VASCULAR ACCESS - Nipro Group

Transcription

RENAL CAREVASCULARACCESSBECAUSE EVERY LIFEDESERVES AFFORDABLE CARE

INDEXCONTENTSSTANDARD, 2-PACK, SINGLE NEEDLE. 4CATHETER NEEDLES. 6SAFETOUCH AVF NEEDLE. 10SAFETOUCH TULIP . 12AVF SAFETOUCH CATHETER NEEDLE, AVF SAFETOUCH SINGLE NEEDLE CATHETER NEEDLE. 14BIOHOLE NEEDLE, BIOHOLE SINGLE NEEDLE. 18BIOHOLE SAFETOUCH TULIP . 20BIOHOLE CATHETER NEEDLE. 22BIOHOLE BUTTONHOLE DEVICE. 24BIOHOLE SCAB REMOVER. 25ON-OFF KIT. 26PUSHBAN . 27SAFE DERM. 28SAFE FIX IV / IVN. 29D.MED NEPHROFLOW . 302

Because Vascular Access is the gateway toquality of life, Nipro is dedicated to providing thebest possible care to every vascular access.Given that the arteriovenous fistula (AVF) is the method of choice for vascular access1, special care shouldbe taken to ensure its survival. Among others, the following needle specifications for the prevention ofvascular access complications are suggested:1 First few cannulations of a new fistula should be performed with a 17 G needle1,2,4. At a later stage, theneedle gauge may be adapted to the patient’s blood flow. Lower needle gauge can withstand higherblood flow rate.2Recommended needle gaugeBlood flow rate17161514 300 ml/min300-350 ml/min350-450 ml/min 450 ml/minColor Needle length adapted to any fistula depth. Turnable wings to improve the needle positioning. Back eye on arterial needle to optimize the blood flow and minimize the risk of aspiration to thevessel wall.²In order to meet individual patient requirements, Nipro offers a wide range of arteriovenous fistula needlesand arteriovenous catheter needles with lengths from 20 to 38 mm and gauges from 14 G to 17 G dependingon the desired specifications.3

REGULAR NEEDLES DEHP-FREE L AT E X- F R E E G A M M A S T E R I L I Z AT I O NSTANDARD, 2-PACK, SINGLE NEEDLEO U T S TA N D I N G Q U A L I T Y A N D P E R F O R M A N C E F R O M Y E A R S O F E X P E R I E N C E A N D R I G I DM A N U FA C T U R I N G C O N T R O LULTRA SHARP AND SILICONIZED3-BEVEL NEEDLEOVAL-SHAPED BACK-EYEEnsures smooth and optimal puncture andprevents vessel traumaOptimizes blood flow and minimizes the risk of aspirationto the vessel wall on the arterial needleULTRA-THIN NEEDLE WALLGuarantees an optimal blood flowBLACK AND RED DOTSIndicates the bevel position on theneedle with turnable wingsTURNABLE OR FIXEDCOLOR-CODED WINGSFacilitates the recognition ofgauge sizeTEXTURED WINGSProvides secure grip duringneedle manipulationSOFT FLEXIBLE TUBINGEases clamping during the bloodlineconnection/disconnection whileabsorbing shocks and reducingneedle movement in patientCOLOR-CODED OCCLUSION CLAMPAND LUERSimplifies the distinction between arterialand venous needlesTAPERED LUERWarrants a safe and easyconnection/disconnection withbloodlines4S TA N D A R D, 2 - PA C K

