Common Work Results For Plumbing

Transcription

DESIGN REQUIREMENTSPREFERRED MANUFACTURERSGENERAL INFORMATION1.1 Manufacturers on this list fall into four categories:a. Preferred Manufacturer: Approved manufacturers for use on Columbia Universityprojects.b. Conditional Approval: Manufacturers approved for certain projects. Contact ColumbiaUniversity Facilities for approval to use on new projects.c. Under Consideration: Manufacturers being evaluated. Do not specify unless approved inwriting from Columbia University Facilities.d. Hold/Removed: Manufacturers have been removed, generally for poor performance orunresolved issues on past projects. These manufacturers should not be specified for anyproject.This list is intended to cover major equipment vendors listed in the Specification sections.Often, ancillary vendors used to construct the equipment are listed within thespecification sections (e.g. pipe and duct sealants, firestoppig, etc.). This list does notabsolve the Engineer of Record from reading and complying with the requirements setforth in the Specification Sections and sound engineering practices.1.2 Corrections/SubstitutionsIf there are errors in model numbers or manufacturers listed, or if a model is no longeravailable, notify Columbia University Facilities in writing for a clarification. A responseregarding the Correction or Substitution will be provided.LAST REVISED:JUNE 1 2011

DESIGN REQUIREMENTSLISTING OF PREFERRED MANUFACTURERS2.1Architectural Section Product/Equipment Listinga. 07 52 00 - Modified Bitumous Membrane Roofing1. Siplast - Preferred Manufacturerb. 08 52 00 – Wood Windows1. Artistic Doors and Windows; 10 S. Inman Avenue, Avenel, NJ 07001; Contact: GuyCichy 732.726.9400; 800.278.36672. J.S. Benson Woodworking & Design, LLC; 118 Birge Street, Brattleboro, VT 05301;Contact: 802.254.3515; 800.339.35153. Tradewood Windows; 75A Lake Road, Suite-164, Congers, NY 10920; Contact: JosephValentino 845.675.78254. The Woodstone Company; 1164 North Main Street, North Walpole, NH 03609;Contact: Mike Robarge 800.682.82235. Zeluck Architectural Wood Windows and Doors; 5300 Kings Highway, Brooklyn, NY11234; Contact: 800.233.0101c. 09 30 13 – Ceramic Tiling1. American Marazzi Tile, Inc.2. American Olean; Div. of Dal-Tile International Corp.3. Crossville Ceramics Company, L.P.4. Daltile; Div. of Dal-Tile International Inc.5. Lone Star Ceramics Company.6. Monarch Tile, Inc.LAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTS7. Summitville Tiles, Inc.d. 09 51 13 – Acoustical Panel Ceilings1. Armstrong World Industries, Inc2. USG Corporation.e. 09 65 19 – Resilient Tile Flooring1. Armstrong2. Azrock3. Forbo4. Mannington Commerciale. 09 67 23 - Resinous Flooring1. Dex-O-Tex2. Dura-Shield3. Sika-Flexf. 09 68 16 – Sheet Carpeting1. Patcraft Commercial2. Bigelow Commercial3. Mannington Commercial4. Cambridge Commercial5. Mohawk Commercial6. Interface floor Commercialg. 09 90 00 – Painting1. Benjamin Mooreh. 10 11 00 – Visual Display BoardsLAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTS1. AARCO Products, Inc.2. Allaincewall Corp.3. Claridge Products and Equipment, Inc.4. Greensteel, Inc.5. Lemco, Inc.6. Nelson Adams Company.i.10 21 13 – Toilet Compartments1. Accurate Partitions Corp.2. All American Metal Corp.3. American Sanitary Partition Corp.4. Ampco Products, Inc.5. Flush-Metal Partition Corp.6. General Partition Mtg. Corp.7. Global Steel Products Corp.8. Knickerbocker Partition Corp.9. Lambaton-University Metal Products.10. Metpar Steel Products Corp.11. The Mills Co.12. Monarch Toilet Partitions, Inc13. Sanymetal Products Co.14. Weis/Robert Partitions, Inc.j.10 26 13 – Corner Guards1. Arden Architectural Specialties, Inc.2. InPro Corporation3. Pawling Corporationk. 