Motor Control Centers—Low Voltage Section 15 - Turtle

Transcription

Section Updated 10 / 2016Motor Control Centers—Low VoltageSection 15E9000Motor Control Centers Introduction .15-2EVOLUTION SERIES E9000 Key Benefits .15-3Motor Control Centers Features (SC/MC Program).15-4GE Fastrac Program – MCC Units Quick Selection Guide, E9000Motor Control Starter Units.15-5Motor Control Feeder Units.15-9MCC Sections .15-11Renewal Parts.15-13GE Fastrac Program – MCC Units Quick Selection Guide,CR8000Motor Control Starter Units.15-14Motor Control Feeder Units.15-18Renewal Parts.15-19Rev. 11/13Data subject to changewithout noticewww.geindustrial.comEVOLUTION SERIES E9000 /8000 Low VoltageMotor Control CentersProduct References:Engineered Products CatalogApplication and Selection GuideApplication and Selection GuideSection 10E9000 DET291ASpectra/8000 GET6729BuyLog Catalog15-1

Motor Control Centers—Low VoltageSection 15GE Motor Control CentersIntroductionGE motor control centers offer an ideal means of quickly providingcentralized motor control and other related control equipment.A pre-engineered version of the GE motor control center is available at short-cycle and mid-cycle shipment. The product scopeavailable is more limited than with normal cycle shipments, andincludes certain combination starter units, feeder units, distribution transformers, lighting panels, relaying panels, programmablecontrollers and other miscellaneous devices to be installed in asingle, floor-mounted enclosure and fed from a commonenclosed horizontal and vertical bus system.Each GE motor control center vertical section is constructed of0.090-inch (13-gauge) steel which is subjected to a special corrosion-resistant zinc-phosphate treatment followed by a powderpaint process using ANSI-61 light gray alkyd-enamel paint. Referto the factory for additional color options. Each section housesthe horizontal and vertical bus, horizontal and vertical wirewaysand the compartmentalized individual control units. Standardunit construction is Class I Type B wiring1. Factory assembled,wired and tested units are mounted in each vertical section,and sections are easily bolted together to form a motor controlcenter line-up. The entire line-up is then powered by a singleincoming-line connection.Standard UL labeled NEMA 1 enclosure contains 600-ampere,three-phase, copper tin-plated horizontal main bus, 300-ampere,three-phase, copper tin-plated vertical bus and is braced towithstand a fault current of 65,000 rms symmetrical. Each vertical section must be priced to include 72 inches of vertical spaceunits consisting of starters, feeders, transformers, panels, incoming terminal boards and/or enclosure spaces for future units.1Typical diagrams can be found in the Application and Selection Guide for DET291Section “L”.15-2BuyLog Catalogwww.geindustrial.comRev. 11/13Data subject to changewithout notice

Motor Control Centers—Low VoltageSection 15GE Motor Control CentersEVOLUTION SERIES E9000 Key BenefitsSafety:—No Hot bus rework up to 600A—Hi-Visible Trip Indication—Door and unit interlocks—UBC Seismic Zone 4 Standard—Six Sigma DesignedSize:—6" reduction—Sz 3, 5—6" to 36" reduction VFD’s—6" Size 1 FVNR—6" 150A Feeder—12" 250A Feeder—36" Size 5 Plug-In, two in a section—300VA CPT—No additional Space—Plug In Buckets to Size 5—Plug In Feeders to 600ASimplicity:—Easy Unit Insertion/Removal—Snap-In Shelves—Easily Quoted Fastrac MCCs—Manufacturing FlexibilityScope:—450 Hp VFD’s—500 Hp SSS—250A and 600A Stabs—TVSS 65-200K Surge Current—Automatic Transfer Switches to 1200ARev. 11/13Data subject to changewithout noticewww.geindustrial.comBuyLog Catalog15-3