STANDARD, 2-PACK, AND SINGLE NEEDLE ADVANTAGES Easy to handle AVF needles Smooth cannulation with ultra sharp needle Optimal blood flowSPECIFICATIONSStandard Needles2-Pack NeedlesSingle NeedlesArterial Needle*Venous Needle*1 Arterial Needle* 1 Venous 20-HTC-30R-GT GTSGN1420-HTC-30RB-GT1420300AV-1425-HTC-30R-GT GTSGN1425-HTC-30RB-GT1425300AV-1432-HTC-30R-GT C-15RB-GT1532150AV-1520-HTC-30R-GT RB-GT1625150AV-1632-HTC-15R-GT2 Arterials Needles*SGN*Size Needle Length Tube Length -1620-HTC-30R-GT T1732150AV-1720-HTC-30R-GT 2-HTC-30RB-GT1732300* Needles with turnable wings. Arterial and venous needles are also available with fixed wings instead of turnable wings. Please contact your local office for otherspecifications, order quantities, and availability.SINGLE NEEDLE5

REGULAR NEEDLES L AT E X- F R E E G A M M A S T E R I L I Z AT I O NCATHETER NEEDLESF O R A C O M F O R TA B L E A N D F L E X I B L E T R E AT M E N TULTRA SHARP AND SILICONIZED3-BEVEL NEEDLEEnsures smooth and optimal puncture andprevents vessel traumaSIDE HOLESOptimizes blood flow and minimizesthe risk of aspiration to the vessel wallULTRA-THIN CATHETER WALLGuarantees an optimal blood flowCOLOR-CODED HUBFacilitates the recognition ofgauge sizeSOFT FLEXIBLE TUBINGEases the clamping during the bloodlineconnection/disconnectionTAPERED LUERWarrants a safe and easyconnection/disconnectionwith bloodlines6

CATHETER NEEDLE ADVANTAGES Plastic fistula needles may prevent vascular access complications1 Safe cannulation during fistula maturation1 Decreased risk of perforation1 Greater patient mobility Better option for patients allergic to metalSPECIFICATIONSAVF Catheter NeedleSize(Gauge)CatheterLength 8ColorPlease contact your local office for other specifications,order quantities, and availability.7

SAFETY NEEDLESTHE FUNDAMENTAL PROTECTION AGAINSTNEEDLESTICK INJURIES (NSI)Every year, healthcare professionals are affected by needlestick and sharps injuries. The World HealthOrganization estimates that 3 of the 35 million healthcare professionals worldwide are exposed tobloodborne pathogens each year as a result of these injuries.3Almost 50% of injuries are not reported, which leads to a significant under-estimation.48

Since 1 in 5 patients in dialysis centers globally are considered “at risk”for HIVand Hepatitis B and C, NSI are a major occupational hazard for both healthcareprofessionals and hospitals.5EXTRA PRESSURE ON HEALTHCARE PROFESSIONALS After a NSI and before contamination is confirmed or denied:— Stress and decreased productivity For those who contract a disease as a result of their injury:— Lifelong consequences— Physical and emotional adjustment— Financial burdens— Inability to continue working in the healthcare profession in some casesADDITIONAL BURDENS FOR HOSPITALS Costs for testing viral contamination, compensation, and leave of absence Loss of professional knowledge and time spent training new personsNSI may be prevented by the use of medical devices that incorporate “safetyengineered protection mechanisms” and the elimination of the unnecessary use ofsharps devices. The recommendations of Clinical Guidelines for the prevention ofcontamination are as follow:6 The safety mechanism must be an integral part of the safety device, not a separate accessory The activation of the safety mechanism must be convenient and allow the care giver to maintainappropriate control over the procedure A single-handed or automatic activation is preferable The activation of the safety mechanism must manifest itself by means of an audible, tactile, or visualsign to the health professional The safety mechanisms should not be easily reversible once activated9

