unit:mm]ØDiameterHeight(H)Ø 4.0CuffCode1OSH 40142OSH 40243OSH 40344OSH 4044ØDiameterHeight(H)Ø 5.5CuffCode1OSH 55162OSH 55263OSH 55364OSH 55461OSH 65162OSH 65263OSH 65365.7Ø 4.51OSH 45142OSH 45243OSH 45344OSH 45444OSH 65461OSH 55141OSH 40182OSH 55242OSH 40283OSH 55343OSH 40384OSH 55444OSH 40481OSH 65141OSH 45182OSH 65242OSH 45283OSH 65343OSH 45384OSH 65444OSH 45481OSH 55182OSH 55283OSH 5538Ø 6.54Ø 5.5Ø 6.5Ø 4.0Ø 4.57.5Ø 4.01OSH 40162OSH 40263OSH 40364OSH 40464OSH 55481OSH 45161OSH 65182OSH 45262OSH 65283OSH 45363OSH 65384OSH 45464OSH 6548Ø 5.55.7Ø 4.5Ø 6.5

33 IBS Implant Catalog & ManualIBS Prosthetic SystemAngled Abutment Used to compensate for fixture placement direction errorTighten with 1.2 Hexa driver (25N 30N/cm)Abutment Screw (OIAS400) included[Unit:mm]Hex 215403154041525 1234HISAHISAHISAHISA4012540225403254042515 1234HISAHISAHISAHISA4511545215453154541525 1234HISA 45125HISA 45225HISA 4532515 1234HISAHISAHISAHISA5011550215503155041525 1234HISAHISAHISAHISA5012550225503255042515 Ø4.0Magic FCCuffØ4.5Ø5.0CuffHISA 45425D[Unit:mm]Non-Hex TypeØDiameterACodeAngleCuff15 1234NHSANHSANHSANHSA4011540215403154041525 1234NHSANHSANHSANHSA4012540225403254042515 1234NHSANHSANHSANHSA4511545215453154541525 1234NHSA 45125NHSA 45225NHSA 4532515 1234NHSANHSANHSANHSA25 1234Ø4.0Ø4.5Ø5.0ACuffNHSA 55032550425D

IBS Implant Catalog & Manual34IBS Prosthetic SystemSolid Abutment One-piece type abutmentProtection Cap (OISS) includedTighten with 1.2 Hexa Driver (25N 30N/cm)DHCuffMagic FC[Unit:mm]ØDiameterHeight(H)Ø 4.0CuffCode123HISS 40344HISS 4044ØDiameterHeight(H)CuffCodeHISS 40141HISS 5515HISS 40242HISS 55253HISS 55354HISS 55451HISS 65152HISS 65253HISS 6535Ø 5.55.5Ø 4.51HISS 45142HISS 45243HISS 45344HISS 45444HISS 65451HISS 55141HISS 40172HISS 55242HISS 40273HISS 55343HISS 40374HISS 55444HISS 40471HISS 65141HISS 45172HISS 65242HISS 45273HISS 65343HISS 45374HISS 65444HISS 45471HISS 55172HISS 55273HISS 5537Ø 6.54Ø 5.5Ø 6.5Ø 4.0Ø 4.57Ø 4.01HISS 40152HISS 40253HISS 40354HISS 40454HISS 55471HISS 45151HISS 65172HISS 45252HISS 65273HISS 45353HISS 65374HISS 45454HISS 6547Ø 5.55.5Ø 4.5Ø 6.5

35 IBS Implant Catalog & ManualIBS Prosthetic SystemSolid Abutment Impression Cap Used for precise impression coping on solid abutment[Unit:mm]CodeØ 4.0FSPC40Ø 4.5FSPC45Ø 5.5FSPC55Ø 6.5FSPC65Magic FCØDiameterSolid Abutment Analog Used with Solid Abutment[Unit:mm]ØDiameterØ 4.0Ø 4.5Ø 5.5Ø 545.5FSLA6557FSLA657DHTemporary Abutment Abutment Screw (OIAS400) 3HexNon-Hex

IBS Implant Catalog & Manual36IBS Prosthetic SystemLab Analog Designed to replicate the exact positon and exact externaland internal anatomy of chosen implant for laboratory use.DD[Unit:mm]ØDiameterCodeØ 4.8HIALFC MiniHIALMFC MiniMagic FCSub Hex Impression Coping Used when working cast is fabricated, and has same inner-connection Used with close tray when taking fixture level impression Used with open type tray when taking fixture level impression Tighten by using 1.2 Hexa Driver and Torque Ratchet (10N/cm) Transfer Cap (TCS) included in the packagestructure as the fixtureTransfer TypeØDiameterØ 4.0[Unit:mm]Height(H)Code11.9 (Short)HICTS40S14.9 (Long)HICTS40L11.9 (Short)HICTS50S14.9 (Long)HICTS50LDHØ 5.0Pick-up TypeØDiameterShort[Unit:mm]Height(H)Code11.9 (Short)HICP40S14.9 (Long)HICP40L11.9 (Short)HICP50S14.9 (Long)HICP50LLongDØ 4.0HØ 5.0ShortLong