Motor Control Centers—Low VoltageSection 15GE Motor Control CentersShort/Mid Cycle ProgramFeaturesHighlights of the Evolution SC/MC Program:The Evolution SC/MC is a pre-engineered, factory assembled, fullytested motor control center that contains all the standard features of the Evolution motor control center, including someoptions.All sections and units will be UL labeled where possible. Refer toCompany if labeling is critical.Please contact your distributor or GE for scope, pricing, andordering.No changes are allowed to Evolution SC/MC bill-ofmaterial after order entry.I Structure (20-inch wide is standard)—13- or 20-inch deep—Back-to-back mounting (20-inch deep only)—NEMA 1 gasket, 2, 12, 3R non-walk-in—24-inch wide enclosures—Corner section enclosures—Special enclosures—Engraved nameplates (optional)—Addition of “Field Installed Kits”II Bus Systems—Voltage: 208, 240, 480, 575 volts—3-phase, 3-wire, or 3-phase, 4-wire—Main bus: 600, 800, 1000, 1200 ampere—Vertical bus: 300, 450, 600 ampere, section-by-section—Optional ground bus: 300, 375, 600 ampere—Neutral bus: 300, 400, 600, 800, 1000 ampere—Optional silver plating—Back-to-back construction (rear vertical bus)—“Vertical Bus Plugs” installed in unused stab openingsIII Incoming Line—600 amperes with 18 inches of pull space—Circuit breakers thru 1200 amperes—Fusible switches thru 600 amperesIV Feeders and Mains—Feeders—800-ampere Spectra—Feeders—600-ampere fused switch—Main—1200-ampere Spectra—Shunt trip and UV releaseV Combination Starter Units—Control Power Transformer (CPT) (optional)—“Extra” auxiliary interlocks (optional)—Line-to-line control—Line-to-neutral control—Separate control power or common CPT—FVNR—Size 1 thru 6—FVR—Size 1 thru 4—RVNR—Size 2 thru 5—2S2W—Size 1 thru 4—2S1W—Size 1 thru 4—NEMA Type 1B wiring—Interlocks mounted on circuit breaker andfusible switch (optional)15-4BuyLog Catalogwww.geindustrial.comRev. 11/13Data subject to changewithout notice

Motor Control Centers—Low VoltageSection 15GE Fastrac Program—MCC Units Quick Selection GuideEVOLUTION SERIES E9000 This Quick Selection Guide covers Control Center starters andfeeders, including full and reduced voltage, reversing and nonreversing, two-speed single and dual winding starters, in sizes1-5. It also covers EVOLUTION SERIES E9000 Sections. Forother units, see the Engineered Products Catalog, Section 10.2 Select Starter Type and SizeFind the starter type required. Transfer the product number digitsto the boxes marked 2 in the product number.Starter TypeMotor Control Starter UnitsFor each of the following steps, find the option—MCC type, startertype, size, disconnect, control power, pilot lights, etc.— that meetsthe need. Transfer the corresponding product number digit(s) tothe product number box(es).When you have finished, you will have built a complete productnumber.FVNRFV R1 Select Motor Control Center TypeSelect motor control center type. Transfer the product numberdigits to the box marked 1 in the product number line.MCC TypeProduct Number DigitEVOLUTION SERIES E9000 E2S1WVariableTorque2S2WVariableTorqueSizeProduct Number Digits1H1 D42E23E34E45E5RVNR1H1 is a 6" 10HP compact starter.All Fastrac units have the following as standard:A. NEMA 12 gasketingB. Isolated N.O. overload alarm contact (not wired to TB)C. Auxiliary contacts wired to the TB as noted below:FVNR and RVNR Starters—(1) N.O. (1) N.C.FVR and 2S Starters—(1) N.O. per contactorNote: Contact Factory for pricing.Rev. 11/13Data subject to changewithout noticewww.geindustrial.comBuyLog Catalog15-5