SAFETY NEEDLES DEHP-FREE L AT E X- F R E E G A M M A S T E R I L I Z AT I O NSAFETOUCH AVF NEEDLEF O R A S A F E A N D S U C C E S S F U L T R E AT M E N TOVAL-SHAPED BACK-EYEULTRA SHARP AND SILICONIZED3-BEVEL NEEDLEEnsures smooth and optimal puncture andprevents vessel traumaBLACK AND RED DOTSOptimizes blood flow and minimizesthe risk of aspiration to the vessel wallon the arterial needleULTRA-THIN NEEDLE WALLGuarantees an optimal blood flowIndicates the bevel position on theneedle with turnable wingsTURNABLE OR FIXEDCOLOR-CODED WINGSFacilitates the recognition ofgauge sizeTEXTURED WINGSProvides secure grip duringneedle manipulationSAFETOUCH SAFETYMECHANISMPrevents NSISOFT FLEXIBLE TUBINGEases clamping during the bloodlineconnection/disconnection whileabsorbing shocks and reducingneedle movement in patientTAPERED LUERWarrants a safe and easyconnection/disconnectionwith bloodlines10COLOR-CODED OCCLUSIONCLAMP AND LUEREases the distinction betweenarterial and venous needles

SAFETOUCH AVF NEEDLE FEATURES Reduced risk of needle stick injury Non-reversible mechanism Active safety feature using a one-handed technique Secured locking confirmed by an audible and tactile click Unique locking mechanismSAFETOUCH AVF NEEDLE SAFETY MECHANISM Hold down the wing protector and/or the wings with one hand With the other hand, release the lock by pressing in both sides of the stopper Slide the stopper forward until it becomes completely locked with an audible or tactile clickSPECIFICATIONSSize Needle Length(Gauge)(mm)Tube Length(mm)Arterial Needle*Venous 0RGT AVSF1420-TC-30B-GT1420300AVSF1425-HTC-30RGT AVSF1425-TC-30B-GT1425300AVSF1432-HTC-30RGT 2150AVSF1520-HTC-30RGT AVSF1520-TC-30B-GT1520300AVSF1525-HTC-30RGT AVSF1525-TC-30B-GT1525300AVSF1532-HTC-30RGT 2150AVSF1620-HTC-30RGT AVSF1620-TC-30B-GT1620300AVSF1625-HTC-30RGT AVSF1625-TC-30B-GT1625300AVSF1632-HTC-30RGT 2150AVSF1720-HTC-30RGT AVSF1720-TC-30B-GT1720300AVSF1725-HTC-30RGT AVSF1732-TC-30B-GTColorAVF PROTECTOR* Needles with turnable wings. Arterial and venous needles are also available with fixed wingsinstead of turnable wings. Please contact your local office for other specifications, orderquantities, and availability.STOPPER11

SAFETY NEEDLES DEHP-FREE L AT E X- F R E E G A M M A S T E R I L I Z AT I O NSAFETOUCH TULIP ERGONOMIC PROTECTIONOVAL-SHAPED BACK-EYEULTRA SHARP AND SILICONIZED3-BEVEL NEEDLEOptimizes blood flow and minimizesthe risk of aspiration to the vessel wallon the arterial needleULTRA-THIN NEEDLE WALLEnsures smooth and optimal puncture andprevents vessel traumaGuarantees an optimal blood flowTAPERED LUERWarrants a safe and easyconnection/disconnectionwith bloodlinesBLACK AND RED DOTSIndicates the bevel position on theneedle with turnable wingsTURNABLE OR FIXEDCOLOR-CODED WINGSFacilitates the recognition ofgauge sizeTULIP SAFETY MECHANISMPrevents NSISOFT FLEXIBLE TUBINGEases clamping during the bloodlineconnection/disconnection whileabsorbing shocks and reducing needlemovement in patient12TEXTURED WINGSProvides securegrip during needlemanipulationCOLOR-CODED OCCLUSIONCLAMP AND LUEREases the distinction betweenarterial and venous needles

