Hi-Performance Fan Coils400 - 2,200 CFM

Table of ContentsAirtherm Fan Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Hi-Performance Vertical Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Features & Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Equipment Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6ARI Cooling Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Heating Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Coil Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Electric Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Air Flow Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Motor Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Sound Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Weights & Measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21ARI CertifiedAirtherm Hi-Performance fan coils are labeled and approved by the Air Conditioningand Refrigeration Institute (ARI). This designation signifies that Airtherm SuperiorPerformance fan coil units have been examined by ARI and comply with the organization’sapplicable standards.UL ListingAirtherm Hi-Performance fan coils are listed by Underwriters Laboratories, Inc. (UL).The UL listing ensures that Airtherm Hi-Performance fan coil units have been examinedby UL and comply with the organization’s applicable standards. UL’s re-examinationservice includes periodic visits by UL inspectors to Airtherms’ factory to ensure continued compliance for all listed products.RCRLISTEDUSC-UL US ListingHi-P(ULC). The C-UL US listing ensures that Airtherm Hi-Performance fan coil units havebeen examined by UL and are in compliance with both the U.S. and Canadian organizations’ applicable standards.Materials and equipment acceptance for use by the New York Departmentof Buildings:SV004-008, SV006-022SV004-022 Hi-PerformanceFan CoilsMEA 411-05-EMEA 409-05-E

F an Coils and Air HandlersApplied Products.more than just fan coils.For 90 years, Airtherm has been a marketleader in providing high quality HVACproducts for residential and commercialbuildings. Today, the AppliedProductsGroupcontinuesthe proudtraditionby offering to the commercial/industrial marketmore configurations and size options ofquality fan coils and blower coils/air handlers than any other HVAC company inNorth America.The Applied Products Group,based in Oklahoma City, Oklahoma, servesall US and overseas markets with completeapplication engineering, sales, marketing andadministrative services.Served by company factories in Colton,California and Phoenix, Arizona, the Applied Products Group uses the resourcesof nearly 600,000 square feet of manufacturing and warehouse facilities to providehigh quality products to some of the mostdiscriminating customers in the world.The Applied Products Grouppledge is toprovide complete, highquality andtimely supportfor the successful completion of your construction projects involving engineered products offeredby Airtherm. We believe in a partneringattitude that creates superior projects andhigh levels of satisfaction.3

Hi-Performance Vertical Models - SV Series400 - 2200 CFMSVTB - Vertical BasicSVTBThe Vertical Basic (SVTB) is a high static, ducted vertical casedfan coil with bottom return. Primarily used in vertical floormounted or hideaway applications, the Vertical Basic is furredinto partition walls or hidden in closets, utility rooms and otherconcealed locations with a ducted discharge. A removable frontaccess panel facilitates easy servicing. A one-inch discharge ductflange is standard on the top panel of each unit. Front ReturnBasic also available.SDTB - Vertical DeluxeThe Vertical Deluxe (SDTB) is our Basic model primarily usedin floor-mounted or exposed applications. The Vertical Deluxeis finished in a soft white, powder coat epoxy and subjected to a1500-hour salt spray test in accordance with ASTM B117. FrontReturn Deluxe is also available.SDTBSCTF - Vertical Front ReturnThe Vertical Front Return (SCTF) is a high static, ducted verticalfan coil for installation in a closet-type enclosure. The front panelis removable for easy service access to the slide-out blower assembly, with quick-connect plug. Vertical Front Return with return-airgrille option allows unit to be furred-in. Grille mounts to drywallfor easy access without the expense of a closet door. VerticalFront Return Deluxe also available.SCTF4

Features and BenefitsStandard Features Heavy-gauge galvanized steel cabinet withneoprene-coated 1/2” thick fiberglass insulation with3.35 PCF density. Coils are made of 1/2” OD copper tube withaluminum fins (12 FPI) equipped with manual-airvent. DX and steam coils do not include manual-airvent. Coils are 100% underwater pressure tested at350 PSI with a 300 PSI working pressure. Galvanized drain pan is powder-coated epoxy andsubjected to a 650-hour salt spray test in accordancewith ASTM-B117. Also comes with 1/8” thickclosed-cell insulation and primary and secondarydrain connections. Three-speed, 115/1/60 PSC motor withquick-connect plug. Controls and motors are factory-wired andterminated in a junction box for single-pointpower supply. One-inch, reinforced duct collar on return- andsupply-air openings. Swing-down, hinged return-air grille/access dooron Deluxe and Flush models. Deluxe unit has single-deflection supply-air grille. One-inch fiberglass, throwaway filter, exceptHorizontal Basic. Individually tagged, crated and shipped asscheduled for installation. UL and C-UL approved, ARI certified and100% factory tested.5 Hi-PerformanceFan Coils

