Service InstructionsPACKAGE TERMINALAIR CONDITIONER/HEAT PUMPStandard and Remote Applicationswith LED M70 Control Boardand R-410AThis manual is to be used by qualified, professionally trained HVAC technicians only.Goodman does not assume any responsibility for property damage or personal injurydue to improper service procedures or services performed by an unqualified person.RS4200005r11September 2017is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX, USA. All rights reserved. 2014 - 2017 Goodman Company, L.P.

INDEXPRODUCT IDENTIFICATION . 4IMPORTANT INFORMATION. 2SPECIFICATIONS . 5PROPER INSTALLATION . 9MAINTENANCE . 32OPERATIONS . 34SERVICING . 38WIRING DIAGRAMS . 61IMPORTANT INFORMATIONPride and workmanship go into every product to provide our customers with quality products. It is possible, however,that during its lifetime a product may require service. Products should be serviced only by a qualified servicetechnician who is familiar with the safety procedures required in the repair and who is equipped with the proper tools,parts, testing instruments and the appropriate service manual. REVIEW ALL SERVICE INFORMATION IN THEAPPROPRIATE SERVICE MANUAL BEFORE BEGINNING REPAIRS.IMPORTANT NOTICES FOR CONSUMERS AND SERVICERSRECOGNIZE SAFETY SYMBOLS, WORDS AND LABELSONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL, ADJUST, SERVICE ORREPAIR (HEREINAFTER, “SERVICE”) THE EQUIPMENT SPECIFIED IN THISMANUAL SHOULD SERVICE THE EQUIPMENT. IN ADDITION, IN JURISDICTIONSTHAT REQUIRE ONE OR MORE LICENSES TO SERVICE THE EQUIPMENT SPECIFIEDIN THIS MANUAL, ONLY LICENSED PERSONNEL SHOULD SERVICE THEEQUIPMENT. IMPROPER INSTALLATION, ADJUSTMENT, SERVICING OR REPAIROF THE EQUIPMENT SPECIFIED IN THIS MANUAL, OR ATTEMPTING TO INSTALL,ADJUST , SERVICE OR REPAIR THE EQUIPMENT SPECIFIED IN THIS MANUALWITHOUT PROPER TRAINING MAY RESULT IN PRODUCT DAMAGE, PROPERTYDAMAGE, PERSONAL INJURY OR DEATH.2

WARNINGWARNINGTHIS AIR CONDITIONER IS NOT MEANT TO PROVIDEUNATTENDED COOLING OR LIFE SUPPORT FORPERSONS OR ANIMALS WHO ARE UNABLE TOREACT TO THE FAILURE OF THIS PRODUCT.THE FAILURE OF AN UNATTENDED AIR CONDITIONER MAY RESULT IN EXTREME HEAT IN THE CONDITIONED SPACE CAUSING OVERHEATING ORDEATH OF PERSONS OR ANIMALS.PRECAUTIONS MUST BE TAKEN TO WARN OF ORGUARD AGAINST SUCH AN OCCURENCE.WARNINGGOODMAN WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROMIMPROPER SERVICE OR SERVICE PROCEDURES. IF YOU INSTALL OR PERFORM SERVICE ON THIS UNIT,YOU ASSUME RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY DAMAGE WHICH MAYRESULT. MANY JURISDICTIONS REQUIRE A LICENSE TO INSTALL OR SERVICE HEATING AND AIRCONDITIONING EQUIPMENT.To locate an authorized servicer, please consult your telephone book or the dealerfrom whom you purchased this product. For further assistance, please contact:CONSUMER INFORMATION LINE AMANA BRAND PRODUCTS TOLL FREE1-877-254-4729 (U.S. only)email us at: customerservice@goodmanmfg.comfax us at: (713) 856-1821(Not a technical assistance line for dealers.)Outside the U.S., call 1-713-861-2500.(Not a technical assistance line for dealers.)Your telephone company will bill you for the call.is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX. All rights reserved.3

PRODUCT IDENTIFICATIONPTC07 3 GBASIC MODEL TYPEPTC Standard Cooler PTACPTH Standard Heat Pump PTHPDRY Dehumid Cooler PTACPMC Cooler w/ Makeup Air KitPMH Heat Pump w/ Makeup Air KitHEH High Efficiency Heat Pump HEHPHEC High Efficiency Cooler35 A X X XAAMAJOR/MINOR DESIGN REV.COOLING CAPACITY07 7000 BTUH (60 Hz)09 9000 BTUH (60 Hz)10 10000 BTUH (50 Hz)12 12000 BTUH (50 or 60 Hz)15 15000 BTUH (60 Hz)17 16500 BTUH (60 Hz)RATED VOLTAGE2 115V 60Hz 1Ph3 230/208V 60Hz 1Ph4 265V 60Hz 1Ph5 240/220V 50Hz 1PhDESIGN SERIESE R-410A 2010 RatingsF R-410A California ModelG R-410A 2012 RatingsH R-410A High EER 2012J R-32HEATER SIZE00 no electric heat15 1.5 kW25 2.5 kW35 3.5 kw (230/208V) 3.7kW (265V)50 5.0 kW4FEATURE CODEA Standard ModelC Corrosion Protection (Seacoast)D Power DoorE Makeup Air Electric HeaterF Fuse HolderH HydronicH1 McQuay Hydronic ReplacmentK Added Drain Valve (PTC only)L Lighting ControlN Non-Branded FrontP Condensate PumpQ Quiet STC KitR RF AntennaV Power VentW Hard WiredX place holderY High VA TransformerUse up to 4 as neededIn Alphabetical XXPTC073E35CQVXPTC073E35CDQR