SAFETOUCH TULIP FEATURES Reduced risk of needle stick injury Non-reversible mechanism Active safety feature using a one-handed technique Secured locking confirmed by a tactile click Unique patented locking mechanism*SAFETOUCH TULIP SAFETY MECHANISM Hold down the wing protector and/or the wings with one hand With the other hand, slide the TULIP needle protector forward until two petals of the TULIP needleprotector tip are positioned over the flattened wings Grasp the tubing at the base of the TULIP needle protector Pull on the tubing while pushing the TULIP needle protector forward, completely covering the needle untilwings are secured in the TULIP needle protector with a tactile clickSPECIFICATIONSArterial Needle**Venous Needle*Size Needle Length(Gauge)(mm)Tube Length(mm)AVT-1420-HTC-30R-GT AVT-1420-TC-30B-GT1420300AVT-1425-HTC-30R-GT AVT-1425-TC-30B-GT1425300AVT-1432-HTC-30R-GT AVT-1432-TC-30B-GT1432300AVT-1520-HTC-30R-GT AVT-1520-TC-30B-GT1520300AVT-1525-HTC-30R-GT AVT-1525-TC-30B-GT1525300AVT-1532-HTC-30R-GT AVT-1532-TC-30B-GT1532300AVT-1620-HTC-30R-GT AVT-1620-TC-30B-GT1620300AVT-1625-HTC-30R-GT AVT-1625-TC-30B-GT1625300AVT-1632-HTC-30R-GT AVT-1632-TC-30B-GT1632300AVT-1720-HTC-30R-GT AVT-1720-TC-30B-GT1720300AVT-1725-HTC-30R-GT AVT-1725-TC-30B-GT1725300AVT-1732-HTC-30R-GT AVT-1732-TC-30B-GT1732300Color** Needles with turnable wings. Arterial and venous needles are also available with fixedwings instead of turnable wings. Please contact your local office for other specifications, orderquantities, and availability.* Patent active in Germany, France, United Kingdom, Italy, and Spain13

SAFETY NEEDLES L AT E X- F R E E G A M M A S T E R I L I Z AT I O NAVF SAFETOUCH CATHETER NEEDLE,AVF SAFETOUCH SINGLE NEEDLE CATHETER NEEDLES A F E A N D E A S Y M A N I P U L AT I O N T O I N C R E A S E PAT I E N T C O M F O R TSIDE HOLES ON PLASTIC TUBEOptimizes blood flow and minimizes therisk of aspiration to the vessel wallULTRA SHARP AND SILICONIZED3-BEVEL NEEDLEEnsures smooth and optimal puncture andprevents vessel traumaULTRA-THIN CATHETER WALLGuarantees an optimal blood flowCOLOR-CODED HUBFacilitates the recognition ofgauge sizeSOFT FLEXIBLE TUBINGEases the clamping during thebloodline connectionTAPERED LUERWarrants a safe and easyconnection/disconnectionwith bloodlinesSAFETOUCH SAFETY MECHANISMPrevents NSIVISIBLE AND TACTILE MARKIndicates the bevel position14AV F S A F E T O U C H C AT H E T E R N E E D L E

SAFETOUCH CATHETER NEEDLE ADVANTAGES Plastic fistula needles may prevent vascular access complications1 Reduced risk of needle stick injury Safe cannulation during fistula maturation1 Decreased risk of perforation1 Greater patient mobility Better option for patients allergic to metalSAFETOUCH CATHETER NEEDLE, SAFETOUCH SINGLE NEEDLECATHETER NEEDLE FEATURES Passive safety device Pre-removal activation: immediate shielding of needle upon withdrawal from catheter Non-reversible mechanism Unique patented locking mechanismSPECIFICATIONSAVF SAFETOUCH CATHETER NEEDLESize(Gauge)CatheterLength (mm)AV-SF-CATH GJ1432AV-SF-CATH-1438-GJ1438AV- SF-CATH-1525-GJ1525AV- SF-CATH-1532-GJ1532AV- SF-CATH-1538-GJ1538AV- SF-CATH-1625-GJ1625AV- SF-CATH-1632-GJ1632AV- SF-CATH-1638-GJ1638AV- SF-CATH-1725-GJ1725AV- SF-CATH-1732-GJ1732AV- SF-CATH-1738-GJ1738CatheterColorPlease contact your local office for other specifications,order quantities, and availability.AVF SAFETOUCH AVF SINGLENEEDLE CATHETER NEEDLECatheterSize(Gauge)CatheterLength TH-1625-GJ1625SGNSF-CATH-1632-GJ1632ColorPlease contact your local office for other specifications,order quantities, and availability.AV F S A F E T O U C H S I N G L E N E E D L E C AT H E T E R N E E D L E15