Equipment OptionsOptions Soft-white, powder-coated epoxy cabinet that’ssubjected to a 1500-hour salt spray test in accordancewith ASTM-B117. Drain Pans - stainless steel. Insulation - fiberglass, foil-face, elastomericand double-wall (solid or perforated) in 1/2” and1” thicknesses. Coils - copper fins/tubes, stainless steel fins/tubes,phenolic coated, stainless steel end plates. Alloptions are available on one- to six-rows. Three-speed, 208-230/1/50-60 or 277/1/60 PSCmotor with quick-connect plug. Systems - two- or four-pipe, hydronic cooling/heating, steam, direct-expansion (DX) and/orelectric heat. Cabinet - Deluxe, Flush and custom colors. Controls - wide selection of factory-mountedvalves and controls. Filters - two-inch thick throwaway, washable and metallic. Flow-control circulator for water heating applications. Grilles available as double-deflection and incustom colors. Electric Strip Heat from 0.5 to 5 kW.6

AHRI Cooling Capacity- SV SeriesARI Certified Cooling CapacityAirtherm SV Series Hi-Performance Vertical fan coils have been rated in accordance with ARI Standard440-2005 for room fan-coils air-conditioners and are certified by the Air-Conditioning and RefrigerationInstitute to meet the following product performance ratings:COOLING CAPACITYARI APPROVED STANDARD RATINGSSIZESERIES /MOTORTYPE / #004SV SeriesStandard (1)006SV SeriesStandard (1)008SV SeriesStandard (1)010SV SeriesStandard (1)012SV SeriesStandard (1)015SV SeriesStandard (2)018SV SeriesStandard (2)022SV SeriesStandard (2)Notes:STYLERATEDCFMB, DF, RG, QB, DF, RG, QB, DF, RG, QB, DF, RG, QB, DF, RG, QB, DF, RG, QB, DF, RG, QB, DF, RG, 405365295535297367367361035103510351) Based on 80 F DB and 67 F WB EAT, 45 F EWT, 10 F temperature rise, high fan speed. Motor voltage115/1/60 power source. Air flow under dry coil conditions. Water pressure drops shown in feet of water.All units are listed under UL Category Control No. LZFE.2) Ratings are based on actual CFM. Standard coils for 004 is 3 rows and 006-022 is 4 rows.3) Legend - B SVTB; D SDTB; F SCTF; R Front return deluxe; G Rear return and bottom supply;Q Rear return and bottom supply deluxe.7

Heating Performance - CV SeriesHeating PerformanceHeating PerformanceSIZESERIES /MODELCOIL ROWS/(FPI)RATEDCFMMBHGPMWPD(FT./H2O)004SV Series(Basic / Deluxe)1 Row (12)52526.71.31.82 Rows (12)1.352540.12.0SV Series(Basic / Deluxe)1 Row (12)61033.61.72.92 Rows (12)61049.92.52.1SV Series(Front Return)1 Row (12)75037.81.93.32 Rows (12)75057.32.82.4SV Series(Basic / Deluxe)1 Row (12)78035.31.82.72 Rows (12)78055.32.72.0SV Series(Front Return)1 Row (12)97538.71.93.12 Rows (12)97562.33.12.3SV Series(Basic / Deluxe)1 Row (12)93036.41.83.32 Rows (12)93059.12.92.5SV Series(Front Return)1 Row (12)1,10039.01.93.72 Rows (12)1,10064.43.22.81 Row (12)1,13543.22.24.92 Rows (12)3.7006008010SV Series(Basic / Deluxe)1,13570.73.5SV Series(Front Return)1 Row (12)1,35038.51.90.72 Rows (12)1,35069.33.41.2SV Series(Basic / Deluxe)1 Row (12)1,62562.83.14.02 Rows (12)1,625100.95.03.4SV Series(Front Return)1 Row (12)1,62562.83.15.22 Rows (12)1,625103.75.25.4SV Series(Basic / Deluxe)1 Row (12)1,91075.53.85.42 Rows (12)1,910121.56.04.5SV Series(Front Return)1 Row (12)1,91054.22.60.92 Rows (12)1,910124.26.27.0SV Series(Basic / Deluxe)1 Row (12)2,09086.84.36.82 Rows (12)2,090138.86.95.71 Row (12)2,09063.93.21.22 Rows (12)2,090138.86.95.7012015018022SV Series(Front Return)Notes:Based on 70 F DB EAT, 180 F EWT, 40 F temperature drop, high fan speed. Motor voltage 115/1/60power source. Air flow under dry coil conditions. Water pressure drops shown in feet of water.8