Page Updated 10 / 2016Motor Control Centers—Low VoltageSection 15GE Fastrac Program—MCC Units Quick Selection GuideEVOLUTION SERIES E9000 3 Select Starter Disconnect4 Select Control PowerUse the first table to identify desired disconnect device. (Note thatthese are for basic applications; see publication DET-291 forEVOLUTION SERIES E9000 for more information.) Then, from thesecond table select starter disconnect. Transfer the productnumber digit to the box marked 3 in the product number line.If H1 is selected in Step 2 , product number digits U or W mustbe selected.Standard control power transformer (CPT) ratings are adequate tohandle the starter-coil current and three pilot lights. If additionalburdens are expected, larger transformers should be specifiedfrom among those shown in the first table below. From thesecond table below, select the control power desired. Transferthe product number digit to the box marked 4 in the productnumber line. If H1 is selected in Step 2 , product number digits 1or 5 must be selected. Product number digit 1 is for 100VA CPT.StarterSizeMag OnlyCircuit BreakerThermal MagCircuit BreakerSpectra Spectra Short Circuit Rating230V460V575V1Starter Type and SizeCPT Std. VAOversize VA- 65k656525All Size 160150Spectra -100kSpectra - 100k100100—All Size 2150ÐSpectra - 65kSpectra - 65k656525All Size 3300ÐSpectra - 100kSpectra - 100k100100—All Size 4300ÐSpectra - 65KSpectra - 65K656565All Size 5100ÐSpectra - 100KSpectra - 100K100100100451, 2, 345- 65k1 At 575V current limiters may be er Size123ControlPower(120 Vac)4ProductNumberDigitStd. CPT1FSW-J3ROversize2Spectra – 65Mag Only2ULine-to-Line4Spectra – 100Mag OnlyVCommon/SeparateSource5Spectra – 65Thermal Mag2WSpectra – 100Thermal MagXStarter Size123454At 380V 50Hz, Control Volts will be 110Vac; at 575V 60Hz, Control Voltswill be 115Vac.2 25KAIC @ 575V.3J time delay.Note: Contact Factory for pricing.15-6BuyLog Catalogwww.geindustrial.comRev. 11/13Data subject to changewithout notice

Motor Control Centers—Low VoltageSection 15GE Fastrac Program—MCC Units Quick Selection GuideEVOLUTION SERIES E9000 5 Select Pilot Devices5 Select Pilot Devices (continued)Select pilot devices desired by starter type. See Pilot Devicestable below and note the lamp type as either Incandescent orLED. Transfer the product number digits to the boxes marked 5in the product number line. If H1 is selected in Step 2 , a pilotdevice with an asterisk (*) must be selected.StarterTypeFVNR &RVNR &RVSSFVRPilot DeviceStarterTypePilot DeviceNONE - Blank Pilot DeviceBracket ProvidedIncandescentLEDProduct Number Digits Product