ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU) Date 12 .

Transcription

ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU)2.2.3.1226/02/2018AHUSEL V.BSKTECHNICAL DATARev. Date12/03/201803/05/2018Proj.Trace No223332495HEAT ECOVERY UNIT-ECOAHU-1JUPITER 12 X 24DateProject NoProject NameAHU NameAHU Model1/5RIGHT VIEWTOP VIEWGENERAL SPECIFICATIONSSupply Air FlowReturn Air FlowFrameDimensions (mm)6,000 m³/h6,000 m³/h25 steel profileSupply Air VelocityReturn Air VelocityInsulation MaterialA2608 x H2723 x L4789Total Weight0.85 m/s0.85 m/sRockwool 70 kg/m³2,966 kgCoil Air VelocityAir DensityInsulation ThicknessBase Height / Installation1.3255 kg/m³50 mm150 mm / OutsideDesign Outdoor Temp.Mixing RatioOutside Sheet MaterialAbsorbed Power-7.7 C / 25.8 C(Odense)% 0.000.9 mm Painted Galvanize3.41 kWTotal Heating CapacityTotal Cooling CapacityInside Sheet MaterialMotor Power(Vant/Asp)0.9 mm GalvanizeSpecific Fan Power(SFP Total)ErP ComplianceErP CodeReal Unit CAL Class -400 PaReal Unit CAL Class 400 Pa0.32 kW/(m³/s)2016 & 2018NRVU - BVUL3L3NOISE LEVELSOUND POWER LEVEL (dB)Frequency Hz125Airborne Sound Power Level51.862.853.070.250.6Supply Air Outlet Induct Sound Power LevelSupply Air Inlet Induct Sound Power LevelReturn Air Outlet Induct Sound Power LevelReturn Air Inlet Induct Sound Power Manometer Pressure GaugeModelJUPITERCS CAL Class CAL Class FBLClass -400 Pa 400 Pa ation at125 Hz [dB]Casingaccousticalinsulation at250 Hz [dB]T2TB218.427.2www.bskhavalandirma.com.trOffice Tel: 90 216 669 09 70info@bskhavalandirma.com.trOffice Fax: 90 216 669 09 72Designer:Gönül usticalaccousticalaccousticalaccousticalinsulation at insulation at insulation at insulation at insulation at500 Hz [dB] 1000 Hz [dB] 2000 Hz [dB] 4000 Hz [dB] 8000 Hz [dB]30.135.4Factory Tel:Factory Fax:33.336.543.9 90 216 669 09 70 90 216 669 09 7203.05.2018

ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU)2.2.3.1226/02/2018AHUSEL V.BSKTECHNICAL DATARev. Date12/03/201803/05/2018Proj.Trace No223332495HEAT ECOVERY UNIT-ECOAHU-1JUPITER 12 X 24DateProject NoProject NameAHU NameAHU Model2/5FRESH AIR CONNECTIONConnection TypeAutomationPressure DropGear DamperAutomatic10 PaAirflowDimensionsAir Velocity6,000 m³/hA 2082 mm x H 210 mm3.81 m/sConnection TypeAutomationPressure DropFlangeAutomatic10 PaAirflowDimensionsAir Velocity6,000 m³/hA 2082 mm x H 210 mm3.81 m/sConnection TypeAutomationPressure DropGear DamperAutomatic10 PaAirflowDimensionsAir Velocity6,000 m³/hA 2082 mm x H 210 mm3.81 m/sSUPPLY CONNECTIONRETURN CONNECTIONEXHAUST CONNECTIONConnection TypeAutomationPressure DropFlangeAutomatic10 PaAirflowDimensionsAir Velocity6,000 m³/hA 2082 mm x H 210 mm3.81 m/sFILTER (M3)Filter TypeInitial / Final / Design P.DropAir VelocitySize/Quantity/EC*Size/Quantity/EC*G-4 Panel16 Pa / 160 Pa / 88 Pa0.96 m/s592x592x50/3/NA592x287x50/4/NAFilter TypeInitial / Final / Design P.DropAir VelocitySize/Quantity/EC*Size/Quantity/EC*F-7 Bag25 Pa / 360 Pa / 192 Pa0.96 Section Weight508 kgSize/Quantity/EC*Spare Filter* Filter Energy Performance; preferably energy classificationACCESSORIESManometer Pressure GaugeROTARY HEAT RECOVERY (M1)ModelRRU-P-E20-1825/1825-1700Fresh AirExhaustAirflow6,000 m³/h6,000 m³/hAir Vel.1.33 m/s1.48 56Air Inlet / OutletInletFresh AirOutletInlet428 ensation Pan1Exhau58ExhaustOutlet15WinterFresh AirInletSection Weight66.19 kWExhaus FreshP.D (Pa)SummerQuantityWinter-2.94 kWFreshRpmOACFEATR (%)0.8519.780.44Frequency Inverter* Efficiency at balanced flow* OACF: Outdoor Air Correction Factor, EATR: Exhaust Air Transfer Ratiowww.bskhavalandirma.com.trOffice Tel: 90 216 669 09 70info@bskhavalandirma.com.trOffice Fax: 90 216 669 09 72Designer:Gönül ÜnalFactory Tel:Factory Fax: 90 216 669 09 70 90 216 669 09 7203.05.2018

ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU)AHUSEL V.BSKTECHNICAL DATARev. Date12/03/201803/05/2018Proj.Trace No223332495HEAT ECOVERY UNIT-ECOAHU-1JUPITER 12 X 24DateProject NoProject NameAHU NameAHU Model2.2.3.1226/02/20183/5ACCESSORIESSUPPLY FAN (M4)AirflowFan ModelQuantitySection Weight6,000 m³/hEBM Papst-K3G355BC92021420 kgInternal Static PressureMotor P./Volt./Pha./Freq.350 Pa3P/400V/50-60HzExternal Static Pressure250 PaTotal Static Pressure600 PaTotal Pressure701 PaTotal / Static Efficiency62.39 / 53.39 %Shaft / Absorbed PowerAbsorbed Pow.With VFD1.87 / 1.87 kW1.87 kWFan SpeedSound Power Level (dB)2736 rpm(Max.2800 rpm)Hz12525069.070.4SPLa - Inlet SideSPLm - Outlet Side79.780.6Specific Fan Power(SFPe int)Air Density0.07 kW/(m³/s)Backup Motor0* The fan system effect is taken into account in the fan performanceBackup Fan500100078.776.882.886.61.2000 83.4 dBA90.4 dBA* The fan calculated for wet conditions* Sfp is calculated based on clean filter & dry coil conditionsACCESSORIESSILENCER (M8)AirflowSound Absorbtion (250 Hz)Pressure DropSilencer ThicknessSilencer MaterialSection Weight6,000 m³/h22 dB3 Pa200 mmRockwool ( 52 kg/m³ ) 50 m302 kgSilencer Code200d 100s 7n 1000L 850H 2127AACCESSORIESEMPTY SECTION (M9)Airflow6,000 m³/hPressure DropSection Weight0 Pa153 kgACCESSORIESwww.bskhavalandirma.com.trOffice Tel: 90 216 669 09 70info@bskhavalandirma.com.trOffice Fax: 90 216 669 09 72Designer:Gönül ÜnalFactory Tel:Factory Fax: 90 216 669 09 70 90 216 669 09 7203.05.2018

ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU)AHUSEL V.BSKTECHNICAL DATARev. Date12/03/201803/05/2018Proj.Trace No223332495HEAT ECOVERY UNIT-ECOAHU-1JUPITER 12 X 24DateProject NoProject NameAHU NameAHU Model2.2.3.1226/02/20184/5EXHAUST FAN (M5)AirflowFan ModelQuantitySection Weight6,000 m³/hEBM Papst-K3G355BC92021465 kgInternal Static PressureMotor P./Volt./Pha./Freq.167 Pa3P/400V/50-60HzExternal Static Pressure250 PaTotal Static Pressure417 PaTotal Pressure518 PaTotal / Static Efficiency56.28 / 45.30 %Shaft / Absorbed PowerAbsorbed Pow.With VFD1.53 / 1.53 kW1.53 kWFan SpeedSound Power Level (dB)2594 rpm(Max.2800 rpm)Hz125SPLa - Inlet Side25069.270.2SPLm - Outlet Side78.680.2Specific Fan Power(SFPe int)Air Density0.03 kW/(m³/s)Backup Motor0* The fan system effect is taken into account in the fan performanceBackup Fan500100079.076.482.586.31.2000 83.4 dBA90.2 dBA* The fan calculated for wet conditions* Sfp is calculated based on clean filter & dry coil conditionsACCESSORIESEMPTY SECTION (M7)AirflowPressure DropSection Weight6,000 m³/h0 Pa155 kgACCESSORIESSILENCER (M6)AirflowSound Absorbtion (250 Hz)Pressure DropSilencer ThicknessSilencer MaterialSection Weight6,000 m³/h22 dB3 Pa200 mmRockwool ( 52 kg/m³ ) 50 m281 kgSilencer Code200d 100s 7n 1000L 850H 2127AACCESSORIESFILTER (M2)Filter TypeInitial / Final / Design P.DropAir VelocitySize/Quantity/EC*Size/Quantity/EC*G-4 Panel16 Pa / 160 Pa / 88 Pa0.96 m/s592x592x50/3/NA592x287x50/4/NAFilter TypeInitial / Final / Design P.DropAir ntity/EC*Section Weight254 kgSize/Quantity/EC*Spare Filter* Filter Energy Performance; preferably energy classificationwww.bskhavalandirma.com.trOffice Tel: 90 216 669 09 70info@bskhavalandirma.com.trOffice Fax: 90 216 669 09 72Designer:Gönül ÜnalFactory Tel:Factory Fax: 90 216 669 09 70 90 216 669 09 7203.05.2018

ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU)AHUSEL V.BSK2.2.3.1226/02/20185/5DateProject NoProject NameAHU NameAHU ModelTECHNICAL DATARev. Date12/03/201803/05/2018Proj.Trace No223332495HEAT ECOVERY UNIT-ECOAHU-1JUPITER 12 X 24ACCESSORIESManometer Pressure GaugeABCDEFGHIJKLMNOPQRSEcodesign Requirements TableValueJUPITER 25Product2016 & 2018ErpBSK Havalandırma Ekipmanları A.Ş.ManufacturerJUPITER 12 X 24Model IdentifierNRVU - BVUErP CodeVariable Speed Drive Variable Speed DriveType Of Drive(VSD)(VSD)Type Of HRSRotaryHRS DamperExists80.82 %Thermal Efficiency of HRS1.67 m³/s1.67 m³/sNominal Flow Rate1.87 kW1.53 kWEffective Electrical Power Input578 W/(m³/s)612 W/(m³/s)SPFInt0.85 m/s0.85 m/sFace Velocity250 Pa250 PaNominal External Drop ps, Ext350 Pa167 PaInternal Pressure Drop ps, Int101 Pa101 PaAdditional Pressure Drop ps, Add53.39 %45.30 %Static Fan Efficiency EC327/20110.85 %Declared Maximum Ext./Int. Leakage RateBNAEnergy Performance Of FiltersManometer Pressure Manometer PressureDescription Of Visual Filter WarningGaugeGauge90.4 dB90.2 dBCasing Sound Power Level (Lwa)www.bskhavalandirma.com.trInternet Address Of Instructionswww.bskhavalandirma.com.trOffice Tel: 90 216 669 09 70info@bskhavalandirma.com.trOffice Fax: 90 216 669 09 72Designer:Gönül ÜnalFactory Tel:Factory Fax:20162018Required RequiredRequired Required 67 % 73 % 1204 934Required 90 216 669 09 70 90 216 669 09 7203.05.2018

ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU) AHUSEL V. 2.2.3.12 26/02/2018 BSK 3/5 TECHNICAL DATA Date 12/03/2018 Rev. Date 03/05/2018 Project No 2233 Proj.Trace No 32495 Project Name HEAT ECOVERY UNIT-ECO AHU Name AHU-1 AHU Model JUPITER 12 X 24 ACCESSORIES Airflow 6,000 m³/h