Coil DataCoil DataCoils are made from ½” O.D. copper tubing with .016” wall thickness, and tubes are staggered formaximum heat transfer. A manual air vent is standard on all hydronic coils. DX and steam coils do notinclude manual-air vent. All coils are 100% underwater pressure tested to 350 PSIG with a 300 PSIGworking pressure. Steam coils are rated for up to 15 PSIG or 250ºF.Coils are available in two- or four-pipe, and from one- to eight-row configurations for SPCV Seriesunits All units available with any combination of chilled or hot water, steam or direct expansion.Custom circuiting is available.Coil Rows003004006008010012015018022S T A N D A R DVertical SV CoilCoil Rows004006008010012015018022Single-Row CoilTwo-Row CoilS T A N D A R DThree-Row CoilFour-Row CoilFive-Row CoilSix-Row CoilO P T I O N A LSeven-Row Coil*Eight-Row Coil* Seven-row coil maximum when selecting a DX coil with a hot water coil.Coil Options: DX – Includes distributor and nozzle, TXV must be field furnished and installed Steam – 1-15 PSIG Opposite End Connection (E). Place the “E” - pipe-hand connection in the eleventhdigit of the model number - when ordering Preheat Coil Position (PREHEAT) – Standard coil is reheat position Phenolic Anti-Corrosion Coating (PAC) Stainless Steel Tubes/Fins/End Plates Copper Fins/Tubes/End Plates 6-16 Fins Per Inch (Standard is 12 FPI)Coil connections on thehilled water side for SV004-SV006 is ½” and ¾” on SV008-022.The hot water connection is ½” on the SV004-022.9

Electric HeatElectric HeatElectric heat may be furnished with either hydronic, direct expansion or steam coils and isfactory-mounted, wired, and tested. Option-equipped with low-watt density (for long life) nichromewire elements. The heater has a built-in, high limit, and fusible link to provide maximum safety.Vertical ( SV 743.339.132.510

Air Flow DataAir Flow DataAir flow shown below is under dry coil conditions.Vertical ( SV Series)0.00MODEL /STYLECOILROWSHISV Series004Basic / Deluxe (Standard)3 ROW4 ROW3 ROW4 ROW3 ROW4 ROW3 ROW4 ROW3 ROW4 ROW3 ROW4 ROW3 ROW4 ROW3 ROW4 ROW3 ROW4 ROW3 ROW4 ROW3 ROW4 ROW3 ROW4 5113013701355164016201920190021202100SIZE006SV SeriesBasic / Deluxe (Standard)006Front ReturnSV Series(Standard)008SV SeriesBasic / Deluxe (Standard)008Front ReturnSV Series(Standard)SV Series010Basic / Deluxe (Standard)010Front ReturnSV Series(Standard)SV Series012Basic / Deluxe (Standard)012Front ReturnSV Series(Standard)015Front ReturnSV Series(Standard)018Front ReturnSV Series(Standard)022Front ReturnSV Series(Standard)Notes:0.05MED 0MED 5MED MED ED 40925100599011851170143514151630161017501730MED 28512401220Ratings and capacity tables based on nominal CFM.11