Number DigitsNONE - Blank Pilot DeviceBracket ProvidedNN*-IncandescentLEDProduct Number Digits Product Number Digits2S1W &2S2WNN*-RED/AMBER LGT STDEFSFRED/AMBER LGT PTTESSSR/A/G LGT STDEGSGSTR/A/G LGT PTTETFAST/SLOW/STOP PBEN-FAST/SLOW/STOP PB R/A LGT STDEBSBFAST/SLOW/STOP PB R/A LGT PTTEPSPFAST/SLOW/STOP PB R/A/G LGT STDECSCOS*FAST/SLOW/STOP PB R/A/G LGT PTTEQSQOTFAST/SLOW/OFF/AUTO (F/S/O/A) SWFN-AN*-F/S/O/A SW R/A LGT STDFBTBH/O/A SW. RED LGT STDAB*OB*F/S/O/A SW R/A LGT PTTFPTPH/O/A SW. RED LGT PTTAPOPF/S/O/A SW R/A/G LGT STDFCTCH/O/A SW. R/G LGT STDAC*OC*F/S/O/A SW R/A/G LGT PTTFQTQH/O/A SW. R/G LGT PTTAQOQH/O/A SW. STOP/START PB RED LGT STDADODH/O/A SW. STOP/START PB RED LGT PTTARORSTOP/START PBBN*-STOP/START PB RED LGT STDBB*PB*STOP/START PB RED LGT PTTBPPPSTOP/START PB R/G LGT STDBCPCSTOP/START PB R/G LGT PTTBQPQOFF/ON SW.GN*-OFF/ON SW. RED LGT STDGB*UB*OFF/ON SW. RED LGT PTTGPUPOFF/ON SW. R/G LGT STDGC*UC*OFF/ON SW. R/G LGT PTTGQUQNONE - Blank Pilot DeviceBracket ProvidedNN*-RED LGT STDAE*OE*RED LGT PUSH-TO-TEST (PTT)AFOFRED/GREEN LGT STDAS*RED/GREEN LGT PTTATHAND/OFF/AUTO (H/O/A) SW.RED/GREEN LGT STDCEQERED/GREEN LGT PTTCRQRRED/AMBER LGT STDCFQFRED/AMBER LGT PTTCSQSR/A/G LGT STDCGQGR/A/G LGT PTTCTQTFWD/REV/STOP PBCN-FWD/REV/STOP PB R/A LGT STDCBQBFWD/REV/STOP PB R/A LGT PTTCPQPFWD/REV/STOP PB R/G/A LGT STDCCQCFWD/REV/STOP PB R/G/A LGT PTTCQQQFWD/OFF/REV SWDN-FWD/OFF/REV SW RED LGT STDDBRBFWD/OFF/REV SW RED LGT PTTDPRPFWD/OFF/REV SW R/G LGT STDDCRCFWD/OFF/REV SW R/G LGT PTTDQRQ6 Select Overload RelaySelect overload relay type. Transfer the product number digitsto the box marked 6 in the product number line. If H1 is selectedin Step 2 , product number digit 2 must be selected. *If H1 isselected in Step 2 , the overload provided is the Series RT overload.Relay TypeProduct Number DigitStandard1Ambient Compensated2*Solid State37 Select Control Terminal BoardSelect control disconnect terminal board. Transfer the productnumber digits to the box marked 7 in the product number line. IfH1 is selected in Step 2 , product number digit H must beselected.Control Disconnect Terminal BoardProduct Number DigitStandard High-DensityH8 Select HorsepowerSelect horsepower. Transfer the product number digits to theboxes marked 8 in the product number line. Note that someproduct number digits consist of a decimal point.HorsepowerProduct Number DigitsHorsepowerProduct Number 3/4.75400401001500501 1/21.560060200275075300310010050051251257 1/27.515015010010200200Note: Contact Factory for pricing.Rev. 11/13Data subject to changewithout noticewww.geindustrial.comBuyLog Catalog15-7

