NetApp Hardware Universe – RC-0036-0708 – Side A – 07-22 .

Transcription

NetApp Hardware Universe – RC-0036-0708 – Side A – 07-22-2008System Cabinet42U System CabinetDimensionsHeightCabinet ClosedWeight78.7 in. (200 cm)Rail Load CapacityClearance125 lb. (56.7 717171616U1616161515U1515151414U141413U13134230 in. (76.3 cm)37.4 in. (95 cm)Width23.6 in. (60 cm)Rack SpaceEmpty Weight275 lb. (124.7 kg)Loaded Weight1500 lb. (680 kg)Side (Optional)Top24 in. (61 cm)12 in. (30 cm)73.5 in. (186.7 cm)3734System Cabinet ConfigurationsConfiguration30-Amp Single-Phase 2x PDU20-Amp Single-Phase PDU20A (derated to 16A in U.S.)200-240V AC, 50/60Hz x 4Power RequirementPower Distribution Units (PDU)30A (derated to 24A in U.S.)200-240V AC, 50/60Hz x 24x (mounted two per side)2x (mounted one unit per side)30-Amp Single-Phase 4x PDU30A (derated to 24A in U.S.)200-240V AC, 50/60Hz x 44x (mounted two per side)Power Inlet (U.S.)IEC320-C20 x 4(Power cords hard-wired to PDU)(Power cords hard-wired to PDU)Power Inlet (Intl)IEC320-C20 x 4(Power cords hard-wired to PDU)(Power cords hard-wired to PDU)Part NumbersPower Outlets (per PDU)IEC320-C13 x 8IEC320-C13 x 16IEC320-C13 x 8Base Cabinet (U.S.)X871A-R6 (20A PDU x 4)X8730A-R6 (30A PDU x 2)X8730B-R6 (30A PDU x 4)Base Cabinet (Intl)(same as U.S.)X8731A (30A PDU x 2)X8731B (30A PDU x 4)PDU Only (U.S.)X8711-R6 (20A PDU x 1)PDU Only (Intl)Power Cord (U.S.)X8712A-R6 (30A PDU x 1)X8712B-R6 (30A PDU x 1)(same as U.S.)X8713A-R6 (30A PDU x 1)X8713B-R6 (30A PDU x 1)X875A-R6 (NEMA L6-20 x 4)(NEMA L6-30 hard-wired to PDU)(NEMA L6-30 hard-wired to PDU)Power Cord (Intl)X875B-R6 (IEC309-16A x 4)(IEC309-30A hard-wired to PDU)(IEC309-30A hard-wired to PDU)Cabinet Closed4140DepthCabinet 72F72F72F72F12U12121111U111110U101072FPower Cord (Aus/NZ)X875C-R6 (AS/NZS3123-20 x 4)--17.1 per PDU25.5 per PDU17.2 per PDUInput Current Actual 88U0887U07772F3,373 total per PDUInput Power Actual (Watts)Thermal Dissipation (BTU/hr)5,460 total per PDU11,510 per PDU18,629 per PDU3,373 total per PDU11,510 per PDUNotesIEC320C1330A PDU uses two 8-outlet strips daisychained with hard-wired input cables.NEMAL6-20IEC32016A72F72F72F72F72F72F72F1.06 in.26.9 mm1.22 in.31 mm1.22 in.3.1 cm.1.84 in.46.7 72F72F72F72F72F72F72FPower DistributionIEC320-C13 (female) to IEC320-C14 (male)AZ/NZS3123-2027 in. Power CableX800-42U-R648 in. Power CableX1558A-R61.87 in.47.5 mmSystem Cabinet Kits and Parts3.07 in.78 mmIEC320C1972FU06IEC32030ANEMAL6-3072F61.02 in.25.9 mm1.56 in.39.6 mmIEC320C14Because there are two PDUs per side,instead of one, the capacity is doublethe amount, although the PDUs must beconnected to separate 30A branchcircuits.72F672FBecause there are two PDUs per side,instead of one, the capacity is doublethe amount, although the PDUs must beconnected to separate 20A branchcircuits.72F72F3972F974172F72F121042Rail KitX877-R61U Blank PanelX8776-R6Bolt-Down KitX878-R63U Blank PanelX8777-R6Interconnect KitX879-R6Universal 4-Post Rack Mount Kit2.42 in.61.5 mmPlease recycle after use. Feedback and questions can be sent to xdl-hardwareuniverse@netapp.com.X5515A-R6

NetApp Hardware Universe – RC-0036-0708 – Side B – 07-22-2008Common CablesHA Pair Interconnect Cables and ConnectorsFibre Channel Cables and ConnectorsMTPInfiniband 4X (IB4X)CableSFPIB4X-MTPConverter0.49 in.(12.5 mm)0.53 in.(13.7 mm)0.53 in.(13.7 mm)HSSDC20.98 in.(24.9 mm)Part No.Optical Cables and ConnectorsLCSFPTransceiver0.53 in.(13.7 mm)BeginEndLengthQuantityX1943A-R6InfiniBand 4XInfiniBand 4X.5m2X1940A-R6InfiniBand 4XInfiniBand 4X2m2X1941A-R6InfiniBand 4XInfiniBand 4X5m2X1942A-R6InfiniBand 4XInfiniBand 4X10m2X1949A-R5InfiniBand 4XMTPCu-Op 51A-R6MTPSC (Op)30m10.46 in.11.8 mmDB90.98 in.