PMC/PMH SERIESSPECIFICATIONSModel ¹, 6, 8, 9PMC073G**PMC093G**PMC123G**PMC153G**230 / 208230 / 208230 / 208230 / 2087,700 / 7,7009,000 / 9,00012,000 / 11,70015,000 / 14,700Amps103.5 / 3.54.1 / 4.15.6 / 5.67.0 / 7.0Watts10655 / 655795 / 7951,150 / 1,1101,575 / 1,530EER11.7 / 11.711.3 / 11.310.4 / 10.59.5 / 3G**PMH153G**230 / 208230 / 208230 / 208230 / 2087,600 / 7,6009,000 / 9,00012,000 / 12,00014,700 / 14,700Amps103.6/3.64.1/4.15.7/5.77.0/7.0Watts10640 / 640795 / 7951150 / 11501,530 / 1,530EER11.8 / 11.811.3 /11.310.4 / 10.49.6 / 9.625-3525-3525-3525-35Kit Dehumidification (Oz/Hr)5555Model ¹, 6, ,000Amps 103.24.35.1Watts ge ¹, ³Capacity (BTU/h)Kit Fresh Air, CFMKit Dehumidification (Oz/Hr)Model ¹, 6, 8, 9Voltage ¹, ³Capacity (BTU/h)Kit Fresh Air, CFM9Voltage ¹, ³Capacity (BTU/h)Kit Fresh Air, CFMKit Dehumidification (Oz/Hr)* A ctual v ent CFM perf ormance w ill vary due to application and ins tallation c onditions.Note s :¹²A ll 265-volt models mus t use an A mana brand sub-base (PTSB4**E) or an A mana brand hard-w ire kit (PTPWHWK4).Minimum Circ uit A mpacity (MCA ) ratings conf orm to the National Electric Code; how ever, local codes s hould apply.Minimum v oltage on 230/208-volt models is 197 volts; maximum is 253 volts.³45Minimum voltage on 265-v olt models is 239 volts; max imum is 292 volts.Overcurrent protection f or all units w ithout electric heaters is 15 amps. Overcurrent protec tion on 265-volt models must be cartridge-s tyle time-delay f uses(included and f actory-installed on all A mana brand 265-volt chassis). See heater perf ormHeating capacity and ef f icienc y based on unit operation w ithout c ondensate pump; unit automatic ally sw itches to electric heat at approx imately 24 F outdoo6Spec if y tw o-digit heater kW s ize to complete model number.7R-410A ref rigerant used in all sys tems. R-134A used in Kit Fresh A ir.8A ll units meet or exc eed A SHRA E 90.1 s tandards.9A ll units less than 250 volts have a Leak Current Detector Interrupter (LCDI) pow er c ord and meet UL 484 standards .10Ref er to elec tric heat perf ormance data f or total MCA and recommended ov ercurrent protection. A mps and Watts notation ref ers to c ompressor only.EER -Energy Efficiency Ratio per The Air-Conditioning,Heating, and Refrigeration Institute (AHRI) TestProcedures and Canadian Standards Association(CSA) Test Procedures.COP -Coefficient of Performance per AHRI TestProcedures5

SPECIFICATIONSPTC G SERIESCOOLING - PTCModelPTC073G**1, 7, 9, 10Voltage ¹, ³Capacity TC123G**PTC153G***PTC154G***230/208265115230 / 208265230/208230 / 2082657700/77007,7009,0009,000 / 9,0009,0001200/1170015,000 / 14,70014,800Amps 113.5/3.53.08.34.1 / 4.13.65.6/5.67.0 / 7.06.1Watts 11655/655655795805 / 7857951150/11101,500 / 1,4701,480EER11.7/11.711.711.311.2 / 11.511.310.4/10.510.0 / **65**65**40*65**65**Unit without Electric HeaterMin. Circuit Amps2, 5, 11CFM (Cool/Wet Coil)CFM (Dry Coil)Ventilated Air, CFM (Fan Only)**Dehumidification (Pints/Hr.)1.71.72.22.22.21.74.44.4Net Weight (lbs.)106103102102102108113113Ship Weight (lbs.)115115117117117125130130* Information in this manual applies only to the BA revision of 092G*** model.** Actual vent CFM performance w ill vary due to application and installation conditions.Notes:¹All 265-volt models must use an Amana brand sub-base (PTSB4**E) or an Amana brand hard-w ire kit (PTPWHWK4).²Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; how ever, local codes should apply.Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.3456Minimum voltage on 265-volt models is 239 volts; maximum is 292 volts.Minimum voltage on 115-volt models is 104 volts; maximum is 127 volts.Overcurrent protection for all units w ithout electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay fuses(included and factory-installed on all Amana brand 265-volt chassis). See heater performHeating capacity and efficiency based on unit operation w ithout condensate pump; unit automatically sw itches to electric heat at approximately 24 F outdoor a7Specify tw o-digit heater kW size to complete model number.8R-410A refrigerant used in all systems.9All units meet or exceed ASHRAE 90.1 standards.10All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) pow er cord and meet UL 484 standards.11Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.EER -Energy Efficiency Ratio per The Air-Conditioning,Heating, and Refrigeration Institute (AHRI) TestProcedures and Canadian Standards Association(CSA) Test Procedures.COP -Coefficient of Performance per AHRI TestProcedures6