10 28 13 – Toilet Accessories1. Kimberly Clarke2. BobrickLAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSl.10 44 00 – Fire Protection Accessories1. Ansul Inc.2. Larsen’s Manufacturing Co.3. Encon Safety Products3.1Mechanical Section Equipment Listinga. 23 05 00 - Chilled Water System Overview1. No Manufacturers under this section.b. 23 05 03 - Pipes and Tubes for HVAC Piping and Equipment1. No Manufacturers under this section.c. 23 05 16 - Expansion Joints and Loops1. Expansion Joints - Bellow Type (Packless)a) Badger Company Series 300b) Adsco Company2. Expansion Joints - Slip Joint (Packed) For Steam Pipinga) Advanced Thermal Systemsb) Adsco Companyc) Hyspan3. Anchor and Guidesa) Grinnellb) Metraflexd. 23 05 23 - General-Duty Valves for HVAC Piping1. Ball Valves (4" and Smaller)LAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSa) Apollo 70-10X Series (70-20X Series for Solder)b) Jamesbury 351 (341 for Solder)c) Watts 8-6000 Series (8-6000 Series for Solder)2. Drain Valves (Ball)a) Apollo3. Gate Valves (2" and Smaller)a) Milwaukee 1169b) Stockham 8-1244. Gate Valves (2-1/2” and Larger)a) Milwaukee F-2885b) Stockham G-623c) Crane 465-1/25. Globe Valves (2" and Smaller)a) Milwaukee 590Tb) Stockham B-22Tc) Crane 7TF6. Globe Valves (2" and Larger)a) Crane 1517. Butterfly Valves (High Performance)a) Jamesbury HP 815L - Preferred Manufacturerb) Keystone K Lok8. Plug Valves (2” and 3”)a) Nordstrom wrench-operatedLAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTS9. Plug Valves (4” and Larger)a) Nordstrom worm gear operated10. Swing Check Valves (2” and Smaller)a) Milwaukeeb) Stockham B-309/319c) Crane T/S-43311. Swing Check Valves (2” and Larger)a) Milwaukee F-2974b) Stockham G-931c) Crane 37312. Spring Check Valves (2” and Smaller)a) Mueller 105M-BP13. Spring Check Valves (2” and Larger)a) Mueller 105M-AP14. Flow Control Valves (2” and Smaller)a) Belimo - Preferred Manufacturerb) Flow Controlc) Johnson Control Inc.15. Flow Control Valves (2-1/2” and Larger)a) Belimo - Preferred Manufacturerb) Flow Control16. Triple Duty ValvesLAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSa) NONE - Triple Duty Valves are NOT to be used on any Columbia University Project,NO exceptions.e. 23 05 29 - Hangers and Supports for Piping and Equipment1. Pipe Hangers, Inserts, Saddles, Beam Clampsa) B-line Systems, Inc.b) Carpenter & Patterson. Inc.c) Grinnell Corp.2. Channel Support Systemsa) B-Line Systems, Inc.b) Grinnell Corp.; Power-Strut Unitc) Thomas & Betts Corp.d) Unistrut Corp.3. Thermal-Hanger Shield Insertsa) Carpenter & Patterson, Inc.b) Pipe Shields, Inc.c) Value Engineered Products, Inc.4. Expansion Shielda) Grinnellb) Hilti, Inc.c) Pipe Shields Inc.5. Pre-Insulated Pipe Supportsa) Pipe Shields, Inc.6. Pre-Insulated Riser Clamps:LAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSa) Pipe Shields, Inc.7. Sleeves - Link Seala) Century Line Sleeve, Thunderline Corp.f. 23 05 53 - Identification for Piping and Equipment1. No Manufacturers under this section.g. 23 05 93 - Testing, Adjusting, and Balancing for HVAC1. No Manufacturers under this section.h. 23 07 00 - Mechanical Insulation1. Pipe Insulation Type A - Calcium Silicatea) Manville, Thermo 122. Pipe Insulation Types B and C - Glass Fibera) Owens-Corning, Evolution Pipe Insulation with ASJb) Knauf - Pipe Insulation With ASJc) Certainteed - Type 500 Snap-on with ASJd) Manville - Micro-Lok 650 With AP-T Plus Jacket3. Pipe Insulation Type D - Foama) Armstrong - Type AP ARMAFLEXb) Nomaco, Inc. - Type THERMA-CEL4. Pipe Insertsa) Grinnellb) B-Line5. PVC Covering (Elbows and