Motor DataMotor DataMotors are wired to a junction box ready for single-point field connection. Outstanding features include: Quick-Connect Plug 122ºF maximum operating temperature Permanent Split Capacitor Custom motor mounts designed to reduce Thermal overload protectionnoise and eliminate vibration 1050 RPM for lower operating costs Stators are epoxy-dipped for more efficient Oversized bearings and permanentlymotor coolinglubricated and sealedOptional motors: 208V-1Ø-60 motors 277V-1Ø-60 motors 230/220V-1Ø-60 motors50-Hz motors in specified voltagesVertical ( SV Series)Voltage/Watts60 Hertz Single-PhaseMotors (1100 RPM)115V208V230V277VSizeSeries / Model /Motor TypeHP 4SV Front Return (Std)SV Front Return (Std)1/10 (1)1/10 75228SV Basic/Deluxe (Std)1/10 (1)11.61810.901810.81810.8181SV Front Return (Std)1/6 22*SV Basic/Deluxe (Std)1/6 (1)12.23161.103161.03161.3316SV Front Return (Std)1/4 (1)13.23601.603601.53601.2360SV Basic/Deluxe (Std)1/6 (1)12.43561.203561.13561.5356SV Front Return (Std)1/4 (1)13.33831.803831.63831.3383SV Basic/Deluxe (Std)1/4 (1)13.24131.704131.54131.7413SV Front Return (Std)1/3 (1)14.55402.605402.45401.8540SV Basic/Deluxe (Std)1/6 (2)24.65472.305472.15471.6547SV Front Return (Std)1/6 (2)24.65532.405532.25531.6553SV Basic/Deluxe (Std)1/4 (2)26.46443.306443.06442.4644SV Front Return (Std)1/4 (2)26.46543.306543.06542.6654SV Basic/Deluxe (Std)1/3 (2)29.07935.307934.87933.6793SV Front Return (Std)1/3 (2)29.07985.307984.87983.6798* Data reflects combined performance of (2) motors for both Horizontal and Vertical units.Notes: Motor full load amps listed refer to NEC amps. Actual motor nameplate amps may vary.1312

Sound DataSound DataVertical (SV Series)OCTAVE BANDSize004Series /FanModelSpeedSV SeriesBasic / ighMediumLowSV SeriesBasic / Deluxe006SV SeriesFront ReturnSV SeriesBasic / Deluxe008SV SeriesFront ReturnSV SeriesBasic / Deluxe010SV SeriesFront ReturnSV SeriesBasic / Deluxe012SV SeriesFront Return015SV SeriesFront Return018SV SeriesFront Return022SV SeriesFront ReturnNotes:2345678CENTER FREQUENCY .740.829.026.842.432.130.845.632.731.91) Power levels are in dB RE 10-12 watts.2) Sound data tested in accordance with ASHRAE Standard 68 and ARI Standard 260 and 350.3) Air Flow under dry coil conditions.13

Certified Dimensional Drawings - SVTB & SDTB SeriesHI-PERFORMANCE CASED VERTICAL - BASIC/DELUXE BOTTOM RETURN400 - 800 CFM MODEL FILTER CDEFG BASIC / DELUXEAB40020-5/3214-5/3257-5/8 14-5/3257-5/810-15/329-13/322-7/323-1/3220X20X1 SIZEAll sizes shown in inches.Right-hand unit shown, left-hand unit opposite.Coil connections determined by facing the supply-air opening.Electrical junction box is located on the same side as the coil connections.Unit must be installed level and condensate drain lines should be trapped.Drain pan is powder-coated epoxy with a 1/8” thick closed-cell insulation and has 3/4” NPTprimary and secondary drain connections.Entire cabinet, scroll and blower wheel are heavy-gauge, galvanized steel.Coil Connections: 1/2” CW and HW on 004-008.14

Certified Dimensional Drawings - SVTF & SDTB SeriesHI-PERFORMANCE CASED VERTICAL - BASIC/DELUXE BOTTOM RETURN1000 - 2200 CFM MODEL BASIC/ DELUXE 1000 FILTER /162-1/8 3-1/1620X20X115003624-5/862-3/42410-1/23 4-5/862-3/42410-1/23330X24X1 All sizes shown in inches.Right-hand unit shown, left-hand unit opposite.Coil connections determined by facing the supply-air opening.Electrical junction box is located on the same side as the coil connections.Unit must be installed level and condensate drain lines should be trapped.Drain pan is powder-coated epoxy with a 1/8” thick closed-cell insulation and has 3/4” NPTprimary and secondary drain connections.Entire cabinet, scroll and blower wheel are heavy-gauge, galvanized steel.Coil Connections: 1/2” CW on CV010; 3/4” on 012-022 and 1/2” HW on 010-022.15

Certified Dimensional Drawings - SVTF & SDTF SeriesHI-PERFORMANCE CASED VERTICAL - BASIC FRONT RETURN400 - 800 CFMMODEL FILTERBASIC / 5/810-15/329-13/322-7/323-1/3220X20X1All sizes shown in inches.Right-hand unit shown, left-hand unit opposite.Coil connections determined by facing the supply-air opening.Electrical junction box is located on the same side as the coil connections.Unit must be installed level and condensate drain lines should be trapped.Drain pan is powder-coated epoxy with a 1/8” thick closed-cell insulation and has 3/4” NPTprimary and secondary drain connections.Entire cabinet, scroll and blower wheel are heavy-gauge, galvanized steel.Coil Connections: 1/2” CW and HW on 004-008.16