Motor Control Centers—Low VoltageSection 15GE Fastrac Program—MCC Units Quick Selection GuideEVOLUTION SERIES E9000 9 Select System Voltage10 OEMSelect system voltage. Transfer the product number digit tothe box marked 9 in the product number line. If H1 is selected inStep 2 , product number digits A or C must be selected.Fastrac UnitsFastrac units designed for OEM use are engineered and built withthe same components and layout as the standard Fastrac units.Power wiring is provided: however, to allow the maximum flexibility for OEM users, no control wiring is provided.Product numbers are the same as the standard Fastrac unitswith the addition of two additional suffix letters, XX.VoltageProduct Number Digit480V 60 HzA208V 60 HzB240V 60 HzCExample:575V 60 HzDStandard Fastrac Unit380V 50 HzEOEM Fastrac ProductNumberNote: Contact Factory for pricing.15-8BuyLog Catalogwww.geindustrial.comRev. 11/13Data subject to changewithout notice

Page Updated 10 / 2016Motor Control Centers—Low VoltageSection 15GE Fastrac Program—MCC Units Quick Selection GuideEVOLUTION SERIES E9000 Motor Control Feeder Units4 Select Feeder DeviceFor each of the following steps, find the option—MCC type,disconnect type, amp rating, feeder devices—that meets theneed. Transfer the corresponding product number digits to theproduct number boxes for either the standard or OEM extendedfeeder unit. When you have finished, you will have built a completeproduct number.Select feeder device from one of the following two tables. Transferthe product number digits to the boxes marked 4 in the productnumber line for either the standard or OEM extended feeder unit.Standard Feeder Units1 Select Motor Control Center TypeDeviceSelect motor control center type. Transfer the product numberdigit to the box marked 1 in the product number line.MCC TypeEVOLUTION SERIESSELTSELT-LProduct Number DigitE9000 Product Number DigitsCircuit BreakerÐFBFusible Switch R208/240VFRFusible Switch R480/600VFSFusible Switch J480/600VFJ3 Select Amp RatingSelect amp rating for either circuit breaker trip or Class R fuse.Transfer the product number digits to the boxes marked 3 in theproduct number FPT2501001002512SFPTSGL1Cw-LT & INST150100656524GLI1SGL1Cw-LT/INST & GF150100656524LIG1SGL4Cw-LT & INST400100656524GLI4SGL4Cw-LT/INST & GF400100656524LIG4SGL6Cw-LT & INST600100656524GLI6SGL6Cw-LT/INST & R62 Select Feeder Disconnect TypeVoltage480150SEPTType240150ESelect disconnect type. Transfer the product number digits to theboxes marked 2 in the product number line.Short CircuitRating KA VoltsAmpRating(Max.)FSWAmpsProduct Number DigitsAmpsProduct Number �1 Unit height for 480V and 600V is 30”.5 Select System VoltageSelect system voltage. Transfer the product number digit tothe box marked 5 in the product number line.ÐVoltageProduct Number Digit480V 60 HzA208V 60 HzB240V 60 HzC575V 60 HzD380V 50 HzEStandard Feeder Unit Product Number123Door and Shelf Kit45Door and Shelf Kit66" – EK066 – EK3030"12" – EK1236" – EK3618" – EK1842" – EK4224" – EK2448" – EK48Note: Contact Factory for pricing.Rev. 11/13Data subject to changewithout noticewww.geindustrial.comBuyLog Catalog15-9

Page Updated 10 / 2016Motor Control Centers—Low VoltageSection 15GE Fastrac Program—MCC Units Quick Selection GuideEVOLUTION SERIES E9000 OEM Extended Feeder Units for EVOLUTION SERIES E9000 LT250SFPT250SGL4Bw-LT & Inst.SGL4Bw-LT/Inst. & GFSGL6Bw-LT & Inst.SGL6Bw-LT/Inst. & GF400400600600Short CircuitRating KA LI63036GLI63642GLI64230LIG63036LIG63642LIG642OEM Extended Feeder Unit Product Number12345Note: Contact Factory for pricing.15-10BuyLog Catalogwww.geindustrial.comRev. 11/13Data subject to changewithout notice

Motor Control Centers—Low VoltageSection 15GE Fastrac Program—MCC Units Quick Selection GuideEVOLUTION SERIES E9000 5 Bus PlatingEVOLUTION SERIES E9000 MCC SectionsThis is for selection of one to three sections of 20" deepEVOLUTION SERIES E9000 motor control centers without units.Each section will be shipped with blank doors. The typical sectionwill have (3) 12", (1) 24" and (2) 6" doors and shelves.For each of the following steps, find the option–short circuitrating, NEMA enclosure, etc.–that meets the need. Transfer thecorresponding product number digit(s) to the corresponding product number box(es). When you have finished, you will have built acomplete product number.Select the bus plating. Transfer the product number digit tothe box marked 5 in the product number line.Short Circuit RatingA42 kAICB65 kAICC7Select the enclosure type. Transfer the product number digitto the box marked 2 in the product number line.3Product Number Digit1 Gasketed1122Main Bus RatingProduct Number Digit600A61200A2Ground Bus8Ground BusProduct Number Digit300A3600A6Neutral BusSelect the neutral8 bus. Transfer the product number digit tothe box marked in the product number line.System VoltageSelect the system voltage. Transfer the product number digit to3the box marked in the product number line.4SSelect the ground bus. Transfer the product number digit to7the box marked in the product number line.2 NEMA Enclosure TypeNEMA Enclosure TypeTSilverSelect the main bus rating. Transfer the product number digit tothe box marked 6 in the product number line.Product Number Digit25 kAICProduct Number DigitTin6 Main Bus Rating1 Select Short Circuit RatingSelect short circuit rating. Transfer the product number digit tothe box marked 1 in the product number line.Bus PlatingSystem VoltageProduct Number Digit480V 60 HzA208V 60 HzB240V 60 HzC575V 60 HzD380V 50 HzENeutral BusProduct Number DigitNone0300A3600A69Horizontal Wire-WaySelect the horizontal9 wire-way. Transfer the product number digitto the box marked in the product number line.Horizontal Wire-WayProduct Number Digit12" Top-6" BottomT12" Top-12" BottomB10System WiresMain LocationSelect the system4 wires. Transfer the product number digit tothe box marked in the product number line.10 the main. Transfer the product number digitSelect the location ofto the box marked in the product number line.System WiresProduct Number DigitMain LocationProduct Number Digit3W3Top LeftTL4 W Neutral4Bottom LeftBLTop RightTRBottom RightBRNote: Contact Factory for pricing.Rev. 11/13Data subject to changewithout noticewww.geindustrial.comBuyLog Catalog15-11

