127 W. Fairbanks Ave.Suite 438Winter Park, FL 32789407.644.6957 PH407.644.2366 FXcontact@buildingdrops.comBUILDING DROPSA Perfect Solution in Every DropCertificate of Authorization: 29578Product Evaluation ReportofJELD-WEN, inc.Premium Atlantic Vinyl Horizontal Slider Window(PAV 8200)forFlorida Product ApprovalFL# 14090-R1Report No. 1968Florida Building Code 2010Per Rule 9N-3Method:Category:Sub – Category:Product:Material:Product Dimensions:1 – A (Certification)WindowsHorizontal SliderPAV 8200 XO Sliding WindowVinyl74” x 62”Prepared For:JELD-WEN, inc.3737 Lakeport Blvd.Klamath Falls, OR. 97601Prepared by:Hermes F. Norero, P.E.Florida Professional Engineer # 73778Date: 3/28/2012Contents:Evaluation ReportPages 1 – 4Installation DetailsPages 5Digitally signed by Hermes F Norero,P.E.Reason: I am approving this documentDate: 2012.04.24 12:05:39 -04'00'Hermes F. Norero, P.E.Florida No. 73778

BUILDING DROPSA Perfect Solution in Every DropCertificate of Authorization: 29578Manufacturer:JELD‐WEN, inc.Product Category:WindowsProduct Sub‐Category:Horizontal SliderCompliance Method:State Product Approval Rule 9N‐3.005 (1)(a)Product Name:Premium Atlantic Vinyl Horizontal Slider Window(Non‐Impact)74” x 62”Scope:FL#: 14090-R1Date: 03/28/2012Report No: 1968This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD‐WEN, inc.based on Rule Chapter No. 9N‐3.005, Method 1a of the State of Florida Product Approval,Department of Community Affairs ‐ Florida Building Commission.Hermes F. Norero, P.E. does not have nor will acquire financial interest in the companymanufacturing or distributing the product or in any other entity involved in the approval process ofthe product named herein.This product has been evaluated for use in locations adhering to the 2010 Florida Building Code.See Installation Instructions JPAV8200 NCTL210‐3626‐1, signed and sealed by Hermes F. Norero, P.E.(FL # 73778) for specific use parameters.Limits of Use:1.2.3.4.5.This product has been evaluated and is in compliance with the 2010 Florida Building Code,including the “High Velocity Hurricane Zone” (HVHZ).Product anchors shall be as listed and spaced as shown on details. Anchor embedment intosubstrate material shall be beyond wall dressing or stucco.When used in areas requiring wind borne debris protection this product complies withSection 1609.1.2 of the 2010 Florida Building Code and does require an impact resistantcovering.Site conditions that deviate from the details of drawing JPAV8200 NCTL210‐3626‐1 requirefurther engineering analysis by a licensed engineer or registered architect.See Installation Instructions JPAV8200 NCTL210‐3626‐1 for size and design pressurelimitations.Hermes F. Norero, P.E.Florida No. 73778Page 2 of 5

BUILDING DROPSA Perfect Solution in Every DropCertificate of Authorization: 29578FL#: 14090-R1Date: 03/28/2012Report No: 1968Quality Assurance:The manufacturer has demonstrated compliance of window products in Accordancewith the Florida Building Code and Rule 9N‐3.005 (3) for manufacturing under aquality assurance program audited by an approved quality assurance entity throughNational Accreditation and Management Institute (FBC Organization #: QUA 1789)Performance Standards:The product described herein has been tested per: Referenced Data:AAMA/WDMA /CSA 101/I.S.2/A440‐05TAS 202‐941.Product Testing performed by National Certified Testing Laboratory, Inc.(FBC Organization # TST1589)Report #: NCTL‐210‐3626‐1A, Report Date: 10/08/2009Report #: NCTL‐210‐3626‐1, Report Date: 11/17/20092.Quality AssuranceNational Accreditation and Management Institute(FBC Organization #: QUA 1789)3.PVC Material CertificationMiami‐Dade Building Code Compliance OfficeNOA# 11‐0830.09Hermes F. Norero, P.E.Florida No. 73778Page 3 of 5

BUILDING DROPSFL#: 14090-R1Date: 03/28/2012Report No: 1968A Perfect Solution in Every DropCertificate of Authorization: 29578Installation:1. Approved anchor types and substrates are as follows:Through Frame Installation:A. For concrete or masonry substrate where one by (1X), non‐structural, wood bucking isemployed, use 3/16” diameter ITW Tapcon type concrete screw anchors of sufficientlength to achieve minimum embedment of 1.75” into concrete or masonry.B. For concrete or masonry substrate where wood bucking is NOT employed, use 3/16”diameter ITW Tapcon type concrete screw anchors of sufficient length to achieveminimum embedment of 1.75” into concrete or masonry.C. For steel substrate, use #10 Tek Screw type steel frame anchors of sufficient length toachieve minimum embedment of 3 threads penetration beyond steel framing.Refer to Installation Instructions (JPAV8200 NCTL210‐3626‐1) for anchor spacing and more details ofthe installation requirements.Design Pressure:Design PressurePositiveNegative50 PSF55 PSFHermes F. Norero, P.E.Florida No. 73778Page 4 of 5

BUILDING DROPSFL#: 14090-R1Date: 03/28/2012Report No: 1968A Perfect Solution in Every DropCertificate of Authorization: 29578Installation MethodJELD-WEN, inc.Premium Atlantic Vinyl Horizontal Slider Window74”x62”Hermes F. Norero, P.E.Florida No. 73778Page 5 of 5

Florida No. 73778 BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Product Evaluation Report of JELD-WEN, inc. Premium Atlantic Vinyl Horizontal Slider Window (PAV 8200) for Florida Product Approval FL# 14090-R1 Report No. 1968 Florida Building Code 2010 Per Rule 9N-3