(24.9 mm)SCPart No.1.25 in.(31.8 mm)0.54 in.(13.8 mm)Part No.BeginEndLengthQuantityX6529-R6SFPLC (Op)Transceiver (2Gb)1X6539-R6SFPLC (Op)Transceiver (4Gb)1X6530-R6SFPSFP.5m (4/2/1Gb)1X6532-R6SFPSFP3m (2/1Gb only)1SFPSFP5m (4/2/1Gb Op)1ST0.91 in.23 mm0.39 in.9.8 CSC30m1X6524-R62 x LC2 x 1X6537-R6LCLC30m1X6523-R62 x LC2 x SC2m1X1952A-R6MTPST (Op)30m1X6556-R6X1953A-R6MTPLC 5m1X6546-R6LCSC30m1SFPHSSDC23m1X1954A-R6MTPFC (Op)30m1X6531-R6X1955A-R6MTPMT-RJ (Op)30m1X6533-R6SCSI Cables and ConnectorsHA Pair NotesHA pair configuration means two controllers - both actively serving data - are connected for automaticfailover protection. The following interconnect options are applicable to HA pair configurations usingNVRAM5 and NVRAM6 adapters:Console Cables and ConnectorsRJ45DB9VHDCIHD-68.5m to 10m – Copper InfiniBand interconnect cables (standard)NetApp part: X1943A-R6 (.5m), X1940A-R6 (2m), X1941A-R6 (5m), or X1942A-R6 (10m)5m to 30m – Optical interconnect using MTP ribbon cables (supplier NetApp)NetApp part: X1949A-R6 (Cu-to-Op converter)NetApp part: X1945A-R6 (5m) or X1946-R6 (30m)30m to 300m – Optical interconnect using MTP ribbon cables (suppliers NetApp and Fujikura)NetApp part: X1949A-R6 (Cu-to-Op converter)Fujikura part: CBPE4-497-XXX, where XXX designates length in metersExample: 300 meter MTP 50/125 Plenum Cable 500Mhz/KM is CBPE4-497-3002.6 in.(66 mm)1.65 in.(42 mm)Part No.BeginEndLengthQuantityX6513-R6HD-68VHDCI2m11.25 in.(31.8 mm)0.49 in.(12.7 mm)Part No.BeginEndLengthQuantityX881-R6DB9RJ45M Dongle1300m to 500m – Optical interconnect using MTP ribbon cables (suppliers NetApp and Fujikura)NetApp part: X1949A-R6 (Cu-to-Op converter)Fujikura part: CBPE4-507-XXX, where XXX designates length in metersExample: 500 meter MTP 50/125 Plenum Cable 2000Mhz/KM is CBPE4-507-500NOTE: In order to achieve the maximum 500 meter distance between controllers in a HA pair, theinterconnect cable must be a direct point-to-point connection with no intermediate device between them(such as patch panel).HA configurations that must go through a patch panel can use the following part numbers in conjunctionwith the X1949A-R6 Cu-to-Op 55A-R6- SC termination- ST termination- LC termination- FC (Op) termination- MT-RJ terminationTerms and AbbreviationsBTU – British Thermal UnitCu – Copper ConnectorFC – Fibre ChannelFC (Op) – Ferrule ConnectorHSSDC – High-Speed Serial Data ConnectorIB – InfiniBandIB4X – InfiniBand 4XLC – Lucent ConnectorMTP – Mechanical Transfer Pull-OffMT-RJ – Mechanical Transfer Registered JackOp – Optical ConnectorPDU – Power Distribution UnitSC – Subscriber ConnectorSFP – Small Form-Factor PluggableST – Straight Tip ConnectorVHDCI – Very High Density Cable Interconnect 2008 NetApp. All rights reserved. Specifications are subject to change without notice. NetApp, the NetApp logo, Go further,faster, and Data ONTAP, are trademarks or registered trademarks of NetApp, Inc. in the United States and/or other countries. Allother brands or products are trademarks or registered trademarks of their respective holders and should be treated as such.RC-0036-0708This document is subject to change without notice. Be sure to cross-reference the NOW System Configuration Guide at http://now.netapp.com for the most current information. NetApp employees and partners can check the NetApp 1Stop site at http://www.netapp1stop.com for updates. NetApp customers should check with their account teams for updates.This document is chartered under the NetApp Systems Engineering Program Office.Please recycle after use. Feedback and questions can be sent to xdl-hardwareuniverse@netapp.com.