37 IBS Implant Catalog & ManualIBS Prosthetic SystemScrew-retained Prosthetics:Multi-unit Abutment / CylinderMagic FCClosing ScrewMagic FCMagic ScrewHealing AbutmentMulti-unit Abutment Transfer type Multi-unit AbutmentMulti-unit Abutment Cap Pick-up type Impression CopingMulti-unit Abutment Analog Hex / Non-Hex Hex / Non-Hex Hex / Non-Hex CCM CylinderPlastic CylinderTemporary Cylinder

IBS Implant Catalog & Manual38IBS Prosthetic SystemMulti-unit Abutment Used with multiunit cylinders to create multiple unit restorationsTighten with Multi-unit Abutment Driver (25N 30N/cm)DMulti-unit Abutment MH4820703FMH483080Hex4FMH4840905FMH485100Magic FCImproves posterior angulation in screw retained multiple unit restorationsTighten with 1.2 Hexa driver (25N 30N/cm) Multi-abutment Abutment screw (MUASR) included ADMulti-unit Abutment (Angled)CuffDiameterØ4.817 / 30 Cuff[Unit:mm]17 30 --FMH485113FMN485113

39 IBS Implant Catalog & ManualIBS Prosthetic SystemMulti-unit Abutment Cap Used to protect the abutment in the patients mouth and minimize discomfort for the patientRetaining screw (MASR) includedTighten with 1.2 Hexa Driver and Torque Ratchet c FCMulti-unit Abutment Impression copingPick-up Type [Unit:mm]DiameterHeightØ4.814.8Hex / Non-HexCodeHexMIPH48RNon-HexMIPN48RPick-up type impression-taking process using custom tray (Open tray)Tighten with 1.2 Hexa Driver and Torque Ratchet (10N)Transfer Type HD[Unit:mm]DiameterHeightØ4.814.8Hex / Non-HexCodeHexMITH48RNon-HexMITN48RTransfer type impression taking process using ready-made tray (Closed Tray)Tighten with 1.2 Hexa Driver and Torque Ratchet (10N)HDMulti-unit Abutment Analog Replacement of abutment shape in working castDAnalog[Unit:mm]DiameterCodeØ4.8MAA48R

IBS Implant Catalog & Manual40IBS Prosthetic SystemMulti-unit Abutment CCM CylinderUsed with Multi-unit Abutments to create multiple screw retainedprosthetics. Requires the use of dental alloys with lower melting points.Retaining screw (MASR) includedTighten with 1.2 Hexa Driver and Torque Ratchet (20N)The hex type is compatible with the straight type multi-unit abutment only. CCM Cylinder[Unit:mm]DiameterHeightØ4.812Hex / ic FCMulti-unit Abutment Plastic Cylinder Used with multi-unit abutments to create multiple unit screw retained prostheticsAll plastic design allows for the use of base alloysRetaining screw (MASR) includedTighten with 1.2 Hexa Driver and Torque Ratchet (20N)The hex type is compatible with the straight type multi-unit abutment only.Plastic Cylinder[Unit:mm]DiameterHeightØ4.812Hex / ti-unit Abutment Temporary Cylinder Allow appliances to be constructed or modified to become implant supported and screw retainedRetaining screw (MASR) includedTighten with 1.2 Hexa Driver and Torque Ratchet (20N)The hex type is compatible with the straight type multi-unit abutment only.Temporary Cylinder[Unit:mm]DiameterHeightØ4.812Hex / Non-HexCodeHexMCTH48RNon-HexMCTN48RDHHexNon-Hex

41 IBS Implant Catalog & ManualIBS Prosthetic SystemScrew-retained Prosthetics:UCLA AbutmentDigital RestorationMagic FCMagic FCClosing ScrewMagic ScrewHealing AbutmentCasting Transfer type CAD-CAM Pick-up type Sub Hex Impression CopingScan Body Hex / Non-Hex Hex / Non-Hex CCM UCLAPlastic UCLALab AnalogLink (Ti-base)

IBS Implant Catalog & Manual42IBS Prosthetic SystemMagic FC CAD/CAM Components※ CAD/CAM Components※ Link library available※ Full Zirconia available Abutment Screw (OIAS400) includedMagic FC ScanbodyCodeFSBMagic FCMagic FC Link A AbutmentUsed for construction of screw retained prostheticsRequires the use of dental alloys with lower melting ranges Tighten with 1.2 Hexa driver (25N 30N/cm) Abutment Screw (OIAS400) includedDCCM on-Hex1FUCH 4001FUCN 40015FUCH 4501FUCN 4501Non-HexUsed for construction of screw retained prostheticsAll plastic design allows for the use of base alloys Tighten with 1.2 Hexa driver (25N 30N/cm) DPlastic odeHexNon-Hex1FUPH 4001FUPN 40015FUPH 4501FUPN 4501

Magic FC 31IBS Implant Catalog & Manual IBS Prosthetic System Prevention of foreign substance penetrating into fixture after placement Tighten by using 1.2 Hexa Driver and Torque Ratchet (5N 10N/cm) Forming gingival shape after osseointegration Tighten by using 1.2 Hexa Driver and Torque Ratchet (5N 10N/cm) D Cuff H D [Unit:mm][Unit:mm]Closing Screw