Motor Control Centers—Low VoltageSection 15GE Fastrac Program—MCC Units Quick Selection GuideEVOLUTION SERIES E9000 1112Main TypeSelect the type of main. Transfer the product number digits to theboxes marked 11 in the product number line.Main TypeProduct Number Digits600A Splice6S1200A Splice2S600A MLO6L1200A MLO BottomMain Circuit Breaker Trip or Main Switch FuseSelect main circuit breaker trip or main switch fuse. Transferthe product number digit to the box marked 12 in the productnumber line.Main CB orMain Switch FuseProduct Number DigitNo Fuse0300A3400A4600A6800A81000A11200A22L1200A MLO Top2L600A CB6C1200A CB2C600A Switch6F13Number of Vertical Sections with Common Main BusSelect the number of sections with common main bus. Transferthe product number digit to the box marked 13 in the productnumber line.Number of Sections1SectionProductNumberL234567Product Number DigitOne1Two2Three38910111213EF Note: Contact Factory for pricing.15-12BuyLog Catalogwww.geindustrial.comRev. 11/13Data subject to changewithout notice

Motor Control Centers—Low VoltageSection 15Frequently Requested Motor Control Center Renewal PartsEVOLUTION SERIES E9000 Renewal PartsPartO/L Reset AssemblyDoor HingesTerminal BlocksWireway CoversControl Power TransformersMiscellaneousCircuit Breaker/Starter HandlesFiller Kits(Includes Shelf and Grounding Bracket)Rear Doors OnlyWire Trough Doors (4")Cooling FansBlank Unit DoorPilot Device BracketSplice Kits(Evolution to Evolution N1, N12 Only)(Standard Tin Only)Optional SemiconductorSoft Start FusesDescriptionSize 1 Standard O/LSize 1 Electronic O/LSize 2,5 Standard O/LSize 2,5 Electronic O/LSize 3,4 Standard O/LSize 3,4 Electronic O/LDoor HingesPower Pull Apart Terminal Block 50ATerminal Block Din Rail Assembly 18 Points MaxTerminal Block Din Rail Assembly 18 Points Max w/ TBControl TB 30A Male and FemaleWireway Covers Top 12" with hingesWireway Covers Top 18" with hingesCPT 150VA, 480/120 Size 1 and 2 w/o Fuse BlockCPT 300VA, 480/120 Size 1 and 2 With Fuse BlockCPT 100VA, 480/120 Size 1 1/2X, Size 5 W/O Fuse BlockStandard ShelfShelf Grounding BracketBus Shutter AssemblyVertical Bus Stab CoversWireway Knock Out PanelShelf Support - 72" HighE and F Frame CB Vertical Handle OnlyE and F Frame CB Horizontal Handle Only6"12"18"24"30"36"42"48"Rear Cover OnlyRear Hinge Door Top OnlyRear Hinge Door Bottom OnlyRear Hinge Mounting Bracket (2 Per Section)6" High12" High18" High24" High30" High36" High42" High48" High54" High60" High66" High72" HighMuffin Fan 120V OnlyTarzan Fan OnlyCase Fan AssemblyN3R Fan Assemblies6"12"18"24"30"36"42"48"6 Unit Device Plate Only3 Unit Device Plate OnlyBracket600Amp Bus800Amp Bus1200Amp Bus2000Amp Bus2500Amp Bus50Amp60Amp80Amp100Amp200Amp225Amp350AmpProduct G1RMC#020169110C1556G1Refer to 0QS200CSC#A50QS225CSC#A50QS350Motor Control Centers Parts Publications ListModelDescriptionNumberEVOLUTION SERIES E9000 InstallationGEH 40472Note: Contact Factory for pricing.Rev. 11/13Data subject to changewithout noticewww.geindustrial.comBuyLog Catalog15-13