BIOHOLE NEEDLESBUTTONHOLE TECHNIQUE: THE ULTIMATECOMBINATION OF SAFETY AND COMFORTExperience how the buttonhole technique can help you maximize patient comfort,provide a better experience for your medical staff, and improve your center’sefficiency.Clinical Practice Guidelines recommend different procedures for the prevention of vascularaccess complications, including the use of the buttonhole technique:2, 7 Reduces pain Reduces aneurysms Lowers vascular access failure Facilitates access for self-cannulation Improves appearance of the fistula16

OPTIMIZED PATIENT COMFORT Reduces pain compared to rope-ladder technique 8-12 Minimizes potential needling error and hematoma formation 11, 13, 14 Increases freedom for home dialysis patients, as they can self-cannulate Esthetical aspect: reduces aneurysma formation and only 2 puncture sites 11 Decreases bleeding time 5, 15, 16 Diminishes tunnel track deformation Reduces penetration forceIMPROVED OPERATIONAL EFFICIENCY Extends life of the vascular access 8 Decreases amount of needle attempts 9, 17 Reduces workload: shorter bleeding time, prevents rebleeding, avoids hematoma and linkedcomplications 5, 10, 15, 16SHARP NEEDLEDULL NEEDLEFor standard cannulation techniques and firstcannulation(s) for the buttonhole techniqueFor the buttonhole technique17

BIOHOLE NEEDLES DEHP-FREE L AT E X- F R E E G A M M A S T E R I L I Z AT I O NBIOHOLE NEEDLE, BIOHOLE SINGLE NEEDLER E D U C E D PA I N D U R I N G A R T E R I O V E N O U S I N S E R T I O NOVAL-SHAPED BACK-EYEOptimizes blood flow and minimizes the risk ofaspiration to the vessel wall on the arterial needleSILICONIZED DULL NEEDLEEnsures smooth penetration andprevents vessel traumaULTRA-THIN NEEDLE WALLGuarantees an optimal blood flowTURNABLE OR FIXEDCOLOR-CODED WINGSFacilitates the recognition ofgauge sizeBLACK AND RED DOTSIndicates the bevel position onthe needle with turnable wingsSOFT FLEXIBLE TUBINGEases clamping during the bloodlineconnection/disconnection whileabsorbing shocks and reducing needlemovement in patientTEXTURED WINGSProvides secure grip duringneedle manipulationWHITE OCCLUSION CLAMPSCAB REMOVERAllows easy distinction betweenstandard and safety needlesSimplifies the scab removal whenusing the buttonhole techniqueTAPERED LUERCOLOR CODED LUERWarrants a safe and easyconnection/disconnectionwith bloodlines18Eases the distinction betweenarterial and venous needlesBIOHOLE NEEDLE

BIOHOLE AND BIOHOLE SINGLE NEEDLE ADVANTAGES Specially designed to be used with the buttonhole technique Easy to handle BioHole needle Optimal blood flowSPECIFICATIONSSize Needle Length Tube Length Color(Gauge)(mm)(mm)Arterial Needle*Venous Needle*Single 30R-GTAVD1732-TC-30B-GTSGD1732-HTC-30RBGT1732300* Needles with turnable wings. Arterial and venous needles are also available with fixed wings instead of turnable wings.Please contact your local office for other specifications, order quantities, and availability.BIOHOLE NEEDLESform the perfect combination withthe BioHole Buttonhole DeviceBIOHOLE SINGLE NEEDLE19