Fittings)a) Zeston - Preferred ManufacturerLAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSb) Protoc) Ceel-co6. Pipe Shieldsa) Grinnell Figure 1867. Duct Insulation - Flexible Glass Fibera) Owens-Corning Fiberglass - Foil-faced duct wrap.b) Knauf - Type ECOSE with foil facec) Certainteed – Softouch with foil face8. Duct Insulation - Rigid Glass Fibera) Owens-Corning - Type ASJ-705b) Knauf – Duct board with ECOSEc) Certainteed - Certapro9. High Temperature Applications - Calcium Silicatea) Manvilleb) Industrial Insulation Group10. Tank Enclosures and Accessories - Semi-Rigid Glass Fibera) Owens-Corning - Type 703b) Certainteed – Crimp wrapc) Knauf – Kwik Flexd) Manville - Microflex11. Pump Enclosures - Rigid Glass Fibera) Owens-Corning - Type 705b) Manville - Type 800LAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSc) Certainteed - Certaproi.23 09 00 – Building Automation Systems (BAS)1. Building Automation Systems - Note: BAS selected MUST match existing Building BASif used in renovation work.a) Andoverb) Siemens Building Technologiesj.23 21 16 - Hydronic Piping Specialties and Piping Guidelines1. Manual Air Ventsa) Bell and Gossett - No. 4V - Preferred Manufacturerb) Taco, Inc. - 417c) Armstrong Pumps, Inc. - #722. Automatic Air Ventsa) Bell and Gossett - #107 High Capacity Air Vent - Preferred Manufacturerb) Taco, Inc. - Hy-ventc) Spirax/Sarco - 13WS3. Diaphragm-type Expansion Tanksa) Bell and Gossett – Series B or Series Db) Taco, Inc. - CA Seriesc) Armstrong Pumps, Inc. - Series AX4. Air Separatorsa) Bell and Gossett - Rolairtrolb) Taco, Inc. - Air Separator5. Relief ValvesLAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSa) Bell and Gossettb) Amtrolc) Armstrongd) McDonnell and Miller6. Suction Diffusersa) Bell & Gossettb) Armstrong7. Backflow Preventers - Double Check Typea) Watts No. 709 - Preferred Manufacturerb) Hersey8. Backflow Preventers - Reduced Pressure Typea) Watts 909 - Preferred Manufacturerb) Hersey9. Dielectric Fittings - Union Typea) EPCO with Epconite No.110. Dielectric Fittings - Nipple Typea) ClearFlowb) EPCO11. “Y” Type Strainersa) Sarcob) Armstrongc) Muellerk. 23 09 05 - Meters and GaugesLAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTS1. Thermometersa) Marshb) Trerice - B Seriesc) Weissd) Weksler2. Pressure Gaugesa) Ashcroft - Duraguage Seriesb) Marshc) Weiss - PG Seriesd) Weksler - AAT Seriese) WIKAf) U.S. Gaugeg) Trerice - 500X Series3. Air Flow Gauges (Magnehelic)a) Dwyer4. Test Plugs (Requires University Approval)a) Peterson - Petes Plugb) Wekslerc) Trerice5. Steam Metera) Emco6. Chilled Water Metera) Siemens (Controlotron)LAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSl.23 21 23 - Hydronic Pumps1. In-Line Circulators:a) Armstrong Pumps, Inc.b) Bell & Gossett ITT (Series 60 and 80)c) Grundfos Pumps Corp.2. Compact In-Line Circulatorsa) Armstrong Pumps, Inc.b) Bell & Gossett ITTc) Grundfos Pumps Corp.d) PACO Pumpse) Taco3. Vertical In-line Pumps:a) Armstrong Pumps, Inc.b) Bell & Gossett lITc) Goulds Pumps, Inc.d) Grundfos Pumps Corp.e) PACO Pumpsf) Peerless Pump Co.g) Taco4. Flexible-Coupled, End-Suction Pumps:a) Goulds Pumps, Inc.b) Ingersoll-Dresser Pump Co.c) PACO Pumps.LAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSd) Tacoe) Weil Pump Company, Inc.5. Flexible-Coupled, Double Suction Pumps:a) Bell & Gossett ITTb) Goulds Pumps, Inc.c) Ingersoll-Dresser Pump Co.d) PACO Pumps.e) Peerless Pump Go.f) Tacog) Fairbanks Morse Pump Corp.6. Steam Condensate Pump Units:a) Federal Pump - Preferred Manufacturerb) Bell & Gossett ITTc) Roth Pump Companyd) Sarco Pumps7. Condensate Drainage Pump Units:a) Hartell Div.; Milton Roy Co.b) Little Giant Pump