Handheld Detection For Any Scenario - AADEE

Transcription

RadEye Selection GuideHandheld Detectionfor Any Scenario

RadEye Product FamilyWith the RadEye Product Family, Thermo Fisher Scientific offers a wide range of advancedhandheld instruments for radiation detection, gamma dose rate measurements and areamonitoring.This guide offers a brief description and technical characteristics for each instrument. Formore detailed technical specifications, please contact your local sales representative or yourappropriate customer service assistant.Americasinfo.eid@thermofisher.comUnited mEurope, Middle East, Africa, ore@thermofisher.comAny nation not m

ContentsApplication Products PageRadEye product family All RadEye 4, 5High sensitivity γ - detection and dose rate measurementRadEye PRD6High sensitivity γ - detection and wide range dose rate measurementRadEye PRD-ER7General purpose γ - dose rate measurement (U.S.)RadEye G, G-108General purpose γ - dose rate measurementRadEye GF, GF-109Dose rate measurement in explosive atmosphere (U.S.)RadEye G-Ex10, 11High range dose rate measurement in explosive atmosphere (U.S.)RadEye GF-Ex10, 11Dose rate measurement in explosive atmosphereRadEye G-10-Ex10, 11High range dose rate measurement in explosive atmosphereRadEye GF-10-Ex10, 11X-ray and γ - survey meter RadEye G20-10 12Wide dose rate, X-ray and γ - survey meter RadEye G20-ER10 12Multi purpose meter for contaminationRadEye B2013, 14, 15Wide range multi purpose meter for dose rate and contaminationRadEye B20-ER13, 14, 15Neutron detection and dose rate measurementRadEye NL16, 17α, β - contamination RadEye AB100 18Survey meter for external GM-detectorsRadEye GX, GX-L19, 20, 21Survey meter for external scintillation detectorsRadEye SX19, 20, 22Survey meter for external proportional detectorsRadEye PX19, 20, 23α, β - portable sample counter RadEye HEC 24, 25Area monitoring RadEye Area Monitor26, 27Wireless radiation detection system for grapple installationRadEye GR28Radiation detection and personal protection kitRadEye Safety Kit29, 30Extensions 31Bluetooth adapter for RadEye devicesRadEye BTcom Cover32Lutetium Test Adapters All RadEye 33, 34Accessories All RadEye 35, 36, 37Technical characteristics All RadEye 38, 393

RadEye Product FamilyFeatures Rugged and reliable Easily configured for specific tasks Large graphic display Durable and shock resistant Lightweight instruments,starting from 160 g Accurate with excellent EMI immunity Simple and intuitive user interface Use of rechargeable standard-size batteries Low power technologyRadEye - The next generation of radiation metersThermo Scientific offers a comprehensive range of advancedinstruments for radiation detection, dose rate and contaminationmeasurements.The characteristic features of this versatile pocket meter are thesmall size, the ease and flexibility of operation and its superiormeasurement performance, which is provided by the use ofsophisticated low power technology. Fully automated selfdiagnosis minimizes required maintenance.All essential functions are easily accessed, even while wearingprotective gloves.The top-mounted alarm-LED can be seen while the instrument isworn in a belt-holster. A built-in vibrator and an earphone-outputprovide silent alarming for use in very noisy environments.Opens the configuration menu.Once the menu is opened, features are selected byAdditional information (e.g., the accumulated dose, remainingMenu operationtime in a certain radiation field as well as mean and maximumAll of the parameters can be easily modified on the RadEye ormeasuring values) can be displayed.using the optional software. These menu operations can also bereconfigured to simplify the instrument and to avoid any faultyoperation. Navigation is made easy by a clear and intuitiveinterface.4On-switch and key lock - similar operation to your mobile phone.Operation of the audible indicator and alarm acknowledgement.