BIOHOLE NEEDLES DEHP-FREE L AT E X- F R E E G A M M A S T E R I L I Z AT I O NBIOHOLE SAFETOUCH TULIP R E D U C E D PA I N D U R I N G A R T E R I O V E N O U S I N S E R T I O N W H I L E E N S U R I N G S A F E T Y F O R A L LOVAL-SHAPED BACK-EYEOptimizes blood flow and minimizesthe risk of aspiration to the vessel wallon the arterial needleSILICONIZED DULL NEEDLEEnsures smooth penetration andprevents vessel traumaULTRA-THIN NEEDLE WALLGuarantees an optimal blood flowTAPERED LUERWarrants a safe and easyconnection/disconnectionwith bloodlinesBLACK AND RED DOTSIndicates the bevel position on theneedle with turnable wingsTURNABLE OR FIXEDCOLOR-CODED WINGSFacilitates the recognition ofgauge sizeTEXTURED WINGSProvides securegrip during needlemanipulationCOLOR-CODED OCCLUSIONCLAMP AND LUERSCAB REMOVERSimplifies the scab removal whenusing the buttonhole techniqueSOFT FLEXIBLE TUBINGEases clamping during the bloodlineconnection/disconnection whileabsorbing shocks and reducing needlemovement in patient20TULIP SAFETYMECHANISMPrevents NSIEases the distinction betweenarterial and venous needles

BIOHOLE SAFETOUCH TULIP NEEDLE FEATURES Specially designed to be used with the buttonhole technique Easy to handle Optimal blood flow Reduced risk of needle stick injury Non-reversible mechanism Active safety feature using a one-handed technique Secured locking confirmed by a tactile click*BIOHOLE SAFETOUCH TULIP SAFETY MECHANISM Hold down the wing protector and/or the wings with one hand With the other hand, slide the TULIP needle protector forward until two petals of the TULIP needleprotector tip are positioned over the flattened wings Grasp the tubing at the base of the TULIP needle protector Pull on the tubing while pushing the TULIP needle protector forward, completely covering the needle untilwings are secured in the TULIP needle protector with a tactile clickSPECIFICATIONSArterial Needle**Venous Needle**Size Needle Length(Gauge)(mm)Tube Length(mm)AVDT1425-HTC-30RGT AVDT1425-TC-30BGT1425300AVDT1432-HTC-30RGT AVDT1432-TC-30BGT1432300AVDT1525-HTC-30RGT AVDT1525-TC-30BGT1525300AVDT1532-HTC-30RGT AVDT1532-TC-30BGT1532300AVDT1625-HTC-30RGT AVDT1625-TC-30BGT1625300AVDT1632-HTC-30RGT AVDT1632-TC-30BGT1632300AVDT1725-HTC-30RGT AVDT1725-TC-30BGT1725300AVDT1732-HTC-30RGT AVDT1732-TC-30BGT1732300Color** Needles with turnable wings. Arterial and venous needles are also available with fixedwings instead of turnable wings. Please contact your local office for other specifications, orderquantities, and availability.BIOHOLE NEEDLESform the perfect combination withthe BioHole Buttonhole Device* Patent active in Germany, France, United Kingdom, Italy, and Spain21

BIOHOLE NEEDLES L AT E X- F R E E G A M M A S T E R I L I Z AT I O NBIOHOLE CATHETER NEEDLER E D U C E D PA I N A N D I N C R E A S E D C O M F O R T D U R I N G A R T E R I O V E N O U S I N S E R T I O NSILICONIZED DULL NEEDLEEnsures smooth penetration andprevents vessel traumaSIDE HOLESOptimizes blood flow andminimizes the risk of aspirationto the vessel wallULTRA-THIN CATHETER WALLGuarantees a nearly painless catheterinsertion and optimal blood flowCOLOR-CODED HUBFacilitates the recognition ofgauge sizeSOFT FLEXIBLE TUBINGEases the clamping during thebloodline connection/disconnectionTAPERED LUERWarrants a safe and easyconnection/disconnection withbloodlines22