Page Updated 10 / 2016Motor Control Centers—Low VoltageSection 15GE Fastrac Program—MCC Units Quick Selection GuideCR8000This Quick Selection Guide covers Control Center starters andfeeders, including full and reduced voltage, reversing and nonreversing, two-speed single and dual winding starters, in sizes1-5. For other units, see the Engineered Products Catalog,Section 10.Motor Control Starter Units2 Select Starter Type and SizeFind the starter type required. Transfer the product number digitsto the boxes marked 2 in the product number line.Starter TypeFVNRFor each of the following steps, find the option—MCC type, startertype, size, disconnect, control power, pilot lights, etc.— that meetsthe need. Transfer the corresponding product number digit(s) tothe product number box(es).FVRWhen you have finished, you will have built a complete productnumber.1 Select Motor Control Center Type2S1WSelect motor control center type. Transfer the product numberdigits to the box marked 1 in the product number line.MCC TypeProduct Number DigitCR8000SizeProduct Number 34D43E34E42S2WMSRVNRAll Fastrac units have the following as standard:A. NEMA 12 gasketingB. Isolated N.O. overload alarm contact (not wired to TB)C. Auxiliary. contacts wired to the TB as noted below:FVNR and RVNR Starters—(1) N.O. (1) N.C.FVR and 2S Starters—(1) N.O. per contactorNote: Contact Factory for pricing.15-14BuyLog Catalogwww.geindustrial.comRev. 11/13Data subject to changewithout notice

Motor Control Centers—Low VoltageSection 15GE Fastrac Program—MCC Units Quick Selection GuideCR80004 Select Control Power3 Select Starter DisconnectUse the first table to identify desired disconnect device.(Note that these are for basic applications; see publicationGET-6728 for more information.) Then, from the second tableselect starter disconnect. Transfer the product number digit tothe box marked 3 in the product number line.StarterSizeShort Circuit RatingMag OnlyCircuit BreakerThermal MagCircuit Breaker230V460V575VSpectra - 65kSpectra - 65k656525Spectra -100kSpectra - 100k100100—Spectra - 65kSpectra - 65k656525Spectra - 100kSpectra - 100k100100—Spectra - 65KSpectra - 65K6565Spectra - 100KSpectra - 100K1001001, 2, 345DisconnectDeviceProductNumberDigitStandard control power transformer (CPT) ratings are adequate tohandle the starter-coil current and three pilot lights. If additionalburdens are expected, larger transformers should be specifiedfrom among those shown in the first table below. From thesecond table below, select the control power desired. Transferthe product number digit to the box marked 4 in the productnumber line.Product number digit 1 is for 100VA CPT.Starter Type and SizeCPT Std. VAOversize VAAll Size 160150All Size 2150Ð65All Size 3300Ð100All Size 4300ÐAll Size 5100ÐStarter SizeFSW-RFControlPower(120 Vac)4FSW-J2RStd. CPTSpectra – 65Mag Only1USpectra – 100Mag OnlyVSpectra – 65Thermal Mag1WSpectra – 100Thermal Common/SeparateSource5Starter Size123451 25KAIC @ 575V.2 J time delay.Note: Contact Factory for pricing.Rev. 11/13Data subject to changewithout noticewww.geindustrial.comBuyLog Catalog15-15