RadEye PRD configurationRadEye softwareAll settings and the data analysis can be done using the optional Windows - basedRadEye PRD logbookPC-software, and an accompanying reader device. In order to allow post-event analysis,the latest 1,600 dose rate values are stored in the data memory. For each datalogginginterval both the mean and the maximum measurement values are stored.Changes in configuration, along with alarms and errors, are saved in the RadEyememory. These events can be read out via the “logbook”. It is shown as a table and canbe saved to the PC or printed. The logbook has a maximum of 250 data sets. Severalevents that occur at the same time are saved as one record. On the display every eventis shown in one line for a clear view.RadEye PRD history5

RadEye PRD/PRD-ERSearch and FindFeatures High quality PMT for excellent response from 30 keV EMI immunity much better than photodiode Automatic background update, (i.e., no user actionnecessary)instruments NBR allows very low alarm levels for artificial NaI(Tl)-Detector for high response to SNM andradioactivityRDD s True dose and dose rate calculation avoids Designed to meet ANSI 42.33/1, 42.32 and IEC 62401 Energy response behavior in Roentgensignificant overestimation of low gamma energiesDetectorNaI(Tl)-detector with high qualitymicro photomultiplier;software switch for R or Sv energyresponse and calibrationMeasuring rangePRD: 1 µR/h - 25 mR/h[0.01 µSv/h – 250 µSv/h]PRD-ER: 1 µrem/h - 10 rem/h[0.01 µSv/h – 100 mSv/h]customs officers) or first responders (emergency services and lawenforcement).Overrange indicationPRD: Tested up to 1,000 R/h[10 Sv/h]PRD-ER: Tested up to 10,000 rem/h[100 Sv/h]The RadEye PRD is 5,000 - 100,000 times more sensitive than aEnergy range ( /- 30 %)60 keV - 1.3 MeV, excellentdetection from 30 keVResponse for Cs-137 (662 keV)1.5 cps per µR/h[150 cps per µSv/h]Response for Am-241 (60 keV)30 cps per µR/h[2000 cps per µSv/h]Linearity error (Cs-137)PRD: max. 10 %PRD-ER: max. 20 %Enhanced alarmingsensitivity by NBRYes, down to 1 µR/h[0.01 µSv/h]at low gamma energiesCosmic radiation backgroundSuppression typically 95 %RadEye PRDThe “orphan source” phenomena is a serious global problemas sources showing up unexpectedly in scrap yards, bordercrossings or numerous other public locations are a significantpotential threat. The RadEye PRD represents a high-performancemeasuring device for anyone responsible for findingradiation sources whether they be first preventers (border guards,typical electronic dosimeter.When looking for lost or hidden radiation sources orcontaminated materials, it is paramount to use a tool with highsensitivity and high selectivity.The RadEye PRD achieves this through a special technique basedon our patented Natural Background Rejection (NBR) technology.It is the only instrument of its type and size to achieve this.The RadEye PRD incorporates a high sensitivity NaI(Tl)scintillation detector with a miniature photo-multiplier allowingthe detection of very low radiation levels with particularemphasis on gamma emissions below 400 keV. Thus, in case ofa nuclear accident, the RadEye PRD is ideal for sensitive I-131detection and measurement.RadEye PRD #4250671Factory calibrated inexposure rate R/h6RadEye PRD #425067120Factory calibrated inH*(10) µSv/h

RadEye PRD/PRD-ERSearch and Find and Gamma Safety SurveysApplications Search and Safety Security First responders Steel and Recycling Environmental Monitoringw!NeRadEye PRD-ERSpecial proprietary circuitry allows the energy compensated doseand dose rate measurement up to 100 mSv/h (or 10 rem/h). Thus theRadEye PRD-ER is the ideal tool for both interdiction and response.Unlike instruments using two different detectors for the low dose raterange and the high dose rate range, the single detector arrangementin the RadEye PRD-ER offers the following unique advantages over theRadEye variants PRD-S and PRD-ER-SThe special firmware variants RadEye PRD-S # 425067130and RadEye PRD-ER# 425067135 includes the capability for scalermeasurement.For additional information please ask for a separate data sheet.whole measuring range: Consistent angular dependence No mutual shielding of neighboring detectors Consistent energy response No transition range with annoying hysteresis effects No high activity source for function test of high dose rate detectorrequiredWith the help of the RadEye PRD-ER test adapter, users can check theRadEye PRD-S gamma laboratorykit # 425069015full detector performance on a regular basis – without the need of ahigh dose rate calibration facility.RadEye PRD-ER #425067102Factory calibrated in exposure rate R/hYellow front coverRadEye PRD-ER #425067122Factory calibrated in H*(10) µSv/hYellow front coverRadEye PRD-ER #425067104Factory calibrated in exposure rate R/hBlack front coverLutetium Test Adapter for PRD and PRD-ERFor additional information please see pages 33-34.7