SPECIFICATIONSPTC G SERIESCOOLING - PTCM ode l1, 7, 9, 10V oltage ¹, ³C apac ity (B TU /h)A m ps 1 1W atts11EERPTC073G **D APTC093G ***D APTC123G **D A230/208230 / 208230/2087000/70009,200 / 9,00011500/114003.1/3.14.1 / 4.15.0/5.0580/560790/7651045/101512/12.511.6 / 11.711.0/11.0U n it w ith o u t Ele ctric H e a te r2, 5, 113.75.06.2H igh330290340Low245264245H igh360310370Low270282270V entilated A ir, C F M (F an O nly )**40*65**40*D ehum idific ation (P ints /H r.)1.72.21.7N et W eight (lbs .)106108110S hip W eight (lbs .)115119126M in. C irc uit A m psC F M (C ool/W et C oil)C F M (D ry C oil)** Actual vent CFM performance w ill vary due to application and installation conditions.Notes:¹All 265-volt models must use an Amana brand sub-base (PTSB4**E) or an Amana brand hard-w ire kit (PTPWHWK4).²Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; how ever, local codes should apply.Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.3456Minimum voltage on 265-volt models is 239 volts; maximum is 292 volts.Minimum voltage on 115-volt models is 104 volts; maximum is 127 volts.Overcurrent protection for all units w ithout electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay fuses(included and factory-installed on all Amana brand 265-volt chassis). See heater performHeating capacity and efficiency based on unit operation w ithout condensate pump; unit automatically sw itches to electric heat at approximately 24 F outdoor a7Specify tw o-digit heater kW size to complete model number.8R-410A refrigerant used in all systems.9All units meet or exceed ASHRAE 90.1 standards.10All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) pow er cord and meet UL 484 standards.11Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.EER -Energy Efficiency Ratio per The Air-Conditioning,Heating, and Refrigeration Institute (AHRI) TestProcedures and Canadian Standards Association(CSA) Test Procedures.COP -Coefficient of Performance per AHRI TestProcedures7

HEC H SERIESSPECIFICATIONSCOOLING - HECM ode lH EC073H **1, 7, 9, 10V oltage ¹, ³H EC093H ***H EC123H **230/208230 / 208230/2087000/70009,200 / 9,00011600/11400A m ps 1 13.5/3.54.5 / 4.55.4/5.4W atts 1 1555/535770/7501025/990EER12.6/1311.9 / 1211.3/11.54.25.46.6H igh330290340Low245264245H igh360310370Low27028227040*65**40*C apac ity (B TU /h)U n it w ith o u t Ele ctric H e a te rM in. C irc uit A m ps2, 5, 11C F M (C ool/W et C oil)C F M (D ry C oil)V entilated A ir, C F M (F an O nly )**D ehum idific ation (P ints /H r.)1.72.21.7N et W eight (lbs .)106108110S hip W eight (lbs .)115119126** Actual vent CFM performance w ill vary due to application and installation conditions.Notes:¹All 265-volt models must use an Amana brand sub-base (PTSB4**E) or an Amana brand hard-w ire kit (PTPWHWK4).²Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; how ever, local codes should apply.Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.3456Minimum voltage on 265-volt models is 239 volts; maximum is 292 volts.Minimum voltage on 115-volt models is 104 volts; maximum is 127 volts.Overcurrent protection for all units w ithout electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay fuses(included and factory-installed on all Amana brand 265-volt chass

F R-410A California Model H1 McQuay Hydronic Replacment G R-410A 2012 Ratings K Added Drain Valve (PTC only) H R-410A High EER 2012 L Lighting Control J R-32 N Non-Branded Front P Condensate Pump Q Quiet STC Kit HEATER SIZE R RF Antenna 00 no electric heat V Power Vent 15 1.5 kW W Hard Wired 25 2.5 kW X place holder 35 3.5 kw (230/208V) Y