Co.c) Marsh Manufacturing, Inc.m. 23 22 16 - Steam and Condensate Piping Specialties1. Steam Traps - Thermostatica) Spirax/Sarco TA-125, TH-125 - Preferred Manufacturer2. Steam Traps - Float and ThermostaticLAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSa) Spirax/Sarco FT -30 - Preferred Manufacturer3. Steam Traps - Inverted Bucket Trapa) Spirax/Sarco B Series - Preferred Manufacturer4. Air Ventsa) Spirax/Sarco VS206 (steam) - Preferred Manufacturerb) Spirax/Sarco 13WS (condensate) - Preferred Manufacturer5. Vacuum Breakersa) Spirax/Sarco VB14 - Preferred Manufacturer6. Pressure Regulating Valvesa) Leslie - Preferred Manufacturerb) Spence Engineering Co. Type ED7. Safety Shutoff Valvesa) Spenceb) Leslie - Preferred Manufacturer8. Safety Relief Valvesa) O.C. KeckleyBronze Series 40b) Spence EngineeringBronze Series 41c) Spirax/Sarco9. “Y” Type Strainersa) Sarco Typeb) Armstrongc) Muellern. 23 31 00 - HVAC Ducts and CasingsLAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTS1. Flexible Ductworka) Clevaflexb) Thermaflexc) Flexmaster2. Volume Dampers - Single Blade (Rectangular)a) Air Balance AC-111b) Greenheckc) Ruskin MD25 - Preferred Manufacturer3. Volume Dampers - Single Blade (Round)a) Air Balance AC-112b) Greenheck MBDR50c) Ruskin MORS25 - Preferred Manufacturer4. Volume Dampers - Multiple Blade - Note: Opposed Blade Type ONLYa) Air Balance AC-2b) Greenheck MBD-15c) Ruskin - Preferred Manufacturer5. Fire Damper - Fusible Linka) Air Balance Inc. Series D19b) Imperialc) Prefco Products Series 5500d) Ruskin - Preferred Manufacturer6. Smoke Damper - Airflow Bladea) Air Balance Inc. SA 1LAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSb) Greenheck SD33c) Ruskin SD60 - Preferred Manufacturerd) Imperial7. Combination Fire/Smoke Dampera) Ruskin FSD60 - Preferred Manufacturer8. Duct Sealanta) 3M Fastbond 900b) Foster 32-14c) MEI44-52d) Hardcast Sure Grip 404, Hardcast Iron Grip 6019. Louversa) Ruskinb) Arrowc) Air Balance10. Access Doors in Walls and Ceilingsa) Cescob) J L Industriesc) Karpd) Milcor11. Filtersa) AAF Internationalb) Farr Companyc) Flanders Filters, Inc.LAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSd) Koch Filter Corporationo. 23 34 00 - HVAC Fans1. Cabinet and Ceiling Fansa) Cook Gemini Seriesb) Greenheck Model SP, CSP and BCF - Preferred Manufacturerc) Penn Zephyr Series2. Square In-Line Centrifugala) Cook SQI or SQN Seriesb) Greenheck Model SQ or BSQ - Preferred Manufacturerc) Penn Centrex Inliner SX3. Tubular Centrifugala) Greenheck TCS Series - Preferred Manufacturerb) Loren Cook4. Centrifugal Utility Fansa) Greenheckb) Belted Utility Vent Setsc) Loren Cook5. Belted Utility Vent Sets - Laboratory Exhausta) Loren Cookb) Buffalo Air6. Roof/Wall Exhausta) Cook AC SeriesLAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSb) Greenheck Models G, GB and C Series - Preferred Manufacturerc) Penn Domex, Fumex7. Axial Propeller Wall Fana) Cook S Series Wall Ventilatorsb) Greenheck SB and S Series - Preferred Manufacturerc) Penn Breezeway Series8. Vaneaxiala) Greenheck VAB Series - Preferred Manufacturerb) Cook Series VA Seriesp. 23 36 00 - Air Terminal Units1. Air Terminal Unitsa) Anemostatb) Titusc) Environmental Technologiesd) Kruegerq. 