RadEye G/G-10Gamma Safety SurveysApplications Gamma surveys from background upto personal safety levels First Responders Nuclear Power Industry Radiography Radiation Protection Radiography G-10 is for H-10 deep dose rate measurementsWide range survey meter RadEye G-10 (SI-units) andRadEye G (US-market)The RadEye G and RadEye G-10 are lightweight andDetectorEnergy compensated GM-tubeMeasuring rangeRadEye G:50 µR/h - 10 R/hRadEye G-10: 0.5 µSv/h - 100 mSv/h[5 µrem/h - 10 rem/h]Overrange indicationTested up to 100 Sv/hEnergy range 30 %RadEye G:45 keV - 3 MeVRadEye G-10: 50 keV - 3 MeVCount rate for Cs-137(662 keV)17 cps per mR/h [1.7 cps per µSv/h]very rugged instruments designed for quick and reliablemeasurement of gamma dose rates.Modern electronic circuitry guarantees excellent linearity oversix decades of radiation intensity: from background level to100 mSv/h (10 R/h) - with unlimited overrange indication. Bothdevices incorporate a large energy compensated GM-tube forprecise dose rate measurement for gamma and X-ray.RadEye G: # 425067401 yellow front coverRadEye G-10: # 4250676 red front coverRadEye G-10 PTB: # 4250675 red front coverRadEye G: # 4250674 black front coverRadEye G: # 425067602 white front coverCommon features of RadEye G and GF seriesKey features Pocket size Accurate Lightweight Large graphic display withclear prefix and bar graph Extreme low power consumptionfor permanent operation Energy compensated up to 3 MeV8Check sourceTo ensure top functionality of the RadEye G series, we offer a test adapter based on200 kBq Ba-133 - exempt quantity referring to e.g. NRC/IAEA/EU regulations. # 425067072For use in the US, a 5 µCi Cs-137 test adapter is available as well. # 425067075CS137

RadEye GF/GF-10High Range Gamma SurveysApplications High range measurement Radiography SafetyHigh range gamma survey meter RadEye GF-10 (SI-units)and RadEye GF (US-market)The intelligent ratemeter algorithm (ADF mode) guarantees that evenDetectorEnergy compensated GM-tubeMeasuring rangeRadEye GF:500 µR/h - 300 R/hRadEye GF-10: 5 µSv/h - 3 Sv/h[500 µrem/h - 100 rem/h]Overrange indicationTested up to 100 Sv/hEnergy range 30 %RadEye GF:45 keV - 3 MeVRadEye GF-10: 50 keV - 3 MeVCount rate for Cs-137(662 keV)RadEye GF:1.3 cps per mR/hRadEye GF-10: 0.13 cps per µS/hthe smallest changes in dose rate are immediately detected, while atthe same time, random fluctuations are effectively suppressed.All essential functions are easily accessed while wearing protectivegloves. The alarm-LED can be seen while the instrument is worn in abelt-holster. The instrument is also equipped with a built-in vibratorand an earphone-output for silent alarming or use in very noisyenvironment.RadEye GF: # 425067475Background measurementAlarm thresholds - two trianglesin the bar graph, indication lowAlarm level 1 exceeded“Alarm 1” and “speaker” signsshow upAbsence of trend arrow indicatesstable radiation level - readingcan be takenRadEye GF-10: # 425067675Approaching a sourceAlarm thresholds - not yetexceeded.Trend arrow indicates increasingradiation level9

