Florida Product Approval

Transcription

127 W. Fairbanks Ave.Suite 438Winter Park, FL 32789407.644.6957 PH407.644.2366 FXcontact@buildingdrops.comBUILDING DROPSA Perfect Solution in Every DropCertificate of Authorization: 29578Product Evaluation ReportofJELD-WEN, inc.Energy Saver/Contour Wood Edge Opaque Steel OutswingDoor w/ or w/o SidelitesforFlorida Product ApprovalFL# FLReport No. 2035Florida Building Code 2010Per Rule 9N-3Method:Category:Sub – Category:1 – A (Certification)Exterior DoorsSwinging Exterior Door AssembliesProduct:Energy Saver/Contour Wood Edge OpaqueSteel Outswing Door w/ or w/o SidelitesSteel/Wood107” X 81.25” (Maximum)Material:Product Dimensions:Prepared For:JELD-WEN, inc.3737 Lakeport Blvd.Klamath Falls, OR. 97601Prepared by:Hermes F. Norero, P.E.Florida Professional Engineer # 73778Date: 05/01/2012Contents:Evaluation ReportPages 1 – 4Installation DetailsPages 5Digitally signed by Hermes F Norero, P.E. Hermes F. Norero, P.E.Reason: I am approving this documentFlorida No. 73778Date: 2012.05.01 17:42:30 -04'00'

BUILDING DROPSA Perfect Solution in Every DropCertificate of Authorization: 29578FL#:Date: 05/01/2012Report No: 2035Manufacturer:JELD‐WEN, inc.Product Category:Exterior DoorsProduct Sub‐Category:Swinging Exterior Door AssembliesCompliance Method:State Product Approval Rule 9N‐3.005 (1)(a)Product Name:Energy Saver/Contour Wood Edge Opaque Steel Outswing Door w/ or w/o Sidelites107” X 81.25” (Maximum)Scope:This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD‐WEN, inc.based on Rule Chapter No. 9N‐3.005, Method 1a of the State of Florida Product Approval,Department of Community Affairs ‐ Florida Building Commission.Hermes F. Norero, P.E. does not have nor will acquire financial interest in the companymanufacturing or distributing the product or in any other entity involved in the approval process ofthe product named herein.This product has been evaluated for use in locations adhering to the 2010 Florida Building Code.See Installation Instructions S‐2104, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) forspecific use parameters.Limits of Use:1.2.3.4.5.6.This product has been evaluated and is in compliance with the 2010 Florida Building Code,including the “High Velocity Hurricane Zone” (HVHZ).Product anchors shall be as listed and spaced as shown on details. Anchor embedment intosubstrate material shall be beyond wall dressing or stucco.When used in areas requiring wind borne debris protection this product complies withSection 1609.1.2 of the 2010 Florida Building Code and does not require an impact resistantcovering on outswing doors.Non‐Impact sidelites do require an impact resistant covering when used in areas requiringwind borne debris protection to comply with Section 1609.1.2 of the 2010 Florida BuildingCode.Site conditions that deviate from the details of drawing S‐2104 require further engineeringanalysis by a licensed engineer or registered architect.See Installation Instructions S‐2104 for size and design pressure limitations.Hermes F. Norero, P.E.Florida No. 73778Page 2 of 5

BUILDING DROPSA Perfect Solution in Every DropCertificate of Authorization: 29578FL#:Date: 05/01/2012Report No: 2035Quality Assurance:The manufacturer has demonstrated compliance of door products in Accordancewith the Florida Building Code and Rule 9N‐3.005 (3) for manufacturing under aquality assurance program audited by an approved quality assurance entity throughNational Accreditation & Management Institute, Inc. (FBC Organization #QUA1789)Performance Standards:The product described herein has been tested per: TAS 201‐94TAS 202‐94TAS 203‐94Referenced Data:1.Product Testing performed by Certified Testing Laboratory, Inc.(FBC Organization # TST1577)Report #: CTLA696W, Report Date: 11/01/20012.Quality AssuranceNational Accreditation and Management Institute(FBC Organization #: QUA 1789)Hermes F. Norero, P.E.Florida No. 73778Page 3 of 5

BUILDING DROPSFL#:Date: 05/01/2012Report No: 2035A Perfect Solution in Every DropCertificate of Authorization: 29578Installation:1. Approved anchor types and substrates are as follows:Through Frame Installation:A. For two by (2X) wood buck substrate, use #10 Wood Screw type installation anchors ofsufficient length to achieve a minimum embedment of 1.50” into the wood substrate.B. For concrete or masonry substrate where one by (1X), non‐structural, wood bucking isemployed, use 3/16” diameter ITW Tapcon type concrete screw anchors of sufficientlength to achieve minimum embedment of 1.25” into concrete or masonry.C. For concrete or masonry substrate where wood bucking is NOT employed, use 3/16”diameter ITW Tapcon type concrete screw anchors of sufficient length to achieveminimum embedment of 1.25” into concrete or masonry.Refer to Installation Instructions (S‐2104) for anchor spacing and more details of the installationrequirements.Design Pressure:Design PressureXX, OXXOX, OXO, XO, OXPositive57 PSF*Positive66 PSF*OutswingNegative57 PSFNegative70 PSF*Units meet water infiltration requirements corresponding to noted designpressures.Hermes F. Norero, P.E.Florida No. 73778Page 4 of 5

BUILDING DROPSA Perfect Solution in Every DropCertificate of Authorization: 29578FL#:Date: 05/01/2012Report No: 2035Installation MethodJELD-WEN, inc.Energy Saver/Contour Wood Edge Opaque Steel OutswingDoor w/ or w/o SidelitesHermes F. Norero, P.E.Florida No. 73778Page 5 of 5

JELD-WEN, inc. Energy Saver/Contour Wood Edge Opaque Steel Outswing Door w/ or w/o Sidelites for Florida Product Approval FL# FL Report No. 2035 Florida Building Code 2010 Per Rule 9N-3 Method: 1 - A (Certification) Category: Exterior Doors Sub - Category: Swinging Exterior Door Assemblies