BIOHOLE CATHETER NEEDLE ADVANTAGES Plastic fistula needles may prevent vascular access complications 1 Safe cannulation during fistula maturation 1 Decreased risk of perforation 1 Greater patient mobility Better option for patients allergic to metalSPECIFICATIONSSize(Gauge)CatheterLength GJ1738Catheter NeedleColorPlease contact your local office for other specifications,order quantities, and availability.BIOHOLE CATHETER NEEDLESform the perfect combination with the BioHoleButtonhole Device and the individual BioHolescab remover23

ACCESSORIES DEHP-FREE L AT E X- F R E E G A M M A S T E R I L I Z AT I O NBIOHOLE BUTTONHOLE DEVICEFA S T E R T U N N E L T R A C K C R E AT I O N F O R T H E B U T T O N H O L E T E C H N I Q U EThe BioHole buttonhole device is effective in the creation of tunnel tracks for the buttonhole technique.The BioHole stick is inserted into the needle track toward the access vessel, along the same path as thepuncture needle that was just previously removed.BIOHOLE STICK IS COMFORTABLE FOR PATIENTS Reduced number of cannulations with a sharp needle leads to less tunnel deformation and fewercomplications 8, 18 Minimized pain by using the BioHole stick to establish the tunnel Reduced tunnel formation time from 2-3 months to 14 days 8, 18 Extended range of BioHole stick lengthsBIOHOLE STICK PROVIDES BENEFITS TO MEDICAL STAFF Simplified access creation, as early as the second session Limited use of sharp needles Accelerated method to create a buttonhole tunnel track 8, 18 3 stick lengths to better meet patient needsSPECIFICATIONSArticle 88Please contact your local office for order quantities and availability.Three different stick lengths:3 mm, 5 mm and 8 mmPolypropylene holder24Thumbtack-shapedpolycarbonate stick

ACCESSORIES DEHP-FREE L AT E X- F R E E G A M M A S T E R I L I Z AT I O NBIOHOLE SCAB REMOVERSAFE AND E A SY TOOL TO REMOVE THE SCAB FOR THE BUT TONHOLE TECHNIQUEThe BioHole scab remover is intended to be used with the buttonhole technique to remove the scab formedat the entrance of the tunnel tracks.BIOHOLE SCAB REMOVER FEATURES Excellent grip Included with the BioHole needles or available as a separate unit in an individual sterile packageSPECIFICATIONSArticle CodeSCAB-REMOVER-GTPlease contact your local office for order quantities and availability.25

ACCESSORIESON-OFF KITC O N N E C T I O N - D I S C O N N E C T I O N K I T F O R H E M O D I A LY S I SON-OFF KIT FEATURES ON-OFF kits are available in various configurations, suitable for fistula and catheter treatments Kits facilitate the start and end of dialysis sessions for nurses Kits can be customized on requestSPECIFICATIONS26Article CodeON kitOFF kitOO-AVF-1-EC(4) sterile gauze (5x5 cm)(2) sterile gauze (10x10 cm)(2) microporous strips (1,25x15 cm)(2) latex exam gloves (M)(1) PE drape (38x43 cm)(4) sterile gauze (5x5 cm)(1) latex exam glove (M)(2) Medispo bandage (30x72 mm)(1) PE drape (38x43 cm)OO-CAT-1-EC(4) sterile gauze (5x5 cm)(2) sterile gauze (10x10 cm)(2) latex exam glove (M)(1) PE drape (38x43 cm)(4) sterile gauze (5x5 cm)(2) latex exam glove (M)(1) PE drape (38x43 cm)(1) sterile gauze (10x10 cm)OO-EASY-F-ETR(2) Nitrile Gloves (M)(4) Nonwoven swab (7,5x7,5 cm)(1) Dressing (8x10 cm)(1) Operation Drape (wrapped) (30x40 cm)(2) Nitrile Gloves (M)(4) N

Because Vascular Access is the gateway to quality of life, Nipro is dedicated to providing the best possible care to every vascular access. Given that the arteriovenous fistula (AVF) is the method of choice for vascular access 1, special care should be taken to ensure its survival.