RadEye G-Ex seriesIntrinsically Safe Gamma SurveysFeatures Intrinsically safe according to ATEX standards Lightweight, only 160 g (5.6 oz.) Efficient and reliable dose and Low power technologydose rate measurements Large, clear and backlit display forerror-free readings Rugged and reliablew!NeRadEye G-Ex series- intrinsically safe personalradiation detectorsATEX Certification RadEye G-Ex InstrumentsII 2G-EX ia IIB T4In emergency response and in industry flammable and explosivematerials like gases, dust and fibers can occur. In such potentiallyATEX examination mark. This sign is required on alldevices used in European hazardous areas.explosive atmospheres it is necessary to use ATEX certifieddevices for your measurements.The Thermo Scientific RadEye G-Ex series comprises four versionsII 2Gof intrinsically safe handheld devices for gamma and dose ratemeasurements. They are designed according to the latest ATEXstandards to meet the needs of their operator in and aroundhazardous areas.ExExplosion protection based on European Ex-regulations.iaExplosion protection type, ”ia“ is the highest level ofprotection.IIBGas group for average reactive gases (except hydrogen,acetylene or disulfide)T4Temperature class gives the user the maximumtemperature of a surface that may be in contact to the Exatmosphere under fault conditions. T4 is rated at 135 C.Devices certified as ”intrinsically safe“ are designed to be unableto release sufficient electrical or thermal energy to cause ignitionof flammable materials like gas, dust or particulates.Beside the ATEX tags, the visual difference between the RadEyeversions is noted by the orange color of the front panel of theClassification of zones. II device is approved for all nonmining areas.2 category of the device, here it means that the deviceis rated for the second most hazardous areas. G designates atmosphere, in this case gas, vapors and mist.intrinsically safe versions.Inside, the RadEye G-Ex devices have been re-engineered toreduce energy safety issues and avoid the generation of heat andRadEye G-Ex: # 425067460RadEye GF-Ex: # 425067470electrical sparks. They are premium products designed for ultimateRadEye G-10-Ex: # 425067660safety and accurate dose rate measurements.RadEye GF-10-Ex: # 42506767010

RadEye G-Ex seriesIntrinsically Safe Gamma SurveysApplications Hazmat teams Fire brigades Refineries Oil platforms Locations with risk of explosion Marines and Coast GuardRadEye GF-10-Ex: From 5 µSv/h to3 Sv/hSensitivity (Cs-137, 660 keV)Measuring rangeRadEye G-10-Ex: 1.9 cps/µSv/hRadEye GF-10-Ex: 0.13 cps/µSv/hCheck sourceTo keep the radiation detector functionality of the RadEyeGand RadEyeG-10 we offer a test adapter based on 200kBqBa-133 - exempt quantity referring to e.g. NRC/IAEA/EUregulations. # 425067072For use in the U.S., a 5 µCi Cs-137 test adapter is available aswell. # 425067075CS137RadEye G-Ex: From 50 µR/h to 10 R/hRadEye GF-Ex: From 0.5 mR/h to 300 R/hRadEye G-Ex: 17 cps/mR/hUSASensitivity (Cs-137, 660 keV)SI-unitsMeasuring rangeRadEye G-10-Ex: From 0.5 µSv/h to100 mSv/hRadEye GF-Ex: 1.3 cps/mR/hDose0.5 µSv to 10 SvLinearity errormax. /- 10 % in the measuring rangeAlarm thresholdsTwo each thresholds for dose and dose rateEnergy range45 keV – 1.3 MeV according to IEC 60846Working temperature-20 C . 50 CRelative humidity10 . 90 % at 35 CProtection degreeIP 65 according to EN 60 529ATEX classificationII 2G Ex ia IIB T4 IBExU10ATEX1096Size96 x 61 x 31 mm without rubber protectorWeightapprox. 160 g, including 2 batteriesInternal memoryThe latest 1600 measured values are savedand can be read out via PC-program. Logbookwith 250 entries for changes of configuration,occurring alarms and errors11