NetApp Hardware Universe – RC-0032-0708 – Side A – 07-22-2008Fabric-Attached Storage (FAS)Model TB336TB84TB104TB68TB16TB4TBAggregate/VolMaximum Size216TB16TB16TB16TB16TB16TB16TB16TB8TB8TB2TBMax Back-EndFC Loops1410106864221-Max ExpansionDisk Shelves84606030362412643-1,17684084042050433616884 (external)56 (external)56 (14 int 42 ext)14 (internal)-------20 (internal)12 (internal)--SATA1,176840840420504336168 4104 (20 int 84 ext)68 (12 int 56 ext)28 (external)-Height12U / 6U12U / 6U6U / 6U6U / 6U6U / 3U6U / 3U6U / 3U4U / 4U2U / 2U3U / 3U- / 3U242 lb. (109.6 kg)121 lb. (54.8 kg)242 lb. (109.6 kg)121 lb. (54.8 kg)122 lb. (55.3 kg)95 lb. (43.1 kg)122 lb. (55.3 kg)95 lb. (43.1 kg)150 lb. (68 kg)75 lb. (34 kg)150 lb. (68 kg)75 lb. (34 kg)150 lb. (68 kg)75 lb. (34 kg)110 lb. (50 kg)with drives60 lb. (27.2 kg)with drives77 lb. (35 kg)with drives77 lb. (35 kg)with drives100-120V 11.2A200-240V 5.8A100-120V 10.8A200-240V 5.6A100-120V 8.1A200-240V 4A100-120V 5.9A200-240V 2.9A100-120V 7.4A200-240V 4.2A100-120V 6.8A200-240V 3.8A100-120V 4.8A200-240V 2.8A100-120V 5.7A200-240V 2.9A100-120V 4.1A200-240V 2.2A100-120V 4A200-240V 2A100-120V 4A200-240V 2A3,740 BTU/hr1,870 BTU/hr3,624 BTU/hr1,812 BTU/hr2,761 BTU/hr1,602 BTU/hr2,026 BTU/hr1,272 BTU/hr2,466 BTU/hr1,233 BTU/hr2,304 BTU/hr1,152 BTU/hr1,610 BTU/hr805 BTU/hr2,247 BTU/hr1,988 BTU/hr1,587 BTU/hr1,298 BTU/hr1,279 BTU/hr1,178 BTU/hrFront ViewEnvironmentalHA Pair/Single ControllerMax DriveQuantitySystem CapacityRaw Maximum1FCSAS(HA/Single)Weight(HA/Single)AC Power(HA 22/12/12/12/1(HA/Single)64-bit dual-core64-bit64-bit dual-core64-bit dual-core64-bit dual-core64-bit32-bit32-bit32-bit64-bit164-bit64GB / 32GB32GB / 16GB32GB / 16GB8GB / 4GB16GB / 8GB8GB / 4GB4GB / 2GB4GB / 2GB2GB / 1GB2GB / 1GB512MB4GB / 2GB1GB / 512MB4GB / 2GB1GB / 512MB1GB / 512MB1GB / 512MB256MB / 128MB256MB / 128MB64MBonboard1GB / 512MB512MB / 256MBonboardNVMEMNVMEMNVMEMNVMEM10 / 5 (PCIe)6 / 3 (PCI-X)10 / 5 (PCIe)6 / 3 (PCI-X)8 / 4 (PCIe)8 / 4 (PCIe)6 / 3 (PCIe)6 / 3 (PCIe)6 / 3 (PCI-X)2 / 1 (PCIe)---12 / 6GbE RJ4512 / 6GbE RJ454/2GbE RJ454/2GbE RJ458/4GbE RJ458/4GbE RJ458/4GbE RJ454/2GbE RJ454/2GbE RJ454/2GbE RJ452GbE RJ4516 / 84Gb SFP616 / 84Gb SFP68/44Gb SFP68/44Gb SFP68/44Gb SFP68/44Gb SFP68/42Gb SFP74/24Gb SFP64/24Gb SFP64/22Gb SFP712Gb 17.2.2L17.2.2L16.56.4.3HA Pair/Single ControllerPlatform SpecificationsRAM(HA/Single)NVRAM(HA/Single)PCI Slots(HA/Single)Ethernet(HA/Single)FC Ports(HA/Single)Data ONTAP (Min Release)Please recycle after use. Feedback and questions can be sent to xdl-hardwareuniverse@netapp.com.