Page Updated 10 / 2016Motor Control Centers—Low VoltageSection 15GE Fastrac Program—MCC Units Quick Selection GuideCR80005 Select Pilot Devices5 Select Pilot Devices (continued)Select pilot devices desired by startertype. See Pilot DevicesILtable below and note the lamp type as either Incandescentor LED. Transfer the product number digits to the boxesmarked 5 in the product number line.StarterTypeFVNR &RVAT &RVSSFVRPilot DeviceLEDIncandescentProduct Number Digits Product Number DigitsNONE - Blank Pilot DeviceBracket ProvidedNN*RED LGT STDAE*StarterTypePilot DeviceIncandescentLEDProduct Number Digits Product Number DigitsNONE - Blank Pilot DeviceBracket ProvidedNN-RED/AMBER LGT STDEFSFSRED/AMBER LGT PTTESSSR/A/G LGT STDEGSGST-R/A/G LGT PTTETEN-OE*FAST/SLOW/STOP PBRFAST/SLOW/STOPPB R/A LGT STDEBSBRED LGT PUSH-TO-TEST (PTT)AFOFRED/GREEN LGT STDAS*OS*2S1W &2S2WFAST/SLOW/STOP PB R/A LGT PTTEPSPFAST/SLOW/STOP PB R/A/G LGT STDECSCSQRED/GREEN LGT PTTATOTFAST/SLOW/STOP PB R/A/G LGT PTTEQHAND/OFF/AUTO (H/O/A) SW.AN*-FAST/SLOW/OFF/AUTO (F/S/O/A) SWFN-H/O/A SW. RED LGT STDAB*OB*F/S/O/A SW R/A LGT STDFBTBH/O/A SW. RED LGT PTTAPOPF/S/O/A SW R/A LGT PTTFPTPH/O/A SW. R/G LGT STDAC*OC*F/S/O/A SW R/A/G LGT STDFCTCH/O/A SW. R/G LGT PTTAQOQF/S/O/A SW R/A/G LGT PTTFQTQH/O/A SW. STOP/START PB RED LGT STDADODH/O/A SW. STOP/START PB RED LGT PTTARORSTOP/START PBBN*-STOP/START PB RED LGT STDBB*PB*6 Select Overload RelaySelect overload relay type. Transfer the product number digits tothe box marked 6 in the product number line.STOP/START PB RED LGT PTTBPPPSTOP/START PB R/G LGT STDBCPCRelay TypeProduct Number DigitSTOP/START PB R/G LGT PTTBQPQStandard1OFF/ON SW.GN*-Ambient Compensated2*OFF/ON SW. RED LGT STDGB*UB*Solid State3OFF/ON SW. RED LGT PTTGPUPOFF/ON SW. R/G LGT STDGC*UC*OFF/ON SW. R/G LGT PTTGQUQNONE - Blank Pilot DeviceBracket ProvidedNN-RED/GREEN LGT STDCEQERED/GREEN LGT PTTCRQRRED/AMBER LGT STDCFQF7 Select Control Terminal BoardSelect control disconnect terminal board. Transfer the productnumber digits to the box marked 7 in the product number line.Control Disconnect Terminal BoardProduct Number DigitStandard High-DensityHRED/AMBER LGT PTTCSQSR/A/G LGT STDCGQGR/A/G LGT PTTCTQTFWD/REV/STOP PBCN-FWD/REV/STOP PB R/A LGT STDCBQBFWD/REV/STOP PB R/A LGT PTTCPQPFWD/REV/STOP PB R/G/A LGT STDCCQCFWD/REV/STOP PB R/G/A LGT PTTCQQQ1/4.2515015FWD/OFF/REV SWDN-1/3.3320020FWD/OFF/REV SW RED LGT STDDBRB3/8.3825025FWD/OFF/REV SW RED LGT PTTDPRPFWD/OFF/REV SW R/G LGT STDDC1/2.5030030RCFWD/OFF/REV SW R/G LGT PTTDQ3/4.75400401001500501 1/21.560060200275075300310010050051251257 1/27.515015010010200200RQ8 Select HorsepowerSelect horsepower. Transfer the product number digits to theboxes marked 8 in the product number line. Note that someproduct number digits consist of a

Motor Control Centers—Low Voltage GE Motor Control Centers Section 15 Features The Evolution SC/MC is a pre-engineered, factory assembled, fully tested motor control center that contains all the standard fea-tures of the Evolution motor control center, including some options. All sections and units will be UL labeled where possible. Refer to