RadEye G20-10/G20-ER10Gamma Surveys Including X-raysFeatures Menu-driven user interface results in low Energy compensated measurements from Lowtraining cost and immediate familiarity Huge internal data memory for both scalerEnergy to High Energy Low level measurements are easier and moreresults and continuous data recordingstable than Ion Chambers Bright backlit LCD display – plain text Leight weight (300 g), excellent gripmessages – different languages can bewith and without glovesselected Rugged and compact design, thick Audible indication: single pulse or chirperrubber protective covermode proportional to count rate Low cost of ownership with 500 h Earphone output for operation in loudoperation time with 2 AAA batteriesenvironment– rechargeable NiMH-cells can be usedRadEye G20-10/G20-ER10The RadEye G20-10 and G20-ER10 are excellent gamma survey meters with aflat energy response curve from 17 keV to 3 MeV according to ambient equivalent dose H*(10).The devices are suitable for dose rate measurements for X-ray scanner andfor medical isotopes including I-125.Gamma test adapter (50 g Lu2O3) for RadEye G20/G20-ER and portable scintillation detectors: # 4254948- 62 mm diameter, 7 mm height (aluminum housing)55 mm diameter, 3 mm height (Lu2O3 ceramics)- Induced net dose rate for RadEye G20: 0.25 µSv/h(25 µrem/h).- Time requirement for response verificationapproximately 5 minutesFor immediate response verification a 200 kBq Ba-133(exempt quantity) or other gamma test sources can beused.For additional information please see pages 33-34.RadEye G20-10: # 4250687RadEye G20-ER10: # 425068710Holster for RadEye G20/B20: # 42506851912

RadEye B20/B20-ERFor Alpha/Beta Surface ContaminationApplications HospitalsGeneral radiation protection for: Nuclear power industry Homeland security Pharmaceutical industry Fire departments Universities Emergency responseB20 is for normal measurements,B20-ER is for high range measurements.Features Lightweight (300 g), excellent grip with and without gloves Rugged and compact design, thick rubber protective cover Low cost of ownership with 500 h operation time with 2 AAAbatteries – rechargeable NiMH-cells can be used Menu-driven user interface results in low training cost andimmediate familiarity Huge internal data memory for both scaler results andcontinuous data recordingRadEye B20/B20-ER Bright backlit LCD display – plain text messages – differentThe RadEye B20/B20-ER models are the best choice forlanguages can be selectedcontamination and dose rate measurements. They are modern, Easy adaptation to different tasks by supervisor configuration,compact and measure alpha, beta, gamma and X-ray radiation.calibration, selection of measuring unitsThe RadEye B20/B20-ER models can also be used for accurate Versatile operation modes:dose rate surveys if used with correct energy compensated- Scaler/Timer with preset count and preset time for sampledoserate filter (17 keV– 3 MeV).For emergency response purposes alpha and beta- Continuous ratemeter mode for frisker operationcontamination can be discriminated using another optional- Dose rate modefilter. The RadEye B20 will automatically switch to the proper Audible indication: single pulse or chirper mode proportional tomeasuring unit, if an auto detection filter is fitted to the facecount rateof the B20 detector. This automatic function helps to avoid Earphone output for operation in loud environmentaccidental misuse.The instrument is part of the growing RadEye family of highend stand-alone meters, which are designed to exceed themost demanding user expectations.measurements IR PC Interface or Bluetooth as option Advanced Windows software is available as optionRadEye B20: # 4250685RadEye B20-ER: # 425068510Holster for RadEye B20/G20: # 42506851913

RadEye B20/B20-ERSurface Contamination/Gamma SurveyDetector1 pancake GM-tube, window dia.44 mm (1.7”); 1.8 – 2.0 mg/cm²)0 - 2 mSv/h [0 - 200 mrem/h]Measuring range (gamma dose

Multi purpose meter for contamination RadEye B20 13, 14, 15 Wide range multi purpose meter for dose rate and contamination RadEye B20-ER 13, 14, 15 Neutron detection and dose rate measurement RadEye NL 16, 17 α, βcontamination AB100 18 Survey