NetApp Hardware Universe – RC-0032-0708 – Side B – 07-22-2008NetApp S FamilyModelS550S300NetApp SA SystemsSA600SA300SA200Front View12TB6TB1,176TB504TB104TBAggregate/VolMaximum Size212TB6TB16TB16TB16TBMax Back-EndFC Loops--1482Max ExpansionDisk Shelves--84366FC--1,17650484 (external)SAS----20 (internal)12 (internal)8 (internal)1,176504104 (20 int 84 ext)12U / 6U6U / 3U4U / 4UMax DriveQuantitySystem CapacityRaw Maximum1SATATerms and AbbreviationsBTU – British Thermal UnitCu – Copper ConnectorFAS – Fabric-Attached StorageFC – Fibre ChannelGbE – Gibabit EthernetHA – High AvailabilityNVRAM – Non-Volatile RAMOp – Optical ConnectorPSU – Power Supply UnitSAS – Serial-attached SCSISATA – Serial ATASFE – S Family EditionSFP – Small Form-Factor PluggableVAC – Volts Alternating CurrentNotes1EnvironmentalHA Pair/Single ControllerHeight(HA/Single)Weight(HA/Single)AC Power(HA only)Thermal3(HA/Single)HA Pair/Single Controller41.88 lb. (19 kg)with drives242 lb. (109.6 kg)121 lb. (54.8 kg)150 lb. (68 kg)75 lb. (34 kg)110 lb. (50 kg)with drives100-120V 9A200-240V 4.5A100-120V 6A200-240V 3A100-120V 11.2A200-240V 5.8A100-120V 7.4A200-240V 4.2A100-120V 5.7A200-240V 2.9A1,706 BTU/hr1,706 BTU/hr3,740 BTU/hr1,870 BTU/hr2,466 BTU/hr1,233 BTU/hr2,247 BTU/hr1,988 )PCI Slots(HA/Single)Ethernet(HA/Single)FC Ports(HA/Single)- / 4U52 lb. (35.8 kg)with drivesProcessorRAMPlatform Specifications- / 2U52GB256MB11GB128MBNVMEM8/44/22/164-bit dual-core64-bit dual-core32-bit64GB / 32GB16GB / 8GB4GB / 2GB4GB / 2GB1GB / 512MB512MB / 256MBNVMEM2 (PCI-X)-10 / 5 (PCIe)6 / 3 (PCI-X)6 / 3 (PCIe)2 / 1 (PCIe)2GbE RJ454GbE RJ4512 / 6GbE RJ458/4GbE RJ454/2GbE RJ45--16 / 84Gb SFP68/44Gb SFP64/24Gb SFP67.2.1 SFE7.2.1 SFE7.2.57.2.57.2.5System capacity is calculated using base 10 arithmetic (i.e. 1TB 1,000,000,000,000 bytes) andis derived based on the type, size, and number of drives.Maximum volume/aggregate size is calculated using base 2 arithmetic (1TB 240 bytes).3The thermal dissipation values shown are based on typical system values at 100-120V inputvoltage. Please refer to the Site Requirements Guide on the NOW site for worst-case thermaldissipation values.4Available with all drive types 500GB. The maximum number of 750GB disk drives is 112. Themaximum number of 1TB disk drives is 84.5A single NetApp S300 system is roughly 8.8" (22mm) wide and only occupies half of a standard19" rack horizontally. It is possible to rack two S300 systems side by side in a standard 19" rack.6Autosensing ports: 1, 2, 4Gb.7Autosensing ports: 1, 2Gb.2 2008 NetApp. All rights reserved. Specifications are subject to

NetApp employees and partners can check the NetApp 1Stop site at http://www.netapp1stop.com for updates. NetApp customers should check with their account teams for updates. This document is chartered under the NetApp Systems Engineering Program Office. NetApp Hardware Universe – RC-0037-0708 – Side A – 07-22-2008.File Size: 2MBPage Count: 12