Certified Dimensional Drawings - SVTF & SDTF SeriesHI-PERFORMANCE CASED VERTICAL - BASIC FRONT RETURN1000 - 2200 CFMMODEL FILTERBASIC / 122003624-5/862-3/42410-1/23330X24X1All sizes shown in inches.Right-hand unit shown, left-hand unit opposite.Coil connections determined by facing the supply-air opening.Electrical junction box is located on the same side as the coil connections.Unit must be installed level and condensate drain lines should be trapped.Drain pan is powder-coated epoxy with a 1/8” thick closed-cell insulation and has 3/4” NPTprimary and secondary drain connections.Entire cabinet, scroll and blower wheel are heavy-gauge, galvanized steel.Coil Connections: 1/2” CW on CV010; 3/4” on 012-022 and 1/2” HW on 010-022.17

Certified Dimensional Drawings - SCTF SeriesHI-PERFORMANCE CASED VERTICAL - FRONT RETURN/TOP SUPPLY600 - 1200 CFM MODELFRONT RETURN / 200304512-1/48-7/820X25X1All sizes shown in inches.Right-hand unit shown, left-hand unit opposite.Coil connections determined by facing the supply-air opening.Electrical junction box is located on the same side as the coil connections.Unit must be installed level and condensate drain lines should be trapped.Drain pan is powder-coated epoxy with a 1/8” thick closed-cell insulation and has 3/4” NPTprimary and secondary drain connections.Entire cabinet, scroll and blower wheel are heavy-gauge, galvanized steel.Coil Connections: 1/2” CW for 006; 3/4” on 008-022 chilled water. 1/2” HW on 006-022 hot water.18

Certified Dimensional Drawings - SCTF SeriesHI-PERFORMANCE CASED VERTICAL - FRONT RETURN/TOP SUPPLY1500 - 2200 CFM MODELFRONT RETURN / 800374832-1/42-3/8(2) 25X16X12200414836-1/42-3/8(2) 25X20X1All sizes shown in inches.Right-hand unit shown, left-hand unit opposite.Coil connections determined by facing the supply-air opening.Electrical junction box is located on the same side as the coil connections.Unit must be installed level and condensate drain lines should be trapped.Drain pan is powder-coated epoxy with a 1/8” thick closed-cell insulation and has 3/4” NPTprimary and secondary drain connections.Entire cabinet, scroll and blower wheel are heavy-gauge, galvanized steel.Coil Connections: 1/2” CW for 006; 3/4” on 008-022 chilled water. 1/2” HW on 006-022 hot water.19

Weights and MeasuresWeights and MeasuresThe following SV Series weights and measures are based on fan coil units only. Add approximately 20%for packaging and crating.UnitSV & DF SeriesBasic / DeluxeSCTF SeriesFront ons / InchesHeight Width 240249Dimensions / MillimetersHeight Width 71759610010110510911320

Guide SpecificationsGeneralFurnish and install Airtherm SV Series VerticalDirect Drive Fan Coil units as indicated on theplans and in the specifications. All units shall becompletely factory-assembled, tested and shippedas one working unit. All units shall be capable ofmeeting or exceeding the scheduled capacities forcooling, heating and air delivery. Dimensions foreach model and size shall be considered maximums.Units shall be UL listed and also in compliance withUL/ANSI Standard 1995, and be certified as complying with the latest edition of ARI Standard 440.ConstructionAll unit chassis shall be fabricated of heavy gaugegalvanized steel panels able to meet 125-hour saltspray test per ASTM B-117. All exterior panels shallbe insulated with 1/2” thick, 3.35 pound per cubicfoot, dual density fiberglass insulation rated for amaximum air velocity of 3600 f.p.m. Insulationshall conform to UL 181 for erosion and NFPA90A and 90B for flame spread (25) and smokedeveloped (

fan coil for installation in a closet-type enclosure. The front panel is removable for easy service access to the slide-out blower assem-bly, with quick-connect plug. Vertical Front Return with return-air grille option allows unit to be furred-in. Grille mounts to drywall for easy access without the expense of a closet door. Vertical