23 37 00 - Air Outlets and Inlets1. Directional Ceiling Supply Air Diffuser - Type "A"a) Titus TDC, with AG-65S damper and equalizer gridb) Krueger Series SH, with 5-11 damper and equalizer gridc) Anemostat SD, with DOB or DED damper and equalizer grid2. Fixed Ceiling Supply Air Diffuser - Type "B"a) Titus TMS, with AG-65 damper and equalizer gridb) Krueger Series 1400, with R-11 damper and equalizer gridLAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSc) Anemostat E, with Columbia University-1 damper and equalizer grid3. Perforated Ceiling Supply Air Diffuser - Type "C"a) Titus PAS, with AG-65 damper and equalizer gridb) Krueger Series 1100, with R·11 damper and equalizer gridc) Anemostat PR4. Fixed Ceiling Supply Air Diffuser - Type "D"a) Titus TMS, with AG-65 damper and equalizer gridb) Krueger Series 1400, with R-11 damper and equalizer gridc) Anemostat E, with Columbia University-1 damper and equalizer grid5. Ceiling Supply Air Linear Diffuser - Type "E"a) Titus ML-37, ML-38, or ML-39b) Krueger Series 1500·1600c) Anemostat AL6. Sidewall, Sill, Or Floor Supply Linear Air Diffuser - Type "F"a) Titus CT -480 or CT -481b) Krueger Series 1500·1600c) Anemostat Al7. Fixed Supply Air Register - Type "G"a) Titus 300RS with AG-15 damperb) Krueger 880V with OBD damperc) Anemostat S2VO8. Perforated Ceiling Return Air Diffuser - Type "H"a) Titus PARLAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSb) Krueger Series 1190c) Anemostat 3P9. Ceiling Return Linear Air Diffuser - Type "I"a) Titus ML-37, ML-38, or ML-39b) Krueger Series 1900c) Anemostat SLAD10. Return, Exhaust, Or Transfer Fixed Air Register – Type “J”a) Titus 300RS with AG-15 damperb) Krueger S80H with OBD damperc) Anemostat S30D11. Perforated Return, Exhaust, Or Transfer Air Register - Type “K”a) Titus 8F with AG-35 damperb) Krueger S80P with OPO damper12. Laboratory Perforated - Ceiling Supply and Diffuser - Type OIL"a) Titus Tritec13. Return, Exhaust, Or Transfer Fixed Air Grille - Type “M”a) Titus 350RLb) Krueger S80Hc) Anemostat S3HD14. Return, Exhaust, Or Transfer Perforated Air Grille - Type "N"a) Titus 8Fb) Krueger S80P15. Return, Exhaust, Or Transfer Eggcrate Air Grille - Type "0"LAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSa) Titus 50Pb) Krueger EGC-5c) Anemostat GC516. Filter Return Grille - Type "P"a) Titus 4FFb) Krueger S80P5FF-1c) Anemostat 35HQ17. Ducted HEPA Filter Supply Terminal- Type "Q"a) Flanders Filter Company Model 22.r. 23 57 00 - Heat Exchangers for HVAC1. U- Tube Heat Exchangers (Steam to Water)a) Bell & Gossett ITT - Type 'SU'b) Taco, Inc. - 'Steam to Liquid Heat Exchanger.'2. U-Tube Heat Exchangers (Water to Water)a) Bell & Gossett ITT - Type 'WU'b) Taco, Inc. - 'Liquid to Liquid Heat Exchanger.'3. Plate and Frame Heat Exchangersa) Alfa Lavalb) Tranterc) American Vicarb4. Steam-to-Steam Heat Exchangers (Clean Steam Generators)a) Cemlineb) Patterson-KellyLAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSs. 23 73 00 - Air Handling Units1. Modular AHUsa) Trane Modular Seriesb) Carrierc) Yorkd) McQuay - REMOVED2. Custom AHUsa) Buffalo Air - Preferred Manufacturerb) Climate Craftt. 23 82 00 - Convection Heating and Cooling Units1. Vertical and Ceiling Hung Fan Coil Unitsa) Custom Airb) Yorkc) International Environmental - Preferred Manufacturerd) Trane - REMOVED2. High Rise Style Fan Coil Unitsa) Williamsb) Air Therm3. Fin Tube Radiationa) Dunham-Bush, Inc.b) Sterling Radiator, Div. of Reed National Corp.c) Vulcan Radiator Co.4. ConvectorsLAST REVISED:JUNE 12, 2011

DESIGN REQUIREMENTSa) Airtherm Mfg. Co.b) Dunham-Bush, Inc.c) Sterling Radiator, Div. of Reed National Corp.5. Unit Heatersa) Airtherm Mfg. Co.b) Dunham-Bush, Inc.c) Modine Mfg. Co.d) Sterling Radiator, Div. of Reed National Corp.6. Cabinet Heatersa) Airtherm Mfg. Co.b) Dunham-Bush, Inc.c) McQuay Inc.d) Sterling Radiator, Div. of Reed National Corp.LAST REVISED:JUNE 12, 2011

c. 23 05 16 - Expansion Joints and Loops 1. Expansion Joints - Bellow Type (Packless) a) Badger Company Series 300 b) Adsco Company 2. Expansion Joints - Slip Joint (Packed) For Steam Piping a) Advanced Thermal Sys